DL QuickSpecs
|
DL20
|
|
DL60
|
|
DL80
|
|
DL120
|
|
DL140
|
|
DL145
|
|
DL160
|
|
DL160se
|
|
DL165
|
|
DL180
|
|
DL185
|
|
DL320
|
|
DL325
|
|
DL345
|
|
DL360
|
|
DL365
|
|
DL380
|
|
DL385
|
|
DL388
|
|
DL560
|
|
DL580
|
|
DL585
|
|
DL740
|
|
DL760
|
|
DL785
|
|
DL1000
|
|
|
ML QuickSpecs
|
ML30
|
|
ML110
|
|
ML115
|
|
ML150
|
|
ML310
|
|
ML330
|
|
ML350
|
|
ML370
|
|
ML530
|
|
ML570
|
|
ML750
|
|
|
BL QuickSpecs
|
BL10e
|
|
BL20p
|
|
BL25p
|
|
BL260c
|
|
BL280c
|
|
BL2x220c
|
|
BL30p
|
|
BL35p
|
|
BL40p
|
|
BL420c
|
|
BL45p
|
|
BL460c
|
|
BL465c
|
|
BL480c
|
|
BL495c
|
|
BL60p
|
|
BL620c
|
|
BL660c
|
|
BL680c
|
|
BL685c
|
|
BL860c
|
|
|
SL QuickSpecs
|
SL160z
|
|
SL165z
|
|
SL170s
|
|
SL170z
|
|
SL230s
|
|
SL250s
|
|
SL270s
|
|
SL2x170z
|
|
SL335s
|
|
SL390s
|
|
SL4540
|
|
SL4545
|
|
|
XL QuickSpecs
|
XL170r
|
|
XL190r
|
|
XL220a
|
|
XL230a
|
|
XL730f
|
|
XL740f
|
|
XL750f
|
|
|
CL QuickSpecs
|
CL1850
|
CL1850 G1
| |
CL380
|
CL380 G1
| |
|
|
|
|
|
|
|
Proliant DL585 G2 QuickSpecs |
US QuickSpecs |
|
|
|
|
|
|
|
|
|
Proliant DL585 G2 Overview
HP
ProLiant DL585 Generation 2 (G2) |  |  | Proliant DL585 G2 Front View: | Proliant DL585 G2 Rear View: | 1. |
Hot Plug Redundant Fans (standard) | 1. | Redundant
hot-plug power supply (optional) | 2. |
System Insight Display | 2. |
PCI Express and PCI-X expansion slots | 3. |
Hot Plug Redundant Fans (standard) | 3. |
Hot-plug power supply (primary) | 4. | 1.44
MB Diskette Drive (optional) | 4. |
T-15 Torx screwdriver | 5.
| DVD/CD-RW drive
(standard) | 5. | NIC
connector 2 | 6.
| Front Panel LED
Display (internal and external health, Unit ID light) and Power Button | 6.
| NIC connector 1 | 7.
| Integrated Lights-Out 2 (iLO
2) connector | 7. | Two
USB ports | 8. | Serial
connector | 8. | One
video port | 9. | USB
connectors (two) | 9.
| Front accessible processor
/ memory cage | 10. | Mouse
connector | 10.
| Eight bay Small
Form Factor (SFF) Serial Attached SCSI (SAS) drive cage | 11.
| Keyboard connector | 12.
| Video connector | 11. | 4U
(7" Height) Rack Form Factor | 13. |
Rear UID button and LED | 12. | Hot
Plug Redundant Power Supply | | 13. | Nine
PCI I/O Slots (2 64-bit/100MHz PCI-X, 4 PCI-Express x4, 3 PCI-Express x8) | 14. | Hot
Plug Redundant Power Supply | 15. | Removable
Top Access Panel |
|
What's
New | - Upgrade
options now available for Quad-Core 8300 series AMD processors
|
|
At
A Glance | The
HP ProLiant DL585 G2 supports the AMD 8000 processors, enabling a huge boost in
performance over single-core processors. The G2 follows the award winning legacy
of the HP ProLiant DL585 by offering exceptional price/performance and price per
watt metrics. The 128 GB memory footprint enables most applications to run faster
or support more users than other systems and with the inclusion of Rev F processors
the ProLiant DL585 G2 has now been optimized for virtualization. The ProLiant
DL585 G2 combines AMD Opteron™ processor technology, best-in-class management
and outstanding uptime features in an enterprise-class system ideal for large
data center deployments. - Processors:
- Dual-Core AMD 8200 Series Processors
- DL585 G2 Memory:
- Up to 128 GB of memory, supported by (32) slots of PC2-5300 Registered
DIMMs at 667MHz
- Storage Controller:
- HP Smart Array P400/256MB Controller (optional 512MB battery backed write
cache)
- HP Smart Array P400/512MB BBWC Controller standard on some models
- Internal
Drive Support:
- Up to 1.168TB (8 x 146GB SFF SAS
hot plug drives)
- Slimline floppy (optional) and slimline DVD/CD-RW (standard)
drives
- Network Controller:
- Two
embedded NC371i Multifunction Gigabit Network Adapters with TCP/IP Offload Engine,
including support for Accelerated iSCSI through an optional Licensing Kit
- Expansion
Slots:
- 9 total slots: (3) x8 PCI-Express; (4)
x4 PCI-Express; (2) PCI-X (100MHz)
- One slot populated with the Smart
Array P400 Controller
- Video Ports:
- One front and one rear video ports
- Integrated
Hypervisors (Optional):
- VMware 3i virtualization
technology
- Citrix XenServer virtualization technology
- USB
Ports:
- (5) Total USB 2.0 Ports: (2) front; (2)
rear; (1) internal
- Redundancy:
- Redundant
hot plug power supplies and fans
- Management:
- Integrated Lights-Out 2 featuring Integrated Remote Console with KVM over
IP performance over shared network access
- Innovative diagnostic lighting
(System Insight Display) for rapid response to service events
- Form
Factor:
- Delivering maximum performance in a versatile,
rack optimized form factor
- Deployment/Serviceability:
- Tool-less and virtually cable-less internal design
- Rapid Deployment
racking solution (rack rails and cable management)
- Customer Self Repair
(CSR): HP products are designed with many CSR parts to minimize repair time and
allow for greater flexibility in performing defective parts replacement
- Warranty:
- This product is covered by a global limited warranty
and supported by HP Services and a worldwide network of HP Authorized Channel
Partners resellers. Hardware diagnostic support and repair is available for three
years from date of purchase. Support for software and initial setup is available
for 90 days from date of purchase. Enhancements to warranty services are available
through HP Care Pack services or customized service agreements. SATA hard drives
have a one-year warranty.
NOTE: Server
Warranty includes 3-Year Parts, 3-Year Labor, 3-Year Onsite support with next
business day response. Warranty repairs may be accomplished through the use of
Customer Self Repair (CSR) parts. These parts fall into two categories: 1) Mandatory
CSR parts are designed for easy replacement. A travel and labor charge will result
when customers decline to replace a Mandatory CSR part; 2) Optional CSR parts
are also designed for easy replacement but may involve added complexity. Customers
may choose to have HP replace Optional CSR parts at no charge. Additional information
regarding worldwide limited warranty and technical support is available at: https://h18004.www1.hp.com/products/servers/platforms/warranty/index.html |
Standard Features
NOTE: For a
brief, printer friendly data sheet that describes this product and informs
you of the essential capabilities and specifications, please visit: https://h71028.www7.hp.com/ERC/downloads/4AA0-7461ENW.pdf.
|
Processor
Two or four of the following supported depending
on Model
|
AMD Opteron™ Processor 8224SE,
Dual-Core (3.2 GHz, 120 Watts) |
AMD Opteron™ Processor 8222,
Dual-Core (3.0 GHz, 95 Watts) |
AMD Opteron™ Processor 8222SE,
Dual-Core (3.0 GHz, 120 Watts) |
AMD Opteron™ Processor 8220,
Dual-Core (2.8 GHz, 95 Watts) |
AMD Opteron™ Processor 8220SE,
Dual-Core (2.8 GHz, 120 Watts) |
AMD Opteron™ Processor 8218,
Dual-Core (2.6 GHz, 95 Watts) |
AMD Opteron™ Processor 8216,
Dual-Core (2.4 GHz, 95 Watts) |
AMD Opteron™ Processor 8214,
Dual-Core (2.2 GHz, 95 Watts) |
AMD Opteron™ Processor 8212,
Dual-Core (2.0 GHz, 95 Watts) |
|
Cache
Memory |
1MB Integrated Level 2 Cache memory per
core |
|
Upgradeability |
HP ProLiant DL585
G2 servers can support up to 4 processors. |
Upgradeable to quad-core processors (when available) |
|
Chipset |
nVidia NForce Professional
2200 and 2050 chipsets, and AMD-8132 chipset |
|
Memory Protection & Functionality |
Advanced ECC |
|
Memory
|
Type |
PC2-5300 Registered DIMMs at 667 MHz
|
Standard
One of the following depending on Model |
2 GB (4 x 512 MB)
|
4 GB (4 x 1 GB) |
8 GB (8 x 1 GB) |
Maximum |
128 GB (32 x 4 GB) |
|
Network Controller |
Two embedded NC371i
Multifunction Gigabit Network Adapters with TCP/IP Offload Engine, including
support for Accelerated iSCSI through an optional Licensing Kit |
|
Expansion Slots |
| Expansion
Slot # | Technology |
Width | Connector
Width* | Bus
Number** | Form
Factor | Notes |
1 |
PCI-X |
64-bit | N/A | 42h | FH/HL |
100MHz | 2 | PCI-X |
64-bit | N/A | 42h | FH/FL |
100MHz | 3 |
PCI Express |
x4 | x8 | 49h | FH/FL |
| 4 |
PCI Express |
x4 | x8 | 4Ch | FH/FL |
| 5 |
PCI Express |
x8 | x16 | 46h | FH/FL |
| 6 |
PCI Express |
x4 | x8 | 4Fh | FH/FL |
| 7 | PCI
Express | x8 | x16 | 02h | FH/FL | |
8 | PCI
Express | x8 | x16 | 05h | FH/FL | |
9 | PCI
Express | x4 | x8 | 08h | FH/HL | Reserved
for storage controller | *
Default bus assignment. Inserting cards with PCI bridges may alter the actual
bus assignment number. ** Slots are enumerated differently based on OS. MS
OS's enumerate from lowest to highest Device ID by bus (starting with the lowest
bus). FH = Full height; FL = Full length; HL = half-length; LP = Low profile. |
|
|
Manageability |
Integrated Lights-Out
2 (iLO 2) Standard Management (ASIC on the System Board) |
|
Storage Controllers
One of the following depending on Model
|
HP Smart Array P400/256MB
Controller (in a PCI-Express slot)
NOTE: Standard on 2.0GHz and 2.2GHz
models. |
HP Smart Array P400/512MB BBWC Controller (in a PCI-Express slot)
NOTE: Standard on 2.4GHz, 2.6GHz,
2.8GHz, and 3.0GHz models.
|
|
Storage Data Protection |
The Battery-Backed
Write Cache (BBWC) Enabler for the Smart Array P400 Controller protects
up to 512-MB write cache memory from hard boot, power, controller, or system
board failures. |
- Standard on all HP ProLiant DL585 G2 Models
- Battery charge/life: Up to 72 hours/3 years
- Transportable data protection
- Increases overall controller performance
|
NOTE:
Safely transport your write cache data to another HP ProLiant DL585
G2 in the data center by removing the BBWC Enabler and Smart Array P400
Controller Memory Module simultaneously (connected by short cable). |
|
Storage |
Diskette Drive |
Optional 1.44 MB Diskette Drive
(slimline) - ejectable for security and serviceability |
Optical Drive |
Slimline DVD/CD-RW Drive Standard
on all models - ejectable for security and serviceability |
Hard Drives |
None ship standard |
Hard Disk Drive Backplane |
Internal SAS backplane supports
up to eight SFF hard disk drives |
|
Maximum
Internal Storage Type |
Hot Plug SAS |
1.168TB |
8 x 146GB SFF SAS drives (internal
hot plug) |
Hot Plug SATA |
960GB |
8 x 120GB SFF SATA (internal
hot plug) |
|
Interfaces |
Serial |
1 |
Pointing Device (Mouse) |
1 |
Video |
1 front, 1 rear |
Keyboard |
1 |
USB 2.0 Ports |
2 front, 2 rear, 1 internal |
iLO 2 Remote Management |
1 |
Network RJ-45 |
2 |
|
Graphics |
Integrated ATI-RN50 with 32MB
DDR memory |
|
Form Factor |
Rack (4U = 7 inches), ships
with sliding rails and cable management system
Space saving form factor (4U) provides space efficiencies while providing
maximum deployment flexibility |
|
HP
Insight Control Environment Management Suite | HP
Insight Control Environment delivers foundation management, including remote monitoring,
hardware resource deployment, health monitoring, software version control, performance
monitoring, vulnerability scanning and patch management, and power management.
HP Insight Control Environment installs and licenses the following components
by default using a wizard-based integrated installer: - HP Systems Insight
Manager
- HP iLO Advanced Pack
- HP Insight Power Manager
- HP
Rapid Deployment Pack
- HP Performance Management Pack
- HP Vulnerability
and Patch Management Pack
- HP Virtual Machine Management Pack
Additional
ProLiant Essentials software and management tools included on the Insight Control
Management kit can be installed manually - HP Server Migration Pack -
Universal Edition
NOTE: HP Server Migration
Pack - Universal Edition is licensed separately from the Insight Control Environment
Suite. - HP Open Service Event Manager
- HP Service Essentials
Remote Support Pack
NOTE:
Server Migration Pack - Universal Edition can be installed from the SMP Universal
CD included in the Insight Control Management media kit. NOTE: For additional
product and licensing information about HP Insight Control Environment, visit:
https://www.hp.com/go/ice. HP
Insight Control Environment for Linux (ICE-Linux) provides comprehensive discovery,
imaging & deployment, monitoring, and management for Linux-based ProLiant
server platforms. Built on the industry-leading HP Systems Insight Manager framework,
this solution integrates open source technology with experience leveraged from
HP's Linux products in HP ICLE and HP XC Clusters, while providing paths to the
future with developing management technologies. HP Insight Control management
suites and most HP ProLiant Essentials include a one year of 24 x 7 HP Software
Technical Support and Update Service ensuring rapid access to HP support staff
and proactive delivery of software updates. For more information about this service,
please visit: https://www.hp.com/services/insight. |
|
Server Management Stand Alone Software Product - ProLiant
Essentials |
HP Systems Insight Manager | HP
Systems Insight Manager (HP SIM) provides a unified, secure and extensible standards-based
environment to centrally manage servers, storage and other infrastructure devices,
(both HP and non-HP) across multiple operating system platforms. |
HP ProLiant Essentials
Server Migration Pack - Universal Edition | Upgrading,
replacing, or virtualizing your existing server? Effortlessly transition to new
virtual or physical HP ProLiant servers or BladeSystem with automated, accurate
and affordable migration of OS, application and data. SMP Universal automates
the manual processes required for migrating servers between physical or virtual
platforms, whether migrating to VMware or Microsoft virtual machines. SMP Universal
allows all of the following migrations:
- physical to ProLiant
- physical to virtual
- virtual to virtual
- virtual
to ProLiant
NOTE:
For more information, visit: https://www.hp.com/go/migrate.
|
HP ProLiant Essentials Performance Management Pack | Performance
Management Pack (offered exclusively through the Insight Control suites) - a performance
management solution that identifies and explains hardware performance bottlenecks
on ProLiant servers and attached options enabling users to better utilize their
valuable resources |
HP ProLiant Essentials Integrated Lights-Out (iLO 2) Advanced Pack | Upgrades
the iLO 2 processor with comprehensive remote control including Virtual KVM remote
graphical console, enhanced console sharing and replay, virtual media (floppy,
CD/DVD, USB key), virtual folders, and enterprise security (directory services
and two-factor authentication). |
HP ProLiant Essentials Accelerated iSCSI Pack | Enables
the embedded Multifunction network controller to serve as both a NIC and an iSCSI
HBA providing access to SAN storage over the same connection used for networking.
Processing of the protocol stack is offloaded to the NIC reducing CPU utilization
and greatly improving the speed with which the requests are processed and sent
to the network. | NOTE:
Flexible and volume quantity license kits are available for ProLiant Essentials
Value Packs. Refer to: https://www.hp.com/servers/proliantessentials
or the various ProLiant Essentials Value Pack product QuickSpecs for more information. |
|
Core Infrastructure Management | SmartStart | SmartStart
is a tool that simplifies server setup, providing a rapid way to deploy reliable
and consistent server configurations. For more information, please visit the SmartStart
Web site at: https://www.hp.com/servers/smartstart.
SmartStart version supported (minimum):
SmartStart 7.60. |
Insight
Management Agents | The
Insight Management Agents should be installed on all HP servers to present system
instrumentation, health and configuration information into HP Systems Insight
Manager and the HP System Management Homepage. The HP System Management Homepage
aggregates systems data from Insight Management Agents and other HP management
tools, providing a consolidated browser-based interface for managing individual
servers. Insight Management Agents and The HP System Management Homepage
are included on ProLiant Support Packs, and can also be installed using the server
profiles provided with the ProLiant Essentials Rapid Deployment Pack. For
additional information about the Management Agents and the HP System Management
Homepage please visit the management Web site at: https://www.hp.com/servers/manage. |
Subscriber's Choice | Subscriber's
Choice Driver and Support Alerts/Notifications is a web-based email subscription
service that provides software and driver change notifications for ProLiant products.
Sign up at: https://www.hp.com/go/subscriberschoice and
customize your profile to receive various new alerts as they become available,
on a weekly or monthly basis. | ProLiant
Support Packs and ROMPaq, software | The
latest software, drivers, and firmware fully optimized and tested for your ProLiant
server and options, available through ProLiant Support Packs the ProLiant Essentials
Rapid Deployment Pack, SmartStart or downloaded from software and drivers download
pages website at: https://www.hp.com/go/support. |
|
HP
Serviceguard for Linux (SGLX) |
HP Serviceguard for Linux is a high availability clustering solution designed
to protect applications and services from a wide variety of software and hardware
failures, monitoring the health of each server (node) and quickly responding to
failures such as those that affect system processes, system memory, LAN media
and adapters, and application processes. The following is a quick summary
of HP Serviceguard for Linux features and support. For the most recent list of
Linux distributions & kernels, servers and storage supported with Serviceguard
for Linux, see the Serviceguard for Linux Datasheet, available at: https://www.hp.com/go/sglx/info. - Supported
Linux Distributions:
- Red Hat EL 4
- Red Hat EL 5
- SUSE SLES10
- Supported
Server Platforms
- HP Integrity BladeSystem to Superdome
- HP ProLiant
BladeSystem p-Class & c-Class
- HP ProLiant DL
- HP ProLiant ML
- IBM System x
- Dell PowerEdge
- Sun x64
- Fujitsu
Siemens PRIMERGY
- Hypervisors
- HP Integrity Virtual Machines
- VMware
ESX
- Application Integration Toolkits
- HP Serivceguard
for Linux Oracle Database Toolkit
- HP Serviceguard Extension for SAP on
Linux (SGeSAP/LX)
- Free Application Integration Toolkits:
- Apache
- MySQL
- NFS
- PostgreSQL
- Samba
- Tomcat
- Sendmail
- Disaster
Tolerant Solutions
- HP Serviceguard for Linux Extended Distance
Cluster (XDC) extends cluster distances up to 100 km, utilizes software RAID mirroring
for data replication and is storage array independent
o HP StorageWorks XP/EVA
Cluster Extension Software for Linux (CLX) works seamlessly with HP Serviceguard
for Linux, HP StorageWorks Continuous Access, and HP Disk Arrays to automate failover
and failback between sites
- Software updates are distributed
by HP Services to customers with support contracts
NOTE:
For additional information on HP Serviceguard for Linux, visit: https://www.hp.com/go/sglx
or see the HP Serviceguard for Linux QuickSpecs. NOTE: HP Serviceguard
for Linux products for HP ProLiant and select 3rd party x86 class servers include
one year of 24 x 7 HP Software Technical Support and Update Service ensuring rapid
access to HP support staff and proactive delivery of software updates. For more
information about this service, please visit: https://www.hp.com/services/swsupport. |
|
Industry Standard
Compliance |
ACPI 1.0a. Compliant |
PCI 2.2 Compliant |
PXE Support |
WOL Support (with embedded NC371i
Multifunction Gigabit Network Adapters) |
Physical Address Extension (PAE)
Support |
Microsoft® Logo certifications |
USB 2.0 Support |
|
Remote
Management | Integrated Lights-Out
2 (iLO 2) Standard Management |
- Virtual Text Remote Console (pre OS-only)
- Remote Serial Console
- Virtual
Power Button Control
- Virtual Unit ID control
- Integrated Remote
Console (ActiveX Control client)
- Dedicated & full function shared
network connectivity with VLAN
- Embedded system health
- Browser,
command line and scripted access
- Automatic IP Configuration via DHCP/DNS/WINS
- Industry Standard 128-bit Secure Sockets Layer (SSL) and Secure Shell
security (SSH)
- Advanced Encryption Standard (AES) / Triple Data Encryption
Standard (3DES)
- OS independent hardware health status
- IML and
iLO Event Logging
- Support for 12 user accounts with customizable access
privilege
|
|
Intelligent Manageability |
HP Systems Insight Manager
SmartStart
Redundant ROM
Remote Flash ROM
Management Agents
Integrated Management Log (IML)
Automatic Server Recovery-2 (ASR-2)
ROM-Based Setup Utility (RBSU)
Dynamic Sector Repairing (with Smart Array Controllers)
Drive Parameter Tracking (with Smart Array Controllers)
Pre-Failure Warranty (covers processors, SAS hard drives and memory)
Redundant/adaptive load balancing NIC Support |
|
Availability |
- Smart Array P400 Controller with standard Battery Backed Write Cache
(BBWC) Enabler provides transportable data protection and increases
overall controller performance. Up to 512MB Battery Backed Write Cache
protection available on all HP ProLiant DL585 G2 models.
- Up to eight hot-plug SFF SAS Hard Drives
- Dual Hot-Plug Redundant Power Supplies
- Hot-Plug Redundant Fans (standard)
|
Fans are N+1 hot plug redundant
and individually removable. |
|
Serviceability |
- System Insight Display - precisely depicts all major subsystems of
the server (PCI I/O, Memory, CPU, Redundant Cooling, Interlock, Thermtrip)
and gives instant visual indication of fault status. Located on top
front of server, beneath lid.
- Tool-less, virtually cable-less interior design
- Tool-less access to interior of server
- Two ejectable, slimline Media Bay media drives (DVD/CD-RW standard
with support for optional floppy or optical drives) are removable
without the use of tools
- Front accessible processors and memory
- PCI Card Guides locks full length PCI cards in place during transit
- Six individually removable fans connect without cables to the
system board
- Tool-less removal of system board
- Quick Deploy Rails
- Tool-less design "snap in" rail
|
|
Security |
Power-on password
Keyboard password
Diskette drive control enable/disable
Diskette boot control enable/disable
External USB port enable/disable
Network Server Mode
Serial interface control
Administrator's password
Removable Diskette drive (optional)
Removable optical drive |
|
Power
Supply | 910W (low line), 1300W
(high line) with 12V main output. Size is 2.8"(H) X 4.9"(W) X 7.5"(L).
NOTE: One Hot Plug Power Supply ships
standard with 2.0GHz and 2.2GHz models (optional Redundant Hot Plug Power Supply
Option Kit). NOTE: Two Hot Plug Power Supplies ship standard with 2.4GHz,
2.6GHz, 2.8GHz, and 3.0GHz models. |
|
Server
Power Cords | Asia Pacific | IEC320-C14
to IEC320-C19 Jumper Cord | Europe | IEC320-C14
to IEC320-C19 Jumper Cord | Japan | JIS
C8303 to IEC320-C19 IEC320-C14 to IEC320-C19 Jumper Cord | PRC | IEC320-C14
to IEC320-C19 Jumper Cord | USA
| IEC320-C14 to IEC320-C19 Jumper
Cord | NOTE:
The HP ProLiant DL585 G2 servers ship standard worldwide with a 6-foot IEC 320-C14
to IEC320-C19 jumper cord. Japanese models also include a 3.6 meter lowline (100V)
power cord. If you require a local power cord, please check the Power Specifications
below for the appropriate country-specific power cord, or consult the Power Cord
Matrix: https://www.hp.com/go/powercordmatrix.
| |
System Fans |
Standard |
6 Hot plug, redundant fans (individually
removable) |
Maximum |
6 Hot plug, redundant fans (individually
removable) |
|
Rack
Airflow Requirements |
Rack 10000 series Cabinets |
The increasing power of new high-performance processor technology requires
increased cooling efficiency for rack-mounted servers. The 10000 Series
Racks provide enhanced airflow for maximum cooling, allowing these racks
to be fully loaded with servers using the latest processors.
|
CAUTION: If
a third-party rack is used, observe the following additional requirements
to ensure adequate airflow and to prevent damage to the equipment: |
- Front and rear doors: If your 42U server rack includes closing
front and rear doors, you must allow 5,350 sq cm (830 square inches)
of hole evenly distributed from top to bottom to permit adequate airflow
(equivalent to the required 64 percent open area for ventilation).
- Side: The clearance between the installed rack component
and the side panels of the rack must be a minimum of 7 cm (2.75 inches).
|
CAUTION: Always
use blanking panels to fill all remaining empty front panel U-spaces in
the rack. This arrangement ensures proper airflow. Using a rack without
blanking panels results in improper cooling that can lead to thermal damage.
NOTE: For additional information, refer to the Setup and Installation
Guide or the Documentation CD provided with the server, or to the server
documentation located in the Support section at the following URL: www.hp.com/servers/dl585-g2.
|
|
Rack Mounting Requirements |
HP ProLiant DL585 G2 rack models
provide tool-free support for racks with square or round mounting holes
(including Compaq/HP 7000, 9000, 10000, HP/E series, H9 series and third
party racks) with an adjustment range from 24" 36" in depth.
The ambidextrous cable management arm can be mounted on either the left
or right side for improved cable management.
HP ProLiant DL585 G2 in Telco Racks Support for all 2-post Telco racks requires
the use of the standard rack kit and an additional option kit from Rack
Solutions (https://www.racksolutions.com/hp/) |
|
Factory
Express Portfolio for Servers and Storage |
HP Factory Express offers configuration, customization, integration and deployment
services for HP servers and storage products. Customers can choose how their factory
solutions are built, tested, integrated, shipped and deployed. Factory
Express offers service packages for simple configuration, racking, installation,
complex configuration and design services as well as individual factory services,
such as image loading, asset tagging, and custom packaging. HP products supported
through Factory Express include a wide array of servers and storage: HP Integrity,
HP ProLiant, HP ProLiant Server Blades, HP BladeSystem, HP 9000 servers as well
as the MSAxxxx, VA7xxx, EVA, XP, rackable tape libraries and configurable network
switches. For more information on Factory Express services for your specific
server model, please contact your sales representative or go to: https://www.hp.com/go/factory-express. |
|
HP
Enterprise Configurator | The
HP eCo-Enterprise Configurator now provides factory default racking for our HP
hardware portfolio. This approach is aligned with our strategic direction to meet
the needs and expectations of our valued customers. If you require "custom"
rack configuration, please contact HP's Customer Business Center or an Authorized
Partner for assistance. |
|
Service and Support |
HP Care Pack services provide total care and support expertise with committed
response designed to meet your IT and business needs.
HP Care Pack services include coverage for the HP branded hardware options
qualified for the server and purchased at the same time or afterward that
are internal to the enclosure. This also includes the 22" and smaller
external monitors and tower UPS options up to 3kVA. These items will be
covered at the same service level and for the same coverage period as
the server. Coverage of UPS Battery is not included, and standard warranty
terms & conditions apply. For servers or storage systems installed
within a rack, service also covers all HP qualified rack options installed
within the same rack.
To fully capitalizing on your HP ProLiant servers' capabilities requires
a service partner who thoroughly understands your server technology and
systems environment. HP Services, an industry leader in provision of multi
vender support solutions, provides a range of support services designed
to meet the varying needs of your business. Whether an SMB, or large global
corporation, HP has a ProLiant server support offer to help you speedily
deploy and maximize system uptime.
Recommended Service - simplify ProLiant solution implementation,
maintenance, and management.
- Support: 3-Year 4-Hour response 24x7 Same Business Day Coverage only
- Deployment Service: Installation and Start up only
Enhanced Service - optimize service level to increase IT performance
and availability.
- Support: 3-Year Support Plus 24 only
Refer to the information on "Installation & Start-Up" for
service on ProLiant server and Microsoft or Linux O/S per the Customer
Description and/or Data Sheet; to be delivered on a scheduled basis 8am-5pm,
M-F, excluding HP holidays.
NOTE: For a complete listing of service
offerings and information visit:
https://www.hp.com/services/proliantservices
https://www.hp.com/go/proliant/carepack
|
Solutions
Solutions |
Designed for enterprise customers
with growing data centers and application and Internet service providers
that require a rack optimized 4-processor server that delivers maximum performance
and high availability for highly complex, business critical applications.
Specifically, the HP ProLiant DL585 G2 would be excellent for running the
following types of applications: |
Typical Usage: |
- High Performance Computing (HPC)
- Electronic Design Automation (EDA)/Semiconductor
- Financial
- Large database applications
- ERP / CRM
- Petrochemical
- Life Science and Material Science
- Video Rendering
|
Models
Models
| DL585R02
O3.0GHz-1 MB, 8 GB, 120W (4P Dual-Core) 448183-xx1 | Processor(s) | (4)
AMD Opteron™ Processor 8222SE, Dual-Core (3.0 GHz, 120 Watts) |
Cache Memory | 1-MB
Integrated Level 2 Cache | Memory |
8 x 1 GB of PC2-5300 DDR SDRAM (Standard) to 128 GB, running at 667 MHz |
Network Controller | Two
embedded NC371i Multifunction Gigabit Network Adapters | Storage
Controller | HP Smart Array P400/512MB
BBWC Controller | Manageability | Integrated
Lights-Out 2 (iLO 2) Standard management (integrated on system board) |
Hard Drives | None
ship standard | Internal
Storage | 1.168TB max (with optional
146GB SFF SAS Hot Plug hard drives) | Power
Supply | Two 910W/1300W Power
Supplies standard (second power supply for redundancy) | Optical
Drive | Slimline DVD/CD-RW Drive
(8X/24X) (ejectable) | Form
Factor | Rack 4U |
|
DL585R02
O2.8GHz-1 MB, 8 GB, 95W (4P Dual-Core) 439727-xx1 | Processor(s) | (4)
AMD Opteron™ Processor 8220, Dual-Core (2.8 GHz, 95 Watts) |
Cache Memory | 1
MB Integrated Level 2 Cache | Memory |
8 x 1 GB of PC2-5300 DDR SDRAM (Standard) to 128 GB, running at 667 MHz |
Network Controller | Two
embedded NC371i Multifunction Gigabit Network Adapters | Storage
Controller | HP Smart Array P400/512MB
BBWC Controller | Manageability | Integrated
Lights-Out 2 (iLO 2) Standard management (integrated on system board) |
Hard Drives | None
ship standard | Internal
Storage | 1.168TB max (with optional
146GB SFF SAS Hot Plug hard drives) | Power
Supply | Two 910W/1300W Power
Supplies standard (second power supply for redundancy) | Optical
Drive | Slimline DVD/CD-RW Drive
(8X/24X) (ejectable) | Form
Factor | Rack 4U |
|
DL585R02
O2.6GHz-1 MB, 4 GB, 95W (2P Dual-Core) 413929-xx1 | Processor(s) | (2)
AMD Opteron™ Processor 8218, Dual-Core (2.6 GHz, 95 Watts) (2 or 4
supported) | Cache
Memory | 1-MB Integrated Level
2 Cache | Memory |
4 x 1 GB of PC2-5300 DDR SDRAM (Standard) to 128 GB, running at 667 MHz |
Network Controller | Two
embedded NC371i Multifunction Gigabit Network Adapters | Storage
Controller | HP Smart Array P400/512MB
BBWC Controller | Manageability | Integrated
Lights-Out 2 (iLO 2) Standard management (integrated on system board) |
Hard Drives | None
ship standard | Internal
Storage | 1.168TB max (with optional
146GB SFF SAS Hot Plug hard drives) | Power
Supply | Two 910W/1300W Power
Supplies standard (second power supply for redundancy) | Optical
Drive | Slimline DVD/CD-RW Drive
(8X/24X) (ejectable) | Form
Factor | Rack 4U |
|
DL585R02
O2.4 GHz-1 MB, 2 GB, 95W (2P Dual- core) 413928-xx1 | Processor(s) | (2)
AMD Opteron™ Processor 8216, Dual-Core (2.4 GHz, 95 Watts) (2 or 4
supported) | Cache
Memory | 1-MB Integrated Level
2 Cache | Memory | 4
x 512 MB of PC2-5300 DDR SDRAM (Standard) to 128 GB, running at 667 MHz |
Network Controller | Two
embedded NC371i Multifunction Gigabit Network Adapters | Storage
Controller | HP Smart Array P400/512MB
BBWC Controller | Manageability | Integrated
Lights-Out 2 (iLO 2) Standard management (integrated on system board) |
Hard Drives | None
ship standard | Internal
Storage | 1.168GB max (with optional
146GB SFF SAS Hot Plug hard drives) | Power
Supply | Two 910W/1300W Power
Supplies standard (second power supply for redundancy) | Optical
Drive | Slimline DVD/CD-RW Drive
(8X/24X) (ejectable) | Form
Factor | Rack 4U |
|
DL585R02
O2.2 GHz-1 MB, 2 GB, 95W (2P Dual-Core) 418550-xx1 | Processor(s)
One of the following depending on Model
| (2) AMD Opteron™ Processor
8214, Dual-Core (2.2 GHz, 95 Watts) (2 or 4 supported) | Cache
Memory | 1 MB Integrated Level
2 Cache | Memory |
4 x 512 MB of PC2-5300 DDR SDRAM (Standard) to 128 GB, running at 667 MHz |
Network Controller | Two
embedded NC371i Multifunction Gigabit Network Adapters | Storage
Controller | HP Smart Array P400/256MB
Controller | Manageability | Integrated
Lights-Out 2 (iLO 2) Standard management (integrated on system board) |
Hard Drives | None
ship standard | Internal
Storage | 1.168TB max (with optional
146GB SFF SAS Hot Plug hard drives) | Power
Supply | One 910W/1300W Power
Supply standard (second power supply for redundancy is optional) |
Optical Drive | Slimline
DVD/CD-RW Drive (8X/24X) (ejectable) | Form
Factor | Rack 4U |
|
Country Code Key |
XX=00 |
US |
XX=20 |
Brazil |
XX=29 |
Japan |
XX=37 |
A/P |
XX=42 |
Europe |
XX=AA |
PRC |
Configuration Information - Factory Integrated Models
NOTE:
This section lists some of the steps required to configure a Factory
Integrated Model. To ensure only valid configurations are ordered, HP recommends
the use of an HP approved configurator. Contact your local sales representative
for information on CTO product offerings and requirements.
NOTE: HP does not allow factory integration of options into standard
models listed above. Configure-to-order servers must start with a CTO Chassis.
NOTE: This product offering does not support HP Factory Express Server
Configuration Level 1.
NOTE: FIO indicates that this option only available as a Factory
Installable Option. |
|
Step
1: Base Configuration |
|
Models |
HP ProLiant DL585
G2 Rack CTO Chassis |
418633-B21
|
Factory Integrated
Models ship with: |
|
Two embedded NC371i Multifunction Gigabit Network Adapters
Integrated Lights-Out 2 (iLO 2) Standard management
Six (6) Redundant Hot Plug Fans
One Hot Plug Power Supply
Rack 4U Form Factor
|
|
|
Step
2: Choose Required Options (only one of the following from each list unless
otherwise noted) |
Processors |
AMD Opteron™
8224SE 3.2 GHz-1 MB Dual-Core Processor (120W) 2P Option Kit
NOTE: If four processors are desired, select one 458932-B21 and one
458932-B21. |
|
AMD Opteron™
8222 3.0 GHz-1 MB Dual-Core Processor (95W) 2P Option Kit
NOTE: If four processors are desired, select one 458933-B21 and one
458933-B21. |
|
AMD Opteron™
8222SE 3.0 GHz-1 MB Dual-Core Processor (120W) 2P Option Kit
NOTE: If four processors are desired,
select one 448184-B21 and one 448184-B21. |
448184-B21
|
AMD Opteron™
8220 2.8 GHz-1 MB Dual-Core Processor (95W) 2P Option Kit
NOTE: If four processors are desired,
select one 439728-B21 and one 439728-B21. |
439728-B21
|
AMD Opteron™
8218 2.6 GHz-1 MB Dual-Core Processor 2P Option Kit
NOTE: If four processors are desired,
select one 413933-B21 and one 413933-B21. |
413933-B21
|
AMD Opteron™
8216 2.4 GHz-1 MB Dual-Core Processor 2P Option Kit
NOTE: If four processors are desired,
select one 413932-B21 and one 413932-B21. |
413932-B21
|
AMD Opteron™
8214 2.2 GHz-1 MB Dual-Core Processor 2P Option Kit
NOTE: If four processors are desired,
select one 416734-B21 and one 416734-B21. |
416734-B21
|
|
Base
Memory | 1 GB REG
PC2-5300 2 x 512 MB Single Rank Kit |
| 2
GB REG PC2-5300 2 x 1 GB Single Rank Kit |
| 4
GB REG PC2-5300 2 x 2 GB Dual Rank Kit |
| 8
GB REG PC2-5300 2 x 4 GB Dual Rank Kit |
| NOTE:
Memory must be ordered in like-pairs, i.e. two of the same size. | |
NOTE:
If all four banks on a memory node are populated, the maximum memory clock speed
will be 533 MHz. If two or fewer banks on a memory node are populated, the maximum
memory clock speed will be 667 MHz. | |
|
Storage
Controllers | HP
Smart Array P800/512 BBWC Controller |
| HP
Smart Array P600/256 BBWC Controller |
|
HP Smart Array P600/512 BBWC Controller, Factory Integrated Only |
|
HP Smart Array P400/256MB Controller |
405132-B21
|
HP Smart Array P400/512MB BBWC Controller |
411064-B21
| HP
8 Internal Port SAS HBA with RAID |
| HP
Smart Array 6404/512 FIO CNTRLR |
|
|
Optical
Drives |
NOTE: Optical drives are ejectable. |
|
Slimline CD-RW/DVD-ROM 24X Combo Drive Option Kit |
|
Slimline DVD-ROM Drive (8X/24X) Option Kit (Servers) |
|
HP DVD±R/RW 8X Slim |
|
|
Step
3: Choose Additional Factory Integratable Options |
Integrated
hypervisor (iHV) |
VMware ESX Server
3i integrated hypervisor |
|
integrated VMware
ESX Server 3i 4P FIO |
480100-B21 |
integrated VMware
ESX Server 3i Enterprise 4P FIO |
464670-B21 |
NOTE:
For additional information and option kits, please see the QuickSpecs at:
https://h18000.www1.hp.com/products/quickspecs/12307_div/12307_div.html
(Worldwide) |
|
Citrix XenServer
integrated hypervisor |
|
integrated XenServer
HP Select Edition 2P/4P |
464673-B21 |
integrated XenServer
HP Enterprise Edition 2P/4P |
464674-B21 |
NOTE:
For additional information and option kits, please see the QuickSpecs
at:
https://h18000.www1.hp.com/products/quickspecs/13018_div/13018_div.html
(Worldwide) |
|
|
Step
4: Choose Additional Options for Factory Integration |
NOTE:
For additional options, please refer to the "Options" section
below. |
Options
NOTE:
Some options may not be factory integratable. Please contact your local sales
representative for additional information. | |
HP
ProLiant DL585 G2 Unique Options | AMD
Opteron™ 8224SE Dual-Core Processor (3.2 GHz, 120 Watts) 2P Option Kit |
| AMD
Opteron™ 8222 Dual-Core Processor (3.0 GHz, 95 Watts) 2P Option Kit |
| AMD
Opteron™ 8222SE Dual-Core Processor (3.0 GHz, 120 Watts) 2P Option Kit |
448184-B21 | AMD
Opteron™ 8220, Dual-Core Processor (2.8 GHz, 95 Watts) 2P Option Kit |
439728-B21 | AMD
Opteron™ 8220SE, Dual-Core Processor (2.8 GHz, 120 Watts) 2P Option Kit |
413934-B21 | AMD
Opteron™ 8218 Dual-Core Processor (2.6 GHz, 95 Watts) 2P Option Kit |
413933-B21 | AMD
Opteron™ 8216 Dual-Core Processor (2.4 GHz, 95 Watts) 2P Option Kit |
413932-B21 | AMD
Opteron™ 8214 Dual-Core Processor (2.2 GHz, 95 Watts) 2P Option Kit |
416734-B21 | AMD
Opteron™ 8212 Dual-Core Processor (2.0 GHz, 95 Watts) 2P Option Kit |
413931-B21 |
|
HP
Insight Control Environment Management Suite | NOTE:
Electronic licensing options are available for Insight Control suites software
products. Please see the appropriate Insight Control QuickSpecs for additional
information. | |
HP Insight Control
Environment |
|
HP Insight Control Environment, No Media 1-Server License including 1 year
of 24x7 Technical Support and Updates NOTE:
This part number can be purchased as a single license or as multiple licenses
with a single activation key. Customer will receive a license entitlement certificate
via e-mail. The license entitlement certificate must be redeemed online or via
fax in order to obtain the license activation key(s). Includes one year of 24
x 7 HP Software Technical Support and Update Service. Only available directly
from HP and select resellers in the Americas region. |
452148-B22 | HP
Insight Control Management Software Media Kit NOTE:
Insight Control Management DVD media without licenses. Contains Insight Manager
and Essentials software products and components licensed by Insight Control Management
suites. Uses an integrated installer to perform quick and accurate software installation
and updates. |
436222-B21 | NOTE:
For additional License Kits, please see the QuickSpecs at: https://h18000.www1.hp.com/products/quickspecs/12631_div/12631_div.html | |
HP Insight Control
Linux Edition | |
HP
Insight Control Environment for Linux v2.0, Media pack (CD) - No licenses included
NOTE: This optional Media pack CD contains the ISO image for HP Insight
Control Environment for Linux, HP System Insight Manager, and an integrated installer.
Servers must be acquired separately. This Media pack is optional because the latest
ISO image and latest updates may be downloaded at no cost from: https://www.hp.com/go/ice-linux
(click on Download button). | 464422-B21 |
HP
Insight Control Environment for Linux v2.0, No Media, 1-Server license, including
One year of 24x7 Technical Support and Updates NOTE: This part
number can be used to purchase one (1) license with a single activation key. Customer
will receive a printed license entitlement certificate via physical shipment.
The license entitlement certificate must be redeemed online or via fax in order
to obtain the license activation key(s). Includes one year of 24 x 7 HP Software
Technical Support and Update Service. One certificate is shipped for each license. | 464423-B21 |
NOTE:
For additional License Kits, please see the QuickSpecs at: https://h18000.www1.hp.com/products/quickspecs/13019_div/13019_div.html
| |
|
Server
Management Stand Alone Software Product - ProLiant Essentials | NOTE:
Electronic licensing options are available for select ProLiant Essentials software
products. Please see the appropriate ProLiant Essentials QuickSpecs for additional
information. | |
Deploy | |
HP Server Migration
Pack - Universal Edition | | HP
Server Migration Pack - Universal Edition, No Media, Physical / Virtual to ProLiant
Single Migration License, including 1 year of 24x7 Technical Support and Updates NOTE:
This license allows 1 physical to ProLiant or virtual to ProLiant migration.
Customer will receive a printed license entitlement certificate and documentation
via physical shipment. The license entitlement certificate must be redeemed online
or via fax in order to obtain the license activation key(s). Includes one year
of 24 x 7 HP Software Technical Support and Update Service. | 460750-B21 | HP
Server Migration Pack - Universal Edition, No Media, Physical / Virtual to Virtual
Single Migration License, including 1 year of 24x7 Technical Support and Updates NOTE:
This license allows 1 physical to virtual or virtual to virtual migration.
Customer will receive a printed license entitlement certificate and documentation
via physical shipment. The license entitlement certificate must be redeemed online
or via fax in order to obtain the license activation key(s). Includes one year
of 24 x 7 HP Software Technical Support and Update Service. | 460753-B21 | HP
Server Migration Pack - Universal Edition, No Media, 1-Year Unlimited Migration
License, including 1 year of 24x7 Technical Support NOTE:
This license allows unlimited migrations (physical to ProLiant, physical
to virtual, virtual to virtual, and virtual to ProLiant) for one year. Customer
will receive a printed license entitlement certificate and documentation via physical
shipment. The license entitlement certificate must be redeemed online or via fax
in order to obtain the license activation key(s). Includes one year of 24 x 7
HP Software Technical Support Service | 460756-B21 | NOTE:
For additional License Kits, please see the QuickSpecs at: https://h18000.www1.hp.com/products/quickspecs/12855_div/12855_div.html | |
Control | | HP
Integrated Lights-Out Select Pack | | HP
ProLiant Essentials Integrated Lights-Out Select Pack, No Media, 1-Server License NOTE:
For additional License Kits, please see the QuickSpecs at: https://h18000.www1.hp.com/products/quickspecs/12362_div/12362_div.html | 452158-B21 |
HP Integrated
Lights-Out Advanced Pack |
| HP
Integrated Lights-Out Advanced Pack, No Media ,1 Server License
NOTE: For additional License Kits, please see the QuickSpecs at: https://h18000.www1.hp.com/products/quickspecs/10861_div/10861_div.html |
452141-B21 | Optimize | |
HP Accelerated
iSCSI Pack | |
HP
ProLiant Essentials Accelerated iSCSI Pack, No Media, Single License NOTE:
For use with a single NIC port. Contains one license with a unique license
activation key and documentation. | 452679-B21 | NOTE:
For additional License Kits, please see the QuickSpecs at: https://h18000.www1.hp.com/products/quickspecs/12466_div/12466_div.html | | NOTE:
Flexible and volume quantity license kits are available for ProLiant Essentials
Value Packs. Refer to: https://www.hp.com/servers/proliantessentials
or the various ProLiant Essentials QuickSpecs for more information. | |
|
Processors | AMD Opteron™
8356, Quad-Core Processor (2.3 GHz, 75W ACP) 2P Option Kit NOTE:
Upgrading to 8300 series processors requires that all processors in the system
be matched. The VRMs included in this kit are not used on the G2; however, existing
system VRMs are compatible and additional compatible VRM kits may be ordered.
See the 'VRM Kit' section of the QuickSpecs for details. | 448193-B21 |
AMD Opteron™ 8354, Quad-Core
Processor (2.2 GHz, 75W ACP) 2P Option Kit NOTE:
Upgrading to 8300 series processors requires that all processors in the system
be matched. The VRMs included in this kit are not used on the G2; however, existing
system VRMs are compatible and additional compatible VRM kits may be ordered.
See the 'VRM Kit' section of the QuickSpecs for details. | 448192-B21 |
AMD Opteron™ 8224SE Dual-Core
Processor (3.2 GHz, 120 Watts) 2P Option Kit | 458932-B21 |
AMD Opteron™ 8222 Dual-Core
Processor (3.0 GHz, 95 Watts) 2P Option Kit | 458933-B21 |
AMD Opteron™ 8222SE Dual-Core
Processor (3.0 GHz, 120 Watts) 2P Option Kit | 448184-B21 |
AMD Opteron™ 8220 Dual-Core
Processor (2.8 GHz, 95 Watts) 2P Option Kit | 439728-B21 |
AMD Opteron™ 8220SE Dual-Core
Processor (2.8 GHz, 120 Watts) 2P Option Kit | 413934-B21 |
AMD Opteron™ 8218 Dual-Core
Processor (2.6 GHz, 95 Watts) 2P Option Kit | 413933-B21 |
AMD Opteron™ 8216 Dual-Core
Processor (2.4 GHz, 95 Watts) 2P Option Kit | 413932-B21 |
AMD Opteron™ 8214 Dual-Core
Processor (2.2 GHz, 95 Watts) 2P Option Kit | 416734-B21 |
AMD Opteron™ 8212 Dual-Core
Processor (2.0 GHz, 95 Watts) 2P Option Kit | 413931-B21 |
|
Diskette
Drive | Slimline Floppy Diskette
Drive Option Kit NOTE: Ejectable drive. |
390164-B21 |
|
Optical
Drives | Slimline CD-RW/DVD-ROM
Combo Drive Option Kit | | Slimline
DVD-ROM Drive (8X/24X) Option Kit (Servers) | 264007-B21 |
HP DVD±R/RW 8X Slim | 383975-B21 |
|
VRM
Kit | HP DL385G2/DL585G2 VRM Kit
NOTE: This kit is only required when purchasing
8300 series upgrade kits for systems where existing VRMs are not installed. Two
VRM kits are necessary for each 2P option kit. |
453059-B21 |
|
DL585 G2 Hard Drives | SFF
SAS Hard Disk Drives Hot Plug | |
HP 146 GB 3G SAS 10K SFF SP HDD |
| HP
72 GB 3G SAS 10K SFF SP HDD |
| HP
72 GB 3G SAS 15K SFF SP HDD |
| HP
36 GB 3G SAS 15K SFF SP HDD |
| NOTE:
Please see the QuickSpecs for Technical Specifications such as capacity, height,
width, interface, transfer rate, seek time, physical configuration, and operating
temperature: https://h18000.www1.hp.com/products/quickspecs/12244_div/12244_div.html
(Worldwide) | | SATA
Hot Plug Entry (ETY) Drives | | HP
120 GB 1.5 G SATA 5.4K SFF ETY HDD | 458924-B21 | NOTE:
SATA drives have a 1 year warranty. Please see the QuickSpecs for Technical Specifications
such as capacity, height, width, interface, transfer rate, seek time, physical
configuration, and operating temperature: https://h18000.www1.hp.com/products/quickspecs/13021_div/13021_div.html
(Worldwide) | | SFF
SATA Hot Plug | | HP
120GB 1.5G SATA 5.4K SFF HDD | 431786-B21 | NOTE:
SATA drives have a 1 year warranty. Please see the SATA Hard Drive QuickSpecs
for Technical Specifications such as capacity, height, width, interface, transfer
rate, seek time, physical configuration, and operating temperature: https://h18000.www1.hp.com/products/quickspecs/11940_div/11940_div.html
(Worldwide) | |
|
Storage Controllers | SCSI
Controllers for External Drive/Storage Support | |
Smart Array 6402/128 Controller |
| Smart
Array 6404/256 Controller | 273914-B21 |
Smart Array 642 Controller |
| 128-MB
BBWC (Battery-Backed Write Cache) Enabler NOTE: This 128MB BBWC
supports the Smart Array 642 Controller. |
| 64-Bit/133-MHz
Single Channel Ultra320 SCSI HBA G2 |
| SCSI
HBA | |
HP SC11Xe Host Bus Adapter |
| NOTE:
Please see the following QuickSpecs for Technical Specifications and additional
information: https://h18000.www1.hp.com/products/quickspecs/11587_div/11587_div.html
(Smart Array 6400 Series) https://h18000.www1.hp.com/products/quickspecs/12069_div/12069_div.html (Smart
Array 642) https://h18000.www1.hp.com/products/quickspecs/11943_div/11943_div.html (U320
SCSI G2 HBA) https://h18000.www1.hp.com/products/quickspecs/12566_div/12566_div.html
(SC11Xe HBA) | |
SAS
Controller | |
Smart Array E500 Controller |
| HP
Smart Array E500/256 MB Controller |
| HP
SA-P400 and SA-E500 24 In Battery Cable Kit NOTE:
This option kit contains a 24" battery cable and adhesive material for installing
a batter into the server if a Smart Array E500 is integrated outside of the factory.
For all solutions, please refer to the server QuickSpecs and User's Manual for
detailed installation instructions. | |
Smart Array P400 Controller | |
HP Smart Array P400/256 MB Controller
NOTE: The Smart Array P400 Controller supports internal Serial Attached
SCSI and Serial ATA drives. It is supported in all HP ProLiant DL585 G2 Models.
| |
HP Smart Array P400/512 MB BBWC
Controller NOTE: The Smart Array P400
Controller supports internal Serial Attached SCSI and Serial ATA drives. It is
supported in all HP ProLiant DL585 G2 Models. |
| 512
MB DDR BBWC Upgrade NOTE: For Smart
Array P400 Controller only. NOTE: If you install the 512MB DDR BBWC
as an upgrade to a Smart Array P400/256MB Controller, you must also order part
417836-B21 (HP SA-P400 and SA-E500 24 In Battery Cable Kit). |
| Battery-backed
write cache upgrade NOTE: For Smart
Array P400 Controller only. NOTE: If you install the Battery-backed
write cache as an upgrade to a Smart Array P400/256MB Controller, you must also
order part 417836-B21 (HP SA-P400 and SA-E500 24 In Battery Cable Kit). |
| HP
SA-P400 and SA-E500 24 In Battery Cable Kit NOTE:
This option kit contains a 24" battery cable and adhesive material for installing
a batter into the server if a Smart Array P400 is integrated outside of the factory.
For all solutions, please refer to the server QuickSpecs and User's Manual for
detailed installation instructions. | |
Smart Array P600 Controller |
| HP
Smart Array P600/256 BBWC Controller NOTE:
The Smart Array P600 Controller supports internal and external Serial Attached
SCSI and Serial ATA drives. It is supported in all HP ProLiant DL585 G2 Models. |
| 512
MB DDR BBWC Upgrade NOTE: For Smart
Array P600 Controller only. |
| Smart
Array P800 Controller | |
HP Smart Array P800/512 BBWC
Controller | |
NOTE: Please
see the following Controller QuickSpecs for Technical Specifications and additional
information: https://h18000.www1.hp.com/products/quickspecs/12700_div/12700_div.html
(Smart Array E500 Controller) https://h18000.www1.hp.com/products/quickspecs/12400_div/12400_div.html
(Smart Array P400 Controller) https://h18000.www1.hp.com/products/quickspecs/12247_div/12247_div.html
(Smart Array P600 Controller) https://h18000.www1.hp.com/products/quickspecs/12616_div/12616_div.html
(Smart Array P800 Controller) | |
SAS HBA | |
HP SC44Ge Host Bus Adapter |
| HP
8 Internal Port SAS HBA with RAID |
|
NOTE: Please see the following QuickSpecs
for additional information: https://h18004.www1.hp.com/products/quickspecs/12617_div/12617_div.html
(SC44Ge HBA) https://h18004.www1.hp.com/products/quickspecs/12332_div/12332_div.html (SAS
HBA) | |
|
Communications | HP
NC110T PCI Express Gigabit Server Adapter |
| HP
NC360T PCI Express Dual Port Gigabit Server Adapter |
| HP
NC364T PCI Express Quad Port Gigabit Server Adapter NOTE:
There is a maximum of five NC364T PCI Express Quad Port Gigabit Server Adapter
NICs allowed in this server. |
| HP
NC373F PCI Express Multifunction Gigabit Server Adapter |
|
HP NC373T PCI Express Multifunction Gigabit Server Adapter |
| HP
NC380T PCI Express Dual Port Multifunction Gigabit Server Adapter NOTE:
Supported on a full length-full height slot only. |
| HP
NC510C PCIe 10 Gigabit Server Adapter NOTE:
A minimum of 1 gigabyte (1 GB) of server memory is required per each NC510C
adapter. |
| HP
NC510F PCIe 10 Gigabit Server Adapter NOTE:
A minimum of 1 gigabyte (1 GB) of server memory is required per each NC510F
adapter. |
| HP
NC7170 PCI-X Dual Port 1000T Gigabit Server Adapter |
|
|
HPC Specific Options
|
HP IB 4X SDR PCI-e single PORT
HCA |
|
HP IB 4X DDR PCI-e Single PORT
HCA |
|
HP IB 4X DDR PCI-e Dual Port HCA
|
|
HP IB 4X DDR Conn-X PCI-e Dual
Port HCA |
|
HP IB 4X DDR PCI-e DUAL PORT 0
mem HCA |
483513-B21
|
|
Redundant
Options | 910W (low line), 1300W
(high line) Hot Plug Redundant Power Supply US - includes Nema 5-15P to IEC320-C19
power cord |
348114-001 | 910W
(low line), 1300W (high line) Hot Plug Redundant Power Supply - includes C14 to
C19 IEC power jumper cable | 348114-B21 |
NOTE: If you
require a local power cord, please check the Power Specifications below for the
appropriate country-specific power cord, or consult the Power Cord Matrix: https://www.hp.com/go/powercordmatrix. | |
|
Tape Drives | NOTE:
For the complete listing of Tape Drive offerings, please see: https://www.hp.com/products1/storage/compatibility/tapebackup/ISS/index.html For
recommended tape drive offerings for this ProLiant server see the following: |
| USB
Tape Drives | |
HP StorageWorks 1U USB Rack-Mount
Kit with one DAT 160 USB drive |
AG703A | SAS
Tape Drives NOTE: For the DL585
G2, HP recommends purchasing the HP SC44Ge HBA ( 416096-B21) for a dedicated SAS
HBA for tape. |
| HP
StorageWorks LTO-2 Ultrium 448 SAS Internal Tape Drive
NOTE: HP recommends combining this tape drive with the 1U SAS Rack-Mount
kit (AE459A) for a complete rack-mount solution. |
DW085A | HP
StorageWorks LTO-3 Ultrium 920 SAS Internal Tape Drive
NOTE: HP recommends combining this tape drive with the 1U SAS Rack-Mount
kit (AE459A) for a complete rack-mount solution. |
EH847A | HP
StorageWorks 1U SAS Rack-mount kit with one LTO-4 Ultrium 1760 | EH946A | HP
StorageWorks LTO-4 Ultrium 1840 SAS Internal Tape Drive NOTE:
HP recommends combining this tape drive with the 3U SAS Rack-Mount kit (AG576A)
for a complete rack-mount solution. |
EH860A | NOTE:
Please refer to the "Tape Drives, Tape Autoloaders & Tape Libraries"
table in the Storage section of this document for a list of SAS controllers with
tape support. | | SCSI
Tape Drives | | NOTE:
For the DL585 G2, HP recommends purchasing the HP SC11Xe HBA ( 412911-B21)
for a dedicated SCSI HBA for tape. | | HP
StorageWorks 1U SCSI Rack-mount kit with one LTO-2 Ultrium 448 (Carbonite) |
DW028B | HP
StorageWorks 1U SCSI Rack-mount kit with one LTO-3 Ultrium 920 |
EH903A | HP
StorageWorks 3U SCSI Rack-Mount with 1 LTO-4 Ultrium 1840 Tape Drive |
EH926A | NOTE:
Please see the HP StorageWorks Ultrium Tape Drive QuickSpecs for additional
options such as controllers, media, and other related items: https://h18006.www1.hp.com/products/quickspecs/11739_div/11739_div.html (Worldwide)
https://h18006.www1.hp.com/products/quickspecs/12128_div/12128_div.html (Worldwide) For
an up-to-date listing of the latest O/S and software support details for HP Ultrium
tape drives, please visit: https://www.hp.com/go/connect | |
Rack-Mount Tape Drive Enclosures |
| HP
StorageWorks 1U SCSI Rack-Mount kit NOTE:
The 1U Rack-Mount Kit can support up to (2) half-height tape drives and is compatible
with multiple Single-Ended and LVD SCSI tape drives including the DAT 40, DAT
72, DAT 160, DLT VS160, LTO-1 Ultrium 232, LTO-2 Ultrium 448, LTO-3 Ultrium 920
and LTO-4 Ultrium 1760 tape drives. |
| HP
StorageWorks 1U USB Rack-Mount Kit NOTE:
The 1U USB Rack-Mount Kit can support up to (2) half-height tape drives and
is compatible with the DAT 40 USB, DAT 72 USB and DAT 160 tape drives. |
| HP
StorageWorks 1U SAS Rack-Mount Kit NOTE:
The 1U SAS Rack-Mount Kit can support up to (2) half-height tape drives and is
compatible with the DAT 160 SAS, LTO-2 Ultrium 448 SAS, LTO-3 Ultrium 920 SAS
and LTO-4 Ultrium 1760 SAS tape drives. |
AE459A | HP
StorageWorks 3U Rack-mount kit NOTE:
The 3U Rack-mount Kit can support up to (2) full-height or (4) half-height tape
drives and compatible with multiple LVD SCSI tape drives including DAT 40, DAT
72, DLT VS160, SDLT 600, LTO-1 Ultrium 232, LTO-2 Ultrium 448, LTO-3 Ultrium 920,
LTO-3 Ultrium 960, LTO-4 Ultrium 1760 and LTO-4 Ultrium 1840 tape drives. |
274338-B22 | HP
StorageWorks 3U SAS Rack-mount Kit NOTE:
The 3U Rack-mount Kit can support up to (2) full-height or (4) half-height tape
drives and compatible with multiple SAS tape drives including DAT 160 SAS, LTO-2
Ultrium 448 SAS, LTO-3 Ultrium 920 SAS, LTO-4 Ultrium 1760 SAS and LTO-4 Ultrium
1840 SAS tape drives. |
AG576A | NOTE:
Please see the Rack-Mount Tape Drive Kits QuickSpecs for additional information
regarding these kits: https://h18000.www1.hp.com/products/quickspecs/10854_div/10854_div.html
(Worldwide) |
|
|
Disk-Based
Backup | RDX Removable Disk Backup |
| HP
StorageWorks RDX160 External Removable Disk Backup System NOTE:
160GB of Disk Storage. |
AJ766A | HP
StorageWorks RDX320 External Removable Disk Backup System NOTE:
320GB of Disk Storage. |
AJ768A | NOTE:
Please see the HP RDX Removable Disk Backup System QuickSpecs for additional information: https://h18000.www1.hp.com/products/quickspecs/13036_div/13036_div.html |
| D2D
Backup | | HP
StorageWorks D2D120 Backup System NOTE:
2TB of Disk Storage. | EH884A | HP
StorageWorks D2D120 Backup System with Data Protector Express Software Kit NOTE:
2TB of Disk Storage. | EH924A |
HP StorageWorks D2D130 Backup
System NOTE: 3TB of Disk Storage. |
EH950A | HP
StorageWorks D2D130 Backup System with Data Protector Express Software Kit
NOTE: 3TB of Disk Storage. |
EH951A | HP
StorageWorks D2D130 Backup System with LTO-3 Ultrium 920 SAS Tape Drive
NOTE: 3TB of Disk Storage. |
EH952A | HP
StorageWorks D2D2503i Backup System NOTE:
3TB of Disk Storage. | | HP
StorageWorks D2D4004i Backup System NOTE:
4.5TB of Disk Storage. | |
NOTE: Please
see the HP D2D Backup Systems QuickSpecs for additional information: https://www.hp.com/go/d2d. |
|
|
Tape Autoloaders | HP StorageWorks
DAT Autoloader |
| HP
StorageWorks DAT 72x10 tape autoloader |
AE313B | HP
StorageWorks 1/8 G2 Tape Autoloader |
| HP
StorageWorks 1/8 G2 LTO-4 Ultrium 1760 SAS Tape Autoloader |
AK377A | HP
StorageWorks 1/8 G2 LTO-4 Ultrium 1760 SCSI Tape Autoloader | AJ816A |
HP StorageWorks 1/8 G2 LTO-3
Ultrium 920 Tape Autoloader | AH165A |
HP StorageWorks 1/8 G2 LTO-3
Ultrium 920 SAS Autoloader | AH558A |
HP StorageWorks 1/8 G2 LTO-2
Ultrium 448 Tape Autoloader | AH164A |
HP StorageWorks 1/8 G2 Tape Autoloader
Rack Kit NOTE: Required to install
the 1/8 G2 Autoloaders in a standard 19-inch rack; includes rails and rackmount
instructions |
AH166A | NOTE:
Please reference the Tape Autoloader QuickSpecs at: https://www.hp.com/go/automation
for additional information needed to create a complete solution. |
|
|
Tape
Libraries | HP StorageWorks MSL2024
Tape Library | |
HP StorageWorks MSL2024 1 LTO-4
Ultrium 1840 SCSI Drive Library | AJ033A |
HP StorageWorks MSL2024 1 LTO-4
Ultrium 1840 4GB FC Library | AJ034A |
HP StorageWorks MSL2024 1 LTO-4
Ultrium 1760 SAS Drive Library | AK378A | HP
StorageWorks MSL4048 2 LTO-4 Ultrium 1760 SCSI Drive Library | AJ818A |
HP StorageWorks MSL2024 1 LTO-3
Ultrium 960 SCSI Drive Library | AG115A |
HP StorageWorks MSL2024 1 LTO-3
Ultrium 960 4GB FC Library | AG326B |
HP StorageWorks MSL2024 1 LTO-3
Ultrium 920 SAS Drive Library | AH559A |
HP StorageWorks MSL2024 1 LTO-3
Ultrium 920 SCSI Drive Library | AH169A |
HP StorageWorks MSL2024 1 LTO-2
Ultrium 448 SCSI Drive Library | AG116A |
HP StorageWorks MSL4048 Tape
Library | |
HP StorageWorks MSL4048 1 LTO-4
Ultrium 1840 SCSI Drive Library | AJ035A |
HP StorageWorks MSL4048 1 LTO-4
Ultrium 1840 4GB FC Library | AJ036A |
HP StorageWorks MSL4048 2 LTO-4
Ultrium 1760 SAS Drive Library | AK380A | HP
StorageWorks MSL2024 1 LTO-4 Ultrium 1760 SCSI Drive Library | AJ817A |
HP StorageWorks MSL4048 1 LTO-3
Ultrium 960 SCSI Drive Library | AG322A |
HP StorageWorks MSL4048 1 LTO-3
Ultrium 960 4GB FC Library | AG324B |
HP StorageWorks MSL4048 1 LTO-3
Ultrium 920 SAS Drive Library | AH560A |
HP StorageWorks MSL4048 1 LTO-3
Ultrium 920 SCSI Drive Library | AH171A |
NOTE: Please
reference the MSL Tape Library QuickSpecs at: https://www.hp.com/go/automation
for additional information needed to create a complete solution; reference current
compatibility information at: https://www.hp.com/go/ebs. | |
|
High Availability Cluster Options | HP
Serviceguard for Linux | |
HP Serviceguard Linux for HP
ProLiant/x86 Servers Licensed per physical server Includes media and One
Year 24x7 Software Support & Updates | 463831-B21 |
HP Serviceguard Linux Oracle
Database Toolkit for HP ProLiant/x86 Servers Licensed per cluster Includes
media and One Year 24x7 Software Support & Updates | 463833-B21 |
HP Serviceguard Extension for
SAP on Linux for HP ProLiant/x86 Servers Licensed per physical server Includes
media and One Year 24x7 Software Support & Updates | 463834-B21 |
HP Serviceguard Linux Extended
Distance Cluster (XDC) for HP ProLiant/x86 Servers Licensed per physical server Includes
media and One Year 24x7 Software Support & Updates | 463835-B21 |
NOTE: For a detailed
list of supported configuration/certification options for HP Serviceguard for
Linux please refer to the HP Serviceguard for Linux Certification Matrix at: https://www.hp.com/go/sglx/info
NOTE: HP Serviceguard for Linux products running on x86 platforms now include
one year of 24 x 7 Software Technical Support and Updates. Please see the Support
Information section of the HP Serviceguard for Linux QuickSpecs for details.
NOTE: For additional information including a complete list of Product Numbers
for HP Serviceguard for Linux, please see the following QuickSpecs at: https://h18000.www1.hp.com/products/quickspecs/11518_div/11518_div.html
(Worldwide) | |
|
StorageWorks Options | NOTE:
The following is a list of all Fibre Channel Host Bus Adapters for Windows and
Linux. For detailed compatibility information please see: https://h18006.www1.hp.com/storage/saninfrastructure/hba.html | |
HP StorageWorks FC2142SR 4Gb
PCI-e HBA | A8002A |
HP StorageWorks FC2242SR Dual
Channel 4 Gb PCI-e HBA | A8003A |
HP StorageWorks FC1142SR 4Gb
PCI-e HBA | AE311A |
HP StorageWorks FC1242SR Dual
Channel 4 Gb PCI-e HBA | AE312A |
HP StorageWorks FC2143 4Gb PCI-X
2.0 -to-Fibre Channel HBA | AD167A |
HP StorageWorks FC2243 Dual Channel
4Gb PCI-X 2.0 HBA | AD168A |
HP StorageWorks FC1143 4Gb PCI-X
2.0 HBA | AB429A |
HP StorageWorks FC1243 Dual Channel
4Gb PCI-X 2.0 HBA | AE369A |
HP StorageWorks 81Q PCI-e FC
HBA | AK344A | HP
StorageWorks 8Gb Simple SAN Connection Kit | AK241A |
|
HP
StorageWorks Modular Smart Array 30 | HP
StorageWorks Modular Smart Array 30 SB NOTE:
Rack-mountable 14 drive enclosure with single bus, redundant power supplies | 302969-B21 |
HP StorageWorks Modular Smart
Array 30 DB NOTE: Rack-mountable 14
drive enclosure with dual bus, redundant power supplies | 302970-B21 |
NOTE: Please
see the Modular Smart Array 30 QuickSpecs for additional information including
configuration steps and additional options needed for a complete solution at:
https://h18000.www1.hp.com/products/quickspecs/11738_div/11738_div.html
(Worldwide) | |
|
HP StorageWorks Modular Smart Array 500
|
HP StorageWorks Modular Smart
Array 500 Generation 2
NOTE: Please see the Modular Smart
Array 500 Generation 2 QuickSpecs for additional information including configuration
steps and additional options needed for a complete solution at:
https://h18000.www1.hp.com/products/quickspecs/11956_div/11956_div.html
(Worldwide)
|
335880-B21
|
|
Uninterruptible Power Systems – Rack | HP,
R1.5kVA UPS, 1U, NA | AF419A |
HP, R1.5kVA UPS, 1U, INTL |
AF418A | HP,
R1.5kVA UPS, 1U, JPN/TW | AF421A |
HP R3000 VA UPS, 2U, DTC, INTL | AF414A |
HP R3000 VA UPS, 2U, L5-30, NA | AF422A |
HP R3000 VA UPS, 2U, L6-20, NA | AF423A |
HP R3000 VA UPS, 2U, L6-20, JPN | AF424A |
HP R3000 VA UPS, 2U, L5-30, JPN | AF425A |
HP R5500 VA UPS, INTL |
AF416A | HP
R5500 VA UPS, NA/JPN | AF426A |
|
HP Monitored Power Distribution Unit (PDU) | HP
Monitored Power Distribution Unit: Full Rack Version |
| HP
17.3 kVA S2324 Monitored PDU dual input, 3U, 24A (NA/JPN) |
AF503A | HP
8.3 kVA S1324 Monitored PDU single input, 3U, 24A (NA/JPN) |
AF504A | HP
16.6 kVA S2140 Monitored PDU dual input, 1U, 40A (NA/JPN) |
AF505A | HP
8.6 S1140 Monitored PDU single input, 1U, 40A (NA/JPN) |
AF506A | HP
22.1 kVA S2316 Monitored PDU dual input, 3U, 16A (INTL) |
AF507A | HP
11 kVA S1316 Monitored PDU single input, 3U, 16A (INTL) |
AF508A | HP
14.7 kVA S2132 Monitored PDU dual input, 1U, 32A (INTL) |
AF509A | HP
7.3kVA S1132 Monitored PDU single input, 1U, 32A (INTL) |
AF510A | HP
Monitored Power Distribution Unit: Half Rack Version |
| HP
17.3 kVA S348 Monitored PDU- single input, 3Ø, 48A (NA/JPN) |
| HP
22 kVA S332 Monitored PDU single input, 3-phase, 32A (INTL) |
AF917A | HP
4.9kVA S124 Monitored PDU single input, 1U, 24A (NA/JPN) |
AF914A | HP
7.3kVA S132 Monitored PDU single input, 1U, 32A (INTL) |
AF915A |
|
Modular Power Distribution Units 1U/0U
(Up to 32 outlets)
NOTE: 1U/0U mounting brackets
shipped with
the unit (optimized for 10000 and 9000 series racks).
|
HP Modular Power Distribution
Units (mPDU), Low Volt Model, 24A (100-127 VAC) (NA, Japan)
NOTE: This mPDU ( 252663-D71) may
also be used to connect the low volt model of the UPS R3000 XR. |
|
HP Modular Power Distribution
Units (mPDU), High Volt Model, 24A (200-240 VAC) (NA, Japan) |
|
HP Modular Power Distribution
Units (mPDU), High Volt Model, 32A (200-240 VAC) (Int'l) |
252663-B31
|
HP Modular Power Distribution
Units (mPDU), High Volt Model, 40A (200-240 VAC) (WW)
NOTE: This mPDU ( 252663-B21), 40A
model has a hardwired input. |
|
HP Modular Power Distribution Units (mPDU), High Volt Model, 16A (200-240
VAC) (WW)
NOTE: This PDU has a detachable
input power cord and allows for adaptability to country specific power
requirements. This model may also be used with the high volt UPS R3000
XR. For North America, need to order cable PN 340653-001.
|
|
NOTE: Please see
the following Modular Power Distribution Unit (Zero-U/1U Modular PDUs) QuickSpecs
for additional options including shorter jumper cables and country specific
power cords:
https://h18000.www1.hp.com/products/quickspecs/11041_div/11041_div.html
(Worldwide) |
|
|
USB
Options | HP USB 2-Button
Optical Scroll Mouse (Carbonite/Silver) | DC172B |
HP USB 04 Standard Keyboard | DT528A#xxx |
HP 1GB USB 2.0 Floppy Drive
Key | 442085-B21 |
HP 256MB USB 2.0 Floppy
Drive Key | 442084-B21 |
|
HP Rack 10000
G2 Series
(Carbon/Graphite Metallic)
|
10642 G2 (42U) Rack Cabinet
Pallet |
|
10642 G2 (42U) Rack Cabinet
Shock Pallet |
|
10642 G2 (42U) Rack Cabinet
Crated |
AF003A
|
10642 G2 (42U) Rack Cabinet, with
Extension Shock Pallet |
|
10636 G2 (36U) Rack Cabinet
Pallet |
|
10636 G2 (36U) Rack Cabinet
Shock Pallet |
|
10636 G2 (36U) Rack Cabinet
Crated |
|
10636 G2 (36U) Rack Cabinet, with
Extension Shock Pallet |
|
10622 G2 (22U) Rack Cabinet -
Pallet |
AF021A
|
10622 G2 (22U) Rack Cabinet -
Shock Pallet |
AF022A
|
10842 G2 (42U) 800mm Wide Rack
Cabinet - Pallet |
AF041A
|
10842 G2 (42U) 800mm Wide Rack
Cabinet - Shock Pallet |
AF042A
|
10647 G2 (47U) Rack Cabinet -
Pallet |
AF031A
|
NOTE: It is mandatory
to use a shock pallet when shipping racks with equipment installed. |
|
NOTE: Please see
the Rack 10000 G2 QuickSpecs for Technical Specifications such as height,
width, depth, weight, and color:
https://h18000.www1.hp.com/products/quickspecs/12402_div/12402_div.html
(Worldwide) |
|
NOTE: For additional
information regarding Rack Cabinets, please see the following URL: https://www.hp.com/go/rackandpower. |
|
|
HP Rack 10000 Series (Graphite
Metallic) | HP Rack S10614
(14U) Rack Cabinet Shock Pallet |
|
NOTE: xxxxxx-B22 (shock pallet) used to ship
racks with equipment installed (by custom systems, VARs and Channels). |
|
NOTE: Please see the Rack 10000 QuickSpecs
for Technical Specifications such as height, width, depth, weight, and color:
https://h18000.www1.hp.com/products/quickspecs/10995_div/10995_div.html
(Worldwide) | |
NOTE: For
additional information regarding Rack Cabinets, please see the following URL:
https://www.hp.com/go/rackandpower. |
|
|
Keyboards and Monitors | TFT7600
Rackmount Keyboard Monitor US |
| TFT7600
Rackmount Keyboard Monitor UK |
AG053A | TFT7600
Rackmount Keyboard Monitor GR |
AG054A | TFT7600
Rackmount Keyboard Monitor FR |
AG055A | TFT7600
Rackmount Keyboard Monitor IT |
AG056A | TFT7600
Rackmount Keyboard Monitor SP |
AG057A | TFT7600
Rackmount Keyboard Monitor DEN |
AG058A | TFT7600
Rackmount Keyboard Monitor NOR |
AG059A | TFT7600
Rackmount Keyboard Monitor SE/FI |
AG060A | TFT7600
Rackmount Keyboard Monitor SWI |
AG061A | TFT7600
Rackmount Keyboard Monitor PORT |
AG062A | TFT7600
Rackmount Keyboard Monitor BEL |
AG063A | TFT7600
Rackmount Keyboard Monitor JPN2 |
AG064A | TFT7600
Rackmount Keyboard Monitor RUS |
AG065A | TFT7600
Rackmount Keyboard Monitor INTL |
AG066A | 1U
Rackmount Keyboard with USB, US |
| 1U
Rackmount Keyboard with USB, UK |
AG073A | 1U
Rackmount Keyboard with USB, GR |
AG074A | 1U
Rackmount Keyboard with USB, FR |
AG075A | 1U
Rackmount Keyboard with USB, ITL |
AG076A | 1U
Rackmount Keyboard with USB, SP |
AG077A | 1U
Rackmount Keyboard with USB, DEN |
AG078A | 1U
Rackmount Keyboard with USB, NOR |
AG079A | 1U
Rackmount Keyboard with USB, SE/FI |
AG080A | 1U
Rackmount Keyboard with USB, SWI |
AG081A | 1U
Rackmount Keyboard with USB, PORT |
AG082A | 1U
Rackmount Keyboard with USB, BEL |
AG083A | 1U
Rackmount Keyboard with USB, JPN2 |
AG084A | 1U
Rackmount Keyboard with USB, RUS |
AG085A | 1U
Rackmount Keyboard with USB, INTL |
AG086A | NOTE:
For additional information regarding Rack Options, please see the following
URL: https://www.hp.com/go/rackandpower. |
|
|
HP
KVM Switch Options | 2x1x16 IP Console
Switch with Virtual Media | |
4x1x16 IP Console Switch with
Virtual Media | |
2x16 Server Console Switch with
Virtual Media | |
PS/2 Virtual Media Interface
Adapter, 1 pack NOTE: Requires PS/2
and one USB port on server. |
| Server
Console Switch (KVM), 0 x 1 x 8 port |
| Server
Console Switch (KVM), 0 x 2 x 16 port |
| PS/2
Interface Adapter, 1 pack | |
PS/2 Interface Adapter, 8 pack |
| NOTE:
Cat5e cables are required to connect Interface Adapters to Console Switches.
Cat5e cables can be found at the following URL: https://www.hp.com/go/kvm. |
| HP
1x4 Server Switch | |
PS2 Server Console Cable, 6 ft,
2 pack | |
USB Server Console Cable, 6 ft,
2 pack | |
NOTE: For additional
information regarding KVM switches, Serial Console servers, rack mount monitors,
keyboards and all related options please see the following URL: https://www.hp.com/go/kvm.
| |
|
HP
Serial Console Server Options | HP
16 Port Serial Console Server (worldwide) |
| HP
48 Port Serial Console Server (worldwide) |
| Serial
Adapter, RJ45-DB9 DCE Female, 1 Pack |
| Serial
Adapter, RJ45-DB9 DCE Female, 8 Pack |
AF110A | NOTE:
Cat5e cables are required to connect Serial Adapters to Serial Console Servers.
Additional Serial Adapters and Cat5e cables can be found at the following URL:
https://www.hp.com/go/kvm. | |
NOTE: For additional
information regarding KVM switches, Serial Console servers, rack mount monitors,
keyboards and all related options please see the following URL: https://www.hp.com/go/kvm. | |
|
Service
and Support Offerings (HP Care Pack Services) |
Hardware Services On-site Service |
| 4-Hour
On-site Service, 5-Day x 13-Hour Coverage, 3 Years, Electronic |
U4607E | 4-Hour
On-site Service, 7-Day x 24-Hour Coverage, 3 Years, Electronic |
U4608E | Hardware
Services 6-Hour Call to Repair On-site Service |
| 6-Hour
Call to Repair, On-site Service, 7-Day x 24-Hour Coverage, 3 Years, Electronic |
U4609E | Installation
& Start-up Services | | Hardware
Installation, Electronic | U4617E | Installation
& Start-Up of a ProLiant server and Microsoft or Linux O/S per the Customer
Description and/or Data Sheet. To be delivered on a scheduled basis 8am-5pm, M-F,
excl. HP holidays, Electronic |
U4618E | Support
Plus | | Onsite
HW support, 8am-9pm, M-F, 4hr response and Microsoft O/S SW Tech support offsite,
onsite at HP's discretion, 8am-9pm, M-F 2hr response time excl. HP holidays, Electronic |
U4619E | Support
Plus 24 | |
Onsite HW support 24x7, 4hr response
and Microsoft O/S SW Tech support offsite, onsite at HP's discretion, 24x7 2hr
response time incl. HP holidays, Electronic |
U4620E | Onsite
HW support 24x7, 4hr response and SuSE Linux SW Tech support offsite, onsite at
HP's discretion, 24x7 2hr response time incl. HP holidays, Electronic |
U6316E | Onsite
HW support 24x7, 4hr response and Red Hat AS Linux SW Tech support offsite, onsite
at HP's discretion, 24x7 2hr response time incl. HP holidays, Electronic |
U9239E | NOTE:
For more information, customer/resellers can contact: https://www.hp.com/services/carepack. | |
Memory
NOTE:
Memory configurations listed do not apply to "Factory Integrated Models." |
HP ProLiant DL585
G2 2P Models |
Standard Memory 4 GB PC2-5300 Double Data Rate
2 (DDR2) SDRAM (Registered SDRAM) memory running at 667 MHz or 2 GB PC2-5300
Double Data Rate 2 (DDR2) SDRAM (Registered SDRAM) memory running at 667 MHz with
Advanced ECC At least one pair of DIMMs must be installed
in slots 1A and 2A to operate the server. Observe the following DIMM installation
guidelines to add additional memory to the server:
- DIMMs must be installed in pairs.
- DIMM
installed on the same memory bank must have the same part number.
- DIMMs
installed in different banks can be of different sizes.
- DIMMs
must be installed in decreasing capacity with the largest DIMMs installed in the
banks furthest away from each processor.
- DIMM banks are active
only when the corresponding processor socket is populated.
NOTE:
If all four banks on a memory node are populated, the maximum memory clock speed
will be 533 MHz. If two or fewer banks on a memory node are populated, the maximum
memory clock speed will be 667 MHz. | |
The
following memory options are available from HP: | 1
GB REG PC2-5300 2 x 512 MB Single Rank Kit | 408850-B21 |
2 GB REG PC2-5300
2 x 1 GB Single Rank Kit | 408851-B21 |
4 GB REG PC2-5300
2 x 2 GB Dual Rank Kit | 408853-B21 |
8 GB REG PC2-5300
2 x 4 GB Dual Rank Kit | 408854-B21 |
|
Standard
Memory Configuration (2.0GHz, 2.2GHz and 2.4GHz models) Total Memory
= 2 GB |
|
1 (Slot furthest from processor) |
2 |
3 |
4 |
5 |
6 |
7 |
8 (Slot closest to processor) |
Processor 1
Memory Bus |
512 MB |
512 MB |
Empty |
Empty |
Empty |
Empty |
Empty |
Empty | Processor
2 Memory Bus | 512
MB | 512
MB | Empty |
Empty |
Empty |
Empty |
Empty |
Empty | Processor
3 Memory Bus | Empty | Empty | Empty | Empty | Empty | Empty | Empty | Empty |
Processor
4 Memory Bus | Empty | Empty | Empty | Empty | Empty | Empty | Empty | Empty |
|
Standard
Memory Configuration (2.6GHz model) Total Memory = 4 GB |
|
1 (Slot furthest from processor) |
2 |
3 |
4 |
5 |
6 |
7 |
8 (Slot closest to processor) |
Processor 1
Memory Bus |
1 GB |
1 GB |
Empty |
Empty |
Empty |
Empty |
Empty |
Empty | Processor
2 Memory Bus | 1
GB | 1
GB | Empty |
Empty |
Empty |
Empty |
Empty |
Empty | Processor
3 Memory Bus | Empty | Empty | Empty | Empty | Empty | Empty | Empty | Empty |
Processor
4 Memory Bus | Empty | Empty | Empty | Empty | Empty | Empty | Empty | Empty |
|
Standard
Memory Configuration (2.8GHz models) Total Memory = 8 GB |
|
1 (Slot furthest from processor) |
2 |
3 |
4 |
5 |
6 |
7 |
8 (Slot closest to processor) |
Processor 1
Memory Bus |
1 GB |
1 GB |
Empty |
Empty |
Empty |
Empty |
Empty |
Empty | Processor
2 Memory Bus | 1
GB | 1
GB | Empty |
Empty |
Empty |
Empty |
Empty |
Empty | Processor
3 Memory Bus | 1 GB | 1
GB | Empty | Empty | Empty | Empty | Empty | Empty |
Processor
4 Memory Bus | 1
GB | 1 GB | Empty | Empty | Empty | Empty | Empty | Empty |
Examples of other optional configurations include, but
are not limited to:
Example #1: Optional
Memory Configuration with DIMM mixing Standard Memory plus Optional Memory
and Processors Total Memory = 34 GB |
|
1 |
2 |
3 |
4 |
5 |
6 |
7 |
8 | Processor
1 Memory Bus | 2
GB | 2
GB | 1
GB | 1
GB | 512
MB | 512
MB | 512
MB | 512
MB | Processor
2 Memory Bus | 2
GB | 2
GB | 1
GB | 1
GB | 512
MB | 512
MB | 512
MB | 512
MB | Processor
3 Memory Bus | 2 GB | 2
GB | 2 GB | 2
GB | 1 GB | 1
GB | 512 MB | 512
MB | Processor
4 Memory Bus | 1
GB | 1 GB | 1
GB | 1 GB | 1
GB | 1 GB | 512
MB | 512
MB |
Example #2: Optional
Memory Configuration with Partial Bus Population Standard Memory plus
Optional Memory and Processors Total Memory = 8 GB |
|
1 |
2 |
3 |
4 |
5 |
6 |
7 |
8 | Processor
1 Memory Bus | 512 MB | 512
MB | 512 MB | 512
MB | Empty | Empty | Empty | Empty |
Processor
2 Memory Bus | 512 MB | 512
MB | 512 MB | 512
MB | Empty | Empty | Empty | Empty |
Processor
3 Memory Bus | 512 MB | 512
MB | 512 MB | 512
MB | Empty | Empty | Empty | Empty |
Processor
4 Memory Bus | 512 MB | 512
MB | 512 MB | 512
MB | Empty | Empty | Empty | Empty |
Example #3: Maximum
Memory Configuration Maximum Memory (Standard replaced with Optional
Memory) Total Memory = 128 GB |
|
1 |
2 |
3 |
4 |
5 |
6 |
7 |
8 | Processor
1 Memory Bus | 4 GB | 4
GB | 4 GB | 4
GB | 4 GB | 4
GB | 4 GB | 4
GB | Processor
2 Memory Bus | 4 GB | 4
GB | 4 GB | 4
GB | 4 GB | 4
GB | 4 GB | 4
GB | Processor
3 Memory Bus | 4 GB | 4
GB | 4 GB | 4
GB | 4 GB | 4
GB | 4 GB | 4
GB | Processor
4 Memory Bus | 4 GB | 4
GB | 4 GB | 4
GB | 4 GB | 4
GB | 4 GB | 4
GB |
Storage
|
A | Ejectable: Slimline Diskette
or Optical Drive (Optional) |
B | Ejectable: Slimline Optical
Drive (DVD/CD-RW Standard) | 1-8 | SFF
SAS Internal Drive cage |
| Drive
Support |
| |
Quantity Supported |
Position Supported |
Controller
|
Ejectable Slimline Drives | | |
| 1.44-MB slimline
Diskette Drive | Up
to 1 | A
or B Based on Boot Device Selector Switch | Integrated |
IDE slimline CD-ROM Drive | Up
to 2 | A
or B | Integrated IDE |
IDE Slimline DVD-ROM Drive (8X/24X) | Up
to 2 | A
or B | Integrated IDE |
IDE Slimline CD-RW/DVD-ROM Combo
Drive | Up
to 2 | A
or B | Integrated IDE |
IDE DVD±R/RW 8X Drive | Up
to 2 | A
or B | Integrated IDE |
|
SFF SAS Hot Plug
Drives | |
Quantity Supported |
Position Supported |
Controller
| 146GB
3G SAS 10K SP 72GB 3G SAS 10K SP 72GB 3G SAS 15K SP 36GB 3G SAS 15K SP | Up
to 8 | 1-8 | HP
Smart Array E500/256MB Controller HP Smart Array P400/256MB Controller
HP Smart Array P400/512MB BBWC Controller HP Smart Array P600/256 BBWC Controller
HP Smart Array P800/512 BBWC Controller |
|
SFF SATA Hot Plug Entry
(ETY) Drives | |
Quantity Supported |
Position Supported |
Controller
| 120GB
1.5G SATA 5.4K | Up
to 8 | 1-8 | HP
Smart Array E500/256MB Controller HP Smart Array P400/256MB Controller HP
Smart Array P400/512MB BBWC Controller HP Smart Array P600/256 BBWC Controller HP
Smart Array P800/512 BBWC Controller |
|
SFF SATA Hot Plug |
|
Quantity Supported |
Position Supported |
Controller
| 120GB
1.5G 5.4K | Up
to 8 | 1-8 | HP
Smart Array E500/256MB Controller HP Smart Array P400/256MB Controller HP
Smart Array P400/512MB BBWC Controller HP Smart Array P600/256 BBWC Controller HP
Smart Array P800/512 BBWC Controller |
|
External Storage |
| Quantity
Supported | Position
Supported |
Host Controller or Adapter
|
Modular Smart Array 30 Family |
Up to 13 |
External |
Smart Array 6402/128 Controller Smart Array 6404/256 Controller Smart
Array 642 Controller |
Modular Smart Array 50 Enclosure | 2
per connector (supports 1+1 cascading) | External
| HP Smart Array P600/256
BBWC Controller |
|
Maximum Storage Capacity (External Enclosures Attached) |
Internal | 1.168TB
(8 x 146 GB SFF SAS Drives) | External | 504TB
(56 MSA60 enclosures @ 12 drives per enclosure x 750 GB SATA Drives) |
|
| Position
Supported | Controller |
Controller Part Number | HP
StorageWorks SCSI Tape Drives, External LTO-1 Ultrium 232 LTO-2 Ultrium
448 LTO-3 Ultrium 960 LTO-3 Ultrium 920 LTO-4 Ultrium 1760 LTO-4 Ultrium
1840 DAT 40 DAT 72 DAT 160 DLT VS160 SDLT 600 1U Rack-Mount
Kit 3U Rack-Mount Kit | External |
HP SC11Xe Host Bus Adapter |
| |
| |
|
HP StorageWorks USB Tape Drives, External DAT 40 USB DAT 72
USB DAT 160 USB 1U Rack-Mount Kit |
External |
USB 2.0 Port |
N/A | | |
|
| HP
StorageWorks SAS Tape Drives, External DAT 160 SAS LTO-2 Ultrium 448
SAS LTO-3 Ultrium 920 SAS LTO-4 Ultrium 1760 SAS LTO-4 Ultrium 1840 SAS 1U
Rack-Mount Kit 3U Rack-Mount Kit |
External | HP
SC44Ge Host Bus Adapter |
| | | |
| HP
StorageWorks SCSI Tape Automation, External DAT 72x10 Autoloader 1/8 G2
Autoloader MSL2024 MSL4048 MSL8096 MSL6000 |
External | HP
SC11Xe Host Bus Adapter |
| HP
U320e SCSI Host Bus Adapter NOTE: Recommended
for MSL tape libraries. |
| |
| |
| HP
StorageWorks SAS Tape Automation, External 1/8 G2 Autoloader MSL2024 MSL4048 MSL8096 |
External | HP
SC44Ge Host Bus Adapter NOTE: Please
visit https://www.hp.com/go/connect
for details about minimum SAS controller firmware version and SAS cabling requirements. |
| | |
|
| HP
StorageWorks Fibre Tape Automation, External MSL2024 MSL4048 MSL8096 MSL6000 |
External |
|
N/A | | | | | HP
StorageWorks RDX Removable Disk Backup System, External RDX160 RDX320 | External | USB
2.0 Port | N/A |
| |
|
| HP
StorageWorks D2D Backup Systems D2D120 D2D130 D2D2503i D2D4004i |
External |
Embedded Network Controller |
N/A |
Power Specifications
Part
number | 348114-001 | Operational
Input Voltage Range
(Vrms) |
90
to 264 | Frequency
Range (Nominal) (Hz) | 47
to 63 (50/60) |
Nominal Input Voltage
(Vrms) | 100 |
115 | 208 |
220 | 230 |
240 | Max
Rated Output Wattage Rating | 910 |
910 | 1300 |
1300 | 1300 |
1300 | Nominal
Input Current (A rms) | 11.9 |
10.2 | 7.7 |
7.3 | 6.9 |
6.6 | Max
Rated Input Wattage Rating (Watts) | 1163 |
1148 | 1566 |
1566 | 1548 |
1548 | Max.
Rated VA (Volt-Amp) | 1186 |
1172 | 1598 |
1598 | 1579 |
1579 | Efficiency
(%) | 80 |
81 | 83 |
83 | 84 |
84 | Power
Factor | 0.98 |
0.98 | Leakage
Current (mA) |
0.43 |
0.50 |
0.90 |
0.96 |
1.00 |
1.04 | Max.
Inrush Current (A peak) |
100 |
100 |
100 |
100 |
100 |
100 | Max.
Inrush Current duration (mS) | 10 |
NOTE: To review typical system power ratings use the Active
Answers Power Calculator which is available via the online tool located
at url: https://h30099.www3.hp.com/configurator/powercalcs.asp
To drill down to calculators:
- Click on: "ProLiant Servers"
- Click on the Server of interest. Example: DL585 G2
- Click on: "Power Calculator" link. (You may need to scroll
down to see it)
- There are certain Dual-core, lowline, max configurations that are
not supported. All highline configurations are supported. Consult the
Power Calculator to determine if your lowline configuration is supported.
|
|
Standard Rack Model Power Cords / Jumper
Cords |
Description
|
Asia Pacific |
IEC320-C14 to IEC320-C19 Jumper Cord |
Europe |
IEC320-C14 to IEC320-C19 Jumper Cord |
Japan |
JIS C8303 to IEC320-C19
IEC320-C14 to IEC320-C19 Jumper Cord |
PRC
|
IEC320-C14 to IEC320-C19 Jumper Cord |
USA
|
IEC320-C14 to IEC320-C19 Jumper Cord |
Optional Country Power Cords and Jumper Cords
|
Description
|
Option Kit Part Number
|
Australia/New Zealand |
AS/NZS 3112 to IEC320-C19 |
305340-011
|
Denmark/Switzerland |
IEC320-C19, Industrial |
305340-081
|
Europe |
CEE 7 to IEC320-C19 |
305340-021
|
Italy |
IEC320-C19, Italy |
305340-061
|
South Africa/India |
IEC320-C19, SA |
305340-AR1
|
UK |
BS1363 to IEC320-C19 |
305340-031
|
US |
Nema 5-15P to IEC320-C19 |
235603-001
|
US |
Nema 6-20P to IEC320-C19 |
235604-001
|
US |
Nema L6-20P to IEC320-C19, 20A,
250V, US |
340653-001
|
WW |
IEC320-C19 to IEC320-C14 Jumper
(10A, IEC, 6 ft/2.0m) |
313227-B21
|
WW |
IEC320-C19 to IEC320-C14 Jumper
(10A, IEC, 8 ft/2.5m) |
291034-B21
|
WW |
IEC320-C19 to IEC320-C14 Jumper
(10A, IEC, 10 ft/3.0m) |
310927-B21
|
WW |
IEC320-C19 to IEC320-C14 Jumper
(10A, IEC, 12ft/3.7m) |
313228-B21
|
WW |
IEC320-C19 to IEC320-C20 Jumper
(16A, IEC, 8ft/2.5m) |
295633-B22
|
Quickspecs
System Unit | Dimensions
(H x W x D) (with bezel) |
6.94 x 19 x 26.5 in (17.6 x 48.3 x 67.3 cm) |
Weight (approximate) | Maximum
(all hard drives, power supplies, and processors installed) | 95
lb (43 kg) | Minimum
(one hard drive, power supply, and processor installed) | 79
lb (36 kg) |
Input Requirements (per power supply) | Rated
Line Voltage | 90 - 132 VAC,
180 - 264 VAC | Rated
Input Current | 12 A (at 100 VAC),
8 A (at 200 VAC) | Rated
Input Frequency | 47 to 63 Hz |
Rated Input Power
| 1161 W (at 100 VAC), 1598
W (at 200 VAC) | BTU
Rating | Maximum | 3985
BTU/hr (at 100 VAC), 5457 BTU/hr (at 200 VAC) | Power
Specifications |
To review typical system power ratings use the Power Calculator which is available
via the online tool located at URL: https://h30099.www3.hp.com/configurator/powercalcs.asp
- Click on the system of interest. Example: DL585 G2
- Follow the
instructions of the next screens
| Power
Supply Output (per power supply) | Rated
Steady-State Power | 910 W (at 100
VAC), 1300 W (at 200 VAC) | Maximum
Peak Power | 960 W (at 100 VAC),
1420 W (at 200 VAC) |
System Inlet Temperature
| Operating | 10°
to 35°C (50° to 95°F) at sea level with an altitude derating of 1.0°C
per every 305 m (1.8°F per every 1000 ft) above sea level to a maximum of
3050 m (10,000 ft), no direct sustained sunlight. Maximum rate of change is 10°C/hr
(18°F/hr). The upper limit may be limited by the type and number of options
installed. System performance may be reduced if operating with a fan fault
or above 30°C (86°F). | Non-operating | -30°
to 60°C (-22° to 140°F). Maximum rate of change is 20°C/hr (36°F/hr).
| Relative
Humidity (non-condensing) | Operating | 10
to 90% relative humidity (Rh), 28°C (82.4°F) maximum wet bulb temperature,
non-condensing. | Non-operating | 5
to 95% relative humidity (Rh), 38.7°C (101.7°F) maximum wet bulb temperature,
non-condensing. | Altitude | Operating | 3050
m (10,000 ft). This value may be limited by the type and number of options installed.
Maximum allowable altitude change rate is 457 m/min (1500 ft/min). |
Non-operating | 9144
m (30,000 ft). Maximum allowable altitude change rate is 457 m/min (1500 ft/min). |
Acoustic Noise
| Listed are
the declared A-Weighted sound power levels (LWAd) and declared average bystander
position A-Weighted sound pressure levels (LpAm) when the product is operating
in a 23°C ambient environment. Noise emissions were measured in accordance
with ISO 7779 (ECMA 74) and declared in accordance with ISO 9296 (ECMA 109). |
Idle | |
| L
WAd | 7.7 B | | L
pAm | 58 dBA |
Operating | |
| L
WAd | 7.7 B | | L
pAm | 58 dBA |
|
24X Max (or higher) IDE CD-ROM Drive Slim Line |
Disk | Applicable
Disk | CD-DA, CD-ROM (Mode 1 and
2) | CD-XA, CD-I (Mode
2, Form 1 and 2) | Photo
CD (Single and Multi-session) |
Mixed Mode (Audio and Data combined) |
Capacity | 540 MB (Mode 1, 12 cm)
| 650 MB (Mode 2, 12
cm) | Diameter |
4.7 x 3.15 in (12 x 8 cm) |
Rotational Speed | 4200 rpm maximum
| Center Hole |
0.6 in/15 mm diameter |
Thickness | 1.2 mm |
Track Pitch |
1.6 µm | Block
Size | Mode 1 | 2,048 |
Mode 2 | 2,340,
2,336, 1,024 bytes | CD-DA | 2,352
bytes | CD-XA | 2,328
bytes | Interface
| IDE (ATAPI) |
| Access
Times (typical) |
Random | 100 ms |
Full-Stroke | 2000 ms |
Audio Output Level | Line-Out | 0.7
Vrms at 47 kOhms | Headphone | 0.6
Vrms at 32 kOhms (maximum volume) | Data
Transfer Rate | Sustained |
150 KB/s (sustained 1X) |
Burst | 2100 to 3600 KB/s |
Cache Buffer |
128 KB | |
Start-up Time (typical) |
< 7seconds | |
Stop Time |
< 4seconds | |
Laser Parameters | Type | Semiconductor
Laser GaA1As | Wave Length | 780
± 25 nm | Divergence
Angle | 53.5° ± 1.5° |
Output Power | 0.14
mW | Operating
Conditions | Temperature |
41° to 113° F (5° to 45° C) |
Humidity | 10% to 80% |
Dimensions
| (HxWxD, maximum)
| 1.69 x 5.75 x 8.19 in (4.29 x 15
x 20.8 cm) | Weight | 2.66
lb (1.2 kg) |
|
Slimline CD-RW/DVD-ROM 24X Combo Drive | Shipping
Dimensions | 13.88 x 11.38
x 9.25 in (35.26 x 28.91 x 23.50 cm) |
Shipping Weight | 5 lb (2.27
kg) | |
Disk |
Applicable Disk |
DVD-ROM |
DVD-R (Read Only) |
2.6 GB/side DVD-RAM (Read Only) |
5.2 GB/side DVD-RAM (Read Only) |
CD-ROM Mode-1 data disc | CD-ROM
Mode-2 data disc | CD
Audio disc | CD-Extra |
CD-RW |
CD-R | CD
Text | PhotoCD |
CD-I (mode 2) |
CD-I Ready |
CD-Bridge |
Capacity |
DVD-ROM | DVD-SL | 4.7
GB/side | DVD-DL | 8.5
GB/side | Double Sided | 9.40
GB/side | DVD-R | | 3.95
GB/side | DVD-RAM | 2.6
GB/side and 5.2 GB/ | CD-ROM | Mode-1 | 650
MB (550 MB) | Mode-2 | 742
MB (640 MB) | Block
Size | DVD | | 2,048
bytes | CD | 2,352
(Mode-0) | 2352, 2340,
2336, 2048 bytes (Mode-1) | 2352,
2340, 2336, 2048 bytes (Mode-2) |
Diameter | 120
mm, 80 mm (with adapter at vertical mounting mode) | Loading
Mechanism | Tray type |
| Interface |
EIDE (ATAPI) |
| Access
Times (typical) | Random |
DVD-ROM < 120 ms, CD-ROM < 110 ms |
Full-Stroke |
DVD-ROM < 240 ms, CD-ROM < 160 ms |
Audio Output Level (typical) |
Line-out | CD
0.7 Vrms at 47 Kohms Load | Data
Transfer Rate (sustained) |
DVD-ROM | Single
Layer | 10.8 MB/sec. Max. |
DVD-RAM | 2.77
MB/sec. Max | CD-ROM |
7.2 MB/sec. Max. |
Cache Buffer | 2 MB |
| Spin-up Time
(typical) | less than 10 seconds |
| MTBF |
120,000 Power On Hours (POH) |
| Ambient Temperature |
Operating | -22°
to 140° F (-30° to 60° C) | Relative
Humidity | Operating |
10% to 80% | Storage/Transportation | 5%
to 95% | Dimensions |
(HxWxD, maximum) |
0.5 x 5.04 x 5.1 in (12.7 x 128 x 129.4 mm) | Option
Kit Contents | DVD-ROM
drive with installation guide, warranty card, registration card |
|
Integrated
Lights-Out 2 Standard (integrated on system board) | Architecture | 32-bit
PCI-based health and remote management ASIC (Application Specific Integrated Circuit) |
Processor | 32-bit
RISC processor core running at 66 MHz | Upgradeability | Option
firmware upgradeable via flash ROM | Video
Support | Utilizes the host server's
embedded video chip. Supports VGA/SVGA, 640 x 480 (256 to 16.7M colors), 800 x
600 (256 to 16.7M colors), 1024 x 768 (256 to 65K colors), 1280 x 1024 (256 colors) |
Interfaces | One
Ethernet network connection (10/100 Mb/s) | Memory | 2-MB
Flash ROM | 8-MB SDRAM |
Operating System
Support | Windows 2000 Server |
Windows 2000 Advanced Server |
Red Hat 7.x | SuSE
7.0 | Client Browser Support | Microsoft
Internet Explorer 5.5 or later. | iLO
2 Standard Features | Virtual Text
Remote Console | Virtual
KVM | Virtual Power Button
Control | Virtual UID Control |
Power Regulator Control |
Dedicated LAN Connectivity |
Secure access using web browser |
Secure access using Secure Shell
(SSH) client | Serial connectivity |
Automatic IP Configuration via
DHCP/DNS/WINS | Industry
Standard 128-bit Secure Sockets Layer (SSL) Security | IML
and iLO2 Event Logging | Support
for up to 12 user accounts with customizable access privileges |
iLO Advanced Features
(optional) | Virtual Graphical Remote
Console | Virtual Floppy/USB
Key drive | Virtual CD-ROM
drive | Directory Services
Integration | Processor
States Reporting | Terminal
Services Integration |
|
Smart Array P400 Controller
|
Disk Drive and Enclosure Interface
|
3G SAS (Serial Attached SCSI)
1.5G SATA (Serial Advanced Technology Attachment) |
SAS Connectors |
2 internal (SFF8484) x4 wide port
connectors |
Cache Memory Speed
|
DDR2-533MHz with 40 or 72-bit
wide bus provides up to 4.2 GB/s maximum bandwidth. |
Server Interface |
x8 2.5G PCIe provides 2GB/s maximum
bandwidth. |
SAS Speed |
x8 3G SAS provides 2.4GB/s maximum
bandwidth. |
Cache Memory
|
40-bit 256MB cache (72-bit 512MB
module upgrades available); ECC protection, battery-backed, and transportable |
Logical Drives Supported
|
Up to 32 logical drives |
Maximum Logical Drive Capacity |
2TB |
Host Memory Addressing |
64-bit, supporting greater than
4GB server memory space |
RAID Support |
RAID 6 with ADG (Advanced Data
Guarding) requires Battery Backed Write Cache Upgrade
RAID 5 (Distributed Data Guarding)
RAID 1, 1+0 (Striping & Mirroring)
RAID 0 (Striping) |
Upgradeable Firmware |
Upgradeable Firmware with recovery
ROM feature |
|
Two embedded NC371i Multifunction Gigabit Server Adapters | Network
Interface | 10/100/1000-T |
Compatibility | IEEE
802.3 10Base-T | IEEE
802.3ab 1000Base-T | IEEE
802.3u 100Base-TX | Data
Transfer Method | PCI Express,
four lanes (x4) | Network
Transfer Rate | 10Base-T (Half-Duplex) | 10
Mb/s | 10Base-T (Full-Duplex) | 20
Mb/s | 100Base-TX (Half-Duplex) | 100
Mb/s | 100Base-TX (Full-Duplex) | 200
Mb/s | 1000Base-TX (Half
and Full-Duplex) | 2000 Mb/s |
Connector | RJ-45 |
Cable Support | 10Base-T
| Categories 3, 4, or 5 UTP; up
to 328 ft (100 m) | 10/100/1000
Base-TX | Category 5 UTP up to
328 ft (100 m) |
|
Environment-friendly Products and Approach | End-of-life
Management and Recycling | Hewlett-Packard
offers end-of-life HP product return, trade-in, and recycling programs in many
geographic areas. For trade-in information, please go to: https://www.hp.com/go/green.
To recycle your product, please go to: https://www.hp.com/go/green
or contact your nearest HP sales office. Products returned to HP will be recycled,
recovered or disposed of in a responsible manner. The EU WEEE directive
(2002/95/EC) requires manufacturers to provide treatment information for each
product type for use by treatment facilities. This information (product disassembly
instructions) is posted on the Hewlett Packard web site at: https://www.hp.com/go/green.
These instructions may be used by recyclers and other WEEE treatment facilities
as well as HP OEM customers who integrate and re-sell HP equipment. |
|
|