|
DL QuickSpecs
|
DL20
|
|
DL60
|
|
DL80
|
|
DL120
|
|
DL140
|
|
DL145
|
|
DL160
|
|
DL160se
|
|
DL165
|
|
DL180
|
|
DL185
|
|
DL320
|
|
DL325
|
|
DL345
|
|
DL360
|
|
DL365
|
|
DL380
|
|
DL385
|
|
DL388
|
|
DL560
|
|
DL580
|
|
DL585
|
|
DL740
|
|
DL760
|
|
DL785
|
|
DL1000
|
|
|
ML QuickSpecs
|
ML30
|
|
ML110
|
|
ML115
|
|
ML150
|
|
ML310
|
|
ML330
|
|
ML350
|
|
ML370
|
|
ML530
|
|
ML570
|
|
ML750
|
|
|
BL QuickSpecs
|
BL10e
|
|
BL20p
|
|
BL25p
|
|
BL260c
|
|
BL280c
|
|
BL2x220c
|
|
BL30p
|
|
BL35p
|
|
BL40p
|
|
BL420c
|
|
BL45p
|
|
BL460c
|
|
BL465c
|
|
BL480c
|
|
BL495c
|
|
BL60p
|
|
BL620c
|
|
BL660c
|
|
BL680c
|
|
BL685c
|
|
BL860c
|
|
|
SL QuickSpecs
|
SL160z
|
|
SL165z
|
|
SL170s
|
|
SL170z
|
|
SL230s
|
|
SL250s
|
|
SL270s
|
|
SL2x170z
|
|
SL335s
|
|
SL390s
|
|
SL4540
|
|
SL4545
|
|
|
XL QuickSpecs
|
XL170r
|
|
XL190r
|
|
XL220a
|
|
XL230a
|
|
XL730f
|
|
XL740f
|
|
XL750f
|
|
|
CL QuickSpecs
|
CL1850
|
CL1850 G1
| |
CL380
|
CL380 G1
| |
|
|
|
|
|
|
|
Proliant ML530 G2 QuickSpecs |
US QuickSpecs |
|
|
|
|
|
|
|
|
|
Proliant ML530 G2 Overview
HP ProLiant ML530 Generation 2 (G2)
|
1. 1.44MB Diskette Drive |
2. High Speed IDE CD-ROM |
3. Diagnostic Lighting |
4. Wide Ultra3/Ultra320 Hot Plug Drive Bays (12
x 1" Standard) |
|
5. Front Bezel |
6. 5.25-inch Removable Media
Bays |
7. Seven PCI-X slots |
8. Memory Board |
|
|
|
1. Rack Handles |
2. 1.44MB Diskette Drive |
3. High Speed IDE CD-ROM |
|
4. Diagnostic Lighting |
5. Wide Ultra3/Ultra320 Hot Plug
Drive Bays (12 x 1" Standard) |
6. 5.25-inch Removable Media
Bays |
|
|
What's New
- Intel® Xeon 3.0GHz Processors with 400MHz system
bus
|
At A Glance
- Designed for maximum application performance and
user workload, the ML530 Generation 2 (G2) offers customers the first
2P expansion server with Mirrored Memory
- Intel Xeon 3.0 GHz, 2.80 GHz or 2.40 GHz Processors with 400MHz system
bus
- 512-KB level 2 cache per processor
- Enterprise Class chipset: ServerWorks GC HE
- PC1600 ECC SDRAM memory expandable to 16 GB (Advanced ECC memory standard)
- 2:1 interleaved memory
- Seven 64-Bit/100 MHz PCI-X slots; 4 Hot Plug Slots
- Two Ultra3 SCSI Drive Cages standard support up to 12 1" hot
plug hard drives
- Internal mass storage capacity up to 4.20 TB (12 x 300 GB + 2 x 300
GB 1" hot plug drives) with optional ML5xx Internal Two Bay Hot
Plug SCSI Drive Cage (with fan)
- Advanced Memory Protection including Mirrored Memory and Online Spare
Memory
- 600-Watt Hot Plug Power Supply with optional 1+ 1 redundancy
- Hot Plug System Fans with optional redundancy
- Embedded NC3163 Fast Ethernet NIC PCI 10/100 WOL (Wake On LAN) and
PXE support
- Integrated Dual Channel Wide Ultra3 SCSI Adapter
- Protected by HP Services, including a three-year, Next Business Day
on-site, limited, Global warranty and extended Pre-Failure Warranty
that covers processors, memory and disk drives - Certain restrictions
and exclusions apply. Consult the HP Customer Support Center at 1-800-345-1518
for details.
|
Standard Features
Processor
One of the following depending on
Model: |
Intel Xeon 3.0 GHz/512
KB Processor (with 400 MHz system bus)
NOTE: 1P Models ship with one processor
standard. 2P Models ship with two processors standard. |
Intel Xeon 2.80
GHz/512 KB Processor (with 400 MHz system bus)
NOTE: 1P Models ship with one processor
standard. 2P Models ship with two processors standard. |
Intel Xeon 2.40
GHz/512 KB Processor (with 400 MHz system bus)
NOTE: 1P Models ship with one processor
standard. 2P Models ship with two processors standard. |
|
Cache Memory |
512-KB level 2 cache
per processor |
|
Upgradability |
Upgradable to dual
processing
NOTE: 1P Models only. |
|
Memory
| Standard | 1024
MB (2 x 512 MB) PC1600-MHz Registered ECC SDRAM | |
Maximum |
16 GB |
|
Network Controller |
Embedded NC3163 Fast Ethernet
NIC PCI 10/100 with full WOL (Wake On LAN) and PXE support |
|
Expansion Slots |
Bus Speed
|
Bus Number
|
Hot Plug
|
PCI Voltage
|
Notes
|
1
|
64-bit/100MHz PCI-X |
1
|
Yes
|
3.3V
|
-
|
2
|
64-bit/100MHz PCI-X |
1
|
Yes
|
3.3V
|
SA6402/6404 not recommended
|
3
|
64-bit/100MHz PCI-X |
5
|
Yes
|
3.3V
|
-
|
4
|
64-bit/100MHz PCI-X |
5
|
Yes
|
3.3V
|
-
|
5
|
64-bit/100MHz PCI-X |
9
|
No
|
3.3V
|
-
|
6
|
64-bit/100MHz PCI-X |
9
|
No
|
3.3V
|
-
|
7
|
64-bit/100MHz PCI-X |
13
|
No
|
3.3V
|
Preferred RILOE slot
|
NOTE: For more
information regarding PCI-X, please see the following URL: https://www.hp.com/servers/pci-x. |
NOTE:
All slots can accept universal keyed PCI
cards. |
|
Storage Controllers |
Integrated Dual
Channel Wide Ultra3 SCSI Adapter |
|
Storage |
Diskette Drive |
1.44 MB Diskette Drive |
|
Optical Drive |
40x
IDE CD-ROM Drive | | Hard
Drives | None | | Internal
Storage |
4.20 TB (with optional ML5xx
Internal Two Bay Hot Plug Wide SCSI Drive Cage (with fan) (12 x 300 GB 1"
+ 2 x 300 GB 1") |
| Half
Height Bays | 2 bays for optional
tape backup, DVD, or SCSI devices |
|
Graphics |
Integrated Rage XL Video Controller
with 8 MB SDRAM Video Memory |
|
Form Factor |
Tower or Rack (7U) |
|
ProLiant
Essentials Foundation Pack Software |
HP Systems Insight Manager |
HP's new HP Systems Insight
Manager (HP SIM) helps maximize system uptime and performance and
reduce system maintenance costs by providing proactive notification
of problems before those problems result in unplanned downtime or
reduced productivity. HP SIM are both easy to set up work with the
Insight Management Agents, integrated Light-Out and Remote Insight
Light-Outs Edition, and Version Control Agents to deliver robust fault,
configuration, and asset management as well as remote administration.
With HP SIM customers will also be able to take advantage of role-based
security; the ability to manage ProLiant, Integrity, and HP 9000 systems;
and plug-ins for storage, client, printer, and power management as
well as server rapid deployment, performance management, and workload
management. For more details on HP SIM visit https://www.hp.com/go/hpsim. |
|
Management Agents |
The Management Agents
form the foundation for HP's Intelligent Manageability strategy. They
provide direct, browser-based access to in-depth instrumentation built
into HP servers, workstations, desktops, and portables, and send alerts
to Insight Manager 7 and other enterprise management applications
in case of subsystem or environmental failures. For additional information
about the Management Agents and other management products from HP,
please visit the management Web site at https://www.hp.com/servers/manage. |
|
SmartStart |
SmartStart is a tool that
simplifies server setup, providing a rapid way to deploy reliable
and consistent server configurations. For more information, please
visit the SmartStart Web site at https://www.hp.com/servers/smartstart.
SmartStart version supported (minimum): SmartStart 6.40. |
|
Subscriber's Choice |
Subscriber's Choice Driver
and Support Alerts/Notifications is a web-based email subscription
service that provides automatic delivery of software and driver change
notifications for ProLiant products. Sign up at https://www.hp.com/go/subscriberschoice
and customize your profile to receive various new alerts as they become
available, on a weekly or monthly basis. |
|
ROMPaq, support software, and
configuration utilities |
The latest software, drivers,
and firmware fully optimized and tested for your ProLiant server and
options available in SmartStart or downloadable from Software and
Drivers download pages, linked from the SmartStart website at https://www.hp.com/servers/smartstart. |
|
Survey
Utility and diagnostics utilities |
The most advanced configuration
analysis, reporting and troubleshooting utilities used by HP and at
your fingertips, available in SmartStart. |
|
Optional
ProLiant Essentials Value Packs |
Optional software offerings
that selectively extend the functionality of an Adaptive Infrastructure
to address specific business problems and needs:
- Rapid Deployment Pack an automated solution for multi-server
deployment and provisioning, enabling companies to quickly and
easily adapt to changing business demands.
- Workload Management Pack provides easier management of
complex environments, improving overall server utilization and
enabling Windows 2000 customers for the first time to confidently
deploy multiple applications on a single multiprocessor ProLiant
Server.
- Performance Management Pack a performance management
solution that identifies and explains hardware performance bottlenecks
on ProLiant servers and attached options enabling users to better
utilize their valuable resources.
- Intelligent Networking Pack - detects and analyzes network bottlenecks
or broken network linkages and steers traffic to the optimum route
based on network conditions.
|
| NOTE:
Flexible and volume quantity license kits are available for ProLiant Essentials
Value Packs. Refer to https://www.hp.com/servers/proliantessentials
or the various ProLiant Essentials Value Pack product QuickSpecs for more information.
NOTE: For more information regarding ProLiant Essentials Software,
please see the following URL: https://www.hp.com/servers/proliantessentials. |
|
Industry Standard
Compliance |
ACPI 1.0b Compliant |
PCI 2. 2 Compliant |
PCI-X 1.0 Compliant |
WOL Support |
Microsoft® Logo certifications |
Novell certified |
|
Availability |
Advanced Memory Protection Technology delivers unsurpassed memory
protection and server availability:
|
ECC protection provides the ability to detect and correct single bit
memory errors while Advanced ECC extends this coverage to include protection
against multiple simultaneous errors on a DIMM. Advanced ECC detects
and corrects 4bit memory errors that occur within a single DRAM chip
on a DIMM. Advanced ECC algorithms work in combination with industry
standard ECC DIMMS.
|
|
Advanced Memory Protection
Configurations |
|
Offers a higher level of memory protection than Advanced ECC alone.
The system is configured with a spare bank of memory. If the number
of single-bit correctable errors on a bank exceeds the pre-defined error
threshold, the failing bank will fail over to the Online Spare bank
without intervention or server interruption. The failed memory can then
be replaced at the user's convenience during a scheduled maintenance
window.
|
- Single-Board Mirrored Memory
|
Single-board mirrored memory provides a higher level of availability
than Advanced ECC and Online Spare Memory because it protects against
multi-bit errors. Single-board Mirrored Memory uses a single memory
board that is configured with a mirrored/redundant set of memory. The
system writes to both sets of memory, but reads from one. If a memory
bank has a multi-bit error or full DIMM failure, the system simply reads
from the mirrored bank instead. This process occurs without intervention
or server interruption, and the failed DIMM can be replaced during a
regularly scheduled shutdown.
|
NOTE: All Advanced Memory Protection modes are configured in the
ROM-Based Setup Utility (RBSU) and viewable through Insight Manager 7
(CIM 7) and the Integrated Management Log (IML).
|
- PCI-X Hot Plug Technology (Four 64bit/100MHz PCI-X hot plug slots
available)
- One 600W Hot Plug Power Supply standard
- Two Hot Plug System Fans standard
|
|
Intelligent Manageability |
Insight Manager 7
HP Systems Insight Manager
Redundant ROM
Remote Flash ROM Utility
Remote Lights-Out Edition (optional)
Automatic Server Recovery-2 (ASR-2)
Integrated Management Log
Server Health Logging
Drive Parameter Tracking (with Smart Array Controller)
Dynamic Sector Repairing (with Smart Array Controller)
Pre-Failure Warranty (covers processors, hard drives and memory) |
|
Security |
Power-on password
Hot plug keyboard password
Diskette drive control
Diskette boot control
QuickLock, Network Server Mode
Parallel and serial interface control
Administrator's password
Disk configuration lock |
|
Server Power Cords |
One Lowline power cord ships
standard |
|
Power Supply |
One 600W Hot Plug Power Supply
standard |
- Optional 2nd Power Supply for 1+1 redundancy
|
NOTE: Redundant
Hot Plug Power Supplies standard on 2P servers.
NOTE: North American variants ship with IEC320-C13 to Nema 5-15P
detachable power cord. (Rack models only). |
|
System Fans |
Two Hot Plug System Fans standard |
|
- Optional Hot Plug Redundant Fan kit includes two more
|
|
NOTE: Hot Plug
Redundant Fans standard on 2P servers. |
|
Rack
Airflow Requirements |
Rack 10000 series Cabinets
The increasing power of new high-performance processor technology requires
increased cooling efficiency for rack-mounted servers. The 10000 Series
Racks provide enhanced airflow for maximum cooling, allowing these racks
to be fully loaded with servers using the latest processors.
CAUTION:
If a third-party rack is used,
observe the following additional requirements to ensure adequate airflow
and to prevent damage to the equipment:
- Front and rear doors: If your 42U
server rack includes closing front and rear doors, you must allow 830
square inches (5,350 sq cm) of hole evenly distributed from top to bottom
to permit adequate airflow (equivalent to the required 64 percent open
area for ventilation).
- Side: The clearance between the installed
rack component and the side panels of the rack must be a minimum of
2.75 inches (7 cm).
CAUTION: Always use blanking panels
to fill all remaining empty front panel U-spaces in the rack. This arrangement
ensures proper airflow. Using a rack without blanking panels results in
improper cooling that can lead to thermal damage.
|
|
NOTE: For additional information, refer to the Setup and Installation Guide
or the Documentation CD provided with the server, or to the server documentation
located in the Support section at the following URL: https://h18000.www1.hp.com/products/servers/ProLiantml530/index.html. |
|
Installation of HP servers into
Third Party Round Hole Racks |
If a Third Party rack is used,
an additional rack kit will need to be used with the rack kit that comes
with the server. The additional rack kit part number is Compaq part number
274739-B21. The rack kit comers with all necessary brackets, hardware and
installation instructions.
NOTE: Third party square-holed racks
are supported using the standard rack rail kit that ships with the rack
server models. |
|
Installation of HP servers into
Telco Racks |
If
a Telco is used, an additional rack kit and brackets will need to be used with
the rack kit that comes with the server (optional Third Party Rack Kit (PN: 274739-B21)).
Please see the following URL to purchase the brackets (rack kit and brackets come
with all necessary brackets, hardware, and installation instructions: https://www.racksolutions.com/compaq/products.htm. |
|
HP Factory Express Capabilities |
HP Factory Express gives you
the flexibility to choose from a full menu of factory capabilities all in
one manufacturing facility, in one process, with one touch giving you full
control and access to HP's World class manufacturing facility anytime. This
approach provides you the speed to deploy your IT needs, with total quality
assurance, reliability, and predictability to lower your total cost of ownership
by letting HP install, rack, and customize your software and hardware options
for you. |
|
Service
and Support |
Three-year limited warranty,
including hardware diagnostic support, pre-failure warranty (coverage of
hard drives, memory and processors). The warranty is fully supported by
HP Services and a worldwide network of resellers and service providers.
In addition 90-day's getting started software telephone support may be covered
under the warranty or available for an additional fee. Enhancements to warranty
services are available through HP Care Pack services.
NOTE: Limited warranty includes 3 year
parts, 3 year labor, 3-year on-site support
Care Pack services provide a range of life cycle support options that
let you choose the service levels that meet your business requirements,
from basic to mission-critical.
A full range of HP Care Pack hardware and software services are available
including:
- Installation and start up
- Education courses
- Extended onsite hardware coverage hours from same business day 13
hours, 5 day to 24 hours, 7 days call window with options including
4-hour response or 6-hour Call To Repair
- Comprehensive range of software technical support for Microsoft, Linux,
ProLiant Essentials and VMWare-based IT solutions helping to deliver
high level of application availability. Response times range from 30
mins for critical problems to 2 hours.
- System Management, Performance Services and Mission Critical Support
Solution
HP Care Pack Services include HP branded hardware options qualified for
the server, purchased at the same time or afterwards, internal to the
enclosure, as well as 22" and smaller external monitors and tower
UPS options up to 3KVA. 22" and smaller external monitors will be
covered at the same service level and coverage period as the server. For
servers or storage systems installed within a rack, service also covers
all HP qualified rack options installed within the same rack.
|
|
NOTE: For more information on HP Care
Pack services, contact any of our worldwide sales offices or resellers
or visit our worldwide Web site on the internet at: https://www.hp.com/hps/carepack
NOTE: For more complete information
on HP Services offerings, customers and resellers, please visit us at:
https://www.hp.com/hps
NOTE: Additional information regarding
worldwide limited warranty and technical support is available at: https://h18004.www1.hp.com/products/servers/platforms/warranty/index.html
|
Models
ML530T02 X3.0-512KB,
1024MB, 1P
271243-xx1
|
Processor |
One Intel Xeon 3.0 GHz Processor
standard (up to 2 supported) |
Processor System Bus |
400 MHz system bus |
Processor Memory |
512-KB level 2 cache per processor |
Memory |
1024 MB (Standard) 16,384 MB
(Maximum) PC1600 Advanced ECC SDRAM; 2:1 interleaved memory
NOTE: Maximum memory achieved using
2048 MB DIMMs. |
Network Controller |
Embedded NC3163 Fast Ethernet
NIC PCI 10/100 with WOL (Wake On LAN) |
Storage Controller |
Integrated Dual Channel Wide
Ultra3 SCSI Adapter |
Hard Drive |
None ship standard |
Internal Storage |
12 1" hot plug hard drive
bays standard |
Power Supplies |
One 600W Hot Plug Power Supply |
System Fan |
Hot Plug System Fans |
Drive Cages |
Two 6 x 1" Drive Cages
standard |
Optical Drive |
40x or higher IDE CD-ROM Drive |
Diskette Drive |
1.44 MB Diskette Drive |
Form Factor |
Tower |
|
ML530T02 X3.0-512KB,
1024MB, 2P
271245-xx1
|
Processor |
Two Intel Xeon 3.0 GHz Processor
standard |
Processor System Bus |
400 MHz system bus |
Processor Memory |
512-KB level 2 cache per processor |
Memory |
1024 MB (Standard) 16,384 MB
(Maximum) PC1600 Advanced ECC SDRAM; 2:1 interleaved memory
NOTE: Maximum memory achieved using
2048 MB DIMMs. |
Network Controller |
Embedded NC3163 Fast Ethernet
NIC PCI 10/100 with WOL (Wake On LAN) |
Storage Controller |
Integrated Dual Channel Wide
Ultra3 SCSI Adapter |
Hard Drive |
None ship standard |
Internal Storage |
12 1" hot plug hard drive
bays standard |
Power Supplies |
Redundant 600W Hot Plug Power
Supplies (1+ 1 redundancy) |
System Fan |
Redundant Hot Plug System Fans |
Drive Cages |
Two 6 x 1" Drive Cages
standard |
Optical Drive |
40x or higher IDE CD-ROM Drive |
Diskette Drive |
1.44 MB Diskette Drive |
Form Factor |
Tower |
|
ML530T02 X2.80-512KB,
1024MB, 1P
306487-xx1
|
Processor |
One Intel Xeon 2.80 GHz Processor
standard (up to 2 supported) |
Processor System Bus |
400 MHz system bus |
Processor Memory |
512-KB level 2 cache per processor |
Memory |
1024 MB (Standard) 16,384 MB
(Maximum) PC1600 Advanced ECC SDRAM; 2:1 interleaved memory
NOTE: Maximum memory achieved using
2048 MB DIMMs. |
Network Controller |
Embedded NC3163 Fast Ethernet
NIC PCI 10/100 with WOL (Wake On LAN) |
Storage Controller |
Integrated Dual Channel Wide
Ultra3 SCSI Adapter |
Hard Drive |
None ship standard |
Internal Storage |
12 1" hot plug hard drive
bays standard |
Power Supplies |
One 600W Hot Plug Power Supply |
System Fan |
Hot Plug System Fans |
Drive Cages |
Two 6 x 1" Drive Cages
standard |
Optical Drive |
40x or higher IDE CD-ROM Drive |
Diskette Drive |
1.44 MB Diskette Drive |
Form Factor |
Tower |
|
ML530T02 X2.80-512KB,
1024MB, 2P
306489-xx1
|
Processor |
Two Intel Xeon 2.80 GHz Processor
standard |
Processor System Bus |
400 MHz system bus |
Processor Memory |
512-KB level 2 cache per processor |
Memory |
1024 MB (Standard) 16,384 MB
(Maximum) PC1600 Advanced ECC SDRAM; 2:1 interleaved memory
NOTE: Maximum memory achieved using
2048 MB DIMMs. |
Network Controller |
Embedded NC3163 Fast Ethernet
NIC PCI 10/100 with WOL (Wake On LAN) |
Storage Controller |
Integrated Dual Channel Wide
Ultra3 SCSI Adapter |
Hard Drive |
None ship standard |
Internal Storage |
12 1" hot plug hard drive
bays standard |
Power Supplies |
Redundant 600W Hot Plug Power
Supplies (1+ 1 redundancy) |
System Fan |
Redundant Hot Plug System Fans |
Drive Cages |
Two 6 x 1" Drive Cages
standard |
Optical Drive |
40x or higher IDE CD-ROM Drive |
Diskette Drive |
1.44 MB Diskette Drive |
Form Factor |
Tower |
|
ML530T02 X2.40-512KB,
1024MB, 1P
180285-xx1
|
Processor |
One Intel Xeon 2.40 GHz Processor
standard (up to 2 supported) |
Processor System Bus |
400 MHz system bus |
Processor Memory |
512-KB level 2 cache per processor |
Memory |
1024 MB (Standard) 16,384 MB
(Maximum) PC1600 Advanced ECC SDRAM; 2:1 interleaved memory
NOTE: Maximum memory achieved using
2048 MB DIMMs. |
Network Controller |
Embedded NC3163 Fast Ethernet
NIC PCI 10/100 with WOL (Wake On LAN) |
Storage Controller |
Integrated Dual Channel Wide
Ultra3 SCSI Adapter |
Hard Drive |
None ship standard |
Internal Storage |
12 1" hot plug hard drive
bays standard |
Power Supplies |
One 600W Hot Plug Power Supply |
System Fan |
Hot Plug System Fans |
Drive Cages |
Two 6 x 1" Drive Cages
standard |
Optical Drive |
40x or higher IDE CD-ROM Drive |
Diskette Drive |
1.44 MB Diskette Drive |
Form Factor |
Tower |
|
ML530T02 X2.40-512KB,
1024MB, 2P
226608-xx1 |
Processor |
Two Intel Xeon 2.40 GHz Processors
standard |
Processor System Bus |
400 MHz system bus |
Processor Memory |
512-KB level 2 cache per processor |
Memory |
1024 MB (Standard) 16,384 MB
(Maximum) PC1600 Advanced ECC SDRAM; 2:1 interleaved memory
NOTE: Maximum memory achieved using
2048 MB DIMMs. |
Network Controller |
Embedded NC3163 Fast Ethernet
NIC PCI 10/100 with WOL (Wake On LAN) |
Storage Controller |
Integrated Dual Channel Wide
Ultra3 SCSI Adapter |
Hard Drive |
None ship standard |
Internal Storage |
12 1" hot plug hard drive
bays standard |
Power Supplies |
Redundant 600W Hot Plug Power
Supplies (1+ 1 redundancy) |
System Fan |
Redundant Hot Plug System Fans |
Drive Cages |
Two 6 x 1" Drive Cages
standard |
Optical Drive |
40x or higher IDE CD-ROM Drive |
Diskette Drive |
1.44 MB Diskette Drive |
Form Factor |
Tower |
|
ML530R02 X3.0-512KB,
1024MB, 1P
271244-xx1 |
Processor |
One Intel Xeon 3.0 GHz Processor
standard (up to 2 supported) |
Processor System Bus |
400 MHz system bus |
Processor Memory |
512-KB level 2 cache per processor |
Memory |
1024 MB (Standard) 16,384 MB
(Maximum) PC1600 Advanced ECC SDRAM; 2:1 interleaved memory
NOTE: Maximum memory achieved using
2048 MB DIMMs. |
Network Controller |
Embedded NC3163 Fast Ethernet
NIC PCI 10/100 with WOL (Wake On LAN) |
Storage Controller |
Integrated Dual Channel Wide
Ultra3 SCSI Adapter |
Hard Drive |
None ship standard |
Internal Storage |
12 1" hot plug hard drive
bays standard |
Power Supplies |
One 600W Hot Plug Power Supply |
System Fan |
Hot Plug System Fans |
Drive Cages |
Two 6 x 1" Drive Cages
standard |
Optical Drive |
40x or higher IDE CD-ROM Drive |
Diskette Drive |
1.44 MB Diskette Drive |
Form Factor |
Rack (7U) |
|
ML530R02 X3.0-512KB,
1024MB, 2P
271246-xx1 |
Processor |
Two Intel Xeon 3.0 GHz Processor
standard |
Processor System Bus |
400 MHz system bus |
Processor Memory |
512-KB level 2 cache per processor |
Memory |
1024 MB (Standard) 16,384 MB
(Maximum) PC1600 Advanced ECC SDRAM; 2:1 interleaved memory
NOTE: Maximum memory achieved using
2048 MB DIMMs. |
Network Controller |
Embedded NC3163 Fast Ethernet
NIC PCI 10/100 with WOL (Wake On LAN) |
Storage Controller |
Integrated Dual Channel Wide
Ultra3 SCSI Adapter |
Hard Drive |
None ship standard |
Internal Storage |
12 1" hot plug hard drive
bays standard |
Power Supplies |
Redundant 600W Hot Plug Power
Supplies (1+ 1 redundancy) |
System Fan |
Redundant Hot Plug System Fans |
Drive Cages |
Two 6 x 1" Drive Cages
standard |
Optical Drive |
40x or higher IDE CD-ROM Drive |
Diskette Drive |
1.44 MB Diskette Drive |
Form Factor |
Rack (7U) |
|
ML530R02 X2.80-512KB,
1024MB, 1P
306488-xx1 |
Processor |
One Intel Xeon 2.80 GHz Processor
standard (up to 2 supported) |
Processor System Bus |
400 MHz system bus |
Processor Memory |
512-KB level 2 cache per processor |
Memory |
1024 MB (Standard) 16,384 MB
(Maximum) PC1600 Advanced ECC SDRAM; 2:1 interleaved memory
NOTE: Maximum memory achieved using
2048 MB DIMMs. |
Network Controller |
Embedded NC3163 Fast Ethernet
NIC PCI 10/100 with WOL (Wake On LAN) |
Storage Controller |
Integrated Dual Channel Wide
Ultra3 SCSI Adapter |
Hard Drive |
None ship standard |
Internal Storage |
12 1" hot plug hard drive
bays standard |
Power Supplies |
One 600W Hot Plug Power Supply |
System Fan |
Hot Plug System Fans |
Drive Cages |
Two 6 x 1" Drive Cages
standard |
Optical Drive |
40x or higher IDE CD-ROM Drive |
Diskette Drive |
1.44 MB Diskette Drive |
Form Factor |
Rack (7U) |
|
ML530R02 X2.80-512KB,
1024MB, 2P
306490-xx1 |
Processor |
Two Intel Xeon 2.80 GHz Processor
standard |
Processor System Bus |
400 MHz system bus |
Processor Memory |
512-KB level 2 cache per processor |
Memory |
1024 MB (Standard) 16,384 MB
(Maximum) PC1600 Advanced ECC SDRAM; 2:1 interleaved memory
NOTE: Maximum memory achieved using
2048 MB DIMMs. |
Network Controller |
Embedded NC3163 Fast Ethernet
NIC PCI 10/100 with WOL (Wake On LAN) |
Storage Controller |
Integrated Dual Channel Wide
Ultra3 SCSI Adapter |
Hard Drive |
None ship standard |
Internal Storage |
12 1" hot plug hard drive
bays standard |
Power Supplies |
Redundant 600W Hot Plug Power
Supplies (1+ 1 redundancy) |
System Fan |
Redundant Hot Plug System Fans |
Drive Cages |
Two 6 x 1" Drive Cages
standard |
Optical Drive |
40x or higher IDE CD-ROM Drive |
Diskette Drive |
1.44 MB Diskette Drive |
Form Factor |
Rack (7U) |
|
ML530R02 X2.40-512KB,
1024MB, 1P
180286-xx1 |
Processor |
One Intel Xeon 2.40 GHz Processor
standard (up to 2 supported) |
Processor System Bus |
400 MHz system bus |
Processor Memory |
512-KB level 2 cache per processor |
Memory |
1024 MB (Standard) 16,384 MB
(Maximum) PC1600 Advanced ECC SDRAM; 2:1 interleaved memory
NOTE: Maximum memory achieved using
2048 MB DIMMs. |
Network Controller |
Embedded NC3163 Fast Ethernet
NIC PCI 10/100 with WOL (Wake On LAN) |
Storage Controller |
Integrated Dual Channel Wide
Ultra3 SCSI Adapter |
Hard Drive |
None ship standard |
Internal Storage |
12 1" hot plug hard drive
bays standard |
Power Supplies |
One 600W Hot Plug Power Supply |
System Fan |
Hot Plug System Fans |
Drive Cages |
Two 6 x 1" Drive Cages
standard |
Optical Drive |
40x or higher IDE CD-ROM Drive |
Diskette Drive |
1.44 MB Diskette Drive |
Form Factor |
Rack (7U) |
|
ML530R02 X2.40-512KB,
1024MB 2P
226609-xx1 |
Processor |
Two Intel Xeon 2.40 GHz Processors
standard |
Processor System Bus |
400 MHz system bus |
Processor Memory |
512-KB level 2 cache per processor |
Memory |
1024 MB (Standard) 16,384 MB
(Maximum) PC1600 Advanced ECC SDRAM; 2:1 interleaved memory
NOTE: Maximum memory achieved using
2048 MB DIMMs. |
Network Controller |
Embedded NC3163 Fast Ethernet
NIC PCI 10/100 with WOL (Wake On LAN) |
Storage Controller |
Integrated Dual Channel Wide
Ultra3 SCSI Adapter |
Hard Drive |
None ship standard |
Internal Storage |
12 1" hot plug hard drive
bays standard |
Power Supplies |
Redundant 600W Hot Plug Power
Supplies (1+ 1 redundancy) |
System Fan |
Redundant Hot Plug System Fans |
Drive Cages |
Two 6 x 1" Drive Cages
standard |
Optical Drive |
40x or higher IDE CD-ROM Drive |
Diskette Drive |
1.44 MB Diskette Drive |
Form Factor |
Rack (7U) |
|
Country Code Key |
|
Tower Code Key |
Rack Code Key |
|
XX=00 |
U.S. English |
U.S. English |
|
XX=01 |
Australia |
N/A |
|
XX=03 |
UK |
N/A |
|
XX=04 |
Germany |
N/A |
|
XX=05 |
France |
N/A |
|
XX=37 |
APD |
APD |
|
XX=29 |
Japan |
Japan |
|
XX=42 |
Europe |
Europe |
|
XX=AA |
PRC |
PRC |
|
|
|
|
Options
ProLiant
ML530 G2 Unique Options |
Intel Xeon 3.0 GHz/512
KB Processor Option Kit |
|
Intel Xeon 2.80 GHz/512
KB Processor Option Kit |
|
Intel Xeon 2.40 GHz/512
KB Processor Option Kit |
|
|
ProLiant
Essentials
Value Pack Software |
Rapid Deployment
Pack, 1 User, V1.x
NOTE:
This license allows 1 server to be managed and deployed via the Deployment
Server. |
267196-B21
|
Rapid Deployment
Pack, 1 User, V1.x (Japan)
NOTE: This license allows 1 server
to be managed and deployed via the Deployment Server. |
267196-291
|
Rapid Deployment
Pack, 10 Users, V1.x
NOTE:
This license allows 10 servers to be managed and deployed via the Deployment
Server. |
269817-B21
|
Rapid Deployment
Pack, 10 Users, V1.x (Japan)
NOTE:
This license allows 10 servers to be managed and deployed via the Deployment
Server. |
269817-291
|
ProLiant Essentials
Workload Management Pack 2.0 (Featuring Compaq Resource Partitioning Manager
version 2.0) |
|
Performance Management
Pack, single server
NOTE: This license allows 1 server
to be managed by Performance Management Pack.
|
306696-B21
|
ProLiant Essentials
Performance Management Pack, 10 Pack Server License |
374055-B21
|
Performance Management
Pack, flexible license kit
NOTE: A single pack is shipped with
a single license key for the total number of licenses ordered
|
306697-B21
|
ProLiant Essentials
Intelligent Networking Pack, 1 License |
372906-B21
|
ProLiant Essentials
Intelligent Networking Pack Flex License |
372950-B21
|
ProLiant Essentials
Intelligent Networking Pack Track License |
372951-B21
|
ProLiant Essentials
Virtual Machine Management Pack, Single-Server License
NOTE: For use with a single server.
Contains one license with a unique license activation key and documentation.
|
372214-B21
|
ProLiant Essentials
Virtual Machine Management Pack, Flexible-Quantity License
NOTE: For use with multiple servers.
This part number can be used to purchase multiple licenses with a single
activation key.
|
372215-B21
|
ProLiant Essentials
Virtual Machine Management Pack, Tracking License
NOTE: For use with signed and implemented
Activation Key Agreements only. Purchase of this part number entitles the
customer to deploy additional licenses of the product under the terms of
the existing Activation Key Agreement.
|
372216-B21
|
ProLiant Essentials
Vulnerability and Patch Management Pack, Single-Server License |
371645-B21
|
ProLiant Essentials
Vulnerability and Patch Management Pack, 10-Server License |
377529-B21
|
ProLiant Essentials
Vulnerability and Patch Management Pack, Flexible-Quantity License |
371646-B21
|
ProLiant Essentials
Vulnerability and Patch Management Pack, Tracking license for new servers |
371647-B21
|
ProLiant Essentials
Vulnerability and Patch Management Pack, Tracking license for installed
servers |
378372-B21
|
NOTE:
Flexible and volume quantity license kits are available for ProLiant
Essentials Value Packs. Refer to https://www.hp.com/servers/proliantessentials
or the various ProLiant Essentials Value Pack product QuickSpecs for
more information.
NOTE: For more information regarding ProLiant Essentials Software,
please see the following URL: https://www.hp.com/servers/proliantessentials. |
|
|
Software |
HP digital asset protection |
302316-001 |
|
Processor |
Intel Xeon 3.0 GHz/512
KB Processor Option Kit |
|
Intel Xeon 2.80 GHz/512
KB Processor Option Kit |
|
Intel Xeon 2.40 GHz/512
KB Processor Option Kit |
|
|
ML530 G2 Memory
(DIMMs; 2:1 interleaved)
|
512MB PC1600 Registered ECC SDRAM
Memory Kit (2 x 256 MB) |
|
1024MB PC1600 Registered ECC SDRAM
Memory Kit (2 x 512 MB) |
|
2048MB PC1600 Registered ECC SDRAM
Memory Kit (2 x 1024 MB) |
|
4096MB PC1600 Registered ECC SDRAM
Memory Kit (2 x 2048 MB) |
|
|
Optical Drives |
16X DVD-ROM Drive Option Kit (Carbon)
NOTE: This drive is supported in
the CD-ROM bay and in the removable media bay.
|
217053-B21 |
|
CD-RW/DVD ROM Combo Drive Option
Kit
NOTE: This drive is supported in
the CDROM bay and in the removable media bay. |
|
|
Internal Storage
|
ML5xx Two Bay Hot Plug SCSI Drive
Cage
NOTE: The drive cage option kit (PN
244058-B21) has one 1" drive bay and one 1.6" drive bay. |
244058-B21
|
|
ML530 G2 Hard Drives |
Ultra320 SCSI Universal
Hot Plug |
|
300-GB 10,000 rpm U320 Universal
Hard Drive (1")
|
|
146.8-GB 10,000 rpm U320 Universal
Hard Drive (1")
|
|
72.8-GB 10,000 rpm U320 Universal
Hard Drive (1") |
|
72.8-GB 15,000 rpm U320 Universal
Hard Drive (1") |
|
36.4-GB 15,000 rpm U320 Universal
Hard Drive (1") |
|
NOTE: All U320
Universal Hard Drives are backward compatible to U2 or U3 speeds. U320 drives
require an optional U320 Smart Array Controller or U320 SCSI HBA to support
U320 transfer rates. |
|
NOTE: Please see
the Hard Drive QuickSpecs for Technical Specifications such as capacity,
height, width, interface, transfer rate, seek time, physical configuration,
and operating temperature: U320 Hard Drive QS:
https://h18000.www1.hp.com/products/quickspecs/11531_div/11531_div.html
(Worldwide)
https://h18000.www1.hp.com/products/quickspecs/11531_na/11531_na.html
(North America) |
|
|
Storage Controllers |
256MB DDR, Battery-Backed Cache
Upgrade Kit for SA-6400
NOTE: This 256-MB Battery-Backed
Cache upgrade kit supports the Smart Array 6400 series controller only. |
|
Smart Array 6402/128 Controller |
|
Smart Array 6404/256 Controller |
|
Smart Array 641 Controller
|
|
Smart Array 642 Controller
|
|
128-MB Cache Module for Smart
Array 5302 Controller |
|
256-MB Battery-Back Cache Module
NOTE: This 256-MB Battery-Backed
Cache Module supports the Smart Array 5300 series controllers, HP StorageWorks
Modular Smart Array 1000 and the HP StorageWorks Modular Smart Array 500. |
|
128MB Battery-Backed Cache Enabler
NOTE: This 128MB BBWC supports the
Smart Array 641 Controller and Smart Array 642 Controller. |
|
64-Bit/133MHz Dual Channel Ultra320 SCSI Adapter
|
|
Ultra320 Expansion Module for
SA-6402 |
|
64-Bit/66-MHz Dual Channel Wide
Ultra3 SCSI Adapter, Alternate OS |
|
NOTE: Please see
the following Controller or SCSI Adapter QuickSpecs for Technical Specifications
such as PCI Bus, PCI Peak Data Transfer Rate, SCSI Protocols supported,
SCSI Peak Data Transfer Rate, Channels, SCSI Ports, Drives supported, Cache,
RAID support, and additional information:
https://h18000.www1.hp.com/products/quickspecs/11587_div/11587_div.html
(Smart Array 6400 Series)
https://h18000.www1.hp.com/products/quickspecs/12067_div/12067_div.html
(Smart Array 641)
https://h18000.www1.hp.com/products/quickspecs/12069_div/12069_div.html
(Smart Array 642)
https://h18000.www1.hp.com/products/quickspecs/10429_div/10429_div.html
(SCSI Adapter)
https://h18000.www1.hp.com/products/quickspecs/11555_div/11555_div.html
(U320 Adapter) |
|
|
Communications |
NC6170 Dual Port PCI-X 1000SX
Gigabit Server Adapter |
|
|
HP NC6770 PCI-X Gigabit Server
Adapter, 1000-SX |
|
|
NC7170 Dual Port PCI-X 1000T Gigabit
Server Adapter |
|
|
NC7771 PCI-X Gigabit Server Adapter
|
|
|
NOTE: Any NC61XX,
NC71XX or NC77XX NIC can be used for redundancy with the embedded NC7781
Network Controller. |
|
|
Redundant Options
|
Hot-plug Redundant Fan Kit
NOTE: Included in 2P models. |
|
Hot Plug Redundant Power Supply
NOTE:
Included in 2P models. |
|
Hot
Plug Redundant Power Supply (Australia)
NOTE: Included in 2P models. |
236845-011
|
Hot Plug Redundant Power Supply
(Int'l)
NOTE: Included in 2P models. |
236845-021
|
Hot Plug Redundant Power Supply
(UK)
NOTE: Included in 2P models. |
236845-031
|
Hot Plug Redundant Power Supply
(Japan)
NOTE:
Included in 2P models. |
236845-291
|
|
Management Options
|
Remote Insight Lights-Out Edition II (NA, LA)
|
227251-001
|
Remote Insight Lights-Out Edition II (EMEA)
|
227251-021
|
Remote Insight Lights-Out Edition II (ROW)
|
227251-371
|
|
Security |
HP/Atalla AXL600L SSL Accelerator
Card for ProLiant Servers |
|
AXL300 Accelerator PCI Card for
ProLiant Servers |
227933-B21
|
|
Tape Drives
|
NOTE: In
order to install certain tape drives internally, you may need to remove
the rails that come standard on the drives and then re-insert the
screws in the mounting holes. Mounting screws are shipped standard
with server. |
|
NOTE: External
tape devices, including both tape drives and tape arrays/enclosures,
can be directly connected to the VHDCI SCSI port located on the back
of the server. Use of a SCSI adapter to connect these devices is optional,
not required. |
|
Internal, External,
and Rack-Mount Ultrium Tape Drives |
|
HP StorageWorks Ultrium
215 Tape Drive, External (Carbon) |
|
HP StorageWorks Ultrium
215 rack-mount (Carbon) - Single drive installed in a 3U rack-mount
kit |
|
HP StorageWorks Ultrium
215 Array Module (Carbon) - Offline hot-swap drive for Tape Array
5300 |
|
HP StorageWorks Ultrium
230 Tape Drive, Internal (Carbon)
NOTE: When purchasing this
internal drive a cooling fan also needs to be ordered. The fan kit
part number is 344257-B21 and comes with installation instructions
to install inside the server. |
|
HP StorageWorks Ultrium
230 Tape Drive, External (Carbon) |
|
HP StorageWorks Ultrium
230, Rack-mount (Carbon) - Single drive installed in a 3U rack-mount
kit |
|
HP StorageWorks Ultrium
230 Array Module (Carbon) - Offline hot-swap drive for Tape Array
5300 |
|
HP StorageWorks Ultrium
460 Tape Drive, Internal (Carbon) |
|
HP StorageWorks Ultrium
460 Tape Drive, External (Carbon) |
|
HP StorageWorks Ultrium
460, Rack-mount (Carbon) - Single drive installed in a 3U rack-mount
kit |
|
HP StorageWorks Ultrium
460 Array Module (Carbon) - Offline hot-swap drive for Tape Array
5300 |
|
Fan Option - Internal Cooling
Fan Kit |
344257-B21
|
HP StorageWorks Ultrium
960 Tape Drive, Internal (Carbonite) |
|
HP StorageWorks Ultrium
960 Tape Drive, External (Carbonite) |
|
HP StorageWorks Ultrium
960 Rack-mount (Carbonite) - Single drive installed in a 3U rack-mount
kit |
|
NOTE:
Needs to be ordered when purchasing an internal Ultrium 230 drive
that will be installed inside of an ML 530 G1/G2 or ML 570 G1/G2.
Kit includes fan and instructions to install fan inside of server
in drive bay.
|
|
NOTE: Please
see the HP StorageWorks Ultrium 215, 230, and 460 Tape Drive QuickSpecs
for additional options such as controllers, media, and other related
items:
https://h18006.www1.hp.com/products/quickspecs/11739_div/11739_div.html
(Worldwide)
https://h18006.www1.hp.com/products/quickspecs/11739_na/11739_na.html
(North America) |
|
For
an up-to-date listing of the latest O/S and software support details
for HP Ultrium tape drives, please visit: https://www.hp.com/go/connect |
|
Internal, External,
Hot-Plug, and Rack-Mount DAT Drives
|
|
HP StorageWorks DAT 72 Tape
Drive, External (Carbon) |
|
HP StorageWorks DAT 72 Tape
Drive, Internal (Carbon) |
|
HP StorageWorks DAT 72 Tape
Drive, Internal Hot-Plug (Carbon) |
|
HP StorageWorks DAT 72 Array
Module (Carbon) - Offline hot-swap drive for Tape Array 5300 |
|
HP StorageWorks DAT 40 Tape
Drive, External (Carbon) |
|
HP StorageWorks DAT 40 Tape
Drive, Internal (Carbon) |
|
HP StorageWorks DAT 40 Tape
Drive, Internal Hot-Plug (Carbon) |
|
HP StorageWorks DAT 40 Array
Module (Carbon) - Offline hot-swap drive for Tape Array 5300 |
|
HP StorageWorks DAT 24 Tape
Drive, External (Flint) |
|
HP StorageWorks DAT 24 Tape
Drive, Internal (Flint) |
|
HP StorageWorks DAT 24 Array
Module (Carbon) - Offline hot-swap drive for Tape Array 5300 |
|
NOTE:
Please see the DAT Tape Drive QuickSpecs for controllers, media,
and other options:
https://h18000.www1.hp.com/products/quickspecs/11883_div/11883_div.html
(Worldwide)
For an up-to-date listing of the latest O/S and software support details
for HP DAT drives, please visit: https://www.hp.com/go/connect
|
|
Internal and External
DLT VS Tape Drives
|
|
HP StorageWorks DLT VS80
Tape Drive, Internal (Carbon) WW |
|
HP StorageWorks DLT VS80
Tape Drive, External (Carbon) NA |
|
HP StorageWorks DLT VS80
Tape Drive, External (Carbon) Int'l |
337699-B31
|
HP StorageWorks DLT VS80
Tape Drive, External (Carbon) Japan
|
337699-291
|
NOTE: Please
see the DLT VS80 Tape Drive QuickSpecs for additional options such
as host bus adapters, controllers, media, and other oprions:
https://h18006.www1.hp.com/products/quickspecs/11403_div/11403_div.html
(Worldwide)
https://h18006.www1.hp.com/products/quickspecs/11403_na/11403_na.html
(North America)
For an up-to-date listing of the latest O/S and software support details
for the DLT VS80, please visit: https://www.hp.com/go/connect
|
|
Internal, External
and Rack-mount SDLT Tape Drives |
|
HP StorageWorks SDLT 320
Tape Drive, Internal (Carbon) WW
NOTE: When purchasing this
internal drive a cooling fan also needs to be ordered. The fan kit
part number is 344257-B21 and comes with installation instructions
to install inside the server.
|
|
HP StorageWorks SDLT 320
Tape Drive, External (Carbon) NA |
|
HP StorageWorks SDLT 320
Tape Drive, External (Carbon) Int'l |
257319-B31
|
HP StorageWorks SDLT 320
Tape Drive, External (Carbon) Japan |
257319-291
|
Fan Option - Internal Cooling
Fan Kit
|
344257-B21
|
NOTE:
Needs to be ordered when purchasing an internal SDLT 320 drive that
will be installed inside of an ML530 G1/G2 or ML570 G1/G2. Kit includes
fan and instructions to install fan inside of server in drive bay.
|
|
NOTE:
Please see the SDLT 320 Tape Drive QuickSpecs for additional options
such as adapters, controllers, and media.
https://h18006.www1.hp.com/products/quickspecs/11840_div/11840_div.html
(Worldwide)
https://h18006.www1.hp.com/products/quickspecs/11840_na/11840_na.html
(North America)
For an up-to-date listing of the latest O/S and software support details
for HP SDLT tape drives, please visit: https://www.hp.com/go/connect
|
|
Rack-Mount Tape Drive
Enclosures
|
|
HP StorageWorks 1U Rack-Mount
Kit
NOTE: The 1U Rack-mount Kit
can support up to 2 half-height tape drives and compatible with multiple
Single-Ended and LVD SCSI tape drives including DAT 24, DAT40, DAT72,
DLT VS 80, and Ultrium 215 tape drives.
|
|
HP StorageWorks 3U Rack-Mount
Kit
NOTE: The 3U Rack-Mount Kit
can support up to 2 full-height or 4 half-height tape drives and compatible
with multiple Single-Ended and LVD SCSI tape drives including DAT,
DLT VS80, SDLT 320, Ultrium 215, Ultrium 230, and Ultrium 460 Tape
Drives.
|
|
HP StorageWorks 5U Rack-Mount
Kit
NOTE: The 5U Rack-Mount Kit
can support up to 4 full-height tape drives and is compatible with
SDLT 320, Ultrium 230, and Ultrium 460 tape drives.
|
274339-B21
|
NOTE: Please
see the Rack-Mount Tape Drive Kits QuickSpecs for additional information
regarding these kits:
https://h18000.www1.hp.com/products/quickspecs/10854_div/10854_div.html
(Worldwide)
https://h18000.www1.hp.com/products/quickspecs/10854_na/10854_na.html
(North America) |
|
HP StorageWorks Tape Array
5300 |
|
NOTE:
The Tape Array 5300 is a 3U enclosure that supports up to 2 full-height
or 4 half-height hot-swap array modules, including DAT and Ultrium
tape drives. Cables and terminators are not included and must be ordered
separately.
NOTE: Please see the Tape Array 5300 QuickSpecs for additional
information regarding this product.
https://h18000.www1.hp.com/products/quickspecs/11878_div/11878_div.html
(Worldwide)
https://h18000.www1.hp.com/products/quickspecs/11878_na/11878_na.html
(North America)
|
|
Accessories for 3U
& 5U Rack-mount Tape Drive Kits
|
|
LVD Cable Kit, VHDCI/HD68
NOTE: For use with the 3U Rack-mount
Kit and 5U Rack-mount Kit only. |
|
LVD Cable Kit, HD68/HD68
NOTE: For use with the 3U Rack-mount
Kit and 5U Rack-mount Kit only.
|
|
Accessories for 3U
& 5U Rack-mount Tape Drive Kits
|
|
PSU/Fan
Upgrade Kit - Redundant hot-swap power supply unit and fan for Tape
Array 5300.
|
|
68-pin HD multi-mode terminator |
|
1.0m 68-pin VHDCI to 68-pin
HD cable |
|
2.5m 68-pin VHDCI to 68-pin
HD cable |
|
5.0m 68-pin VHDCI to 68-pin
HD cable |
|
10.0m 68-pin VHDCI to 68-pin
HD cable |
|
0.5m 68-pin HDI to 68-pin
HD cable LVD/SE |
|
1.5m 68-pin HDI to 68-pin
HD cable LVD/SE |
C2979B
|
0.9m 68-pin HDI to 68-pin
HD cable LVD/SE |
C2911C
|
2.5m 68-pin HDI to 68-pin
HD cable LVD/SE |
C2924C
|
NOTE: For
use with Tape Array 5300 only |
|
|
|
Tape Autoloaders
|
DAT Autoloader
|
|
HP StorageWorks DAT 72x6 Internal
Autoloader |
Q1566A |
HP StorageWorks DAT 72x6 External
Autoloader |
Q1567A |
NOTE:
Please see the DAT Tape Autoloader QuickSpecs for additional options such
as host bus adapters, controllers and media:
https://h18000.www1.hp.com/products/quickspecs/11985_div/11985_div.html
(Worldwide)
https://h18000.www1.hp.com/products/quickspecs/11985_na/11985_na.html
(North America)
|
|
|
HP StorageWorks 1/8 Tape
Autoloader |
|
|
1/8 Ultrium 460 Tape Autoloader,
Tabletop
|
AA927A |
|
1/8 SDLT 320 Tape Autoloader,
Tabletop
|
AA926A |
|
1/8 Ultrium 230 Tape Autoloader,
Tabletop
|
C9572CB |
|
1/8 DLT VS80 Tape Autoloader,
Tabletop
|
C9264CB |
|
1/8 Tape Autoloader Rackmount
Kit
|
C9268R |
|
NOTE: Required
to install the 1/8 tape autoloader in a standard 19-inch rack
|
|
|
NOTE: Please reference
the 1/8 Tape Autoloader QuickSpecs at www.hp.com/go/automation for additional
information needed to create a complete solution; reference current compatibility
information at https://www.hp.com/go/ebs |
|
|
HP StorageWorks SSL1016
Tape Autoloader
|
|
|
SSL1016 Ultrium 460 Tape Autoloader
|
330821-B21 |
|
SSL1016 SDLT 320 Tape Autoloader
|
330816-B21 |
|
NOTE: Please reference
the SSL1016 Tape Autoloader QuickSpecs at https://www.hp.com/go/automation
for additional information needed to create a complete solution; reference
current compatibility information at https://www.hp.com/go/ebs |
|
|
Tape Libraries
|
HP StorageWorks MSL6000
Tape Library |
|
|
MSL6030, 1 drive, 30 slots, Ultrium
460, RM |
|
|
MSL6030, 2 drive, 30 slots, Ultrium
460, RM |
330731-B23 |
|
MSL6030, 1 drive, 30 slots, Ultrium
460, RM with embedded FC router |
330731-B24 |
|
MSL6030, 2 drive, 30 slots, Ultrium
460, RM with embedded FC router |
330731-B25 |
|
MSL6030, 1 drive, 30 slots, Ultrium
460, TT |
330788-B21 |
|
MSL6030, 2 drive, 30 slots, Ultrium
460, TT |
330788-B22 |
|
MSL6060, 2 drive, 60 slot, Ultrium
460, RM |
331196-B21 |
|
MSL6060, 2 drive, 60 slot, Ultrium
460, RM with embedded FC router |
331196-B22 |
|
MSL6060, 2 drive, 60 slot, Ultrium
460, TT |
331195-B21 |
|
NOTE: Please reference
the MSL6000 Tape Library QuickSpecs at https://www.hp.com/go/automation
for additional information needed to create a complete solution; reference
current compatibility information at https://www.hp.com/go/ebs |
|
|
HP StorageWorks MSL5026S2
Tape Library
|
|
|
MSL5026S2, 1 drive, 26 slots,
SDLT 320, RM |
293472-B22 |
|
MSL5026S2, 2 drive, 26 slots,
SDLT 320, RM |
293472-B23 |
|
MSL5026S2, 1 drive, 26 slots,
SDLT 320, RM with embedded FC router |
293472-B24 |
|
MSL5026S2, 2 drive, 26 slots,
SDLT 320, RM with embedded FC router |
293472-B25 |
|
MSL5026S2, 1 drive, 26 slots,
SDLT 320, TT |
293473-B21 |
|
MSL5026S2, 2 drive, 26 slots,
SDLT 320, TT |
293473-B22 |
|
NOTE:
Please reference the MSL5026S2
Tape Library QuickSpecs at https://www.hp.com/go/automation
for additional information needed to create a complete solution; reference
current compatibility information at https://www.hp.com/go/ebs |
|
|
HP StorageWorks MSL5052S2
Tape Library
|
|
|
MSL5052S2, 2 drive, 52 slots,
SDLT 320, RM |
293474-B21 |
|
MSL5052S2, 2 drive, 52 slots,
SDLT 320, RM with embedded FC router |
293474-B24 |
|
MSL5052S2, 2 drive, 52 slots,
SDLT 320, TT |
293476-B21 |
|
NOTE: Please reference
the MSL5052S2 Tape Library QuickSpecs at https://www.hp.com/go/automation
for additional information needed to create a complete solution; reference
current compatibility information at https://www.hp.com/go/ebs |
|
|
HP StorageWorks MSL5030
Tape Library
|
|
|
MSL5030, 1 drive, 30 slots, Ultrium
230, RM |
301897-B22 |
|
MSL5030, 2 drive, 30 slots, Ultrium
230, RM |
301897-B23 |
|
MSL5030, 1 drive, 30 slots, Ultrium
230, RM with embedded FC router |
301897-B24 |
|
MSL5030, 2 drive, 30 slots, Ultrium
230, RM with embedded FC router |
301897-B25 |
|
MSL5030, 1 drive, 30 slots, Ultrium
230, TT |
301898-B21 |
|
MSL5030, 2 drive, 30 slots, Ultrium
230, TT |
301898-B22 |
|
NOTE: Please reference
the MSL5030 Tape Library QuickSpecs at https://www.hp.com/go/automation
for additional information needed to create a complete solution; reference
current compatibility information at https://www.hp.com/go/ebs |
|
|
HP StorageWorks MSL5060
Tape Library
|
|
|
MSL5060, 2 drive, 60 slots, Ultrium
230, RM |
301899-B22 |
|
MSL5060, 2 drive, 60 slots, Ultrium
230, RM with embedded FC router |
301899-B23 |
|
MSL5060, 2 drive, 60 slots, Ultrium
230, TT |
301900-B21 |
|
NOTE: Please reference
the MSL5060 Tape Library QuickSpecs at https://www.hp.com/go/automation
for additional information needed to create a complete solution; reference
current compatibility information at https://www.hp.com/go/ebs |
|
|
HP StorageWorks ESL E-Series
Tape Libraries
|
|
|
ESL Extended 712e Tape Library,
0 drive, 712 LTO slots |
AA934B |
|
ESL Extended 630e Tape Library,
0 drive, 630 SDLT slots |
AA935B |
|
ESL Extended 322e Tape Library,
0 drive, 322 LTO slots |
AA939B |
|
ESL Extended 286e Tape Library,
0 drive, 286 SDLT slots |
AA940B |
|
ESL E-Series Ultrium 460 drive
kit |
AA937A |
|
ESL E-Series Ultrium 460-FC drive
kit |
AA941A |
|
ESL E-Series SDLT 320 drive kit |
AA936A |
|
ESL E-Series e2400-FC 2G Interface
Controller |
AA928A |
|
HP StorageWorks ESL9000
Series Tape Libraries
|
|
|
ESL9595 Extended Tape Library,
0 drive, 400 slots (card cage, Interface Mgr card, Command View license) |
343378-B21 |
|
ESL9322 Extended Tape Library,
0 drive, 222 slots (card cage, Interface Mgr card, Command View license) |
343377-B21 |
|
ESL9000 Ultrium 460 drive kit |
330834-B21 |
|
ESL9000 Ultrium 230 drive kit |
301930-B21 |
|
ESL9000 SDLT 320 drive kit |
293414-B21 |
|
NOTE: Please reference
the ESL9000 Series Tape Libraries QuickSpecs at https://www.hp.com/go/automation
for additional information needed to create a complete solution; reference
current compatibility information at https://www.hp.com/go/ebs |
|
|
Magneto-Optical Jukeboxes
|
HP StorageWorks 9.1 GB Entry-level
Optical Storage
|
|
220mx, 1 drive, 24 slot jukebox
|
C1118M |
|
220mx, 2 drive, 24 slot jukebox
|
C1119M |
|
NOTE: Please reference the Magneto-Optical
Jukebox data sheets at https://www.hp.com/go/optical
for additional information needed to create a complete solution |
|
|
HP StorageWorks 9.1 GB Mid-range Optical
Jukeboxes
|
|
|
300mx, 2 drive, 32 slot jukebox
|
C1150M |
|
600mx, 4 drive, 64 slot jukebox
|
C1160M |
|
700mx, 2 drive, 76 slot jukebox
|
C1170M
|
|
NOTE: Please reference the Magneto-Optical
Jukebox data sheets at https://www.hp.com/go/optical
for additional information needed to create a complete solution |
|
|
Ultra Density Optical Jukeboxes |
|
|
700ux, 1 drive, 24 slot jukebox |
AA962A |
|
700ux, 2 drive, 24 slot jukebox |
AA963A |
|
1100ux, 2 drive, 38 slot jukebox |
AA964A |
|
1000ux, 2 drive, 32 slot jukebox |
AA965A |
|
1900ux, 4 drive, 64 slot jukebox |
AA966A |
|
1900ux, 4 mixed drive, 64 slot jukebox |
AA968A |
|
2300ux, 2 drive, 76 slot jukebox |
AA967A |
|
NOTE: Please reference the
Ultra Density Optical Jukebox QuickSpecs at https://www.hp.com/go/optical
for additional information needed to create a complete solution |
|
|
External Storage
Tower & Rack |
HP StorageWorks Modular Smart
Array 20
NOTE: Rack-mountable 12 (SATA) drive
enclosure with U320 Host connectivity, redundant power supplies. |
|
HP StorageWorks Modular Smart
Array 20 Starter Kit
NOTE: Rack-mountable 12 (SATA) drive
enclosure with U320 Host connectivity, redundant power supplies. Includes
Smart Array 6402/128 Controller.
|
366172-B21
|
NOTE:
The Modular Smart Array Enclosure 20 Family supports the SATA 1.5Gb/s
1" Hot Plug Hard Drives.
|
|
HP StorageWorks Modular Smart
Array 30 SB
NOTE: Rack-mountable 14 drive enclosure
with single bus , redundant power supplies |
302969-B21
|
HP StorageWorks Modular Smart
Array 30 DB
NOTE: Rack-mountable 14 drive enclosure
with single bus , redundant power supplies |
302970-B21
|
NOTE: The Modular
Smart Array Enclosure 30 Family support the Wide Ultra3, Ultra320 1"
Hot Plug Hard Drives. |
|
Redundant Power Supply 499W |
|
StorageWorks Single Bus U320
I/O Module for MSA30 |
287484-B21
|
StorageWorks Dual Bus U320 I/O
Module for MSA30 |
287483-B21
|
|
HP StorageWorks
Modular Smart Array 1500 cs |
Modular Smart Array 1500 Controller Shelf
|
AA986A
|
NOTE: Please see
the StorageWorks Modular SAN Array 1500 cs QuickSpecs for additional options
and configuration information at:
https://www.hp.com/go/MSA1500cs
|
|
|
StorageWorks Options |
StorageWorks SAN Switch 2/16 |
|
|
Uninterruptible Power Systems – Tower Supply
|
HP UPS T1000 XR (1000 VA, 700
Watts), Low Voltage (NA) |
204155-001
|
HP UPS T1000 XR (1000 VA, 700
Watts), High Voltage (Int'l) |
204155-B31
|
HP UPS T1000 XR (1000VA, 700Watts)
100 VAC (JPN) |
312803-291
|
HP UPS T1500 XR (1440 VA, 1050
Watts) (NA) |
|
HP UPS T1500 XR (1500 VA, 1050
Watts) (Int'l) |
204155-B32
|
HP UPS T1500 XR (1500 VA, 1050
Watts) (Japan) |
204155-292
|
HP UPS T2200 XR (1920 VA, 1600
Watts) Low Voltage (NA) |
204451-001
|
HP UPS T2200 XR (2200 VA, 1600
Watts) High Voltage (NA) |
|
HP UPS T2200 XR (2200 VA, 1600
Watts) (Int'l) |
204451-B31
|
HP UPS T2200 XR (2200 VA, 1600
Watts) (Japan) |
204451-291
|
|
Uninterruptible Power Systems Rack
|
HP UPS R1500 XR (100 to 127) (NA) |
|
HP UPS R1500 XR (208 to 480) (Int'l) |
204404-B31
|
HP UPS R1500 XR (100 to 127) (Japan) |
204404-291
|
HP UPS R3000 XR (120V) (NA) |
|
HP UPS R3000 XR (208V) (NA) |
|
HP UPS R3000 XR (100V) (Japan) |
192186-291
|
HP UPS R3000 XR (208V) (Japan)
Compaq UPS R3000 XR (200V) (Japan) |
192186-292
|
HP UPS R3000 XR (230V) (Int'l
- detachable cord) |
192186-B31
|
HP UPS R3000 XR (230V) (16A IEC309
Plug) |
192186-B32
|
HP UPS R3000 XR (230V) (16A CEE
7/7 SCHUKO Plug) |
192186-B33
|
HP UPS R3000 XR (230V) (16A BS-546
Plug) |
192186-AR1
|
HP UPS R5500 XR, (5000VA, 4500
Watt), High Voltage (NA/Japan) |
|
HP UPS R5500 XR, (6000VA, 5400
Watt), High Voltage (Int'l) |
326529-B31
|
Extended Runtime Module R5500XR,
WW
NOTE: 3U each, two ERM maximum.
|
326564-B21
|
UPS R12000 XR N+ x (200-240V)
(WW-hardwired)
NOTE: The UPS R12000 XR has a hardwired
input and output connection. |
207552-B22
|
|
HP Power Distribution Unit with Power Monitoring.
|
HP Power Distribution Unit with
Power Monitoring Model S2324 - dual input, 3 phase, 24A (NA/JPN) |
|
HP Power Distribution Unit with
Power Monitoring Model S1324 - single input, 3 phase, 24A (NA/JPN) |
|
HP Power Distribution Unit with
Power Monitoring Model S2140 - dual input, 1 phase, 40A (NA/JPN) |
|
HP Power Distribution Unit with
Power Monitoring Model S1140 - single input, 1 phase, 40A (NA/JPN) |
|
HP Power Distribution Unit with
Power Monitoring Model S2316 - dual input, 3 phase, 16A (INTL) |
370963-B31
|
HP Power Distribution Unit with
Power Monitoring Model S1316 - single input, 3 phase, 16A (INTL) |
370964-B31
|
HP Power Distribution Unit with
Power Monitoring Model S2132 - dual input, 1 phase, 32A (INTL) |
370965-B31
|
HP Power Distribution Unit with
Power Monitoring Model S1132 - single input, 1 phase, 32A (INTL) |
370966-B31
|
|
Modular PDUs 1U/0U (up to 32 outlets)
NOTE: 1U/0U mounting brackets shipped
with the unit (optimized for 10000
and 9000 series racks).
|
HP Modular Power Distribution
Units (mPDU), Low Volt Model, 24A (100-127 VAC) (NA, Japan)
NOTE: The above mPDU may also be
used to connect to the low volt model of the UPS R3000 XR. |
|
HP Modular Power Distribution
Units (mPDU), High Volt Model, 24A (200-240 VAC) (NA, Japan)
NOTE:
L6-30 input. |
|
HP Modular Power Distribution
Units (mPDU), High Volt Model, 32A (200-240 VAC) (Int'l) |
252663-B31
|
HP Modular Power Distribution
Units (mPDU), High Volt Model, 40A (200-240 VAC) (WW)
NOTE:
The 40A model has a hardwired
input. |
|
HP Modular Power Distribution
Units (mPDU), High Volt Model, 16A (200-240 VAC) (WW)
NOTE: This PDU has a detachable input
power cord and allows for adaptability to country specific power requirements.
This model may also be used with the high volt UPSs R3000 XR and R6000.
|
|
HP Modular Power Distribution
Unit (mPDU), High Volt Model, 40A, Attached Cord, (NA/JPN) |
252663-D73
|
HP Modular Power Distribution
Unit (mPDU), High Volt Model, 40A, Attached Cord, (Int'l) |
252663-B32
|
NOTE: Please see
the following Modular Power Distribution Unit (Zero-U/1U Modular PDUs) QuickSpecs
for additional options including shorter jumper cables and country specific
power cords:
https://h18000.www1.hp.com/products/quickspecs/11041_na/11041_na.html
(North America)
https://h18000.www1.hp.com/products/quickspecs/11041_div/11041_div.html
(Worldwide) |
|
|
USB Options |
USB 2-Button Optical Scroll Mouse
(Carbonite/Silver) |
DC172B |
|
USB 1.44-MB External Diskette
Drive (Carbonite) |
DC141B
|
Rack Conversion Kit
|
ProLiant ML5xx G2 Tower to Rack
Conversion Kit |
253699-B21
|
ProLiant ML5xx G2 Rack to Tower
Conversion Kit
|
271258-B21
|
|
HP Rack 5000 Series (Graphite
Metallic) |
HP 5642 Rack-Unassembled |
|
|
Rack Options for Rack
5000 Series |
Stabilizer Kit for 5642 rack (Graphite
Carbon)
NOTE: The stabilizing kit is used
to prevent rack from tipping over.
|
374493-B21
|
Baying Kit for 5642 rack (Graphite
Carbon)
NOTE: The baying kit is used to join
two or more HP 5642 racks.
|
374499-B21
|
|
HP Rack 10000 Series
(Graphite Metallic)
|
10642 (42U) Infrastructure Rack
(Low Voltage) |
379006-001
|
10642 (42U) Infrastructure Rack
(High Voltage) |
|
HP Rack S10614 (14U) Rack Cabinet
Shock Pallet |
|
HP Rack 10842 (42U, 800mm wide) – Pallet
|
257415-B21
|
HP Rack 10842 (42U, 800mm wide) – Shock Pallet
|
257415-B22
|
HP Rack 10647 (47U) – Pallet
|
245160-B21
|
HP Rack 10647 (47U) – Crated
|
245160-B23
|
HP Rack 10642 (42U) – Pallet
|
245161-B21
|
HP Rack 10642 (42U) – Shock Pallet
|
245161-B22
|
HP Rack 10642 (42U) – Crated
|
245161-B23
|
HP Rack 10636 (36U) – Pallet
|
245162-B21
|
HP Rack 10636 (36U) – Shock Pallet
|
245162-B22
|
HP Rack 10636 (36U) – Crated
|
245162-B23
|
HP Rack 10622 (22U) – Pallet
|
245163-B21
|
HP Rack 10622 (22U) – Shock Pallet
|
245163-B22
|
HP Rack 10622 (22U) – Crated
|
245163-B23
|
HP Rack 10614 (14U) – Shock Pallet
|
292303-B22
|
NOTE: -B21 (pallet) used to ship empty
racks shipped on a truck
-B22 (shock pallet) used to ship racks with equipment installed (by custom
systems, VARs and Channels)
-B23 (crated) used for air shipments of empty racks
|
|
NOTE: It is mandatory to use a shock
pallet in order to ship racks with equipment installed. Not all HP equipment
is qualified to be shipped in the Rack 10000 series
|
|
NOTE: Please see the Rack 10000 QuickSpecs
for Technical Specifications such as height, width, depth, weight, and
color:
https://h18000.www1.hp.com/products/quickspecs/10995_div/10995_div.html
(Worldwide)
https://h18000.www1.hp.com/products/quickspecs/10995_na/10995_na.html
(North America)
|
|
NOTE: For additional information regarding
Rack Cabinets, please see the following URL: https://h18000.www1.hp.com/products/servers/proliantstorage/rack-options/index.html.
|
|
|
Rack Options for HP
Rack 10000 Series |
NOTE: For additional
information regarding Rack Options, please see the following URL: https://h18000.www1.hp.com/products/servers/proliantstorage/rack-options/index.html. |
|
HP Rack Light Kit (Neon) |
|
HP Rack Plinth Kit (Carbon) |
|
42U Side Panel – Graphite Metallic
|
246099-B21
|
36U Side Panel – Graphite Metallic
|
246102-B21
|
47U Side Panel – Graphite Metallic
|
255486-B21
|
TFT5600 Rack Keyboard Monitor
|
221546-xx1
|
Country Code Key (for
TFT5600 Rack Keyboard Monitor (PN 221546-xx1)) |
|
XX = 001 |
US |
XX = 091 |
Norway |
XX = 031 |
UK |
XX = 101 |
Sweden/Finland |
XX = 041 |
Germany |
XX = 111 |
Switzerland |
XX = 051 |
France |
XX = 131 |
Portugal |
XX = 061 |
Italy |
XX = 181 |
Belgium |
XX = 071 |
Spain |
XX = 291 |
Japan |
XX = 081 |
Denmark |
XX = B31 |
International |
|
|
1U Rack Keyboard & Drawer
(Carbon)
|
257054-xx1
|
Country Code Key (for
1U Rack Keyboard & Drawer (PN 257054-xx1)) |
|
XX = 001 |
US |
XX = 091 |
Norway |
XX = 031 |
UK |
XX = 101 |
Sweden/Finland |
XX = 041 |
Germany |
XX = 111 |
Switzerland |
XX = 051 |
France |
XX = 131 |
Portugal |
XX = 061 |
Italy |
XX = 181 |
Belgium |
XX = 071 |
Spain |
XX = 291 |
Japan |
XX = 081 |
Denmark |
XX = B31 |
International |
|
|
NOTE: For additional
information regarding Rack Options, please see the following URL: https://h18000.www1.hp.com/products/servers/proliantstorage/rack-options/index.html. |
|
|
HP KVM Switch Options |
Server Console Switch (KVM), 0
x 1 x 8 port |
|
Server Console Switch (KVM), 0
x 2 x 16 port |
|
IP Console Switch Box (KVM/IP),
1 x 1 x 16 |
|
IP Console Switch Box (KVM/IP),
3 x 1 x 16 |
|
HP 1x4 USB/PS2 KVM Switch, RM
(ALL) |
371302-B21
|
HP 1x4 USB/PS2 KVM Switch, TT,
(EURO) |
371301-A21
|
HP 1x4 USB/PS2 KVM Switch, TT
(UK) |
371301-031
|
HP 1x4 USB/PS2 KVM Switch, TT,
(AUST/NZ) |
371301-011
|
HP 1x4 USB/PS2 KVM Switch, TT,
(NA/JPN) |
371301-D71
|
PS/2 Interface Adapter, 8 pack |
|
PS/2 Interface Adapter, 1 pack |
|
CAT5 KVM Expansion Module |
|
Serial Interface adapter - 1 Pack
with power supply |
|
CAT5e Cable 3', 4 pack |
|
CAT5e Cable 6', 8 pack |
|
CAT5e Cable 12', 8 pack |
|
CAT5e Cable 20', 4 pack |
|
CAT5e Cable 40', 1 pack |
|
NOTE: For additional
information regarding HP KVM Switches and options, please see the following
URL:
https://h18004.www1.hp.com/products/servers/proliantstorage/rack-options/list.html#console
|
|
|
Rack Options for Third Party Cabinet Racks
|
Rack Adapter Kit
NOTE: This kit allows HP rack servers
to fit in racks that are 24" wide.
|
332815-B21
|
|
Third Party Rack Kit
NOTE: The Third party rack kit is
required for round hole racks or for square hole racks that do not conform
to the adjustment range of the standard rail that ships with the server. |
274739-B21
|
|
HP Factory Express |
Factory Installation, Racking, and Customization Services |
|
Factory Express Server Configuration Level 1 |
293355-888 | NOTE:
Free Installation of HP Options - Installation of HP Options memory, NICs, hard
drives, controllers, processors, I/O cards, pre-install standard OEM OS image,
and tape drives. Installation fees will apply to all non-HP certified hardware
and asset tags. | |
Factory Express Server Configuration
Level 2 | 266326-888 |
NOTE:
Includes Level 1 Customer Intent of a ProLiant server and options configuration,
OS installation, custom image download, IP addressing, network setting, and custom
packaging. Customer unique requirements (quick restore creation, cd duplication,
test reports, real-time reporting of server MAC address, password, and RILOE).
Customer access, validation and control through VPN (price/server). | |
Factory Express Rack Integration
Level 3 with 1 3 servers or storage enclosures |
325736-888 | Factory
Express Rack Integration Level 3 with 4 9 servers or storage enclosures |
232539-888 | Factory
Express Rack Integration Level 3 with 10 or more servers or storage enclosures |
325735-888 | NOTE:
Includes Level 1 Customer Intent for standard mounted servers and storage units
plus standard cable mgmt, RAID configuration, servers & storage, power distribution,
networking gear and accessories (price/rack). NOTE:
Available on ProLiant rack models only.
| |
Factory Express Rack Integration
Level 4 with 1 3 servers or storage enclosures |
325734-888 | Factory
Express Rack Integration Level 4 with 4 9 servers or storage enclosures |
232540-888 | Factory
Express Rack Integration Level 4 with 10 or more servers or storage enclosures |
325733-888 | NOTE:
Includes Level 2 Customer Intent plus customer defined cable management and naming
convention, customer furnished image download, IP addressing, cluster configurations
(SQL, External storage RAID). Quick restore creation, cd duplication, test reports,
real-time reporting of server MAC address, password, RILOE). Customer access and
validation through VPN (price/rack). NOTE:
Available on ProLiant rack models only.
| |
Factory Express Rack Integration
Level 5 with 1 3 servers or storage enclosures |
325732-888 | Factory
Express Rack Integration Level 5 with 4 9 servers or storage enclosures |
232541-888 | Factory
Express Rack Integration Level 5 with 10 or more servers or storage enclosures |
325731-888 | NOTE:
Includes Level 4 Customer Intent plus Custom SW layering and extended test, Customer
access, validation and control through VPN, Clustered racks with networking gear
and / or external storage array, Start-up installation services custom quote.
(price/rack). NOTE:
Available on ProLiant rack models only. NOTE:
Factory Express Engineered Solution Level 6 is a custom solutions available through
Factory Express. Please contact your local reseller or Account Manager.
|
|
|
Service and Support Offerings (HP
Care Pack Services)
|
Hardware Services
On-site Service |
|
Next Business Day On-site
Service, 5-Day x 9-Hour Coverage, 3 Years |
U4462A
|
Next Business Day On-site
Service, 5-Day x 9-Hour Coverage, 3 Years, Electronic |
U4462E
|
4-Hour On-site Service,
5-Day x 13-Hour Coverage, 3 Years |
U4463A
|
4-Hour On-site Service,
5-Day x 13-Hour Coverage, 3 Years, Electronic |
U4463E
|
4-Hour On-site Service,
7-Day x 24-Hour Coverage, 3 Years |
U4464A
|
4-Hour On-site Service,
7-Day x 24-Hour Coverage, 3 Years, Electronic |
U4464E
|
6-Hour Call to Repair, On-site
Service, 7-Day x 24-Hour Coverage, 3 Years |
U4465A
|
6-Hour Call to Repair, On-site
Service, 7-Day x 24-Hour Coverage, 3 Years, Electronic |
U4465E
|
|
Installation &
Start-up Services |
|
Hardware Installation |
U4473A
|
Hardware Installation, Electronic |
U4473E
|
Installation & Start-Up
of a ProLiant server and Microsoft or Linux O/S per the Customer Description
and/or Data Sheet. To be delivered on a scheduled basis 8am-5pm, M-F,
excl. HP holidays. |
U4474A
|
Installation & Start-Up
of a ProLiant server and Microsoft or Linux O/S per the Customer Description
and/or Data Sheet. To be delivered on a scheduled basis 8am-5pm, M-F,
excl. HP holidays, Electronic |
U4474E
|
|
Support Plus |
|
Onsite HW support, 8am-9pm,
M-F, 4hr response and Microsoft O/S SW Tech support offsite, onsite
at HP's discretion, 8am-9pm, M-F 2hr response time excl. HP holidays. |
U4475A
|
Onsite HW support, 8am-9pm,
M-F, 4hr response and Microsoft O/S SW Tech support offsite, onsite
at HP's discretion, 8am-9pm, M-F 2hr response time excl. HP holidays,
Electronic |
U4475E
|
Onsite HW support, 8am-9pm,
M-F, 4hr response and Linux O/S SW Tech support offsite, onsite at
HP's discretion, 8am-9pm, M-F 2hr response time excl. HP holidays. |
U4477A
|
Onsite HW support, 8am-9pm,
M-F, 4hr response and Linux O/S SW Tech support offsite, onsite at
HP's discretion, 8am-9pm, M-F 2hr response time excl. HP holidays,
Electcronic |
U4477E
|
|
Support Plus 24 |
|
Onsite HW support 24x7,
4hr response and Microsoft O/S SW Tech support offsite, onsite at
HP's discretion, 24x7 2hr response time incl. HP holidays. |
U4476A
|
Onsite HW support 24x7,
4hr response and Microsoft O/S SW Tech support offsite, onsite at
HP's discretion, 24x7 2hr response time incl. HP holidays, Electronic |
U4476E
|
Onsite HW support 24x7,
4hr response and Linux O/S SW Tech support offsite, onsite at HP's
discretion, 24x7 2hr response time incl. HP holidays. |
U4478A
|
Onsite HW support 24x7,
4hr response and Linux O/S SW Tech support offsite, onsite at HP's
discretion, 24x7 2hr response time incl. HP holidays, Electronic |
U4478E
|
|
|
Memory
HP ProLiant ML530 Generation 2 (G2)
|
Advanced ECC Memory Standard
1024 MB (2 x 512-MB) PC1600- ECC SDRAM installed
Advanced ECC Memory Standard Plus Optional Memory
Up to 13,312-MB memory is available with the optional installation of
PC1600- ECC SDRAM memory kits
Advanced ECC Memory Standard Replaced with Optional
Memory
Up to 16,384-MB of memory is available with the removal of the standard
1024-MB of memory and the optional installation of PC1600-MHz ECC SDRAM
memory kits.
NOTE: This chart does not represent
all possible memory configurations.
|
|
Bank A
|
Bank B
|
Bank C
|
Bank D
|
|
Slot 1
|
Slot 2
|
Slot 3
|
Slot 4
|
Slot 5
|
Slot 6
|
Slot 7
|
Slot 8
|
Standard
|
1024 MB
|
512 MB
|
512 MB
|
Empty
|
Empty
|
Empty
|
Empty
|
Empty
|
Empty
|
Optional
|
13,312 MB
|
512 MB
|
512 MB
|
2048 MB
|
2048 MB
|
2048 MB
|
2048 MB
|
2048 MB
|
2048 MB
|
Maximum
|
16,384 MB
|
2048 MB
|
2048 MB
|
2048 MB
|
2048 MB
|
2048 MB
|
2048 MB
|
2048 MB
|
2048 MB
|
Optional Compaq Advanced Memory Protection Configurations
|
NOTE:
-Online Spare Memory: Bank D is the Online Spare Bank.
-Mirrored Memory: Bank C mirrors Bank A, Bank D mirrors Bank B.
NOTE: This chart does not represent all possible memory configurations.
|
|
Bank A
|
Bank B
|
Bank C
|
Bank D
|
|
Slot 1
|
Slot 2
|
Slot 3
|
Slot 4
|
Slot 5
|
Slot 6
|
Slot 7
|
Slot 8
|
Online
|
2560 MB
|
512 MB
|
512 MB
|
256 MB
|
256 MB
|
Empty
|
Empty
|
512 MB
|
512 MB
|
Mirrored
|
3072 MB
|
512 MB
|
512 MB
|
256 MB
|
256 MB
|
512 MB
|
512 MB
|
256 MB
|
256 MB
|
|
Following are memory options available from HP:
|
|
- 512-MB PC1600-MHz Registered ECC SDRAM Memory Option Kit (2 x 256
MB)
|
187418-B21 |
- 1024-MB PC1600-MHz Registered ECC SDRAM Memory Option Kit (2 x 512
MB)
|
187419-B21
|
- 2048-MB PC1600-MHz Registered ECC SDRAM Memory Option Kit (2 x 1024
MB)
|
|
- 4096-MB PC1600-MHz Registered ECC SDRAM Memory Option Kit (2 x 2048
MB)
|
|
Storage

|
2X 0 - 5 | Two
6 x1 inch Wide Ultra3 SCSI Hard Drive Cages |
A | 1.44-MB
Diskette Drive | B | 40x
IDE CD-ROM | C,
D | Two available half height
bays for tape backup, DVD, SCSI storage, or optional ML5xx Internal Two Bay Hot
Plug Wide SCSI Drive Cage (with fan) | | |

|
2X 0 - 5 | Two
6 x1 inch Wide Ultra3 SCSI Hard Drive Cages |
A | 1.44-MB
Diskette Drive | B | 40x
IDE CD-ROM | C,
D | Two available half height
bays for tape backup, DVD, SCSI storage, or optional ML5xx Internal Two Bay Hot
Plug Wide SCSI Drive Cage (with fan) | | |
|
Drive Support
|
|
|
Quantity
Supported
|
Position
Supported
|
Controller
|
Removable Media
|
|
|
|
1.44-MB Diskette Drive |
Up to 1 |
A |
Integrated |
IDE CD-ROM Drive |
Up to 1 |
B |
Integrated IDE |
DVD-ROM Drive Option Kit |
Up to 1 |
B, C, D |
Integrated IDE |
ML5xx Internal Two Bay Hot Plug
Wide SCSI Drive Cage (with fan) |
Up to 1 |
C, D |
Integrated SCSI |
|
Hard Drives
|
Ultra320 Hot Pluggable Drives |
|
Quantity
Supported
|
Position
Supported |
Controller
|
1-inch Drives
|
Up to
12
Up to 14 (With optional Drive Cage and ML5xx
Internal Two Bay Hot Plug Wide SCSI Drive Cage) |
2X 0-5
2X 0-5, C, D |
Integrated Dual Channel Wide Ultra3 SCSI Adapter
Smart Array 6402/128 Controller
Smart Array 6404/256 Controller
Smart Array 641 Controller
Smart Array 642 Controller
64-bit/66-MHz Dual Channel Wide Ultra3 SCSI Adapter, Alternate OS
64-Bit/133-MHz Dual Channel Ultra320 SCSI Adapter
|
|
300-GB 10,000 rpm
146.8-GB 10,000 rpm
72.8-GB 10,000 rpm
72.8-GB 15,000 rpm
36.4-GB 15,000 rpm |
NOTE: All U320 Universal
Hard Drives are backward compatible to U2 or U3 speeds. U320 drives require
an optional U320 Smart Array Controller or U320 SCSI HBA to support U320
transfer rates |
|
External Storage
|
|
Quantity
Supported
|
Position
Supported
|
Host Controller or Adapter
|
|
Modular Smart Array 30 Family
|
Up to 28
|
External
|
Smart Array 6402/128 Controller
Smart Array 6404/256 Controller
Smart Array 642 Controller
64-Bit/133-MHz Dual Channel Ultra320 SCSI Adapter
64-Bit/66-MHz Dual Channel Wide Ultra3 SCSI Adapter, Alternate OS
|
|
Modular Smart Array 1000 |
Please see
the Modular Smart Array 1000 QuickSpecs below to determine configuration
requirements |
External |
Please see the Modular Smart Array
1000 QuickSpecs (URL below) for the latest list of supported HBAs |
|
Modular Smart Array 1500 cs |
Please see
the Modular Smart Array 1500 QuickSpecs below to determine configuration
requirements |
External |
Please see the Modular Smart Array
1500 cs QuickSpecs (URL below) for the latest list of supported HBAs |
|
Modular Smart Array 1000:
https://h18000.www1.hp.com/products/quickspecs/11033_div/11033_div.html
(Worldwide)
https://h18000.www1.hp.com/products/quickspecs/11033_na/11033_na.html
(North America)
Modular Smart Array 1500 cs: https://www.hp.com/go/MSA1500cs
|
|
Maximum Storage Capacity (Ultra3 Drive Cage, ML5xx Two
Bay Hot Plug SCSI Drive Cage, 4 channel controller in all 7 slots &
MSA30 enclosures)
|
Internal |
4.20 TB (14 x 300
GB Ultra320 1" Drives) |
External |
117.60 TB (28 Enclosures
each with 14 x 300 GB Ultra320 1" Drives) |
Total |
121.80 TB |
|
Tape Drives, Tape
Autoloaders & Tape Libraries |
NOTE: For an up-to-date listing of the latest
O/S Support details for each of the Tape Drives listed below, please see
the following:
https://h18000.www1.hp.com/products/quickspecs/north_america/10233.html
(North America)
https://h18000.www1.hp.com/products/quickspecs/division/10233.html
(Worldwide)
NOTE: For an up-to-date listing of the latest
O/S Support details for each of the Tape Autoloaders and Tape Libraries
listed below, please see the following:
https://h18000.www1.hp.com/products/quickspecs/north_america/10809.html
(North America)
https://h18000.www1.hp.com/products/quickspecs/division/10809.html
(Worldwide)
NOTE: For complete listing of tape drive offerings
see https://www.hp.com/products1/storage/compatibility/tapebackup/ISS/index.html
|
|
Quantity
Supported
|
Position
Supported
|
Controller
|
|
HP StorageWorks DAT 40 Tape Drive, Internal Hot-Plug
HP StorageWorks DAT 72 Tape Drive, Internal Hot-Plug
|
Up to 3 per drive cage.
NOTE: drives are 1.5 height devices
|
0-4 per drive cage
|
Smart Array 6402/128 Controller
Smart Array 6404/256 Controller
Smart Array 642 Controller
Smart Array 641 Controller
64-Bit/133-MHz Dual Channel Ultra320 SCSI Adapter
64-Bit/66-MHz Dual Channel Wide Ultra3 SCSI Adapter, Alternate OS |
|
|
|
|
Ultrium 230, Internal
Ultrium 460, Internal |
1
|
C + D
|
Integrated Dual Channel Wide Ultra3
Adapter
64-Bit/133Mhz Dual Channel Ultra320 SCSI Adapter
64-Bit/66-MHz Dual Channel Wide Ultra3 SCSI Adapter, Alternate OS |
|
|
|
|
HP StorageWorks DAT 72 Tape Drive,
Internal
HP StorageWorks DAT 40 Tape Drive, Internal
HP StorageWorks DAT 24 Tape Drive, Internal |
2
|
C, D
|
Integrated Dual Channel Wide Ultra3
Adapter
64-Bit/133Mhz Dual Channel Ultra320 SCSI Adapter
64-Bit/66-MHz Dual Channel Wide Ultra3 SCSI Adapter, Alternate OS |
|
|
|
|
HP StorageWorks DLT VS80 Tape
Drive, Internal
HP StorageWorks SDLT 320 Tape Drive, Internal |
1
|
C + D
|
Integrated Dual Channel Wide Ultra3
Adapter
64-Bit/133Mhz Dual Channel Ultra320 SCSI Adapter
64-Bit/66-MHz Dual Channel Wide Ultra3 SCSI Adapter, Alternate OS |
|
|
|
|
Ultrium 215, External
Ultrium 230, External
Ultrium 460, External |
Up to 2
|
External
|
Integrated Dual Channel Wide Ultra3
Adapter
64-Bit/133Mhz Dual Channel Ultra320 SCSI Adapter
64-Bit/66-MHz Dual Channel Wide Ultra3 SCSI Adapter, Alternate OS
|
|
|
|
|
HP StorageWorks DAT 72 Tape Drive,
External
HP StorageWorks DAT 40 Tape Drive, External
HP StorageWorks DAT 24 Tape Drive, External |
Up to 2
|
External
|
Integrated Dual Channel Wide Ultra3
Adapter
64-Bit/133Mhz Dual Channel Ultra320 SCSI Adapter
64-Bit/66-MHz Dual Channel Wide Ultra3 SCSI Adapter, Alternate OS
|
|
|
|
|
HP StorageWorks DLT VS80 Tape
Drive, External |
Up to 2
|
External
|
Integrated Dual Channel Wide Ultra3
Adapter
64-Bit/133Mhz Dual Channel Ultra320 SCSI Adapter
64-Bit/66-MHz Dual Channel Wide Ultra3 SCSI Adapter, Alternate OS |
|
|
|
|
HP StorageWorks SDLT 320 Tape
Drive, External |
Up to 2
|
External
|
Integrated Dual Channel Wide Ultra3
Adapter
64-Bit/133Mhz Dual Channel Ultra320 SCSI Adapter
64-Bit/66-MHz Dual Channel Wide Ultra3 SCSI Adapter, Alternate OS |
|
|
|
|
HP StorageWorks DAT 40x6 Tape
Autoloader, Internal |
1
|
C+D
|
64-Bit/133Mhz Dual Channel Ultra320
SCSI Adapter
64-Bit/66-MHz Dual Channel Wide Ultra3 SCSI Adapter, Alternate OS |
|
|
|
|
HP StorageWorks DAT 72x6 Tape
Autoloader, External
HP StorageWorks DAT 40x6 Tape Autoloader, External
1/8 Ultrium 460 Tape Autoloader
1/8 SDLT 320 Tape Autoloader
1/8 Ultrium 230 Tape Autoloader
1/8 DLT VS80 Tape Autoloader
SSL1016 Ultrium 460 Tape Autoloader
SSL1016 SDLT320 Tape Autoloader
SSL1016 DLT1 Tape Autoloader |
1 autoloader per SCSI channel
|
External
|
64-Bit/133Mhz Dual Channel Ultra320
SCSI Adapter
64-Bit/66-MHz Dual Channel Wide Ultra3 SCSI Adapter, Alternate OS
|
|
|
|
|
MSL6060 (Ultrium 460 -based) Library
MSL6030 (Ultrium 460 -based) Library
MSL5052S (320 SDLT-based) Library
MSL5030 (Ultrium 230 -based) Library
MSL5060 (Ultrium 230 -based) Library
|
Please reference the MSL Tape Library QuickSpecs to determine
configuration requirements
|
External
|
64-Bit/133Mhz Dual Channel Ultra320
SCSI Adapter
64-Bit/66-MHz Dual Channel Wide Ultra3 SCSI Adapter, Alternate OS
|
|
|
|
|
ESL 712e
ESL 630e
ESL9322 ETLA
ESL9595 ETLA
|
Please reference the
ESL E-Series and ESL9000 Series Tape Libraries QuickSpecs to determine configuration
requirements |
External
|
64-Bit/133Mhz Dual Channel Ultra320
SCSI Adapter
64-Bit/66-MHz Dual Channel Wide Ultra3 SCSI Adapter, Alternate OS |
ESL9000 Serries: https://h18000.www1.hp.com/products/quickspecs/11875_div/11875_div.html
|
Power Specifications
Part Number | 230822-001 |
Spare Kit | 231782-001 |
Operational Input Voltage Range
(V rms) | 90 to 264 |
Frequency Range (Nominal) (Hz) | 47
to 63 (50/60) | |
|
Nominal
Input Voltage (Vrms) | 100 |
115 | 208 |
220 | 230 |
240 | Max
Rated Output Wattage Rating | 600 |
600 | 600 |
600 | 600 |
600 | Nominal
Input Current (A rms) | 9.4 |
8.1 | 4.4 |
4.1 | 3.9 |
3.6 | Max
Rated Input Wattage Rating (Watts) | 923 |
909 | 914 |
882 | 870 |
857 | Max.
Rated VA (Volt-Amp) | 942 |
928 | 914 |
900 | 887 |
875 |
Efficiency (%) | 65 |
66 | 67 |
68 | 69 |
70 |
Power Factor | 0.98 |
Leakage Current (mA) |
0.31 | 0.36 |
0.65 | 0.69 |
0.72 | 0.75 |
Maximum Inrush Current
(A peak) | 15 |
17 | 30 |
32 | 34 |
35 |
Maximum Inrush Current duration (mS) |
20 |
| Processor |
Memory | HDD |
PCI | PS |
| ML530
G2 Fully Configured | 2 |
16 | 12 |
7 | 2 |
| Fully
Loaded System Input Wattage (W) | 902 |
888 | 875 |
862 | 850 |
838 | Fully
Loaded System Input Current (A rms) | 9.2 |
7.9 | 4.3 |
4.0 | 3.8 |
3.6 | Fully
Loaded System Thermal (BTU-Hr) | 3076 |
3029 | 2984 |
2940 | 2898 |
2856 | Fully
Loaded System VA (Volt-Amp) | 920 |
906 | 893 |
880 | 867 |
855 | Power
cord requirements | Nema 5-15P to IEC320-C13 | Option
no./Spare no.: See Power Cord chart | | IEC320-C13
to IEC320-C14 | Option no. /Spare no.: 142259-001/142258-B21 |
NOTES: ActiveAnswers Power Calculation Power calculator
is LIVE on ActiveAnswers website. This is an external link. Follow this link:
https://h30099.www3.hp.com/configurator/powercalcs.asp.
To drill down to calculators: - Click on: "ProLiant
Servers" - Click on the Server of interest. Example:
ML530 G2 - Click on: "Power Calculator" link (You
may need to scroll down to see it.) |
|
Power
Cords (13 Cord Sets) | Power
Cord Part Number | Country | |
APD | 139867-006 |
APD | 100613-003 |
APD | 100614-003 |
Australia | 100611-007 |
Europe | 100614-003 |
France | 100614-003 |
Germany | 100614-003 |
Japan | 139867-006 |
PRC | 139867-006 |
PRC | 100613-003 |
PRC | 100661-007 |
UK | 100613-003 |
US | 163719-002 |
Quickspecs
System Unit Tower |
Dimensions (HxWxD) (with feet/bezel) | 20.0
x 12.8 x 27.8 in (50.8 x 32.5 x 70.6 cm) | Weight | 100
lb (45.36 kg) | No
hard drives installed, one power supply |
Input Requirements (per power supply) |
Range Input Voltage | 100
to 127 VAC/200 to 240 VAC | Rated
Input Frequency | 47 to 63 Hz |
Input Power | 690W
@ 110 VAC | Rated Input
Current | 7.6A | BTU
Rating | 2400 BTU/hr | |
SCSI Connectors
| Two internal HD68
connectors (supporting Wide Ultra3) | One
external VHDCI connector (supporting Wide Ultra3) | One
SCSI knockout | Power
Supply Output Power (per power supply) | Rated
Steady-State Power | 600W |
Maximum Peak Power | |
Acoustic Noise
| Idle (Fixed Disk Drives
Spinning) | |
L WAd (BELS) | 7.0 |
Operating
(Random Seeks to Fixed Disks) | |
L
WAd (BELS) | 7.1 |
|
System Unit Rack | Dimensions
(HxWxD) | 12.8 x 17.5 x 25.6
in (32.5 x 44.4 x 65.0 cm) | Weight
(approximate) | 100 lb (45.36 kg) |
No hard drives
installed, one power supply |
Input Requirements (per power supply) |
Range Input Voltage | 100
to 127 VAC/200 to 240 VAC | Rated
Input Frequency | 47 to 63 Hz |
Input Power | 690W
@ 110 VAC | Rated Input
Current | 7.6A | BTU
Rating | 2400 BTU/hr | |
SCSI Connectors
| Two internal HD68 connectors
(supporting Wide Ultra3) | One
external VHDCI connector (supporting Wide Ultra3) | One
SCSI knockout | Power
Supply Output Power (per power supply) | Rated
Steady-State Power | 600W |
Maximum Peak Power | |
Acoustic Noise
| Idle (Fixed Disk Drives
Spinning) | |
L WAd (BELS) | 6.7 |
Operating
(Random Seeks to Fixed Disks) | |
L
WAd (BELS) | 6.8 |
|
40X Max IDE
CD-ROM Drive
|
Disk
|
Applicable Disk
|
CD-ROM, CD-XA, CD-DA (Mode 1, Mode
2, Form 1 and 2) |
|
Photo CD (Single and Multi-session) |
|
Mixed Mode (Audio and Data combined) |
|
|
CD-R |
|
Capacity
|
540 MB (Mode 1, 12 cm) |
|
|
650 MB (Mode 2, 12 cm) |
Block Size
|
Mode 1
|
2,048 bytes |
|
Mode 2
|
2,340 bytes, 2,336 bytes |
|
CD-DA
|
2,352 bytes |
|
CD-XA |
2,328 bytes |
Interface
|
IDE (ATAPI)
|
|
Access Times (typical)
|
Random
|
100 ms |
Full-Stroke
|
150 ms |
Audio Output Level
|
Line-Out |
0.7 VRMS at 47 kOhms |
Data Transfer Rate |
Sustained
|
150 KB/s (1X audio) |
Burst |
16.67 Mbytes/sec |
Cache Buffer
|
128 KB
|
|
Start-up Time (typical)
|
< 7 seconds
|
|
Stop Time |
< 4 seconds |
|
Laser Parameters
|
Type |
Semiconductor Laser GaA1As |
Wave Length
|
780 ± 25 nm |
Operating Conditions
|
Temperature
|
41° to 113° F (5° to
45° C) |
Humidity
|
10% to 80% |
Dimensions
|
(HxWxD, maximum)
|
1.7 x 5.85 x 8.11 in (4.29 x 14.86
x 20.60 cm) |
|
Weight
|
2.09 lb (0.95 kg) |
|
Integrated Dual Channel Wide Ultra3 SCSI Adapter
|
Drives Supported |
Up to 15 SCSI devices per channel |
Data Transfer Method |
64-bit PCI bus-master |
SCSI Channel Transfer Rate |
160 MB/s per channel |
Maximum Transfer Rate per PCI
Bus (peak) |
267 MB/s |
SCSI Termination |
Active Termination |
SCSI Connectors |
1 external, 2 internal (68-pin) |
|
Compaq NC3163 Fast Ethernet NIC Embedded 10/100 WOL (Wake On LAN) | Network
Interface | 10Base-T/100Base-TX |
Compatibility | IEEE
802.3/802.3u compliant | Data
Transfer Method | 32-bit
bus-master PCI | Network
Transfer Rate | 10Base-T (Half-Duplex) | 10
Mb/s | 10Base-T (Full-Duplex) | 20
Mb/s | 100Base-TX (Half-Duplex) | 100
Mb/s | 100Base-TX (Full-Duplex) | 200
Mb/s | Connector | 10Base-T | Categories
3, 4 or 5 UTP; up to 328 ft (100 m) | Cable
Support | 100Base-TX | Category
5 UTP; up to 328 ft (100 m) |
|
|