DL QuickSpecs
|
DL20
|
|
DL60
|
|
DL80
|
|
DL120
|
|
DL140
|
|
DL145
|
|
DL160
|
|
DL160se
|
|
DL165
|
|
DL180
|
|
DL185
|
|
DL320
|
|
DL325
|
|
DL345
|
|
DL360
|
|
DL365
|
|
DL380
|
|
DL385
|
|
DL388
|
|
DL560
|
|
DL580
|
|
DL585
|
|
DL740
|
|
DL760
|
|
DL785
|
|
DL1000
|
|
|
ML QuickSpecs
|
ML30
|
|
ML110
|
|
ML115
|
|
ML150
|
|
ML310
|
|
ML330
|
|
ML350
|
|
ML370
|
|
ML530
|
|
ML570
|
|
ML750
|
|
|
BL QuickSpecs
|
BL10e
|
|
BL20p
|
|
BL25p
|
|
BL260c
|
|
BL280c
|
|
BL2x220c
|
|
BL30p
|
|
BL35p
|
|
BL40p
|
|
BL420c
|
|
BL45p
|
|
BL460c
|
|
BL465c
|
|
BL480c
|
|
BL495c
|
|
BL60p
|
|
BL620c
|
|
BL660c
|
|
BL680c
|
|
BL685c
|
|
BL860c
|
|
|
SL QuickSpecs
|
SL160z
|
|
SL165z
|
|
SL170s
|
|
SL170z
|
|
SL230s
|
|
SL250s
|
|
SL270s
|
|
SL2x170z
|
|
SL335s
|
|
SL390s
|
|
SL4540
|
|
SL4545
|
|
|
XL QuickSpecs
|
XL170r
|
|
XL190r
|
|
XL220a
|
|
XL230a
|
|
XL730f
|
|
XL740f
|
|
XL750f
|
|
|
CL QuickSpecs
|
CL1850
|
CL1850 G1
| |
CL380
|
CL380 G1
| |
|
|
|
|
|
|
|
Proliant ML330 G3 QuickSpecs |
US QuickSpecs |
|
|
|
|
|
|
|
|
|
Proliant ML330 G3 Overview
HP ProLiant ML330 Generation
3 (G3)
|
1. 48x IDE (ATAPI) CD-ROM |
2. Removable Media Bays (1.6" each) |
3. 1.44 MB Diskette Drive |
4. Two 1" Non-hot plug Hard Drive Bays | |
5. Four 64-bit/33MHz PCI | 6.
Processor socket 2 (unpopulated) | 7.
Processor 1 (populated) | 8.
System Fan | | |
|
What's New
- Supports up to 2 Intel® Xeon® 3.06 GHz or
2.8 GHz processors
|
At A Glance
- Two USB ports
- ROM Based Setup Utility (RBSU) and PXE support
- ServerWorks GC-SL Chipset with 533-MHz Front Side
Bus
- 512-KB second level ECC cache standard (full speed)
- 256-MB PC2100 ECC DDR SDRAM Memory, expandable to
4 GB
- Four total I/O slots; three available in SCSI models
- 64-Bit/33MHz, 3.3v PCI
- NC7760 PCI Gigabit Server Adapter (embedded)
- Integrated Dual Channel Ultra ATA/100 Adapter with
Integrated ATA RAID 0, 1, & 1+0 (ATA Models) or Integrated Single
Channel Wide Ultra3 SCSI Adapter in a PCI slot (SCSI Models)
- Support for up to five 1" Ultra320 non-hot-plug
SCSI hard drives or four 1" ATA non-hot-plug drives (model dependent)
- SCSI Models (with optional drive cage): Internal
storage capacity of up to 1.040 TB (3 x 146.8 GB non-hot-plug + 2 x
300 GB hot plug 1" hard drives)
- ATA Models: Internal storage capacity of up to 640
GB (4 x 160-GB ATA/100 drives)
- Integrated ATI Rage XL with 8MB SDRAM video
- 300W Power Supply
- Systems Insight Manager, SmartStart and Automatic
Server Recovery-2 (ASR-2)
- Protected by HP Services, including a one-year,
limited warranty, Next Business Day 1 year on-site limited Global warranty
and Pre-Failure Warranty, which covers processors, memory, and hard
drives - Certain restrictions and exclusions apply.
|
Standard Features
Processor
One of the following depending on
Model
|
Intel Xeon Processor 3.06 GHz/533-512KB
(Supports up to 2 processors) |
Intel Xeon Processor 2.8 GHz/533-512KB
(Supports up to 2 processors) |
|
Cache Memory |
Integrated 512-KB
Level 2 ECC cache (full speed) |
|
Memory Protection |
Advanced ECC capabilities |
|
ML330 G3 Memory
|
Type |
PC2100 DDR SDRAM running at
266MHz |
Standard |
256 MB (1 x 256 MB) |
Maximum |
4 GB |
|
Network Controller |
NC7760 PCI Gigabit
Server Adapter (embedded) |
|
Expansion Slots |
I/O |
Number of slots |
PCI Voltage: |
|
64-bit/33MHz PCI |
4 |
3.3 volts |
|
Storage Controller |
Integrated Single
Channel Wide Ultra3 SCSI Adapter in a PCI slot (SCSI
Models only) |
|
Integrated Dual
Channel Ultra ATA 100 IDE Adapter with Integrated ATA RAID 0, 1, & 1+0
(ATA Models) |
|
Storage |
Diskette Drives |
1.44 MB Diskette Drive |
Optical Drive |
48x IDE CD-ROM Drive |
Hard Drives |
One of the following: |
(1) 36.4 GB Ultra320 SCSI Drive
(SCSI Models only) |
(1) 40 GB ATA/100 7750 rpm 1"
Drive (ATA Models only) |
|
Maximum Internal
Storage |
SCSI (Non-Hot Plug and Hot Plug) |
1.04 TB |
3 x 146.8 GB non-hot-plug +
2 x 300 GB hot plug Ultra 320 with optional drive cage |
ATA |
640 GB |
4 x 160.0 GB ATA
(internal drive bays and removable media bays) |
|
Graphics |
Integrated ATI RAGE XL Video
Controller with 8MB SDRAM Video Memory |
|
Form Factor |
Tower (5U) Tower to Rack Enabling
Option Kit available (PN 238547-B22) |
|
ProLiant
Essentials Foundation Pack Software
|
HP Systems Insight Manager |
HP Systems Insight Manager
(HP SIM) helps maximize system uptime and performance and reduce system
maintenance costs by providing proactive notification of problems
before those problems result in unplanned downtime or reduced productivity.
For more information on HP SIM, visit https://www.hp.com/go/hpsim. |
|
SmartStart |
SmartStart simplifies
server setup by providing a rapid way to deploy reliable and consistent
server configurations. For more information, please visit the SmartStart
Web site at https://www.hp.com/servers/smartstart.
Minimum SmartStart version supported: SmartStart 6.4.
Latest SmartStart version supported: SmartStart 7.2 |
|
Management Agents |
The Management Agents
provide direct, browser-based access to in-depth instrumentation built
into HP servers, workstations, desktops, or portables, and send alerts
to Systems Insight Manager or other enterprise management applications
in case of subsystem or environmental failures. For additional information
about the Management Agents and other management products from HP,
visit https://www.hp.com/servers/manage. |
|
Subscriber's Choice |
Subscriber's Choice Driver
and Support Alerts/Notifications is a web-based email subscription
service that provides automatic delivery of software and driver change
notifications for ProLiant products. Sign up at https://www.hp.com/go/subscriberschoice
and customize your profile to receive alerts on updates as they become
available. |
|
ROMPaq,
support software, and
configuration utilities |
The latest software, drivers,
and firmware fully optimized and tested for your ProLiant server and
options
Available in SmartStart or downloadable from the Software and Drivers
download pages at https://www.hp.com/go/support. |
|
Survey Utility and diagnostics
utilities |
The most advanced configuration
analysis, reporting and troubleshooting utilities used by HP at your
fingertips
Available in SmartStart. |
|
Optional
ProLiant Essentials Value Packs |
Optional software offerings
that selectively extend the functionality of an Adaptive Infrastructure
to address specific business problems and needs:
- Rapid Deployment Pack – an automated solution for multi-server
deployment and provisioning, enabling companies to quickly and
easily adapt to changing business demands.
- Workload Management Pack provides easier management of
complex environments, improving overall server utilization and
enabling Windows® 2000 customers for the first time to confidently
deploy multiple applications on a single multiprocessor ProLiant
Server.
- Performance Management Pack a performance management
solution that identifies and explains hardware performance bottlenecks
on ProLiant servers and attached options enabling users to better
utilize their valuable resources.
- Intelligent Networking Pack - detects and analyzes network bottlenecks
or broken network linkages and steers traffic to the optimum route
based on network conditions.
- Vulnerability and Patch Management Pack - identifies and remediates
software security vulnerabilities due to missing patches as well
operating system configurations that can be exploited by viruses,
worms, and other blended threats
- Virtual Machine Management Pack - provides central management
and control of virtual machines from Microsoft and VMware. Integrated
approach provides the ability to manage both physical and virtual
resources from a single management console.
|
|
NOTE: Flexible
and volume quantity license kits are available for ProLiant Essentials Value
Packs. Refer to https://www.hp.com/servers/proliantessentials
or the various ProLiant Essentials Value Pack product QuickSpecs for more
information.
NOTE: For more information regarding ProLiant Essentials Software,
please see the following URL: https://www.hp.com/servers/proliantessentials
|
|
Industry Standard Compliance |
ACPI V1.0b Compliant
PCI 2.2 Compliant
PXE Support
WOL Support
Microsoft® Logo certifications |
|
Intelligent
Manageability |
HP Systems Insight Manager
Redundant ROM
Remote Flash ROM
Automatic Server Recovery-2 (ASR-2)
Remote Insight Lights-Out Edition II (optional)
Drive Parameter Tracking (with Smart Array Controller)
Dynamic Sector Repairing (with Smart Array Controller)
Pre-Failure Warranty (covers processors, memory and hard drives) |
|
Security |
Power-on password
Setup password
Diskette boot control
Power switch security |
|
Server Power Cords |
One Lowline power cord ships
standard |
|
Power Supply |
300 Watts, PFC (Power Factor
Correcting) |
|
System
Fans |
1 system fan ships standard.
1 system fan total supported (does not include fans integral to CPU heatsink
or power supply assemblies). |
|
Rack
Airflow Requirements |
Rack 10000 series Cabinets
The increasing power of new high-performance processor technology requires
increased cooling efficiency for rack-mounted servers. The 10000 Series
Racks provide enhanced airflow for maximum cooling, allowing these racks
to be fully loaded with servers using the latest processors.
CAUTION: If a third-party rack
is used, observe the following additional requirements to ensure adequate
airflow and to prevent damage to the equipment:
- Front and rear doors: If your 42U
server rack includes closing front and rear doors, you must allow
830 square inches (5,350 sq cm) of hole evenly distributed from top
to bottom to permit adequate airflow (equivalent to the required 64
percent open area for ventilation).
- Side: The clearance between the
installed rack component and the side panels of the rack must be a
minimum of 2.75 inches (7 cm).
CAUTION: Always use blanking panels
to fill all remaining empty front panel U-spaces in the rack. This arrangement
ensures proper airflow. Using a rack without blanking panels results in
improper cooling that can lead to thermal damage.
|
|
NOTE: For additional information, refer to the Setup and Installation Guide
or the Documentation CD provided with the server, or to the server documentation
located in the Support section at the following URL: https://h18000.www1.hp.com/products/servers/ProLiantml330/index.html. |
|
Factory Express Portfolio for
Servers and Storage |
HP Factory Express offers configuration,
customization, integration and deployment services for HP servers and storage
products. Customers can choose how their factory solutions are built, tested,
integrated, shipped and deployed.
Factory Express offers service packages for simple configuration, racking,
installation, complex configuration and design services as well as individual
factory services, such as image loading, asset tagging, and custom packaging.
HP products supported through Factory Express include a wide array of
servers and storage: HP Integrity, HP ProLiant, HP ProLiant Server Blades,
HP BladeSystem, HP 9000 servers as well as the MSA1000, VA7xxx, EVA3000
& EVA5000, XP, rackable tape libraries and configurable network switches.
For more information on Factory Express services for your specific server
model please contact your sales representative or go to https://www.hp.com/go/factory-express
|
|
Service and Support |
One-year limited warranty, including
hardware diagnostic support, and pre-failure warranty (coverage of hard
drives, memory and processors). The warranty is fully supported by HP Services
and a worldwide network of resellers and service providers. An additional
90-day getting started software telephone support may be covered under the
warranty or available for an additional fee. Enhancements to warranty services
are available through HP Care Pack services.
NOTE: Limited warranty includes 1
year parts, 1 year labor, 1-year on-site support.
Care Pack services provide a range of life cycle support options that
let you choose the service levels that meet your business requirements,
from basic to mission-critical.
A full range of HP Care Pack hardware and software services are available
including:
- Installation and start up
- Education courses
- Extended onsite hardware coverage hours from same business day 13
hours, 5 day to 24 hours, 7 days call window with options including
4-hour response or 6-hour Call To Repair
- Comprehensive range of software technical support for Microsoft,
Linux, ProLiant Essentials and VMWare-based IT solutions helping to
deliver high level of application availability. Response times range
from 30 mins for critical problems to 2 hours.
- System Management, Performance Services and Mission Critical Support
Solution
HP Care Pack services include coverage for the HP branded hardware options
qualified for the server, purchased at the same time or afterward, internal
to the enclosure, as well as 22" and smaller external monitors and
tower UPS options up to 3kVA; these items will be covered at the same
service level and for the same coverage period as the server. Coverage
of UPS Battery is not included, standard warranty terms & conditions
apply. For servers or storage systems installed within a rack, service
also covers all HP qualified rack options installed within the same rack.
|
NOTE: For more
information on HP Care Pack services, contact any of our worldwide sales
offices or resellers or visit our worldwide Web site on the internet at:
https://www.hp.com/hps/carepack
NOTE: For more complete information on HP Services offerings, customers
and resellers, please visit us at:https://www.hp.com/hps
NOTE: Additional information regarding worldwide limited warranty and
technical support is available at: https://h18004.www1.hp.com/products/servers/platforms/warranty/index.html |
Models
ML330T03 X3.06-512KB/533
256MB, 40GB, ATA
353448-002 |
Processor |
(1) Intel Xeon 3.06 GHz Processor
standard |
Cache Memory |
Integrated 512-KB Level 2 cache
(full speed) |
Memory |
256 MB |
Network Controller |
NC7760 PCI Gigabit Server Adapter
(embedded) |
Storage Controller |
Integrated Dual Channel Ultra
ATA-100 IDE Adapter with Integrated ATA RAID 0, 1, 1+0 |
Hard Drive |
40 GB Ultra ATA/100 |
Internal Storage |
640 GB maximum (with optional
hard drives) |
Optical Drive |
48x IDE (ATAPI) CD-ROM Drive |
Diskette Drive |
1.44 MB Diskette Drive |
Form Factor |
Tower (5U) (Tower to Rack Enabling
Kit available) |
|
ML330T03 X2.80-512KB/533
256MB, 40GB, ATA
317817-002 |
Processor |
(1) Intel Xeon 2.80 GHz Processor
standard |
Cache Memory |
Integrated 512-KB Level 2 cache
(full speed) |
Memory |
256 MB |
Network Controller |
NC7760 PCI Gigabit Server Adapter
(embedded) |
Storage Controller |
Integrated Dual Channel Ultra
ATA-100 IDE Adapter with Integrated ATA RAID 0, 1, 1+0 |
Hard Drive |
40 GB Ultra ATA/100 |
Internal Storage |
640 GB maximum (with optional
hard drives) |
Optical Drive |
48x IDE (ATAPI) CD-ROM Drive |
Diskette Drive |
1.44 MB Diskette Drive |
Form Factor |
Tower (5U) (Tower to Rack Enabling
Kit available) |
|
ML330T03 P3.06-512KB/533
256MB, 36GB, SCSI
353093-002 |
Processor |
(1) Intel Xeon 3.06 GHz Processor
standard |
Cache Memory |
Integrated 512-KB Level 2 cache
(full speed) |
Memory |
256 MB |
Network Controller |
NC7760 PCI Gigabit Server Adapter
(embedded) |
Storage Controller |
Integrated Single Channel Ultra3
SCSI Adapter in a PCI slot |
Hard Drive |
(1) 36.4 GB Ultra320 SCSI |
Internal Storage |
512 GB maximum (with optional
hot plug drive cage and optional hard drives) |
Optical Drive |
48x IDE (ATAPI) CD-ROM Drive |
Diskette Drive |
1.44 MB Diskette Drive |
Form Factor |
Tower (5U) (Tower to Rack Enabling
Kit available) |
|
ML330T03 P2.8-512KB/533
256MB, 36GB, SCSI
317821-002 |
Processor |
(1) Intel Xeon 2.8 GHz Processor
standard |
Cache Memory |
Integrated 512-KB Level 2 cache
(full speed) |
Memory |
256 MB |
Network Controller |
NC7760 PCI Gigabit Server Adapter
(embedded) |
Storage Controller |
Integrated Single Channel Ultra3
SCSI Adapter in a PCI slot |
Hard Drive |
(1) 36.4 GB Ultra320 SCSI |
Internal Storage |
402.8 GB maximum (with optional
hot plug drive cage and optional hard drives) |
Optical Drive |
48x IDE (ATAPI) CD-ROM Drive |
Diskette Drive |
1.44 MB Diskette Drive |
Form Factor |
Tower (5U) (Tower to Rack Enabling
Kit available) |
Options
ProLiant
Essentials
Value Pack Software |
Rapid Deployment
Pack, 1 User, V1.x
NOTE:
This license allows 1 server to be managed and deployed via the Deployment
Server. |
267196-B21
|
Rapid Deployment
Pack, 10 Users, V1.x
NOTE:
This license allows 10 servers to be managed and deployed via the Deployment
Server. |
269817-B21
|
Flexible Quantity
License Kit |
302127-B21
|
License-Only - for
use with a Master License Agreement |
302128-B21
|
ProLiant Essentials
Workload Management Pack 2.0 (Featuring Compaq Resource Partitioning Manager
version 2.0) |
|
ProLiant Essentials
Recovery Server Option Pack |
280189-B21
|
Performance Management
Pack, single server
NOTE: This license allows 1 server
to be managed by Performance Management Pack. |
306696-B21
|
Performance Management
Pack, 10 Pack Server License |
374055-B21
|
ProLiant Essentials
Performance Management Pack Flexible License
NOTE: A single pack is shipped with
a single license key for the total number of licenses ordered |
306697-B21
|
ProLiant Essentials
Intelligent Networking Pack, 1 License |
372906-B21
|
ProLiant Essentials
Intelligent Networking Pack Flex License |
372950-B21
|
ProLiant Essentials
Intelligent Networking Pack Track License |
372951-B21
|
ProLiant Essentials
Vulnerability and Patch Management Pack, Single-Server License |
371645-B21
|
ProLiant Essentials
Vulnerability and Patch Management Pack, 10-Server License |
377529-B21
|
ProLiant Essentials
Vulnerability and Patch Management Pack, Flexible-Quantity License |
371646-B21
|
ProLiant Essentials
Vulnerability and Patch Management Pack, Tracking license for new servers |
371647-B21
|
ProLiant Essentials
Vulnerability and Patch Management Pack, Tracking license for installed
servers |
378372-B21
|
ProLiant Essentials
Vulnerability and Patch Management Pack, 1-Server 10-Desktop Bundle License |
389941-B21
|
NOTE:
Flexible and volume quantity license kits are available for ProLiant
Essentials Value Packs. Refer to https://www.hp.com/servers/proliantessentials
or the various ProLiant Essentials Value Pack product QuickSpecs for
more information.
NOTE: For more information regarding ProLiant Essentials Software,
please see the following URL: https://www.hp.com/servers/proliantessentials. |
|
|
Software |
HP digital asset protection |
302316-001 |
|
Processors |
Intel Xeon 3.06 GHz-512KB
Processor Option Kit
NOTE: The Intel Xeon 3.06 GHz-512KB
Processor Option Kit is supported by the ProLiant ML330 G3 servers only.
|
354606-B21
|
Intel Xeon 2.80 GHz-512KB
Processor Option Kit
NOTE: The Intel Xeon 2.80 GHz-512KB
Processor Option Kit is supported by the ProLiant ML330 G3 servers only. |
317823-B21
|
Intel Xeon 2.40 GHz-512KB
Processor Option Kit
NOTE: The Intel Xeon 2.40 GHz-512KB
Processor Option Kit is supported by the ProLiant ML330 G3 servers only. |
323139-B21
|
ML330 G3 Memory (DIMMs)
|
128MB of Advanced ECC PC2100 DDR
SDRAM DIMM Memory Kit (1 x 128 MB) |
|
256MB of Advanced ECC PC2100 DDR
SDRAM DIMM Memory Kit (1 x 256 MB) |
|
512MB of Advanced ECC PC2100 DDR
SDRAM DIMM Memory Kit (1 x 512 MB) |
|
1024MB of Advanced ECC PC2100
DDR SDRAM DIMM Memory Kit (1 x 1024 MB) |
|
|
Optical Drives |
16X DVD-ROM Drive Option Kit (Carbon)
|
|
|
CD-RW/DVD ROM Combo Drive Option
Kit
NOTE: The DVD-ROM drive is supported
in the CD-ROM bay and in the removable media bay. If placed in the removable
media bay, it requires the 2-Device IDE cable (PN 305381-B21). |
|
HP DVD+R/RW 16X Half Height |
|
|
Internal Storage
|
ML3xx Two Bay Hot Plug SCSI Drive
Cage
NOTE: The drive cage option kit (PN
244059-B21) has one 1" drive bay and one 1.6" drive bay. It installs
in two removable media bays. |
|
|
Hard Drives |
Ultra320 SCSI Universal
Hot Plug |
|
NOTE: These Hot
Plug Drives are for use in conjunction with the ML3xx Two Bay Hot Plug SCSI
Drive Cage (PN 244059-B21). |
|
300-GB 10,000 rpm U320 Universal
Hard Drive (1") |
|
146.8-GB 10,000 rpm U320 Universal
Hard Drive (1") |
|
72.8-GB 10,000 rpm U320 Universal
Hard Drive (1") |
|
146.8-GB 15,000 rpm Ultra320 Universal
Hard Drive (1") |
|
72.8-GB 15,000 rpm U320 Universal
Hard Drive (1") |
|
36.4-GB 15,000 rpm U320 Universal
Hard Drive (1") |
|
Ultra320 SCSI Non-Hot
Plug |
|
146.8-GB 10,000 rpm, U320 Non-Hot
Plug Hard Drive, 1" |
|
72-GB 10,000 rpm, U320 Non-Hot
Plug Hard Drive, 1" |
|
36-GB 15,000 rpm, U320 Non-Hot
Plug Hard Drive, 1" |
|
NOTE: All U320
Universal Hard Drives are backward compatible to U2 or U3 speeds. U320 drives
require an optional U320 Smart Array Controller or U320 SCSI HBA to support
U320 transfer rates. |
|
ATA 100 - Non-Hot Plug |
|
160-GB ATA 100 7,200 rpm Hard
Drive (1") |
|
80-GB ATA 100 7,200 rpm Hard Drive
(1") |
|
40-GB ATA 100 7,200 rpm Hard Drive
(1") |
|
NOTE: Please see
the Hard Drive QuickSpecs for Technical Specifications such as capacity,
height, width, interface, transfer rate, seek time, physical configuration,
and operating temperature:
U320 Hard Drive QuickSpecs:
https://h18000.www1.hp.com/products/quickspecs/11531_na/11531_na.html
ATA100 Hard Drive QuickSpecs:
https://h18000.www1.hp.com/products/quickspecs/11361_na/11361_na.html
|
|
|
Storage Controllers
SCSI Drives |
NOTE: The following
Storage Controllers are qualified for SCSI drives only. |
|
Smart Array 6402/128 Controller |
|
Smart Array 641 Controller |
|
Smart Array 642 Controller |
|
Smart Array 6404/256 Controller
|
|
128MB Battery-Backed Cache Enabler
NOTE: This 128MB BBWC supports the
Smart Array 641 Controller and Smart Array 642 Controller.
|
|
128-MB Cache Module for Smart
Array 5302 Controller |
|
256-MB Battery-Back Cache Module
NOTE: This 256-MB Battery-Backed
Cache Module supports the Smart Array 5300 series controllers, HP StorageWorks
Modular Smart Array 1000 and the HP StorageWorks Modular Smart Array 500. |
|
256MB Battery-Backed Cache Upgrade
Kit for SA-6400
NOTE: This 256-MB Battery-Backed Cache upgrade kit supports the Smart
Array 6400 series controller only. |
|
64-Bit/133-MHz Dual Channel Ultra320
SCSI Adapter |
|
Ultra320 Expansion Module for
SA-6402 |
|
64-Bit/66-MHz Dual Channel Wide
Ultra3 SCSI Adapter, Alternate OS |
|
NOTE: Please see
the following Controller or SCSI Adapter QuickSpecs for Technical Specifications
such as PCI Bus, PCI Peak Data Transfer Rate, SCSI Protocols supported,
SCSI Peak Data Transfer Rate, Channels, SCSI Ports, Drives supported, Cache,
RAID support, and additional information:
https://h18000.www1.hp.com/products/quickspecs/11587_na/11587_na.html
(Smart Array 6400 Series)
https://h18000.www1.hp.com/products/quickspecs/12067_na/12067_na.html
(Smart Array 641)
https://h18000.www1.hp.com/products/quickspecs/12069_na/12069_na.html
(Smart Array 642)
https://h18000.www1.hp.com/products/quickspecs/10429_na/10429_na.html
(SCSI Adapter)
https://h18000.www1.hp.com/products/quickspecs/11555_na/11555_na.html
(U320 Adapter) |
|
|
Communications |
HP NC150T PCI 4-port Gigabit 1000T Combo Switch
Adapter |
|
HP NC310F PCI-X 1000SX Gigabit Server Adapter |
|
HP NC1020 PCI 1000T Gigabit Server Adapter |
|
NC6770 PCI-X Gigabit Server Adapter, 1000-SX |
|
HP NC7771 PCI-X 1000T Gigabit Server Adapter |
|
HP NC7170 PCI-X Dual Port 1000T Gigabit Server
Adapter |
|
NOTE: Any NC61XX, or NC71XX
NIC can be used for redundancy with the embedded NC7760 Network Controller. |
|
HP High-speed PCI soft modem |
DC132D
|
|
Management Options
|
Remote Insight Lights-Out Edition
II |
|
|
Tape Drives
|
NOTE: In
order to install certain tape drives internally, you may need to remove
the rails that come standard on the drives and then re-insert the
screws in the mounting holes. Mounting screws are shipped standard
with server. |
|
NOTE: To
run external SCSI-based devices, either an Internal-to-External SCSI
Cable Option kit (for SCSI models) or a SCSI controller with external
channel (for ATA models) must be purchased.
Review the server cabling matrix for additional information on cables
required to connect backup products to the server. |
|
Ultrium Tape Drives -
External, Rack-Mount and Array |
|
HP StorageWorks Ultrium
215 Tape Drive, External (Carbon) |
|
HP StorageWorks Ultrium
215 rack-mount (Carbon) - Single drive installed in a 1U rack-mount
kit |
A7444A
|
HP StorageWorks Ultrium
215 Array Module (Carbon) - Offline hot-swap drive for Tape Array
5300 |
|
HP StorageWorks Ultrium
230 Tape Drive, External (Carbon) |
|
HP StorageWorks Ultrium
230, Rack-mount (Carbon) - Single drive installed in a 3U rack-mount
kit |
|
HP StorageWorks Ultrium
230 Array Module (Carbon) - Offline hot-swap drive for Tape Array
5300 |
|
HP StorageWorks Ultrium
448 Tape Drive, External (Carbonite) |
DW017A
|
HP StorageWorks Ultrium
448, Rack-mount (Carbonite) - Single drive installed in a 1U rack-mount
kit |
DW028A
|
HP StorageWorks Ultrium
448 Tape Drive, Internal (Carbonite) |
DW016A
|
HP StorageWorks Ultrium
460 Tape Drive, External (Carbon) |
|
HP StorageWorks Ultrium
460, Rack-mount (Carbon) - Single drive installed in a 3U rack-mount
kit |
|
HP StorageWorks Ultrium
460 Array Module (Carbon) - Offline hot-swap drive for Tape Array
5300 |
|
HP StorageWorks Ultrium
960 Tape Drive, External (Carbonite) Q1539A |
|
HP StorageWorks Ultrium
960 Rack-mount (Carbonite) - Single drive installed in a 3U rack-mount
kit |
|
NOTE: Please see the HP StorageWorks Ultrium Tape Drive
QuickSpecs for additional options such as controllers, media, and
other related items:
https://h18006.www1.hp.com/products/quickspecs/11739_na/11739_na.html
https://h18006.www1.hp.com/products/quickspecs/12128_na/12128_na.html
|
|
For
an up-to-date listing of the latest O/S and software support details
for HP Ultrium tape drives, please visit: https://www.hp.com/go/connect |
|
DAT Drives - External,
Rack-Mount and Array Module
|
|
NOTE:
Use of a hot plug tape drives requires installation of the optional
two-bay SCSI drive cage.
|
|
HP StorageWorks DAT 72 Tape
Drive, External (Carbon) |
|
HP StorageWorks DAT 72 Tape
Drive, Internal (Carbon) |
|
HP StorageWorks DAT 72 Tape
Drive, Internal Hot-Plug (Carbon) |
|
HP StorageWorks DAT 72 Array
Module (Carbon) - Offline hot-swap drive for Tape Array 5300 |
|
HP StorageWorks DAT 40 Tape
Drive, External (Carbon) |
|
HP StorageWorks DAT 40 Tape
Drive, Internal (Carbon) |
|
HP StorageWorks DAT 40 Tape
Drive, Internal Hot-Plug (Carbon) |
|
HP StorageWorks DAT 40 Array
Module (Carbon) - Offline hot-swap drive for Tape Array 5300 |
|
NOTE:
Please see the DAT Tape Drive QuickSpecs for controllers, media,
and other options:
https://h18000.www1.hp.com/products/quickspecs/11883_na/11883_na.html
For an up-to-date listing of the latest O/S and software support details
for HP DAT drives, please visit: https://www.hp.com/go/connect
|
|
Internal and External
DLT VS Tape Drives
|
|
HP StorageWorks DLT VS80
Tape Drive, Internal (Carbon) |
|
HP StorageWorks DLT VS80
Tape Drive, External (Carbon) |
|
DLT VS160, Internal (Carbon) |
A7569A
|
DLT VS160, External (Carbon) |
A7570A
|
NOTE: Please
see the DLT VS Tape Drive QuickSpecs for additional options such as
host bus adapters, controllers, media, and other options:
https://h18006.www1.hp.com/products/quickspecs/11403_na/11403_na.html
For an up-to-date listing of the latest O/S and software support details
for the DLT VS80, please visit: https://www.hp.com/go/connect
|
|
External and Rack-mount
SDLT Tape Drives |
|
HP StorageWorks SDLT 320
Tape Drive, External (Carbon) |
|
NOTE:
Please see the SDLT 320 Tape Drive QuickSpecs for additional options
such as adapters, controllers, and media.
https://h18006.www1.hp.com/products/quickspecs/114840_na/11840_na.html
For an up-to-date listing of the latest O/S and software support details
for HP SDLT tape drives, please visit: https://www.hp.com/go/connect
|
|
Rack-Mount Tape Drive
Enclosures
|
|
HP StorageWorks 1U Rack-Mount
Kit
NOTE: The 1U Rack-mount Kit
can support up to 2 half-height tape drives and compatible with multiple
Single-Ended and LVD SCSI tape drives including DAT 24, DAT40, DAT72,
DLT VS 80, and Ultrium 215 tape drives.
|
|
HP StorageWorks 3U Rack-Mount
Kit
NOTE: The 3U Rack-Mount Kit
can support up to 2 full-height or 4 half-height tape drives and compatible
with multiple Single-Ended and LVD SCSI tape drives including DAT,
DLT VS80, SDLT 320, Ultrium 215, Ultrium 230, and Ultrium 460 Tape
Drives.
|
|
HP StorageWorks 5U Rack-Mount
Kit
NOTE: The 5U Rack-Mount Kit
can support up to 4 full-height tape drives and is compatible with
SDLT 320, Ultrium 230, and Ultrium 460 tape drives.
|
274339-B21
|
NOTE: Please
see the Rack-Mount Tape Drive Kits QuickSpecs for additional information
regarding these kits:
https://h18000.www1.hp.com/products/quickspecs/10854_na/10854_na.html
|
|
HP StorageWorks Tape Array
5300 |
|
NOTE:
The Tape Array 5300 is a 3U enclosure that supports up to 2 full-height
or 4 half-height hot-swap array modules, including DAT and Ultrium
tape drives. Cables and terminators are not included and must be ordered
separately.
NOTE: Please see the Tape Array 5300 QuickSpecs for additional
information regarding this product.
https://h18000.www1.hp.com/products/quickspecs/11878_na/11878_na.html
|
|
Accessories for 3U &
5U Rack-mount Tape Drive Kits
|
|
LVD Cable Kit, VHDCI/HD68
NOTE: For use with the 3U Rack-mount
Kit and 5U Rack-mount Kit only. |
|
LVD Cable Kit, HD68/HD68
NOTE: For use with the 3U Rack-mount
Kit and 5U Rack-mount Kit only.
|
|
Accessories for 3U &
5U Rack-mount Tape Drive Kits
|
|
PSU/Fan
Upgrade Kit - Redundant hot-swap power supply unit and fan for Tape
Array 5300.
|
|
68-pin HD multi-mode terminator |
|
1.0m 68-pin VHDCI to 68-pin
HD cable |
|
2.5m 68-pin VHDCI to 68-pin
HD cable |
|
5.0m 68-pin VHDCI to 68-pin
HD cable |
|
10.0m 68-pin VHDCI to 68-pin
HD cable |
|
0.5m 68-pin HDI to 68-pin
HD cable LVD/SE |
|
1.5m 68-pin HDI to 68-pin
HD cable LVD/SE |
C2979B
|
0.9m 68-pin HDI to 68-pin
HD cable LVD/SE |
C2911C
|
2.5m 68-pin HDI to 68-pin
HD cable LVD/SE |
C2924C
|
NOTE: For
use with Tape Array 5300 only |
|
|
|
Tape Autoloaders
|
DAT Autoloader
|
|
HP StorageWorks DAT 72x6 Internal
Autoloader |
Q1566A |
HP StorageWorks DAT 72x6 External
Autoloader |
Q1567A |
NOTE:
Please see the DAT Tape Autoloader QuickSpecs for additional options
such as host bus adapters, controllers and media:
https://h18000.www1.hp.com/products/quickspecs/11985_na/11985_na.html
|
|
HP StorageWorks 1/8 Tape Autoloader |
|
1/8 Ultrium 460 Tape Autoloader,
Tabletop |
AA927A |
1/8 SDLT 320 Tape Autoloader,
Tabletop |
AA926A |
1/8 Ultrium 230 Tape Autoloader,
Tabletop |
C9572CB |
1/8 DLT VS80 Tape Autoloader,
Tabletop |
C9264CB |
1/8 Tape Autoloader Rackmount
Kit |
C9268R |
NOTE: Required
to install the 1/8 tape autoloader in a standard 19-inch rack |
|
NOTE: Please reference
the 1/8 Tape Autoloader QuickSpecs at https://www.hp.com/go/automation
for additional information needed to create a complete solution; reference
current compatibility information at https://www.hp.com/go/ebs |
|
HP StorageWorks SSL1016 Tape
Autoloader |
|
SSL1016
Ultrium 460 Tape Autoloader |
330821-B21 |
SSL1016
SDLT 320 Tape Autoloader |
330816-B21 |
|
Tape Libraries
|
HP StorageWorks MSL6000
Tape Library |
|
Ultrium 960 technology |
|
MSL6030, 1 drive, 30 slots, Ultrium
960 |
AD606A |
MSL6030, 2 drive, 30 slots, Ultrium
960 |
AD607A |
MSL6030, 1 drive, 30 slots, Ultrium
960, with embedded FC router |
AD608A |
MSL6030, 2 drive, 30 slots, Ultrium
960, with embedded FC router |
AD609A |
MSL6060, 2 drive, 60 slots, Ultrium
960 |
AD610A |
MSL6060, 2 drive, 60 slots, Ultrium
960, with embedded FC router |
AD611A |
SDLT 600 technology |
|
MSL6026, 1 drive, 26 slots, SDLT
600 |
AD582A |
MSL6026, 2 drive, 26 slots, SDLT
600 |
AD583A |
MSL6026, 1 drive, 26 slots, SDLT
600, with embedded FC router |
AD584A |
MSL6026, 2 drive, 26 slots, SDLT
600, with embedded FC router |
AD585A |
MSL6052, 2 drive, 52 slots, SDLT
600 |
AD587A |
MSL6052, 2 drive, 52 slots, SDLT
600, with embedded FC router |
AD588A |
Ultrium 460 technology |
|
MSL6030, 1 drive, 30 slots, Ultrium
460 |
AD598A |
MSL6030, 2 drive, 30 slots, Ultrium
460 |
AD599A |
MSL6030, 1 drive, 30 slots, Ultrium
460, with embedded FC router |
AD600A |
MSL6030, 2 drive, 30 slots, Ultrium
460, with embedded FC router |
AD601A |
MSL6060, 2 drive, 60 slot Ultrium
460 |
AD603A |
MSL6060, 2 drive, 60 slot Ultrium
460, with embedded FC router |
AD604A |
NOTE: Please reference
the MSL6000 Tape Library QuickSpecs at https://www.hp.com/go/automation
for additional information needed to create a complete solution; reference
current compatibility information at https://www.hp.com/go/ebs |
|
HP StorageWorks MSL5026S2 Tape
Library
|
|
MSL5026S2, 1 drive, 26 slots,
SDLT 320, RM |
293472-B22 |
MSL5026S2, 2 drive, 26 slots,
SDLT 320, RM |
293472-B23 |
MSL5026S2, 1 drive, 26 slots,
SDLT 320, RM with embedded FC router |
293472-B24 |
MSL5026S2, 2 drive, 26 slots,
SDLT 320, RM with embedded FC router |
293472-B25 |
HP StorageWorks MSL5026S2 Tape
Library
|
|
MSL5026S2, 1 drive, 26 slots,
SDLT 320, RM |
293472-B22 |
MSL5026S2, 2 drive, 26 slots,
SDLT 320, RM |
293472-B23 |
MSL5026S2, 1 drive, 26 slots,
SDLT 320, RM with embedded FC router |
293472-B24 |
MSL5026S2, 2 drive, 26 slots,
SDLT 320, RM with embedded FC router |
293472-B25 |
NOTE: Please reference
the MSL5026S2 Tape Library QuickSpecs at https://www.hp.com/go/automation
for additional information needed to create a complete solution; reference
current compatibility information at http:/www.hp.com/go/ebs |
|
HP StorageWorks MSL5052S2 Tape
Library |
|
MSL5052S2, 2 drive, 52 slots,
SDLT 320, RM |
293474-B21 |
MSL5052S2, 2 drive, 52 slots,
SDLT 320, RM with embedded FC router |
293474-B24 |
NOTE:
Please reference the MSL5052S2
Tape Library QuickSpecs at https://www.hp.com/go/automation
for additional information needed to create a complete solution; reference
current compatibility information at http:/www.hp.com/go/ebs |
|
HP StorageWorks MSL5030 Tape
Library
|
|
MSL5030, 1 drive, 30 slots, Ultrium
230, RM |
301897-B22 |
MSL5030, 2 drive, 30 slots, Ultrium
230, RM |
301897-B23 |
MSL5030, 1 drive, 30 slots, Ultrium
230, RM with embedded FC router |
301897-B24 |
MSL5030, 2 drive, 30 slots, Ultrium
230, RM with embedded FC router |
301897-B25 |
NOTE:
Please reference the MSL5030
Tape Library QuickSpecs at https://www.hp.com/go/automation
for additional information needed to create a complete solution; reference
current compatibility information at http:/www.hp.com/go/ebs |
|
HP StorageWorks MSL5060 Tape
Library
|
|
MSL5060, 2 drive, 60 slots, Ultrium
230, RM |
301899-B22 |
MSL5060, 2 drive, 60 slots, Ultrium
230, RM with embedded FC router |
301899-B23 |
NOTE:
Please reference the MSL5060
Tape Library QuickSpecs at https://www.hp.com/go/automation
for additional information needed to create a complete solution; reference
current compatibility information at http:/www.hp.com/go/ebs |
|
HP StorageWorks ESL E-Series
Tape Libraries |
|
ESL Extended 712e Tape Library,
0 drive, 712 LTO slots |
AA934B |
ESL Extended 630e Tape Library,
0 drive, 630 SDLT slots |
AA935B |
ESL Extended 322e Tape Library,
0 drive, 322 LTO slots |
AA939B |
ESL Extended 286e Tape Library,
0 drive, 286 SDLT slots |
AA940B |
ESL E-Series Ultrium 960 drive
kit |
AD595A |
ESL E Ultrium 460 drive kit |
AA937A |
ESL E SDLT 320 drive kit |
AA936A |
NOTE: Please reference
the ESL E-Series Tape Libraries QuickSpecs at https://www.hp.com/go/automation
for additional information needed to create a complete solution; reference
current compatibility information at https://www.hp.com/go/ebs |
|
|
Magneto-Optical Jukeboxes
|
HP StorageWorks 9.1 GB Entry-level
Optical Storage
|
|
9100mx standalone drive |
C1114M |
220mx, 1 drive, 24 slot jukebox |
C1118M |
220mx, 2 drive, 24 slot jukebox |
C1119M |
NOTE: Please reference the
Magneto-Optical Jukebox data sheets at https://www.hp.com/go/optical
for additional information needed to create a complete solution |
|
|
Ultra Density Optical Jukeboxes |
HP StorageWorks Ultra Density Optical Storage |
|
30ux standalone drive |
AA961A |
700ux, 1 drive, 24 slot jukebox |
AA962A |
700ux, 2 drive, 24 slot jukebox |
AA963A |
1100ux, 2 drive, 38 slot jukebox |
AA964A |
NOTE: Please reference the
Magneto-Optical Jukebox data sheets at https://www.hp.com/go/optical
for additional information needed to create a complete solution |
|
|
HP StorageWorks Modular Smart Array 500
|
HP StorageWorks Modular Smart Array 500 Generation 2
|
335880-B21
|
Modular Smart Array 500 High Availability
Kit
NOTE: includes Modular Smart Array
500 controller, 4-port IO Module, Smart Array Multipath Software and 2 SA-532
Adapters.
|
351281-B21
|
Modular Smart Array 500 Controller
|
218252-B21
|
128-MB Cache Module for Smart Array Controller
|
|
NOTE: 128-MB Cache Module for Smart
Array Controller (PN 153506-B21) is an upgrade cache module (128 MB Standard)
for Modular Smart Array 500 Controller
|
|
256-MB Battery-Backed Cache Module
|
|
NOTE:
Please see the Modular Smart Array 500 QuickSpecs for additional information
including configuration steps and additional options needed for a complete
solution at:
https://h18000.www1.hp.com/products/quickspecs/11050_na/11050_na.html
|
|
|
External Storage
Tower & Rack |
NOTE: To run any
external SCSI-based devices, the customer needs to purchase an Internal
to External Cable Option kit for SCSI models or a SCSI controller for ATA
Models. |
|
HP StorageWorks Modular Smart
Array 30 SB
NOTE: Rack-mountable 14 drive enclosure
with single bus, redundant power supplies |
302969-B21
|
HP StorageWorks Modular Smart
Array 30 DB
NOTE: Rack-mountable 14 drive enclosure
with dual bus, redundant power supplies |
302970-B21
|
NOTE:
The Modular Smart Array Enclosure 30 Family supports the Wide Ultra3, Ultra320
1" Hot Plug Hard Drives. |
|
StorageWorks Enclosure 4200 Redundant
Power Supply Option |
|
StorageWorks Enclosure 4200 Ultra3
Single Bus I/O Module Option
|
|
StorageWorks Enclosure 4200 Ultra3
Dual Bus I/O Module Option
|
|
Redundant Power Supply 499W |
|
StorageWorks Single Bus U320 I/O
Module for MSA30
|
287484-B21
|
StorageWorks Dual Bus U320 I/O
Module for MSA30 |
287483-B21
|
Uninterruptible Power Supply
|
HP T500 UPS, 120 V (US) |
361475-001
|
HP T750 UPS |
378439-D71
|
HP UPS Model T700 (700VA, 500
Watt), Low Voltage |
204015-001
|
HP UPS Model T1000 XR (1000VA,
700 Watt), Low Voltage |
204155-001
|
HP UPS Model T1500 XR (1440VA,
1050 Watt), Low Voltage |
|
|
Uninterruptible Power Systems Rack
|
HP UPS R5500 XR, (5000VA, 4500
Watt), High Voltage |
326529-D71 |
HP UPS R1500 XR (100 to 127) |
|
HP UPS R3000 XR (120V) |
|
HP UPS R3000 XR (208V) |
|
UPS R12000 XR N+ x (200-240V)
(hardwired) |
207552-B22
|
NOTE:
UPS R12000 XR has a hardwired input and output connection. |
|
HP Power Distribution Unit with Power Monitoring
|
HP Power Distribution Unit with
Power Monitoring Model S2324 - dual input, 3 phase, 24A |
|
HP Power Distribution Unit with
Power Monitoring Model S1324 - single input, 3 phase, 24A |
|
HP Power Distribution Unit with
Power Monitoring Model S2140 - dual input, 1 phase, 40A |
|
HP Power Distribution Unit with
Power Monitoring Model S1140 - single input, 1 phase, 40A |
|
|
Modular PDUs 1U/0U (up to 32 outlets)
NOTE: 1U/0U mounting brackets shipped
with the unit (optimized for 10000
and 9000 series racks).
|
HP Modular Power Distribution
Units (mPDU), Low Volt Model, 24A (100-127 VAC)
NOTE: The above mPDU may also be
used to connect to the low volt model of the UPS R3000 XR. |
|
HP Modular Power Distribution
Units (mPDU), High Volt Model, 24A (200-240 VAC)
NOTE:
L6-30 input. |
|
HP Modular Power Distribution
Unit (mPDU), High Volt Model, 40A, Attached Cord |
252663-D73
|
NOTE: Please see
the following Modular Power Distribution Unit (Zero-U/1U Modular PDUs) QuickSpecs
for additional options including shorter jumper cables and country specific
power cords:
https://h18000.www1.hp.com/products/quickspecs/11041_na/11041_na.html |
|
|
USB
Options |
USB Optical Scroll Mouse (Carbonite) |
DD441B
|
USB 1.44-MB External Diskette
Drive (Carbonite) |
DC141B
|
|
Rack Enabling Kit
|
ProLiant ML310/ML330 Rack Enabling
Kit |
238547-B22
|
DL360 G2/G3 Telco Rack Option
Kit |
251243-B21
|
|
NOTE: The DL360
Telco Rack Option Kit (251243-B21) interfaces with the ProLiant ML310/ML330
Rack Enabling Kit (PN 238547-B22) to support installation in a telco rack. |
|
|
Other
|
ProLiant ML310/ML330 G2 SCSI Cable
Kit
NOTE: This SCSI Cable Kit (PN 273463-B21)
is required when installing an internal tape drive and a SCSI Controller. |
273463-B21
|
ProLiant ML3xx Internal to External
SCSI Cable Option Kit (HD68) |
159547-B22
|
ProLiant ML3xx Internal to External
SCSI Cable Option Kit (VHDCI) |
333370-B21
|
|
HP Rack 5000 Series (Graphite
Metallic) |
HP 5642 Rack-Unassembled |
|
|
Rack Options for Rack
5000 Series |
Stabilizer Kit for 5642 rack (Graphite
Carbon)
NOTE: The stabilizing kit is used
to prevent rack from tipping over.
|
374493-B21
|
Baying Kit for 5642 rack (Graphite
Carbon)
NOTE: The baying kit is used to join
two or more HP 5642 racks.
|
374499-B21
|
|
HP Rack 10000 Series
(Graphite Metallic)
|
10642 (42U) Infrastructure Rack
(Low Voltage) |
379006-001
|
10642 (42U) Infrastructure Rack
(High Voltage) |
|
HP Rack S10614 (14U) Rack Cabinet
Shock Pallet |
|
HP Rack 10842 (42U, 800mm wide) – Pallet
|
257415-B21
|
HP Rack 10842 (42U, 800mm wide) – Shock Pallet
|
257415-B22
|
HP Rack 10647 (47U) – Pallet
|
245160-B21
|
HP Rack 10647 (47U) – Crated
|
245160-B23
|
HP Rack 10642 (42U) – Pallet
|
245161-B21
|
HP Rack 10642 (42U) – Shock Pallet
|
245161-B22
|
HP Rack 10642 (42U) – Crated
|
245161-B23
|
HP Rack 10636 (36U) – Pallet
|
245162-B21
|
HP Rack 10636 (36U) – Shock Pallet
|
245162-B22
|
HP Rack 10636 (36U) – Crated
|
245162-B23
|
HP Rack 10622 (22U) – Pallet
|
245163-B21
|
HP Rack 10622 (22U) – Shock Pallet
|
245163-B22
|
HP Rack 10622 (22U) – Crated
|
245163-B23
|
HP Rack 10614 (14U) – Shock Pallet
|
292303-B22
|
NOTE: -B21 (pallet) used to ship empty
racks shipped on a truck
-B22 (shock pallet) used to ship racks with equipment installed (by custom
systems, VARs and Channels)
-B23 (crated) used for air shipments of empty racks
|
|
NOTE: It is mandatory to use a shock
pallet in order to ship racks with equipment installed. Not all HP equipment
is qualified to be shipped in the Rack 10000 series
|
|
NOTE: Please see the Rack 10000 QuickSpecs
for Technical Specifications such as height, width, depth, weight, and
color:
https://h18000.www1.hp.com/products/quickspecs/10995_na/10995_na.html
|
|
NOTE: For additional information regarding
Rack Cabinets, please see the following URL: https://h18000.www1.hp.com/products/servers/proliantstorage/rack-options/index.html.
|
|
|
Rack Options for HP
Rack 10000 Series |
NOTE: For additional
information regarding Rack Options, please see the following URL: https://h18000.www1.hp.com/products/servers/proliantstorage/rack-options/index.html. |
|
HP Rack Light Kit (Neon) |
|
HP Rack Plinth Kit (Carbon) |
|
42U Side Panel – Graphite Metallic
|
246099-B21
|
36U Side Panel – Graphite Metallic
|
246102-B21
|
47U Side Panel – Graphite Metallic
|
255486-B21
|
TFT5600 Rack Keyboard Monitor
|
221546-001
|
1U Rack Keyboard & Drawer
(Carbon) |
|
NOTE: For additional
information regarding Rack Options, please see the following URL: https://h18000.www1.hp.com/products/servers/proliantstorage/rack-options/index.html. |
|
|
HP KVM Switch Options |
Server Console Switch (KVM), 0
x 1 x 8 port |
|
Server Console Switch (KVM), 0
x 2 x 16 port |
|
IP Console Switch Box (KVM/IP),
1 x 1 x 16 |
|
IP Console Switch Box (KVM/IP),
3 x 1 x 16 |
|
HP 1x4 USB/PS2 KVM Switch, TT |
371301-D71
|
PS/2 Interface Adapter, 8 pack |
|
PS/2 Interface Adapter, 1 pack |
|
CAT5 KVM Expansion Module |
|
Serial Interface adapter - 1 Pack
with power supply |
|
CAT5e Cable 3', 4 pack |
|
CAT5e Cable 6', 8 pack |
|
CAT5e Cable 12', 8 pack |
|
CAT5e Cable 20', 4 pack |
|
CAT5e Cable 40', 1 pack |
|
NOTE: For additional
information regarding HP KVM Switches and options, please see the following
URL:
https://h18004.www1.hp.com/products/servers/proliantstorage/rack-options/list.html#console
|
|
|
Service and Support Offerings (HP
Care Pack Services)
|
Hardware Services
On-site Service |
|
Next Business Day On-site
Service, 5-Day x 9-Hour Coverage, 3 Years |
U4462A
|
Next Business Day On-site
Service, 5-Day x 9-Hour Coverage, 3 Years, Electronic |
U4462E
|
4-Hour On-site Service,
5-Day x 13-Hour Coverage, 3 Years |
U4463A
|
4-Hour On-site Service,
5-Day x 13-Hour Coverage, 3 Years, Electronic |
U4463E
|
4-Hour On-site Service,
7-Day x 24-Hour Coverage, 3 Years |
U4464A
|
4-Hour On-site Service,
7-Day x 24-Hour Coverage, 3 Years, Electronic |
U4464E
|
6-Hour Call to Repair, On-site
Service, 7-Day x 24-Hour Coverage, 3 Years |
U4465A
|
6-Hour Call to Repair, On-site
Service, 7-Day x 24-Hour Coverage, 3 Years, Electronic |
U4465E
|
|
Installation &
Start-up Services |
|
Hardware Installation |
U4473A
|
Hardware Installation, Electronic |
U4473E
|
Installation & Start-Up
of a ProLiant server and Microsoft or Linux O/S per the Customer Description
and/or Data Sheet. To be delivered on a scheduled basis 8am-5pm, M-F,
excl. HP holidays. |
U4474A
|
Installation & Start-Up
of a ProLiant server and Microsoft or Linux O/S per the Customer Description
and/or Data Sheet. To be delivered on a scheduled basis 8am-5pm, M-F,
excl. HP holidays, Electronic |
U4474E
|
|
Support Plus |
|
Onsite HW support, 8am-9pm,
M-F, 4hr response and Microsoft O/S SW Tech support offsite, onsite
at HP's discretion, 8am-9pm, M-F 2hr response time excl. HP holidays. |
U4475A
|
Onsite HW support, 8am-9pm,
M-F, 4hr response and Microsoft O/S SW Tech support offsite, onsite
at HP's discretion, 8am-9pm, M-F 2hr response time excl. HP holidays,
Electronic |
U4475E
|
Onsite HW support, 8am-9pm,
M-F, 4hr response and Linux O/S SW Tech support offsite, onsite at
HP's discretion, 8am-9pm, M-F 2hr response time excl. HP holidays. |
U4477A
|
Onsite HW support, 8am-9pm,
M-F, 4hr response and Linux O/S SW Tech support offsite, onsite at
HP's discretion, 8am-9pm, M-F 2hr response time excl. HP holidays,
Electcronic |
U4477E
|
|
Support Plus 24 |
|
Onsite HW support 24x7,
4hr response and Microsoft O/S SW Tech support offsite, onsite at
HP's discretion, 24x7 2hr response time incl. HP holidays. |
U4476A
|
Onsite HW support 24x7,
4hr response and Microsoft O/S SW Tech support offsite, onsite at
HP's discretion, 24x7 2hr response time incl. HP holidays, Electronic |
U4476E
|
Onsite HW support 24x7,
4hr response and Linux O/S SW Tech support offsite, onsite at HP's
discretion, 24x7 2hr response time incl. HP holidays. |
U4478A
|
Onsite HW support 24x7,
4hr response and Linux O/S SW Tech support offsite, onsite at HP's
discretion, 24x7 2hr response time incl. HP holidays, Electronic |
U4478E
|
|
|
Memory
HP ProLiant ML330 G3 Models
|
Standard Memory
256-MB (expandable to 4GB) of non-interleaved PC2100 DDR SDRAM running
at 266MHz, with Advanced ECC capabilities (1 x 256MB)
Standard Memory Plus Optional Memory
Up to 3328-MB memory is available with the optional installation of PC2100
DDR SDRAM memory kits.
Standard Memory Replaced with
Optional Memory
Up to 4096-MB memory is available with the removal of the standard 256-MB
of memory and the optional installation of PC2100 DDR SDRAM DIMM memory
kits.
NOTE: Charts do not represent all
possible memory configurations.
|
ML330 G3 Memory
|
Slot
|
|
1
|
2
|
3
|
4
|
Standard
|
256 MB
|
256 MB
|
Empty
|
Empty
|
Empty
|
Optional
|
3,328 MB
|
256 MB
|
1024 MB
|
1024 MB
|
1024 MB
|
Maximum
|
4,096 MB
|
1024 MB
|
1024 MB
|
1024 MB
|
1024 MB
|
Following are memory options available from HP:
|
|
- 128MB of Advanced ECC PC2100 DDR SDRAM DIMM Memory Kit (1 x 128 MB)
|
|
- 256MB of Advanced ECC PC2100 DDR SDRAM DIMM Memory Kit (1 x 256 MB)
|
|
- 512MB of Advanced ECC PC2100 DDR SDRAM DIMM Memory Kit (1 x 512 MB)
|
|
- 1024MB of Advanced ECC PC2100 DDR SDRAM DIMM Memory Kit (1 x 1024
MB)
|
|
|
Storage

| A | 48x
IDE (ATAPI) CD-ROM | E |
1.44 MB Diskette Drive |
B,
C, D | Removable Media Bays (1.6"
each) | 0,1 | Two
1" Non-Hot Plug Drive Bays | | |
|
Drive Support
|
|
|
Quantity
Supported
|
Position
Supported
|
Controller
|
Removable Media
|
|
|
|
1.44-MB Diskette Drive |
Up to 1 |
E |
Integrated |
IDE (ATAPI) CD-ROM Drive |
Up to 2 |
A, B, C, or D |
Integrated IDE (ATAPI) |
DVD-ROM Drive Option Kit |
Up to 2 |
A, B, C, or D |
Integrated IDE (ATAPI) |
|
Hard Drives
|
|
Hard Drives
(SCSI Models only) |
|
Ultra320 Hot Pluggable Drives
(NOTE: For use with the ML3xx Two Bay Hot Plug SCSI Drive Cage PN
244059-B21 ONLY.) |
|
Quantity
Supported
|
Position
Supported
|
Controller
|
|
1-inch
300-GB 10,000 rpm
146.8-GB 10,000 rpm
72.8-GB 10,000 rpm
146.8-GB 15,000 rpm
72.8-GB 15,000 rpm
36.4-GB 15,000 rpm
|
Up to 2
(With optional ML3xx Two Bay Hot Plug SCSI
Drive Cage) |
A & B |
Integrated Single Channel Wide
Ultra3 SCSI Adapter in a PCI slot
Smart Array 6402/128 Controller
Smart Array 6404/256 Controller
Smart Array 641 Controller
Smart Array 642 Controller
64-Bit/133-MHz Dual Channel Ultra320 SCSI Adapter |
|
Ultra320 Non-Hot Plug |
|
1-inch
146.8-GB 10,000 rpm
72-GB 10,000 rpm
36.4-GB 15,000 rpm
|
Up to 5 |
0, 1, A, B, C, D
(Using the A position requires the removal or re-positioning of CD-ROM) |
Integrated Single Channel Wide
Ultra3 SCSI Adapter in a PCI slot
Smart Array 6402/128 Controller
Smart Array 6404/256 Controller
Smart Array 641 Controller
Smart Array 642 Controller
64-Bit/133-MHz Dual Channel Ultra320 SCSI Adapter |
|
NOTE: All U320
Universal Hard Drives are backward compatible to U2 or U3 speeds. U320 drives
require an optional U320 Smart Array Controller or U320 SCSI HBA to support
U320 transfer rates. |
|
|
|
Hard
Drives (ATA Models only) |
|
ATA/100 - Non-Hot Plug |
|
1-inch
160.0-GB
80.0-GB
40.0-GB
|
Up to 4 |
0, 1, A, B, C, D
(Using the A position requires the removal or re-positioning of CD-ROM)
|
Integrated Dual Channel Ultra
ATA-100 Adapter with support for Integrated ATA RAID 0, 1, & 1+0 (ATA
Models) |
|
External Storage |
| Quantity Supported |
Position Supported |
Host Controller or Adapter
|
| Modular
Smart Array 30 Family |
Up to 13 | External |
Smart Array 6402/128 Controller
Smart Array 6404/256 Controller
Smart Array 642 Controller
64-Bit/133-MHz Dual Channel Ultra320 SCSI Adapter
64-Bit/66-MHz Dual Channel Wide Ultra3 SCSI Adapter, Alternate OS
|
|
Modular Smart Array 500 G2 System
|
1 | External |
Please see the Modular Smart Array
500 QuickSpecs for the latest list of supported HBAs: : https://www.hp.com/go/msa500
|
| Modular
Smart Array 1000 | Please
see the Modular Smart Array 1000 QuickSpecs below to determine configuration requirements | External | Please
see the Modular Smart Array 1000 QuickSpecs (URL below) for the latest list of
supported HBAs | | Modular
Smart Array 1000: https://h18000.www1.hp.com/products/quickspecs/11033_na/11033_na.html |
|
Maximum Storage Capacity - ATA
Models (SCSI Enclosure)
|
Internal
|
640.0 GB (4 x 160.0
GB) (ATA only) |
External |
29.400 TB (14 x 300
GB) x 7 (Requires additional SCSI controllers in slots) |
Total |
30.040 TB |
Maximum Storage Capacity -
SCSI Models (SCSI Enclosure) + Optional Hot Plug Drive Cage) |
Internal |
1040.4 GB ((3 x 146.8
GB non-hot-plug hard drives) + (2 x 300 GB hot plug hard drives)) |
External |
29.400 TB (14 x 300
GB) x 7 (Requires additional SCSI controller in slots) |
Total |
30.218 TB |
|
Tape Drives, Tape Autoloaders
& Tape Libraries |
NOTE:
For an up-to-date listing of the latest O/S Support details for each of
the Tape Drives listed below, please see the following:
https://h18000.www1.hp.com/products/quickspecs/north_america/10233.html
NOTE: For an up-to-date listing of the
latest O/S Support details for each of the Tape Autoloaders and Tape Libraries
listed below, please see the following:
https://h18000.www1.hp.com/products/quickspecs/north_america/10809.html
NOTE: For complete listing of tape drive
offerings see https://www.hp.com/products1/storage/compatibility/tapebackup/ISS/index.html
|
|
Quantity |
Position Supported |
Controller
|
HP StorageWorks Tape Drives,
Internal, Hot Plug
DAT 72 Tape Drive
DAT 40 Tape Drive
(NOTE: For use with the ML3xx Two Bay Hot Plug SCSI Drive Cage (PN
244059-B21) ONLY.) |
Up to 2
(With optional ML3xx Two Bay Hot Plug SCSI Drive Cage) |
A & B |
Smart Array 5i Controller (integrated
on system board)
Smart Array 6402/128 Controller
Smart Array 6404/256 Controller
Smart Array 642 Controller
Smart Array 641 Controller
64-Bit/133-MHz Dual Channel Ultra320 SCSI Adapter
64-Bit/66-MHz Dual Channel Wide Ultra3 SCSI Adapter, Alternate OS |
|
|
|
|
HP StorageWorks Tape Drives, Internal
DAT 72 Tape Drive
DAT 40 Tape Drive
DAT 24 Tape Drive
DLT VS80 Tape Drive
DLT VS160 Tape Drive
SDLT 320 Tape Drive
|
Up to 2 |
B, C, D |
64-Bit/133MHz Dual Channel Ultra320
SCSI Adapter
64-Bit/66-MHz Dual Channel Wide Ultra3 SCSI Adapter, Alternate OS |
|
|
|
|
HP StorageWorks Tape Drives,
External
Ultrium 215
Ultrium 230
Ultrium 448
Ultrium 460
DAT 72 Tape Drive
DAT 40 Tape Drive
DAT 24 Tape Drive
DLT VS80 Tape Drive
DLT VS160 Tape Drive
SDLT 320 Tape Drive |
Up to 2 |
External |
64-Bit/133MHz Dual Channel Ultra320
SCSI Adapter
64-Bit/66-MHz Dual Channel Wide Ultra3 SCSI Adapter, Alternate OS |
|
|
|
|
HP StorageWorks Tape Drives,
External
Ultrium 960
|
1 |
External |
64-Bit/133MHz Dual Channel Ultra320
SCSI Adapter
64-Bit/66-MHz Dual Channel Wide Ultra3 SCSI Adapter, Alternate OS |
|
|
|
|
HP StorageWorks Autoloaders,
External
DAT 72x6 Tape Autoloader
1/8 Tape Autoloader
SSL1016 Tape Autoloader |
1 autoloader per SCSI channel
|
External |
64-Bit/133MHz Dual Channel Ultra320
SCSI Adapter
64-Bit/66-MHz Dual Channel Wide Ultra3 SCSI Adapter, Alternate OS
|
|
|
|
|
HP StorageWorks Tape Libraries,
External
MSL6000 (Ultrium 960-based)
MSL6000 (SDLT 600-based)
MSL6000 (Ultrium 460-based)
MSL5026S2 (SDLT 320-based)
MSL5052S2 (SDLT 320-based)
|
Please reference the
MSL Tape Library QuickSpecs to determine configuration requirements |
External |
64-Bit/133MHz Dual Channel Ultra320
SCSI Adapter
64-Bit/66-MHz Dual Channel Wide Ultra3 SCSI Adapter, Alternate OS |
|
|
|
|
HP StorageWorks Rack-mount
Tape Drive Enclosures
1U Rack-Mount Kit
3U Rack-Mount Kit
5U Rack-Mount Kit
|
1 per SCSI channel |
External |
64-Bit/133MHz Dual Channel Ultra320
SCSI Adapter
64-Bit/66-MHz Dual Channel Wide Ultra3 SCSI Adapter, Alternate OS
|
|
|
|
|
HP StorageWorks ESL E-Series
Tape Libraries
ESL 712e
ESL 630e
ESL 322e
ESL 286
|
Please reference the
ESL E-series Tape Libraries QuickSpecs to determine configuration requirements |
External |
64-Bit/133MHz Dual Channel Ultra320
SCSI Adapter
64-Bit/66-MHz Dual Channel Wide Ultra3 SCSI Adapter, Alternate OS
|
Power Specifications
Part
Number | 319640-001 |
Spare Kit | 324714-001 |
Operational Input Voltage Range
(Vrms) | 90-264 | Frequency
Range (Nominal) (Hz) | 47 - 63 (50
/ 60) | |
|
Nominal
Input Voltage (Vrms) | 100 |
115 | 208 |
220 | 230 |
240 | Max
Rated Output Wattage Rating | 300 |
300 | 300 |
300 | 300 |
300 | Nominal
Input Current (Arms) | 4.6 |
3.9 | 2.1 |
2.0 | 1.9 |
1.8 | Max
Rated Input Wattage Rating (Watts) | 435 |
429 | 423 |
423 | 417 |
411 | Max.
Rated VA (Volt-Amp) | 458 |
451 | 445 |
445 | 439 |
433 |
Efficiency (%) | 69 |
70 | 71 |
71 | 72 |
73 |
Power Factor | 0.95 |
Leakage Current (mA) |
0.70 | 0.81 |
1.47 | 1.55 |
1.62 | 1.69 |
Maximum Inrush Current
(A peak) | 42 |
48 | 81 |
92 | 96 |
100 |
Maximum Inrush Current duration (mS) |
2 |
|
Processor |
ML330 G3 Memory | HDD |
PCI | PS |
|
HP ProLiant ML330 G3 Fully Configured |
2 |
4 | 5 |
4 | 1 | |
Fully Loaded System Input Wattage
(W) | 425 |
419 | 413 |
413 | 408 |
402 | Fully
Loaded System Input Current (Arms) | 4.5 |
3.8 | 2.1 |
2.0 | 1.9 |
1.8 | Fully
Loaded System Thermal (BTU-Hr) | 1450 |
1429 | 1409 |
1409 | 1390 |
1371 | Fully
Loaded System VA (Volt-Amp) | 448 |
441 | 435 |
435 | 429 |
423 | System
Leakage with all power supplies loaded (mA) |
0.70 | 0.81 |
1.47 | 1.55 |
1.62 | 1.69 |
System Inrush Current with
all power supplies loaded (A) | 42 |
48 | 87 |
92 | 96 |
100 | Power
cord requirements | Nema 5-15P
to IEC320-C13 | Option no./Spare
no: 227099-001/187335-001 | | IEC320-C13
to IEC320-C14 | Option no./Spare
no: 142257-001/142258-B21 |
Example of real input watts consumed versus rated watts consumed is available
via the online tool located at url: https://inline.compaq.com/pg/ecg/issd/power/psupply.asp
select system calculator for one of the systems and reference the green fields
at the bottom of the calculator. NOTES: * To review typical
system power ratings use the Active Answers Power Calculator which is available
via the online tool located at URL: https://h30099.www3.hp.com/configurator/powercalcs.asp.
To drill down to calculators: - Click on: "ProLiant
Servers" - Click on the Server of interest. Example: ML330
G3 - Click on: "Power Calculator" link (You may need
to scroll down to see it.) |
|
Server Power Cords One 12 Ft.
lowline power cord ships standard. |
12 ft. Power Cords (13
Cord Sets) |
Power Cord Part Number |
|
163719-002 |
Quickspecs
System Unit
|
Dimensions (HxWxD)
(with feet)
|
16.8 x 7.5 x 20.25 in (41.91 x
19.05 x 51.44 cm) |
Weight |
40 lb (18.18 kg) |
Input Requirements
(per power supply)
|
Range Input Voltage
|
100 to 199 VAC/200 to 240 VAC |
Normal Line Voltage |
115 to 230 VAC |
Line Frequency |
50 to 60 Hz |
|
Rated Input Current |
<6A 100VAC to 199VAC |
|
<3A 200VAC to 240VAC |
BTU Rating |
1,560 BTU |
|
SCSI Connectors
|
One internal HD68 connectors |
NOTE: Support
for either one internal, or one external is available. Internal cabling
is included with the server. External SCSI cabling from the integrated SCSI
controller is achieved using an internal to external SCSI cable option kit
(PN 159547-B22 or 333370-B21). |
Power Supply Output
Power
(per power supply) |
Rated Steady-State Power |
300W |
Maximum Peak Power |
400W |
Temperature Range |
Operating |
50° to 93° F (10°
to 35° C) |
Shipping |
-40° to 150° F (-40°
to 66° C) |
Relative Humidity
(non-condensing) |
Operating |
20% to 80% |
Non-operating |
5% to 90% |
Acoustic Noise
|
Idle
(Fixed Disk Drives Spinning) |
|
L WAd (BELS)
|
5.1 |
L pAm (dBA)
|
34 |
Operating
(Random Seeks to Fixed Disks)
|
|
L WAd (BELS)
|
5.5 |
L pAm (dBA)
|
38 |
|
48X Max IDE
CD-ROM Drive
|
Disk
|
Applicable Disk
|
CD-ROM (modes 1 and 2); mixed mode
(audio and data combined) |
|
CD-DA |
|
Photo CD (Single- and Multi-session) |
|
|
CD-XA (mode 2, forms 1 and 2) |
|
|
CDI ready ; CD-WO |
|
Capacity
|
650 MB |
Block Size
|
Mode 1
|
2,048 bytes, 1024 bytes |
|
Mode 2
|
2,340 bytes, 2,336 bytes, 1024 bytes |
|
CD-DA
|
2,352 bytes |
|
CD-XA |
2,328 bytes |
Interface
|
IDE (ATAPI)
|
|
Access Times (typical)
|
Random
|
<100 ms |
Full-Stroke
|
<150 ms |
Audio Output Level
|
Line-Out |
0.7 VRMS at 47 kOhms |
Data Transfer Rate |
Sustained
|
150 KB/s (single), 1,500 to 7,200
KBps
(10x to 48x) |
Burst |
150 KB/s to 7,200 KB/s |
Cache Buffer
|
128 KB
|
|
Start-up Time (typical)
|
<7seconds
|
|
Stop Time |
<4seconds |
|
Laser Parameters
|
Type |
Semiconductor Laser GaA1As |
Wave Length
|
780 ± 25 nm |
Operating Conditions
|
Temperature
|
41° to 113° F (5° to
45° C) |
Humidity
|
10% to 80% |
Dimensions
|
(HxWxD, maximum)
|
1.7 x 5.85 x 8.11 in (42.9 x 150
x 208 cm) |
|
Weight
|
2.09 lb (0.95 kg) |
|
NC7760 PCI Gigabit
Server Adapter (embedded) |
Network Interface |
10Base-T/100Base-TX/1000Base-TX |
Compatibility |
IEEE 802.3 10Base-T |
IEEE 802.3ab 1000Base-T |
IEEE 802.3u 100Base-TX |
Data Transfer Method |
32-bit bus-master
PCI |
Network Transfer
Rate |
10Base-T (Half-Duplex) |
10 Mb/s |
10Base-T (Full-Duplex) |
20 Mb/s |
100Base-TX (Half-Duplex) |
100 Mb/s |
1000Base-TX (Half and Full-Duplex) |
2000Mb/s |
Connector |
RJ-45 |
Cable Support |
10Base-T |
Categories 3, 4 or 5 UTP; up to
328 ft (100 m) |
10/100/1000Base-TX |
Category 5 UTP; up to 328 ft (100
m) |
|
Integrated Single Channel Wide Ultra3 SCSI Adapter in PCI Slot 1
|
Drives Supported |
Up to 14 SCSI devices Wide Ultra320,
Wide Ultra3 and Wide Ultra2 SCSI hard drives |
Data Transfer Method |
64-bit/33-MHz PCI bus-master |
SCSI Channel Transfer Rate |
160 MB/s per channel |
Maximum Transfer Rate per PCI
Bus (peak) |
267 MB/s per channel |
SCSI Protocols |
Wide Ultra 3 SCSI and Wide Ultra2
SCSI |
Electrical Protocol |
Low Voltage Differential (LVD) |
SCSI Termination |
Active Termination |
External SCSI Connectors |
External SCSI cabling from the integrated
SCSI controller is achieved using an internal to external SCSI cable option
kit (PN 159547-B22 or 333370-B21). |
Internal SCSI Connectors |
One 68-Pin Wide Ultra SCSI-3 connectors |
|
|