|
DL QuickSpecs
|
DL20
|
|
DL60
|
|
DL80
|
|
DL120
|
|
DL140
|
|
DL145
|
|
DL160
|
|
DL160se
|
|
DL165
|
|
DL180
|
|
DL185
|
|
DL320
|
|
DL325
|
|
DL345
|
|
DL360
|
|
DL365
|
|
DL380
|
|
DL385
|
|
DL388
|
|
DL560
|
|
DL580
|
|
DL585
|
|
DL740
|
|
DL760
|
|
DL785
|
|
DL1000
|
|
|
ML QuickSpecs
|
ML30
|
|
ML110
|
|
ML115
|
|
ML150
|
|
ML310
|
|
ML330
|
|
ML350
|
|
ML370
|
|
ML530
|
|
ML570
|
|
ML750
|
|
|
BL QuickSpecs
|
BL10e
|
|
BL20p
|
|
BL25p
|
|
BL260c
|
|
BL280c
|
|
BL2x220c
|
|
BL30p
|
|
BL35p
|
|
BL40p
|
|
BL420c
|
|
BL45p
|
|
BL460c
|
|
BL465c
|
|
BL480c
|
|
BL495c
|
|
BL60p
|
|
BL620c
|
|
BL660c
|
|
BL680c
|
|
BL685c
|
|
BL860c
|
|
|
SL QuickSpecs
|
SL160z
|
|
SL165z
|
|
SL170s
|
|
SL170z
|
|
SL230s
|
|
SL250s
|
|
SL270s
|
|
SL2x170z
|
|
SL335s
|
|
SL390s
|
|
SL4540
|
|
SL4545
|
|
|
XL QuickSpecs
|
XL170r
|
|
XL190r
|
|
XL220a
|
|
XL230a
|
|
XL730f
|
|
XL740f
|
|
XL750f
|
|
|
CL QuickSpecs
|
CL1850
|
CL1850 G1
| |
CL380
|
CL380 G1
| |
|
|
|
|
|
|
|
Proliant DL360 G4p QuickSpecs |
US QuickSpecs |
|
|
|
|
|
|
|
|
|
Proliant DL360 G4p Overview
HP ProLiant DL360 Generation 4p (G4p)
|
|
|
Ultra320 SCSI and SATA Model
|
Serial Attached SCSI (SAS) Model
|
|
1. |
Removable server hood |
2. |
Up to two Intel Xeon™ processors |
3. |
Removable processor fan assembly with front and
secure internal USB ports |
4.
| Removable media bay |
5.
|
Two Ultra320 hot plug drive
bays; or
Two SATA pluggable drive bays; or
Four Serial Attached SCSI hot plug drive bays |
|
6.
|
Sliding rails standard for in rack
servicing |
7.
|
Redundant power supplies |
8. |
1 full length and 1 half length
PCI-X slots (optional PCI Express) |
9. |
Up to 12 GB DDR2 PC2-3200 SDRAM |
|
|
|
What's New
- 2.8 GHz Dual-core Intel®
Xeon™ processors are now available with the powerful HP ProLiant
DL360 G4p Serial Attached SCSI (SAS) model. Offering up to a 50% performance
increase over single-core processors, the Dual-core Intel Xeon offers
a 2x2MB L2 cache and 64-bit capability.
- 3.8 GHz Intel® Xeon™ processors are available
now available with robust HP ProLiant DL360 G4p SCSI and SAS models
and includes 2MB L2 cache and 64-bit support.
- Introducing Xeon™ 3.0 GHz low voltage processor
for performance per watt optimization in dense server environments.
|
|
At A Glance
Combining concentrated 1U compute power, integrated
Lights-Out management, and essential fault tolerance, the DL360 is optimized
for space constrained installations. Dual Xeon processors, DDR2 SDRAM,
and PCI-X and PCI Express technology provide a high performance system
ideal for the full range of scale out applications. What's more, the DL360
G4p steps up the fault tolerant in an ultra dense platform with redundant
power, redundant fans, and online spare memory, embedded RAID capability,
and full-featured remote Lights-Out\ management.
- Processors:
- 64-bit Intel® Xeon™ processors supporting 64-bit extension
and 64-bit Microsoft Windows and Linux operating systems
- SAS Model - best performance:
- Up to 2.8 GHz Dual-core and 3.8 GHz single core Intel Xeon
processor options
- SCSI Model - best price/performance:
- Up to 3.8 GHz single core processor Intel Xeon processor options
- SATA Model - best priced:
- Up to 3.6 GHz single core processor Intel Xeon processor options
- Memory:
- Up to 12 GB of PC2-3200 DDR2 400 SDRAM; with
2-way interleaving
- Advanced ECC memory standard; optional Online
Spare Memory
- Storage Controller:
- SAS Model - best performance:
- HP Smart Array P600/256 BBWC Controller
- SCSI Model - best price/performance:
- Embedded Smart Array 6i RAID Controller with
optional 128MB transportable battery backed cache (SCSI models)
- SATA Model - best priced:
- Embedded 2 Port SATA Controller (SATA models)
- Internal Drive Support:
- SAS Model - best performance:
- Up to four Small Form Factor (SFF) Serial
Attached SCSI (SAS) hot plug hard drives or four SFF Serial
ATA (SATA) hard drives
- SCSI Model - best price/performance:
- Up to two Universal SCSI hot plug disk drives
- SATA Model - best priced:
- Up to two pluggable Serial ATA disk drives
- Network Controller:
- Embedded NC7782 PCI-X Gigabit Server Adapter
- Expansion Slots:
- Two 64-bit/133 MHz PCI-X slots
- Optional PCI-X to PCI-Express conversion kit
- USB Ports:
- 3 Total: 1 front, 1 internal, 1 rear accessible
port
- Redundancy:
- Fan redundancy, standard
- Hot plug power supply with optional 1+1 redundancy
- Management:
- Built in reliability and availability features:
embedded RAID, redundant fans, redundant power option, pre-failure
notifications, and Lights-Out Management
- Integrated Lights-Out (iLO) remote management
embedded on every HP ProLiant DL360 G4p
- Optional Integrated Lights-Out support for Power
Regulator for ProLiant and introducing support for the draft DMTF
System Management Architecture for Server Hardware Command Line
Protocol standard
- HP Power Regulator for ProLiant delivering server
level, policy based power management with industry leading energy
efficiency and savings on system power and cooling costs
- Support for iLO Shared Network Port enables access
to the iLO management processor through one of the embedded system
NICs
- ProLiant Essential Foundation Pack standard,
including HP Systems Insight Manager, SmartStart, SmartStart Scripting
Toolkit, Subscriber's Choice and ROM Based Setup Utility (RBSU).
- Form Factor:
- 1U Rack form factor (1.75")
- Deployment/Serviceability:
- Sliding rails for in rack servicing ship standard;
optional ambidextrous cable management arm
- Warranty:
- Protected by HP Services and a worldwide network
of resellers and service providers. Three-year Next Business Day,
on-site limited global warranty. Certain restrictions and exclusions
apply. Pre-Failure Notification on processors, memory, and SCSI/SAS
hard drives. SATA hard drives have a one-year warranty.
|
Standard Features
NOTE:
For the Standard Features shipped in the "Factory Integrated Models", please see
the "Configuration Information - Factory Integrated Models" section. |
Processor
One of the following depending on Model
|
Intel Xeon Processor 2.8 GHz/800MHz
-2MB L2, 110W |
Intel Xeon Processor 3.0 GHz/800MHz
-2MB L2, 110W |
Intel Xeon Processor 3.0 GHz/800MHz
-2MB L2, Low Voltage 55W |
Intel Xeon Processor 3.2 GHz/800MHz
-2MB L2, 110W |
Intel Xeon Processor 3.4 GHz/800MHz
-2MB L2, 110W |
Intel Xeon Processor 3.6 GHz/800MHz
-2MB L2, 110W |
Intel Xeon Processor 3.8 GHz/800MHz
-2MB L2, 110W |
Dual-core Intel Xeon Processor
2.8 GHz/800MHz - 2x2MB L2, 135W
NOTE: Dual-core processor is supported
on HP ProLiant DL360 G4p Serial Attached SCSI (SAS) models only. |
|
Processor Cache |
2MB Level 2 cache memory |
|
Upgradeability |
Upgradeable to dual
processing |
|
Chipset |
Intel chipset is E7520 |
|
Memory Protection
& Functionality |
Advanced ECC (multi-bit error
protection) |
Online spare |
2-way interleaving |
|
Memory |
Type |
PC2-3200 DDR2 400 SDRAM |
Standard |
1 GB (2 x 512 MB) |
Standard (on some models) |
2 GB (2 x 1024 MB) |
Maximum |
12 GB |
|
Network Controller |
Embedded NC7782 PCI-X Gigabit
Server Adapter |
|
Expansion Slots |
Slot Number
|
Bus Speed |
Bus Number* |
Device Number** |
Hot Plug |
PCI Voltage |
1
|
64-bit/133MHz
PCI-X |
7
|
0
|
no
|
3.3 Volt
|
1
|
x8 PCI Express (option) |
3
|
0
|
no
|
n/a
|
2
|
64-bit/133MHz
PCI-X |
10
|
0
|
no
|
3.3 Volt
|
2
|
x8 PCI Express (option) |
13
|
0
|
no
|
n/a
|
*NOTE:
Default bus assignment. Inserting cards with PCI bridges may alter the actual
bus assignment number.
**NOTE: Slots are enumerated differently based on OS. MS OS's enumerate
from lowest to highest Device ID by bus (starting with the lowest bus).
NOTE: All slots can accept universal keyed PCI cards. |
|
Manageability |
Integrated Lights-Out (iLO) Management (integrated on motherboard)
|
|
Storage Controllers |
SAS Models
|
HP Smart Array P600/256 BBWC
Controller (installed in PCI-X slot)
NOTE: The Smart Array P600 controller
offers an external 4X SAS port for additional storage expansion. |
SCSI Models |
HP Smart Array 6i Controller
(embedded)
NOTE: The HP ProLiant DL360 G4p does
not offer an external SCSI port. |
SATA Models |
HP embedded 2 Port SATA Controller
(integrated on system board)
NOTE: The HP embedded 2 Port SATA
controller does not support RAID, hot plug drive functionality or drive
activity LEDs.
NOTE: SATA RAID 0, 1 is available with the optional purchase of the
HP 8-port SAS HBA ( 347786-B21) and HP SAS/SATA Cable Kit ( 398307-B21) -
hot-plug drive functionality and drive activity LEDS not supported. |
|
Storage |
Optical Drives |
Ejectable CD-ROM
(Standard in most models), DVD-ROM, or DVD-RW drives, or Slimline floppy
NOTE: Slimline Floppy Diskette Drive
is not supported in SCSI and SATA models. |
Diskette Drive
|
1.44 MB Diskette
Drive
NOTE: Standard in SCSI models; optional
in SATA models; not available in SAS models. |
Drive Bays |
SAS Model |
4 Small Form Factor |
SCSI Model |
2 HP Universal SCSI |
SATA Model |
2 Pluggable SATA |
|
Maximum
Internal Storage Type | SAS
Model |
584GB SAS |
4 x 146GB SAS |
240GB
SATA | 4 x 60GB Serial ATA |
SCSI Model | 600GB
| 2 x 300GB Ultra320 SCSI |
SATA Model |
1.50TB |
2 x 750GB Serial ATA |
|
Graphics |
Integrated ATI RAGE XL Video
Controller with 8-MB SDRAM Video Memory |
|
Form Factor |
Rack (1U), (1.75 in/4.45 cm) |
|
ProLiant
Essentials Foundation Pack Software |
HP Systems Insight Manager |
HP Systems Insight Manager (HP SIM) provides a unified, secure
and extensible environment to centrally manage servers, storage
and other infrastructure devices across multiple operating system
platforms.
Through a single management view, HP SIM provides core management
services that include device discovery and identification, event
views, health monitoring, inventory data collection, software version
control and reporting. HP SIM is built on industry standards and
is extensible with value-added ProLiant Essentials, Integrity Essentials
and Storage Essentials software to meet individual management needs.
For more details on HP SIM visit https://www.hp.com/go/hpsim.
HP SIM provides organizations with the following benefits:
- Simplifies and consolidates infrastructure lifecycle management
using task and query based functionality
- Provides the foundation for infrastructure automation and virtualization
- Enables IT management based on business processes not hardware
platforms
- Lowers infrastructure maintenance cost and frees resources for
innovation
- Maximizes resource utilization with virtualization technologies
- Provides a central point of integration between infrastructure
and Enterprise management tools such as HP OpenView
|
SmartStart |
SmartStart is a tool that
simplifies server setup, providing a rapid way to deploy reliable
and consistent server configurations. For more information, please
visit the SmartStart Web site at https://www.hp.com/servers/smartstart.
SmartStart version supported (minimum):
SmartStart 7.2. |
Insight Management Agents |
Insight Management Agents
should be installed on all HP servers to present system instrumentation,
health and configuration information into HP Systems Insight Manager
and the HP System Management Homepage. The HP System Management Homepage
aggregates systems data from Insight Management Agents and other HP
management tools, providing a consolidated browser-based interface
for managing individual servers,
Insight Management Agents and The HP System Management Homepage are
included on ProLiant Support Packs, and can also be installed using
the server profiles provided with the ProLiant Essentials Rapid Deployment
Pack. For additional information about the Management Agents and the
HP System Management Homepage please visit the management Web site
at https://www.hp.com/servers/manage |
Subscriber's Choice |
Subscriber's Choice Driver
and Support Alerts/Notifications is a web-based email subscription
service that provides automatic delivery of software and driver change
notifications for ProLiant products. Sign up at https://www.hp.com/go/subscriberschoice
and customize your profile to receive various new alerts as they become
available, on a weekly or monthly basis. |
ROMPaq, support software,
and
configuration utilities
|
The latest software, drivers,
and firmware fully optimized and tested for your ProLiant server and
options available in SmartStart or downloadable from Software and
Drivers download pages: https://www.hp.com/go/support |
Insight Diagnostics Online
Edition |
The most advanced configuration
analysis, reporting and troubleshooting utilities used by HP and at
your fingertips, available in SmartStart. |
Optional ProLiant Essentials
Value Packs |
Optional software offerings that selectively extend the functionality
of an Adaptive Infrastructure to address specific business problems
and needs:
- Rapid Deployment Pack (RDP) is an automated deployment and provisioning
solution for all ProLiant servers. RDP includes the ProLiant Integration
Module featuring ProLiant server pre-configured events for OS
installation, and optimized software drivers, firmware and management
agents. Every RDP disc includes a 7-day, 10-node trial licenses
for evaluation purposes. RDP requires a license for each server
deployed and is available for purchase with HP servers. For more
information, visit: https://www.hp.com/servers/rdp.
- Workload Management Pack - provides easier management of complex
environments, improving overall server utilization and enabling
Windows® 2000 customers for the first time to confidently
deploy multiple applications on a single multiprocessor ProLiant
Server.
- Performance Management Pack - a performance management solution
that identifies and explains hardware performance bottlenecks
on ProLiant servers and attached options enabling users to better
utilize their valuable resources.
- Intelligent Networking Pack - detects and analyzes network bottlenecks
or broken network linkages and steers traffic to the optimum route
based on network conditions, plus it provides an extra layer of
protection. The virus throttle feature of the solution slows the
propagation of fast spreading virus
- Vulnerability and Patch Management Pack - identifies and remediates
software security vulnerabilities due to missing patches as well
operating system configurations that can be exploited by viruses,
worms, and other blended threats
- Virtual Machine Management Pack - provides central management
and control of virtual machines from Microsoft and VMware. Integrated
approach provides the ability to manage both physical and virtual
resources from a single management console.
- Server Migration Pack - The Server Migration Pack automates
the manual processes required for migrating servers between physical
or virtual platforms (P2V, V2P, and V2V).
- Server Migration Pack - P2P Edition: Upgrading or replacing
your existing server? Effortlessly transition to new servers with
automated, accurate and affordable migration of OS, application
and data.
|
Optional Remote Management
Packs |
- Integrated Lights-Out Advanced Pack - upgrades the Integrated
Lights-Out processor to full virtual presence and control with
graphical console and virtual media.
|
NOTE:
Flexible and volume quantity license kits are available for ProLiant
Essentials Value Packs. Refer to https://www.hp.com/servers/proliantessentials
or the various ProLiant Essentials Value Pack product QuickSpecs for
more information.
NOTE: For more information regarding ProLiant Essentials Software,
please see the following URL: https://www.hp.com/servers/proliantessential.
|
|
|
Industry Standard
Compliance |
ACPI 1.0b Compliant |
PCI 2.2 Compliant |
|
Microsoft® Logo certifications |
|
USB 1.1 and 2.0 Compliant |
|
Remote Manageability |
Integrated Lights-Out (iLO) Standard Management:
- Virtual Text Remote Console
- Virtual Power Button Control
- Dedicated & shared LAN Connectivity
- Browser and command line access
- Automatic IP Configuration via DHCP/DNS/WINS
- Industry Standard 128-bit Secure Sockets Layer (SSL) and Secure Shell
Security
- IML and iLO Event Logging
- Support for 12 user accounts with customizable access privilege
Integrated Lights Out Advanced Pack (optional)
Remote Lights out Edition ll (optional)
|
|
Intelligent Manageability |
HP Systems Insight Manager
SmartStart
Remote Insight Lights-Out Edition ll (optional)
ROM-Based Setup Utility (RBSU)
Remote-Flash Redundant ROM
Integrated Management Log (IML)
Server Health logging
Automatic Server Recovery-2 (ASR-2)
System Interconnect Status Indicators
Dynamic sector repairing and drive parameter tracking (with Smart Array
controllers)
Hot Spare Boot
(NOTE: Upon the event of a failed
processor or VRM in a multi-processing environment, the system will automatically
reboot and use the remaining good processor(s).)
Power Down Utility
Pre-Failure Warranty (covers processors, as well as SCSI/SAS hard drives
and memory) |
|
Security |
Power-on password
Keyboard password
Diskette drive control
Diskette boot control
QuickLock, Network Server Mode
Removable CD and Diskette Drive Assembly
Serial interface control
Administrator's password
Disk configuration lock
Integrated Lights-Out has 12 customizable user accounts and SSL encryption
Integrated Lights-Out can be disabled via a Global Setting |
|
Server
Power Cords |
One Lowline NEMA power cord
and One Highline IEC Power cord ships standard in most NA models. Smart
Buys include one IEC power cable per power supply. Localized cables included
with geographic specific models in other world regions. |
|
Power Supply |
SAS Models:
|
535W Optional (1+ 1 redundant)
power supply
NOTE: PN 389830-B21 contains the
optional power supply and an IEC power cable only; purchase if connecting
to PDU/UPS that supports IEC cables. PN 389830-001 contains a low line (NEMA)
power cord only. |
SCSI & SATA Models: |
460W Optional (1+ 1 redundant)
power supply
NOTE: PN 354587-B21 contains the
optional power supply and an IEC power cable only; purchase if connecting
to PDU/UPS that supports IEC cables. PN 354587-001 contains a low line (NEMA)
power cord only. |
|
System Fans |
7 fans ship standard; Fan redundancy
standard |
|
Rack
Airflow Requirements |
Rack 10000 series Cabinets
The increasing power of new high-performance processor technology requires
increased cooling efficiency for rack-mounted servers. The 10000 Series
Racks provide enhanced airflow for maximum cooling, allowing these racks
to be fully loaded with servers using the latest processors.
CAUTION: If a third-party rack
is used, observe the following additional requirements to ensure adequate
airflow and to prevent damage to the equipment:
- Front and rear doors:
If your 42U server rack includes closing front and rear doors, you must
allow 830 square inches (5,350 sq cm) of hole evenly distributed from
top to bottom to permit adequate airflow (equivalent to the required
64 percent open area for ventilation).
- Side: The clearance between the installed
rack component and the side panels of the rack must be a minimum of
2.75 inches (7 cm).
CAUTION: Always use blanking panels
to fill all remaining empty front panel U-spaces in the rack. This arrangement
ensures proper airflow. Using a rack without blanking panels results in
improper cooling that can lead to thermal damage.
|
|
NOTE: For additional information, refer to the Setup and Installation Guide
or the Documentation CD provided with the server, or to the server documentation
located in the Support section at the following URL: https://h18000.www1.hp.com/products/servers/proliantdl360/index.html. |
|
Factory Express Portfolio for
Servers and Storage |
HP Factory Express offers configuration, customization, integration and
deployment services for HP servers and storage products. Customers can
choose how their factory solutions are built, tested, integrated, shipped
and deployed.
Factory Express offers service packages for simple
configuration, racking, installation, complex configuration and design services as well
as individual factory services, such as image loading, asset tagging, and
custom packaging. HP products supported through Factory Express include a wide
array of servers and storage: HP Integrity, HP ProLiant, HP ProLiant
Server Blades, HP BladeSystem, HP 9000 servers as well as the MSA1000,
VA7xxx, EVA, XP, rackable tape libraries and configurable network switches.
For more information on Factory Express services for your specific server
model please contact your sales representative or go to https://www.hp.com/go/factory-express.
|
|
HP Enterprise Configurator |
The HP eCo-Enterprise Configurator
now provides factory default racking for our HP hardware portfolio. This
approach is aligned with our strategic direction to meet the needs and expectations
of our valued customers. If you require "custom" rack configuration,
please contact HP's Customer Business Center or an Authorized Partner for
assistance. |
|
Service and Support |
This product is covered by a global limited warranty and supported by
HP Services and a worldwide network of resellers and service providers.
Hardware diagnostic support and repair is available for three years from
date of purchase. Support for software and initial setup is available
for 90 days from date of purchase. Additional support may be covered under
the warranty or available for an additional fee. Enhancements to warranty
services are available through HP Care Pack services or customized service
agreements.
NOTE: Server Warranty includes 3 year
Parts, 3 year Labor, 3-year on-site support. Additional information regarding
worldwide limited warranty and technical support is available at: https://h18004.www1.hp.com/products/servers/platforms/warranty/index.html
HP Care Pack services include coverage for the HP branded hardware options
qualified for the server, purchased at the same time or afterward, internal
to the enclosure, as well as 22" and smaller external monitors and
tower UPS options up to 3kVA; these items will be covered at the same
service level and for the same coverage period as the server. Coverage
of UPS Battery is not included, standard warranty terms & conditions
apply. For servers or storage systems installed within a rack, service
also covers all HP qualified rack options installed within the same rack.
HP services provide continuous care and support expertise with committed
response designed to meet your IT and business needs.
To fully capitalizing on your HP ProLiant servers' capabilities requires
a service partner who thoroughly understands your server technology and
systems environment. HP Services, an industry leader in provision of multi
vender support solutions provides a range of support services designed
to meet the varying needs of business. Whether an SMB or large global
corporation HP has a ProLiant server support offer to help you speedily
deploy and maximize system uptime.
Enhanced Care - Minimum recommended service support offer designed to
ensure customers have access to expert assistance, whenever they need
it.
- 4-Hour On-site Service, 7-Day x 24-Hour Coverage, 3 Years
Continuance Care - Recommended service delivering cost-effective support
options designed to extend HP Services committed response and guaranteed
fix times, designed to speed problem identification and resolution.
- 6-Hour Call to Repair, On-site Service, 7-Day x 24-Hour Coverage,
3 Years
Total Care - Highest HP Support service level recommend to help increase
IT performance and availability with comprehensive, integrated hardware
and software services
- Support Plus 24 - Onsite HW support 24x7, 4hr response and Microsoft
O/S SW Tech support offsite, onsite at HP's discretion, 24x7 2hr response
time incl. HP holidays
Deployment Services - HP Installation and Start Up services designed
to take time, risk, and worry out of the deployment of ProLiant servers
- and free customers IT support staff to focus on what they do best, their
business.
- Installation & Start-Up of a ProLiant server and Microsoft
or Linux O/S per the Customer Description and/or Data Sheet. To be delivered
on a scheduled basis 8am-5pm, M-F, excl. HP holidays
|
NOTE: For a
complete listing of service offerings and information visit:
https://www.hp.com/services/proliantservices
https://www.hp.com/go/proliant/carepack |
Models
SAS Models |
DL360R04p X3.0-2MB/800,
1GB SAS
389820-xx1 |
Processor |
(1) Intel Xeon Processor 3.0
GHz/800MHz standard (up to 2 supported) |
Cache Memory |
2MB level 2 cache |
Memory |
1 GB (2 x 512 MB) Standard to
12 GB (Maximum) of PC2-3200 DDR2 400 SDRAM |
Network Controller |
Embedded NC7782 PCI-X Gigabit
Server Adapter |
Storage Controller |
HP Smart Array P600/256 BBWC
Controller |
Hard Drives |
None ship standard; system supports
up to four Serial SCSI or Serial ATA drives. |
Remote Management |
Integrated Lights-Out (iLO)
Standard Management (embedded) |
Power Supply |
One 535W power supply (redundant
power supply optional) |
Optical Drive |
Slimline CD-ROM Drive |
PCI-X Slots |
1 full length and 1 half length
64bit/133 MHz PCI-X slot
NOTE: Full length slot is occupied
with HP Smart Array P600 Controller and is not available. |
Form Factor |
Rack (1U), (1.75 in/4.45 cm) |
|
DL360R04p X3.2-2MB/800, 2GB SAS RPS
389821-xx1
|
Processor |
(1) Intel Xeon Processor 3.2 GHz/800MHz
standard (up to 2 supported) |
Cache Memory |
2MB level 2 cache |
Memory |
2 GB (2 x 1024 MB) Standard to 12
GB (Maximum) of PC2-3200 DDR2 400 SDRAM |
Network Controller |
Embedded NC7782 PCI-X Gigabit
Server Adapter |
Storage Controller |
HP Smart Array P600/256 BBWC
Controller |
Hard Drives |
None ship standard; system supports
up to four Serial SCSI or Serial ATA drives. |
Remote Management |
Integrated Lights-Out (iLO)
Standard Management (embedded) |
Power Supply |
Two 535W power supplies (1+1
redundant) |
Optical Drive |
Slimline CD-ROM Drive |
PCI-X Slots |
1 full length and 1 half length
64bit/133 MHz PCI-X slot
NOTE: Full length slot is occupied
with HP Smart Array P600 Controller and is not available. |
Form Factor |
Rack (1U), (1.75 in/4.45 cm) |
|
DL360R04p X3.4-2MB/800, 2GB SAS RPS
389822-xx1
|
Processor |
(1) Intel Xeon Processor 3.4
GHz/800MHz standard (up to 2 supported) |
Cache Memory |
2MB level 2 cache |
Memory |
2 GB (2 x 1024 MB) Standard
to 12 GB (Maximum) of PC2-3200 DDR2 400 SDRAM |
Network Controller |
Embedded NC7782 PCI-X Gigabit
Server Adapter |
Storage Controller |
HP Smart Array P600/256 BBWC
Controller |
Hard Drives |
None ship standard; system supports
up to four Serial SCSI or Serial ATA drives. |
Remote Management |
Integrated Lights-Out (iLO)
Standard Management (embedded) |
Power Supply |
Two 535W power supplies (1+1
redundant) |
Optical Drive |
Slimline CD-ROM Drive |
PCI-X Slots |
1 full length and 1 half length
64bit/133 MHz PCI-X slot
NOTE: Full length slot is occupied
with HP Smart Array P600 Controller and is not available. |
Form Factor |
Rack (1U), (1.75 in/4.45 cm) |
|
DL360R04p X3.6-2MB/800, 2GB SAS RPS
389823-xx1
|
Processor |
(1) Intel Xeon Processor 3.6
GHz/800MHz standard (up to 2 supported) |
Cache Memory |
2MB level 2 cache |
Memory |
2 GB (2 x 1024 MB) Standard
to 12 GB (Maximum) of PC2-3200 DDR2 400 SDRAM |
Network Controller |
Embedded NC7782 PCI-X Gigabit
Server Adapter |
Storage Controller |
HP Smart Array P600/256 BBWC
Controller |
Hard Drives |
None ship standard; system supports
up to four Serial SCSI or Serial ATA drives. |
Remote Management |
Integrated Lights-Out (iLO)
Standard Management (embedded) |
Power Supply |
Two 535W power supplies (1+1
redundant) |
Optical Drive |
Slimline CD-ROM Drive |
PCI-X Slots |
1 full length and 1 half length
64bit/133 MHz PCI-X slot
NOTE: Full length slot is occupied
with HP Smart Array P600 Controller and is not available. |
Form Factor |
Rack (1U), (1.75 in/4.45 cm) |
|
DL360R04p X3.8-2MB/800, 2GB SAS RPS
394919-xx1
|
Processor |
(1) Intel Xeon Processor 3.8
GHz/800MHz standard (up to 2 supported) |
Cache Memory |
2MB level 2 cache |
Memory |
2 GB (2 x 1024 MB) Standard
to 12 GB (Maximum) of PC2-3200 DDR2 400 SDRAM |
Network Controller |
Embedded NC7782 PCI-X Gigabit
Server Adapter |
Storage Controller |
HP Smart Array P600/256 BBWC
Controller |
Hard Drives |
None ship standard; system supports
up to four Serial SCSI or Serial ATA drives. |
Remote Management |
Integrated Lights-Out (iLO)
Standard Management (embedded) |
Power Supply |
Two 535W power supplies (1+1
redundant) |
Optical Drive |
Slimline CD-ROM Drive |
PCI-X Slots |
1 full length and 1 half length
64bit/133 MHz PCI-X slot
NOTE: Full length slot is occupied
with HP Smart Array P600 Controller and is not available. |
Form Factor |
Rack (1U), (1.75 in/4.45 cm) |
|
SCSI
Models | | |
DL360R04p
X3.8-2MB/800, 2GB SCSI, RPS 376235-xx1 | Processor | (1)
Intel Xeon Processor 3.8 GHz/800MHz standard (up to 2 supported) |
Cache Memory | 2MB
level 2 cache | Memory | 2
GB (2 x 1 GB) Standard to 12 GB (Maximum) of PC2-3200 DDR2 400 SDRAM |
Network Controller |
Embedded NC7782 PCI-X Gigabit
Server Adapter |
Storage
Controller | Smart Array 6i Controller
(U320, embedded on system board) NOTE:
The HP ProLiant DL360 G4p does not offer an external SCSI port. |
Hard Drives |
None ship standard; system supports up to two hot plug U320 drives NOTE:
The HP ProLiant DL360 G4p SCSI models only support U320 Universal Hot Plug drives.
| Remote Management | Integrated
Lights-Out (iLO) Standard Management (embedded) | Power
Supply | Two 460W power supplies
| Optical Drive | 24x
IDE CD-ROM Drive (Low-profile) | Diskette
Drive | 1.44 MB Diskette Drive |
PCI-X Slots | 1
full length and 1 half length 64bit/133MHz PCI-X slot | Form
Factor | Rack (1U), (1.75 in/4.45
cm) | |
DL360R04p X3.6-2MB/800, 1GB SCSI 376236-xx1 | Processor | (1)
Intel Xeon Processor 3.6 GHz/800MHz standard (up to 2 supported) |
Cache Memory | 2MB
level 2 cache | Memory | 1
GB (2 x 512 MB) Standard to 12 GB (Maximum) of PC2-3200 DDR2 400 SDRAM |
Network Controller |
Embedded NC7782 PCI-X Gigabit
Server Adapter |
Storage
Controller | Smart Array 6i Controller
(U320, embedded on system board) NOTE:
The HP ProLiant DL360 G4p does not offer an external SCSI port. |
Hard Drives |
None ship standard; system supports up to two hot plug U320 drives NOTE:
The HP ProLiant DL360 G4p SCSI models only support U320 Universal Hot Plug
drives. | Remote
Management | Integrated Lights-Out
(iLO) Standard Management (embedded) | Power
Supply | One 460W power supply
(redundant power supply optional) | Optical
Drive | 24x IDE CD-ROM Drive (Low-profile) |
Diskette Drive | 1.44
MB Diskette Drive | PCI-X
Slots | 1 full length and 1 half
length 64bit/133MHz PCI-X slot | Form
Factor | Rack (1U), (1.75 in/4.45
cm) | |
DL360R04p X3.6-2MB/800, 2GB SCSI, RPS 378705-xx1 | Processor | (1)
Intel Xeon Processor 3.6 GHz/800MHz standard (up to 2 supported) |
Cache Memory | 2MB
level 2 cache | Memory | 2
GB (2 x 1 GB) Standard to 12 GB (Maximum) of PC2-3200 DDR2 400 SDRAM |
Network Controller |
Embedded NC7782 PCI-X Gigabit
Server Adapter |
Storage
Controller | Smart Array 6i Controller
(U320, embedded on system board) NOTE:
The HP ProLiant DL360 G4p does not offer an external SCSI port. |
Hard Drives |
None ship standard; system supports up to two hot plug U320 drives NOTE:
The HP ProLiant DL360 G4 SCSI models only support U320 Universal Hot Plug
drives. | Remote
Management | Integrated Lights-Out
(iLO) Standard Management (embedded) | Power
Supply | Two 460W power supplies
(1+1 redundant) | Optical
Drive | 24x IDE CD-ROM Drive (Low-profile) |
Diskette Drive | 1.44
MB Diskette Drive | PCI-X
Slots | 1 full length and 1 half
length 64bit/133MHz PCI-X slot | Form
Factor | Rack (1U), (1.75 in/4.45
cm) | |
DL360R04p X3.4-2MB/800, 2GB SCSI, RPS 380079-xx1 | Processor | (1)
Intel Xeon Processor 3.4 GHz/800MHz standard (up to 2 supported) |
Cache Memory |
2MB level 2 cache | Memory | 2
GB (2 x 1-GB) Standard to 12 GB (Maximum) of PC2-3200 DDR2 400 SDRAM |
Network Controller |
Embedded NC7782 PCI-X Gigabit
Server Adapter |
Storage
Controller | Smart Array 6i Controller
(U320, embedded on system board) NOTE:
The ProLiant DL360 G4p does not offer an external SCSI port. |
Hard Drives |
None ship standard; system supports up to two hot plug U320 drives NOTE:
The ProLiant DL360 G4p SCSI models only support U320 Universal Hot Plug drives.
| Remote Management | Integrated
Lights-Out (iLO) Standard Management (embedded) | Power
Supply | Two 460W power supply
(1+1 redundant) | Optical
Drive | 24x IDE CD-ROM Drive (Low-profile) |
Diskette Drive | 1.44
MB Diskette Drive | PCI-X
Slots | 1 full length and 1 half
length 64bit/133MHz PCI-X slot | Form
Factor | Rack (1U), (1.75 in/4.45
cm) | |
DL360R04p X3.4-2MB/800, 1GB SCSI 376237-xx1 | Processor | (1)
Intel Xeon Processor 3.4 GHz/800MHz standard (up to 2 supported) |
Cache Memory | 2MB
level 2 cache | Memory | 1
GB (2 x 512 MB) Standard to 12 GB (Maximum) of PC2-3200 DDR2 400 SDRAM |
Network Controller |
Embedded NC7782 PCI-X Gigabit
Server Adapter |
Storage
Controller | Smart Array 6i Controller
(U320, embedded on system board) NOTE:
The HP ProLiant DL360 G4p does not offer an external SCSI port. |
Hard Drives |
None ship standard; system supports up to two hot plug U320 drives NOTE:
The HP ProLiant DL360 G4 SCSI models only support U320 Universal Hot Plug
drives. | Remote
Management | Integrated Lights-Out
(iLO) Standard Management (embedded) | Power
Supply | One 460W power supply
(redundant power supply optional) | Optical
Drive | 24x IDE CD-ROM Drive (Low-profile) |
Diskette Drive | 1.44
MB Diskette Drive | PCI-X
Slots | 1 full length and 1 half
length 64bit/133MHz PCI-X slot | Form
Factor | Rack (1U), (1.75 in/4.45
cm) | |
DL360R04p X3.2-2MB/800, 1GB SCSI 379753-xx1 | Processor | (1)
Intel Xeon Processor 3.2 GHz/800MHz standard (up to 2 supported) |
Cache Memory | 2MB
level 2 cache | Memory | 1
GB (2 x 512 MB) Standard to 12 GB (Maximum) of PC2-3200 DDR2 400 SDRAM |
Network Controller |
Embedded NC7782 PCI-X Gigabit
Server Adapter |
Storage
Controller | Smart Array 6i Controller
(U320, embedded on system board) NOTE:
The HP ProLiant DL360 G4p does not offer an external SCSI port. |
Hard Drives |
None ship standard; system supports up to two hot plug U320 drives NOTE:
The HP ProLiant DL360 G4 SCSI models only support U320 Universal Hot Plug
drives. | Remote
Management | Integrated Lights-Out
(iLO) Standard Management (embedded) | Power
Supply | One 460W power supply
(redundant power supply optional) | Optical
Drive | 24x IDE CD-ROM Drive (Low-profile) |
Diskette Drive | 1.44
MB Diskette Drive | PCI-X
Slots | 1 full length and 1 half
length 64bit/133MHz PCI-X slot | Form
Factor | Rack (1U), (1.75 in/4.45
cm) | |
DL360R04p X3.0-2MB/800, 1GB SCSI 380325-xx1 | Processor | (1)
Intel Xeon Processor 3.0 GHz/800MHz standard (up to 2 supported) |
Cache Memory | 2MB
level 2 cache | Memory | 1
GB (2 x 512 MB) Standard to 12 GB (Maximum) of PC2-3200 DDR2 400 SDRAM |
Network Controller |
Embedded NC7782 PCI-X Gigabit
Server Adapter |
Storage
Controller | Smart Array 6i Controller
(U320, embedded on system board) NOTE:
The HP ProLiant DL360 G4p does not offer an external SCSI port. |
Hard Drives |
None ship standard; system supports up to two hot plug U320 drives NOTE:
The HP ProLiant DL360 G4 SCSI models only support U320 Universal Hot Plug
drives. | Remote
Management | Integrated Lights-Out
(iLO) Standard Management (embedded) | Power
Supply | One 460W power supply
(redundant power supply optional) | Optical
Drive | 24x IDE CD-ROM Drive (Low-profile) |
Diskette Drive | 1.44
MB Diskette Drive | PCI-X
Slots | 1 full length and 1 half
length 64bit/133MHz PCI-X slot | Form
Factor | Rack (1U), (1.75 in/4.45
cm) | |
SATA Models |
|
|
DL360R04p X3.6-2MB/800, 1GB SATA
378704-xx1
|
Processor |
(1) Intel Xeon Processor 3.6 GHz/800MHz
standard (up to 2 supported) |
Cache Memory |
2MB level 2 cache |
Memory |
1 GB (2 x 512 MB) Standard to 12
GB (Maximum) of PC2-3200 DDR2 400 SDRAM |
Network Controller |
Embedded NC7782 PCI-X Gigabit
Server Adapter |
Storage Controller |
Embedded SATA controller
NOTE: The HP embedded 2 Port SATA
controller does not support RAID, hot plug drive functionality or drive
activity LEDs.
NOTE: SATA RAID 0, 1 is available with the optional purchase of the
HP 8-port SAS HBA ( 347786-B21) and HP SAS/SATA Cable Kit ( 398307-B21) -
hot-plug drive functionality and drive activity LEDS not supported. |
Hard Drives |
None ship standard; system supports
up to two Serial ATA drives |
Remote Management |
Integrated Lights-Out (iLO)
Standard Management (embedded) |
Power Supply |
One 460W power supply (redundant
power supply optional) |
Optical Drive |
Optical Drives not supported
on SATA Models |
Diskette Drive |
Optional floppy on SATA Models |
PCI-X Slots |
1 full length and 1 half length
64bit/133MHz PCI-X slot |
Form Factor |
Rack (1U), (1.75 in/4.45 cm) |
|
DL360R04p X3.4-2MB/800, 1GB SATA
380078-xx1
|
Processor |
(1) Intel Xeon Processor 3.4 GHz/800MHz
standard |
Cache Memory |
2MB level 2 cache |
Memory |
1 GB (2 x 512 MB) Standard to 12
GB (Maximum) of PC2-3200 DDR2 400 SDRAM |
Network Controller |
Embedded NC7782 PCI-X Gigabit
Server Adapter |
Storage Controller |
Embedded SATA controller
NOTE: The HP embedded 2 Port SATA
controller does not support RAID, hot plug drive functionality or drive
activity LEDs.
NOTE: SATA RAID 0, 1 is available with the optional purchase of the
HP 8-port SAS HBA ( 347786-B21) and HP SAS/SATA Cable Kit ( 398307-B21) -
hot-plug drive functionality and drive activity LEDS not supported. |
Hard Drives |
None ship standard; system supports
up to two Serial ATA drives |
Remote Management |
Integrated Lights-Out (iLO)
Standard Management (embedded) |
Power Supply |
One 460W power supply (redundant
power supply optional) |
Optical Drive |
Optical Drives not supported
on SATA Models |
Diskette Drive |
Optional floppy on SATA Models |
PCI-X Slots |
1 full length and 1 half length
64bit/133 MHz PCI-X slot |
Form Factor |
Rack (1U), (1.75 in/4.45 cm) |
|
DL360R04p X3.2-2MB/800, 1GB SATA
379752-xx1
|
Processor |
(1) Intel Xeon Processor 3.2
GHz/800MHz standard (up to 2 supported) |
Cache Memory |
2MB level 2 cache |
Memory |
1 GB (2 x 512 MB) Standard to
12 GB (Maximum) of PC2-3200 DDR2 400 SDRAM |
Network Controller |
Embedded NC7782 PCI-X Gigabit
Server Adapter |
Storage Controller |
Embedded SATA controller
NOTE: The HP embedded 2 Port SATA
controller does not support RAID, hot plug drive functionality or drive
activity LEDs.
NOTE: SATA RAID 0, 1 is available with the optional purchase of the
HP 8-port SAS HBA ( 347786-B21) and HP SAS/SATA Cable Kit ( 398307-B21) -
hot-plug drive functionality and drive activity LEDS not supported. |
Hard Drives |
None ship standard; system supports
up to two Serial ATA drives |
Remote Management |
Integrated Lights-Out (iLO)
Standard Management (embedded) |
Power Supply |
One 460W power supply (redundant
power supply optional) |
Optical Drive |
Optical Drives not supported
on SATA Models |
Diskette Drive |
Optional floppy on SATA Models |
PCI-X Slots |
1 full length and 1 half length
64bit/133 MHz PCI-X slot |
Form Factor |
Rack (1U), (1.75 in/4.45 cm) |
|
DL360R04p X3.0-2MB/800, 1GB SATA
380324-xx1
|
Processor |
(1) Intel Xeon Processor 3.0
GHz/800MHz standard (up to 2 supported) |
Cache Memory |
2MB level 2 cache |
Memory |
1 GB (2 x 512 MB) Standard to
12 GB (Maximum) of PC2-3200 DDR2 400 SDRAM |
Network Controller |
Embedded NC7782 PCI-X Gigabit
Server Adapter |
Storage Controller |
Embedded SATA controller
NOTE: The HP embedded 2 Port SATA
controller does not support RAID, hot plug drive functionality or drive
activity LEDs.
NOTE: SATA RAID 0, 1 is available with the optional purchase of the
HP 8-port SAS HBA ( 347786-B21) and HP SAS/SATA Cable Kit ( 398307-B21) -
hot-plug drive functionality and drive activity LEDS not supported.
|
Hard Drives |
None ship standard; system supports
up to two Serial ATA drives |
Remote Management |
Integrated Lights-Out (iLO)
Standard Management (embedded) |
Power Supply |
One 460W power supply (redundant
power supply optional) |
Optical Drive |
Optical Drives not supported
on SATA Models |
Diskette Drive |
Optional floppy on SATA Models |
PCI-X Slots |
1 full length and 1 half length
64bit/133 MHz PCI-X slot |
Form Factor |
Rack (1U), (1.75 in/4.45 cm) |
|
Country Code Key |
|
Rack Code Key |
|
XX=00 |
US |
|
XX=20 |
Brazil |
|
XX=29 |
Japan |
|
XX=37 |
APD |
|
XX=42 |
EURO |
|
XX=AA |
PRC |
Configuration Information - Factory Integrated Models (North America only)
NOTE: For Configure to Order requirements
within EMEA region, please consult local Sales Contact. NOTE:
HP does not allow factory integration of options into standard models listed
above. Configure-to-order servers must start with a CTO Chassis.
NOTE: This product offering does not support
HP Factory Express Server Configuration Level 1. NOTE: FIO indicates
that this option only available as a Factory Installable Option. |
Step 1: Base Configuration (choose one of the following configurable models) |
Models | HP
ProLiant DL360G4p SATA Rack CTO Chassis (North America) | 382146-405 |
Factory
Integrated Model ships with: | |
Embedded NC7782 PCI-X Gigabit Server Adapter
Embedded SATA Controller (SATA RAID functionality is available via OS)
Integrated Lights-Out (iLO) embedded
1 full length and 1 half length 64-bit/133 MHz PCI-X slot
7 fans; N+1 fan redundancy
Rack (1U), (1.75 in/4.45 cm)
| |
| |
HP ProLiant DL360G4p
SCSI Rack CTO Chassis (North America) |
382147-405 |
Factory Integrated Model ships with: | |
Embedded NC7782 PCI-X Gigabit Server Adapter
Smart Array 6i Controller (Ultra320 SCSI, RAID, embedded)
Integrated Lights-Out (iLO) embedded
1 full length and 1 half length 64-bit/133 MHz PCI-X slots
1.44MB Diskette Drive
7 fans; N+1 fan redundancy
Rack (1U), (1.75 in/4.45 cm)
| |
| |
HP ProLiant DL360G4p
SAS Rack CTO Chassis (North America) |
389831-405 | Factory
Integrated Model ships with: |
|
Embedded NC7782
PCI-X Gigabit Server Adapter
Integrated Lights-Out (iLO)
embedded 1 full length and 1 half length 64-bit/133 MHz PCI-X slots 7
fans; N+1 fan redundancy Rack (1U), (1.75 in/4.45 cm) | |
|
Step 1A: If SAS Model, Choose SAS Starter Kit or Controller (only one of the following) |
SAS Controller |
HP Smart Array
P600/256 BBWC Controller
NOTE: This
is a required selection if one of the two following SAS Starter Kits is not selected.
If choosing this part number, 2.5" SAS hard drives must still be selected under
Step 4. | 337972-B21 |
SAS
Starter Kit | NOTE:
SAS Starter Kits are not compatible with the
SCSI or SATA models. |
| SAS
Starter Kit - 36GB
NOTE: Includes Smart Array P600/256
BBWC Controller and (2) 36GB SFF SAS Universal Hard Drives. |
396221-B21 |
SAS Starter Kit
- 72GB
NOTE: Includes Smart Array P600/256
BBWC Controller and (2) 72GB SFF SAS Universal Hard Drives. |
396220-B21 |
|
Step
3: Choose Additional Factory Integratable Options |
Diskette
Drive |
Slimline Ejectable
Floppy Drive
NOTE: This Diskette Drive is for
SAS (389831-405) models. |
390164-B21 |
1.44 MB Diskette
drive
NOTE: This
Diskette Drive is for SATA (382146-405) models |
354588-B21 |
Optical
Drive |
NOTE:
Optical Drives are OPTIONAL if choosing the (389831-405) SAS Rack CTO Chassis
Model or (382146-405) SATA Rack CTO Chassis Model in Step 1.
NOTE: An Optical Drive is REQUIRED if choosing the 382147-405 SCSI
Rack CTO Chassis Model in Step 1. |
|
Slimline DVD-ROM
Drive (8X/24X) Option Kit
NOTE: This DVD-ROM Drive (PN 264007-B21)
is for SAS and SCSI models. It is not supported in SATA models. |
|
Slimline CD-ROM
Drive 24X
NOTE: This CD-ROM Drive (PN 356963-B21)
is the only drive that will support SATA models.
|
|
Slimline CD-RW/DVD-ROM
Combo Option Kit
NOTE: This CD-RW/DVD-ROM Drive (PN
331903-B21) is for SAS and SCSI models. It is not supported in SATA models.
|
|
Power
Supply |
460W HP redundant
power supply with IEC cord only
NOTE: For SCSI and SATA Models.
|
|
535W HP redundant
power supply with IEC cord only
NOTE: For SAS Models. |
|
535W HP redundant
power supply with NEMA or Japan cord only
NOTE: for SAS Models. |
389830-001
|
|
Step
4: Choose Additional Options for Factory Integration |
NOTE:
For additional options, please refer to the "Options" section
below. |
Options
ProLiant
Essentials
Value Pack Software |
ProLiant Essentials
Intelligent Networking Pack |
|
ProLiant Essentials
Intelligent Networking Pack - Windows Edition, Single Server License
NOTE: For use with a single server.
Contains one license with a unique license activation key and documentation.
|
|
NOTE:
For additional ProLiant Intelligent Networking Pack License Kits please
see the QuickSpecs at: https://h18000.www1.hp.com/products/quickspecs/12062_div/12062_div.html |
|
ProLiant Essentials
Intelligent Networking Pack - Linux Edition, Single Server License |
436229-B21
|
NOTE:
For additional ProLiant Intelligent Networking Pack - Linux License Kits
please see the QuickSpecs at:
https://h18000.www1.hp.com/products/quickspecs/12327_div/12327_div.html
|
|
ProLiant Essentials
Performance Management Pack |
|
ProLiant Essentials
Performance Management Pack, Single-Server License
NOTE: For use with a single server.
Contains one license with a unique license activation key, HP Management
CD and documentation.
NOTE: The most recent version of the software can always be downloaded
at https://www.hp.com/products/pmp. |
|
NOTE:
For additional ProLiant Performance Management Pack License Kits please
see the QuickSpecs at: https://h18000.www1.hp.com/products/quickspecs/11925_div/11925_div.html
|
|
ProLiant Essentials
Rapid Deployment Pack Windows Edition Release |
|
Rapid Deployment
Pack, Single-Server License
NOTE: This license allows 1 server
to be deployed and managed via RDP. |
|
Rapid Deployment
Pack, Single-Server License (Japan)
NOTE: This license allows 1 server to be deployed and managed via
RDP. |
|
NOTE:
For additional ProLiant Essentials Rapid Deployment Pack License Kits please
see the QuickSpecs at: https://h18000.www1.hp.com/products/quickspecs/11053_div/11053_div.html
|
|
ProLiant Essentials
Workload Management Pack |
|
ProLiant Essentials
Workload Management Pack, Single Server License |
|
NOTE:
For additional ProLiant Workload Management Pack License Kits please see
the QuickSpecs at: https://h18000.www1.hp.com/products/quickspecs/11452_div/11452_div.html
|
|
ProLiant Essentials
Virtualization Management Software |
|
ProLiant Essentials
Virtual Machine Management Pack, Single-Server License
NOTE: For use with a single server.
Contains one license with a unique license activation key and documentation. |
435661-B21
|
ProLiant
Essentials Server Migration Pack, Single-Migration License
NOTE: Contains one license, enabling 1 server migration, with a unique
license activation key and documentation.
|
435663-B21
|
ProLiant Essentials
Server Migration Pack - Physical to ProLiant Edition, Single-Migration License |
412978-B21
|
NOTE:
This license allows 1 server to be migrated from a physical server to a
virtual machine. Or this license can be used to migrate a virtual machine
from one virtualization layer i.e. VMware GSX to a different virtualization
layer such as VMware ESX or Microsoft Virtual Server 2005. |
|
NOTE:
For additional ProLiant Essentials Virtualization Management Software License
Kits please see the QuickSpecs at: https://h18000.www1.hp.com/products/quickspecs/12328_div/12328_div.html |
|
ProLiant Essentials
Vulnerability and Patch Management Pack |
|
ProLiant Essentials
Vulnerability and Patch Management Pack, Single-Server License
NOTE: For use with a single server.
Contains one license with a unique license activation key and documentation.
|
371645-B21
|
NOTE:
For additional ProLiant Vulnerability and Patch Management Pack License
Kits, please see the QuickSpecs at: https://h18000.www1.hp.com/products/quickspecs/12111_div/12111_div.html
|
|
NOTE:
Flexible and volume quantity license kits are available for ProLiant Essentials
Value Packs. Refer to https://www.hp.com/servers/proliantessentials
or the various ProLiant Essentials Value Pack product QuickSpecs for more
information.
NOTE: For more information regarding ProLiant Essentials Software,
please see the following URL: https://www.hp.com/servers/proliantessentials. |
|
|
Remote Management |
Integrated Lights-Out Advanced
Pack |
|
Integrated Lights-Out Advanced
Pack, 1 server
Featuring: Sophisticated virtual administration features for ultimate
control of servers in the data centers and remote sites. |
|
NOTE: For additional
Integrated Light-Out Advanced Pack License Kits please see the QuickSpecs
at: https://h18000.www1.hp.com/products/quickspecs/11052_div/11052_div.html |
|
|
ProLiant Software
Maintenance Subscription |
ProLiant Software Maintenance
Subscription |
355060-B21
|
ProLiant Software Maintenance
Single Release |
356573-B21
|
ProLiant Foundation Pack Single
Release |
356604-B21
|
NOTE: Please see
the SmartStart QuickSpecs for additional information regarding the subscription
purchase:
https://h18000.www1.hp.com/products/quickspecs/division/11073.html
(Worldwide) |
|
|
Processor |
Intel Xeon 2.8 GHz/800MHz-2MB
110W Processor Option Kit
NOTE: This processor option kit (PN
399042-B21) supports the HP ProLiant DL360 G4p only. |
|
Intel Xeon 3.0 GHz/800MHz-2MB
110W Processor Option Kit
NOTE: This processor option kit (PN
380327-B21) supports the HP ProLiant DL360 G4p only. |
|
Intel Xeon 3.0 GHz/800MHz-2MB
55W Processor Option Kit, Low Voltage
NOTE: This processor option kit (PN
394921-B21) supports the HP ProLiant DL360 G4p only. |
|
Intel Xeon 3.2 GHz/800MHz-2MB
110W Processor Option Kit
NOTE: This processor option kit (PN
379817-B21) supports the HP ProLiant DL360 G4p only. |
|
Intel Xeon 3.4 GHz/800MHz-2MB
110W Processor Option Kit
NOTE: This processor option kit (PN
376243-B21) supports the HP ProLiant DL360 G4p only. |
|
Intel Xeon 3.6 GHz/800MHz-2MB
110W Processor Option Kit
NOTE: This processor option kit (PN
376242-B21) supports the HP ProLiant DL360 G4p only. |
|
Intel Xeon 3.8 GHz/800MHz-2MB
110W Processor Option Kit
NOTE: This processor option kit (PN
376241-B21) supports the HP ProLiant DL360 G4p only. |
|
|
Memory
(DIMMs)
|
1 GB Advanced
ECC PC2-3200 DDR2 SDRAM DIMM Memory Kit (2 x 512 MB)
|
|
2 GB Advanced
ECC PC2-3200 DDR2 SDRAM DIMM Memory Kit (2 x 1 GB)
|
|
4 GB Advanced
ECC PC2-3200 DDR2 SDRAM DIMM Single Rank Memory Kit (2 x 2 GB)
|
|
4 GB Advanced ECC PC2-3200 DDR2
SDRAM DIMM Dual Rank Memory Kit (2 x 2 GB) |
|
|
Hard Drives |
Ultra320 – Hot Plug
NOTE: The HP ProLiant DL360 G4p SCSI
models support U320 Universal Hot Plug drives. |
|
HP 300GB U320 10K Universal HDD |
|
HP 146GB U320 10K Universal HDD |
|
HP 72GB U320 10K Universal HDD |
|
HP 300GB U320 15K Universal HDD
|
|
HP 146GB U320 15K Universal HDD |
|
HP 72GB U320 15K Universal HDD |
|
HP 36GB U320 15K Universal HDD |
|
NOTE: Please see
the Hard Drive QuickSpecs for Technical Specifications such as capacity,
height, width, interface, transfer rate, seek time, physical configuration,
and operating temperature:
https://h18000.www1.hp.com/products/quickspecs/11531_div/11531_div.html
(Worldwide) |
|
Serial-ATA
(SATA) Hot Plug Hard Drive (For use with SATA Models)
NOTE: The HP embedded 2 Port SATA controller does not support RAID,
hot plug drive functionality or drive activity LEDs.
|
|
HP 750GB 1.5G SATA 7.2K 3.5"
HDD
|
|
HP 500GB 1.5G SATA 7.2K 3.5"
HDD |
|
HP 250GB 1.5G SATA 7.2K 3.5"
HDD |
|
HP 160GB 1.5G SATA 7.2K 3.5"
HDD |
|
HP 80GB 1.5G SATA 7.2K 3.5"
HDD |
|
SFF SATA Hot Plug
|
|
HP 60GB 1.5G SATA 5.4K SFF HDD |
|
NOTE: SATA drives have a 1-year warranty. Please see the SATA
Hard Drive QuickSpecs for Technical Specifications such as capacity, height,
width, interface, transfer rate, seek time, physical configuration, and
operating temperature:
https://h18000.www1.hp.com/products/quickspecs/11940_div/11940_div.html
(Worldwide)
|
|
Serial Attached SCSI (SAS)
SFF Hot Plug (For use with SAS Models) |
|
HP 146GB 3G SAS 10K SFF SP HDD
|
|
HP 72GB 3G SAS 10K SFF SP HDD
|
|
HP 36GB 3G SAS 10K SFF SP HDD
|
|
NOTE: All SFF
SAS Universal Hard Drives are supported ONLY by HP ProLiant DL360 G4p SAS
models.
NOTE: Please see the SAS Hard Drive QuickSpecs for Technical Specifications
such as capacity, height, width, interface, transfer rate, seek time, physical
configuration, and operating temperature:
https://h18000.www1.hp.com/products/quickspecs/12224_div/12224_div.html
(Worldwide)
|
|
|
Communications |
HP NC150T PCI 4-port Gigabit 1000T
Combo Switch Adapter |
|
HP NC310F PCI-X 1000SX Gigabit
Server Adapter |
|
HP NC320T PCI Express 1000T Gigabit
Server Adapter |
|
HP NC360T PCI Express Dual Port
Gigabit Server Adapter |
|
HP NC373F PCI Express Multifunction
Gigabit Server Adapter
|
|
HP NC373T PCI Express Multifunction
Gigabit Server Adapter |
|
HP NC380T PCI Express Dual Port
Multifunction Gigabit Server Adapter |
|
HP NC510F PCIe 10 Gigabit Server
Adapter
NOTE: A minimum of 1 gigabyte (1
GB) of server memory is required per each NC510F adapter.
|
|
HP NC510C PCIe 10 Gigabit Server
Adapter
NOTE: A minimum of 1 gigabyte (1
GB) of server memory is required per each NC510C adapter.
|
|
HP NC1020 PCI 1000T Gigabit Server
Adapter |
|
HP NC7771 PCI-X 1000T Gigabit
Server Adapter |
|
NOTE: Any NIC
(except the NC1020) on the option list can be used for redundancy with the
embedded NC7782 Dual Port Network Controller. When teaming with other NICs
or with the embedded NIC, the lack of Jumbo Frames and LSO features on the
NC1020 will cause high end NICs to have those features disabled. (e.g. incompatibility
issues with the other option NICs for that platform). |
|
HP IB 4X SDR PCI-e single PORT
HCA
|
|
HP IB 4X DDR PCI-e Single PORT
HCA |
|
|
Management Options
|
Remote Insight Lights-Out Edition
II (NA, LA) |
227251-001
|
Remote Insight Lights-Out Edition
II (EMEA) |
227251-021
|
Remote Insight Lights-Out Edition
II (ROW) |
227251-371
|
|
Tape Drives |
NOTE: For
the complete listing of Tape Drive offerings, please see:
https://www.hp.com/products1/storage/compatibility/tapebackup/ISS/index.html
For recommended tape drive offerings for this ProLiant server see
the following:
|
|
USB Tape Drives |
|
HP StorageWorks DAT 72 USB
Internal Tape Drive (Carbonite)
NOTE: HP recommends combining
this tape drive with the 1U USB Rack-Mount kit ( A8007A) for a complete
rack-mount solution. |
DW026A
|
Ultrium Tape Drives |
|
HP StorageWorks Ultrium
232 Internal Tape Drive (Carbonite)
NOTE: HP recommends combining
this tape drive with the 1U SCSI Rack-Mount kit ( A7445B) for a complete
rack-mount solution.
|
|
HP StorageWorks 3U SCSI
Rack-mount kit with one Ultrium 460 (Carbon)
|
350546-B22
|
HP StorageWorks 1U SCSI
Rack-mount kit with one Ultrium 448 SCSI Tape Drive (Carbonite) |
DW028B
|
HP StorageWorks 1U SCSI
Rack-mount kit with one Ultrium 920 |
EH903A
|
HP StorageWorks 3U SCSI
Rack-mount kit with one Ultrium 960 (Carbonite) |
Q1595B
|
NOTE: Please
see the HP StorageWorks Ultrium Tape Drive QuickSpecs for additional
options such as controllers, media, and other related items:
https://h18006.www1.hp.com/products/quickspecs/11739_div/11739_div.html
(Worldwide)
https://h18006.www1.hp.com/products/quickspecs/12128_div/12128_div.html
(Worldwide)
|
|
For
an up-to-date listing of the latest O/S and software support details
for HP Ultrium tape drives, please visit: https://www.hp.com/go/connect |
|
Rack-Mount Tape Drive
Enclosures |
|
HP StorageWorks 1U Rack-Mount
Kit
NOTE: The 1U Rack-Mount Kit
can support up to (2) half-height tape drives and is compatible with
multiple Single-Ended and LVD SCSI tape drives including the DAT 24,
DAT 40, DAT 72, DLT VS80, DLT VS160, Ultrium 215, Ultrium 232, Ultrium
448 and Ultrium 920 tape drives. |
|
HP StorageWorks 1U USB Rack-Mount
Kit
NOTE: The 1U USB Rack-Mount
Kit can support up to (2) half-height tape drives and is compatible
with the DAT 24 USB, DAT 40 USB and DAT 72 USB tape drives. |
|
HP
StorageWorks 3U Rack-Mount Kit
NOTE: The 3U Rack-mount Kit can support up to (2) full-height
or (4) half-height tape drives and compatible with multiple LVD SCSI
tape drives including DAT 40, DAT 72, DLT VS160, SDLT 320, SDLT 600,
Ultrium 232, Ultrium 460, Ultrium 448, Ultrium 920 and Ultrium 960
tape drives. |
274338-B22
|
NOTE: Please
see the Rack-Mount Tape Drive Kits QuickSpecs for additional information
regarding these kits:
https://h18000.www1.hp.com/products/quickspecs/10854_div/10854_div.html
(Worldwide)
|
|
|
|
Tape Autoloaders
|
HP StorageWorks DAT Autoloader |
|
HP StorageWorks DAT 72x10 tape
autoloader |
AE313A |
HP StorageWorks 1/8 Tape Autoloader |
|
HP StorageWorks 1/8 Ultrium 920
G2 Tape Autoloader |
AH165A |
HP StorageWorks 1/8 Ultrium 448
G2 Tape Autoloader |
AH164A |
HP StorageWorks 1/8 Ultrium 232
G2 Tape Autoloader |
AH163A |
HP StorageWorks 1/8 G2 Tape Autoloader
Rack Kit
NOTE: Required to install the 1/8
G2 Autoloaders in a standard 19-inch rack; includes rails and rackmount
instructions |
AH166A |
NOTE: Please reference
the Tape Autoloader QuickSpecs at https://www.hp.com/go/automation
for additional information needed to create a complete solution; reference
current compatibility information at https://www.hp.com/go/ebs. |
|
|
Power Cords
|
NOTE: The HP ProLiant
DL360 G4p ships with an IEC-IEC power cord used for rack mounting with Power
Distribution Units (PDUs). For stand-alone deployments or installation without
a rack, country-specific power cord options are available. U.S. & Japan
models will ship with two power cords: IEC-IEC (142257-002) and North American
C13-Nema 5-15P (103541-001) cords. |
|
Power Cord, Euro, 10A 250 V Straight
(12 ft/3.7 m) |
157215-021
|
Power Cord, UK, 10A 250 V Straight
(12 ft/3.7 m) |
157216-031
|
Power Cord, Danish, 10A 250 V
Straight (12 ft/3.7 m) |
157218-081
|
Power Cord, Swiss, 10A 250 V Straight
(12 ft/3.7 m) |
157219-111
|
Power Cord, Italian, 10A 250 V
Straight (12 ft/3.7 m) |
157217-061
|
Power Cord, South Africa, 10A
250 V Straight (12 ft/3.7 m) |
157220-AR1
|
|
HP StorageWorks Modular
Smart Array 20 |
HP StorageWorks Modular Smart
Array 20
NOTE: Rack-mountable 12 (SATA) drive
enclosure with U320 Host connectivity, redundant power supplies.
|
335921-B21 |
HP StorageWorks Modular Smart
Array 20 Starter Kit
NOTE: Rack-mountable 12 (SATA) drive
enclosure with U320 Host connectivity, redundant power supplies. Includes
Smart Array 6402/128 Controller.
|
366172-B21 |
NOTE: The Modular Smart Array Enclosure 20 Family
supports the SATA 1.5Gb/s 3.5”
Hot Plug
Hard Drives. |
|
|
HP StorageWorks Modular
Smart Array 30 |
HP StorageWorks Modular Smart
Array 30 SB
NOTE: Rack-mountable 14 drive enclosure
with single bus, redundant power supplies |
302969-B21 |
HP StorageWorks Modular Smart
Array 30 DB
NOTE: Rack-mountable 14 drive enclosure
with dual bus, redundant power supplies
|
302970-B21 |
NOTE: The
Modular Smart Array Enclosure 30 Family supports the Wide Ultra3, Ultra320
Hot Plug Hard Drives. |
|
|
HP StorageWorks Modular Smart Array 500 |
HP StorageWorks Modular Smart Array 500 Generation 2 |
335880-B21 | NOTE:
Please see the Modular Smart Array 500 Generation 2 QuickSpecs for additional
information including configuration steps and additional options needed for a
complete solution at: https://h18000.www1.hp.com/products/quickspecs/11956_div/11956_div.html
(Worldwide) | |
|
HP StorageWorks
Modular Smart Array 1500 cs |
Modular Smart Array 1500 Controller
Shelf |
AA986A
|
NOTE: Please see
the StorageWorks Modular SAN Array 1500 cs QuickSpecs for additional options
and configuration information at:
https://www.hp.com/go/MSA1500cs |
|
|
StorageWorks Options |
NOTE: The following
is a list of all Fibre Channel Host Bus Adapters for Windows, Linux and
Netware. For detailed compatibility information please see:
https://h18006.www1.hp.com/storage/saninfrastructure/hba.html
|
|
HP StorageWorks FC2142SR 4Gb PCI-e
HBA
|
|
HP StorageWorks FC2242SR Dual
Channel 4 Gb PCI-e HBA
|
|
HP StorageWorks FC1142SR 4Gb PCI-e
HBA
|
|
HP StorageWorks FC1242SR Dual
Channel 4 Gb PCI-e HBA
|
|
HP StorageWorks FC2143 4Gb PCI-X
2.0 -to-Fibre Channel HBA
|
|
HP StorageWorks FC2243 Dual Channel
4Gb PCI-X 2.0 HBA
|
|
HP StorageWorks FC1143 4Gb PCI-X
2.0 HBA
|
|
HP StorageWorks FC1243 Dual Channel
4Gb PCI-X 2.0 HBA
|
|
|
Uninterruptible Power
Systems – Rack Mountable |
HP, R1.5kVA UPS, 1U, NA |
AF419A
|
HP, R1.5kVA UPS, 1U, INTL |
AF418A
|
HP, R1.5kVA UPS, 1U, JPN/TW |
AF421A
|
HP R3000 VA UPS, 2U, DTC, INTL
NOTE: Replaces non-RoHs compliant
part numbers 192186-B31, 192186-B32, 192186-B33, 192186-AR1.
|
AF414A
|
HP R3000 VA UPS, 2U, L5-30, NA
NOTE: Replaces non-RoHs compliant part number 192186-001.
|
AF422A
|
HP R3000 VA UPS, 2U, L6-20, NA
NOTE: Replaces non-RoHs compliant
part number 192186-002.
|
AF423A
|
HP R3000 VA UPS, 2U, L6-20, JPN
NOTE: Replaces non-RoHs compliant
part number 192186-292.
|
AF424A
|
HP R3000 VA UPS, 2U, L5-30, JPN
NOTE: Replaces non-RoHs compliant
part number 192186-291.
|
AF425A
|
HP R5500 VA UPS, INTL
NOTE: Replaces non-RoHs compliant
part number 326529-B31. |
AF416A
|
HP R5500 VA UPS, NA/JPN
NOTE: Replaces non-RoHs compliant
part number 326529-D71.
|
AF426A
|
|
HP Monitored Power
Distribution Unit (PDU) |
HP Monitored Power Distribution
Unit: Full Rack Version |
|
HP 17.3 kVA S2324 Monitored PDU-
dual input, 3U, 24A (NA/JPN)
NOTE: Replaces non-RoHs compliant
part number 370959-D71. |
AF503A
|
HP 8.3 kVA S1324 Monitored PDU-
single input, 3U, 24A (NA/JPN)
NOTE: Replaces non-RoHs compliant
part number 370960-D71.
|
AF504A
|
HP 16.6 kVA S2140 Monitored PDU-
dual input, 1U, 40A (NA/JPN)
NOTE: Replaces non-RoHs compliant
part number 37061-D71.
|
AF505A
|
HP 8.6 S1140 Monitored PDU- single
input, 1U, 40A (NA/JPN)
NOTE: Replaces non-RoHs compliant
part number 370962-D71.
|
AF506A
|
HP 22.1 kVA S2316 Monitored PDU-
dual input, 3U, 16A (INTL)
NOTE: Replaces non-RoHs compliant
part number 370963-B31.
|
AF507A
|
HP 11 kVA S1316 Monitored PDU-
single input, 3U, 16A (INTL)
NOTE: Replaces non-RoHs compliant
part number 370964-B31.
|
AF508A
|
HP 14.7 kVA S2132 Monitored PDU-
dual input, 1U, 32A (INTL)
NOTE: Replaces non-RoHs compliant
part number 370965-B31.
|
AF509A
|
HP 7.3kVA S1132 Monitored PDU-
single input, 1U, 32A (INTL)
NOTE: Replaces non-RoHs compliant
part number 370966-B31.
|
AF510A
|
|
Modular PDUs 1U/0U (Up
to 32 outlets) NOTE: 1U/0U
mounting brackets shipped with the unit (optimized for 10000 and 9000 series
racks). | Fixed Cord
Extension Bars NOTE: Two extension
bar sticks; each with (7) C13 plugs. |
351655-B21 | Fixed
Cord PDU (NA/JPN) NOTE: Four Fixed
Cord Extension Bars, and one 24A, HV mPDU L6-30P core. |
351655-D72 | Fixed
Cord PDU (INTL) NOTE: Four Fixed Cord
Extension Bars, and one 32A, HV mPDU IEC-309 core. |
351655-B31 | HP
Modular Power Distribution Units (mPDU), Low Volt Model, 24A (100-127 VAC) (NA,
Japan) NOTE: This mPDU ( 252663-D71)
may also be used to connect the low volt model of the UPS R3000 XR. |
|
HP Modular Power Distribution Units (mPDU), High Volt Model, 24A (200-240 VAC)
(NA, Japan) | 252663-D72
|
HP Modular Power Distribution
Units (mPDU), High Volt Model, 32A (200-240 VAC) (Int’l) |
252663-B31 |
HP Modular Power Distribution Units (mPDU), High Volt Model, 40A (200-240 VAC)
(WW) NOTE: This mPDU ( 252663-B21),
40A model has a hardwired input. |
252663-B21
|
HP Modular Power Distribution Unit(mPDU), High Volt Model, 16A (200-240 VAC)
(WW) | 252663-B24
|
HP Modular Power Distribution
Unit (mPDU), High Volt Model, 40A, Attached Cord, (NA/JPN) |
252663-D73 | HP
Modular Power Distribution Unit (mPDU), High Volt Model, 40A, Attached Cord, (Int'l)
| 252663-B32 |
NOTE: This PDU
has a detachable input power cord and allows for adaptability to country specific
power requirements. This model may also be used with the high volt UPSs R3000
XR and R6000 For North America, need to order cable PN 340653-001. |
| NOTE:
Please see the following Modular Power Distribution Unit (Zero-U/1U Modular
PDUs) QuickSpecs for additional options including shorter jumper cables and country
specific power cords: https://h18000.www1.hp.com/products/quickspecs/11041_div/11041_div.html
(Worldwide) | |
|
USB Options |
HP USB 2-Button Optical Scroll
Mouse (Carbonite/Silver) |
|
HP USB 04 Standard Keyboard |
DT528A#xxx
|
USB 2.0 4-port HUB
|
DG954A
|
HP 1GB Drive Key II- USB 2.0 Flash
Drive
|
AG382AA
|
HP 512MB DriveKey II- USB Flash
Drive |
ED516AA
|
|
HP ProLiant DL360
G4p Deployment Options |
460W HP redundant power supply
with IEC cord only |
|
460W HP redundant power supply
with US or Japanese NEMA cord only
NOTE: The HP ProLiant DL360 G4p ships
with a single IEC-IEC power cord used for rack mounting with Power Distribution
Units (PDUs). For stand-alone deployments or installation without a rack,
country-specific power cord options are available. U.S., Japan, & APD
models ship with two power cords: IEC-IEC and NEMA cords.
|
|
535W HP redundant power supply
with IEC cord only
|
|
535W HP redundant power supply
with US or Japanese NEMA cord only
NOTE: The HP ProLiant DL360 G4p ships
with an IEC-IEC power cord used for rack mounting with Power Distribution
Units (PDUs). For stand-alone deployments or installation without a rack,
country-specific power cord options are available. U.S., Japan, & APD
models ship with two power cords: IEC-IEC and NEMA cords. |
389830-001
|
|
Rack Kits |
1U Cable Management Arm
NOTE: Package contains two cable
management arms. |
365403-B21
|
|
HP Rack 10000 G2 Series
(Carbon/Graphite Metallic)
|
10642 G2 (42U) Rack Cabinet -
Pallet |
|
10642 G2 (42U) Rack Cabinet -
Shock Pallet |
|
10642 G2 (42U) Rack Cabinet -
Crated |
AF003A
|
10642 G2 (42U) Rack Cabinet, with
Extension - Shock Pallet |
|
10636 G2 (36U) Rack Cabinet -
Pallet |
|
10636 G2 (36U) Rack Cabinet -
Shock Pallet |
|
10636 G2 (36U) Rack Cabinet -
Crated |
|
10636 G2 (36U) Rack Cabinet, with
Extension - Shock Pallet |
|
NOTE: It is mandatory
to use a shock pallet when shipping racks with equipment installed. |
|
NOTE: Please see
the Rack 10000 G2 QuickSpecs for Technical Specifications such as height,
width, depth, weight, and color:
https://h18000.www1.hp.com/products/quickspecs/12402_div/12402_div.html
(Worldwide) |
|
NOTE: For additional
information regarding Rack Cabinets, please see the following URL: https://www.hp.com/go/rackandpower. |
|
|
HP Rack 10000 Series
(Graphite Metallic)
|
10642 (42U) Infrastructure Rack
(Low Voltage) |
379006-001
|
10642 (42U) Infrastructure Rack
(High Voltage) |
|
HP Rack S10614 (14U) Rack Cabinet
- Shock Pallet |
|
HP Rack 10842 (42U, 800mm wide)
– Pallet |
257415-B21
|
HP Rack 10842 (42U, 800mm wide)
– Shock Pallet |
257415-B22
|
HP Rack 10647 (47U) – Pallet |
245160-B21
|
HP Rack 10647 (47U) – Crated |
245160-B23
|
HP Rack 10622 (22U) – Pallet |
245163-B21
|
HP Rack 10622 (22U) – Shock Pallet |
245163-B22
|
HP Rack 10622 (22U) – Crated |
245163-B23
|
NOTE: xxxxxx-B21 (pallet) used to ship
empty racks shipped on a truck. -B22 (shock pallet) used to ship racks
with equipment installed (by custom systems, VARs and Channels). xxxxxx-B23
(crated) used for air shipments of empty racks.
|
|
NOTE: It is mandatory to use
a shock pallet in order to ship racks with equipment installed. Not all
HP equipment is qualified to be shipped in the Rack 10000 series
|
|
NOTE: Please see the Rack 10000
QuickSpecs for Technical Specifications such as height, width, depth,
weight, and color:
https://h18000.www1.hp.com/products/quickspecs/10995_div/10995_div.html
(Worldwide)
|
|
NOTE: For additional information regarding
Rack Cabinets, please see the following URL: https://www.hp.com/go/rackandpower
|
|
|
Keyboards and Monitors | TFT7210R
Rack Mounted 17" Monitor NOTE:
For a complete list of Monitors please view the following URL: https://www.hp.com/go/kvm
| |
TFT7600 Rackmount Keyboard Monitor
US | |
TFT7600 Rackmount Keyboard Monitor
UK | AG053A |
TFT7600 Rackmount Keyboard Monitor
GR | AG054A |
TFT7600 Rackmount Keyboard Monitor
FR | AG055A |
TFT7600 Rackmount Keyboard Monitor
IT | AG056A |
TFT7600 Rackmount Keyboard Monitor
SP | AG057A |
TFT7600 Rackmount Keyboard Monitor
DEN | AG058A |
TFT7600 Rackmount Keyboard Monitor
NOR | AG059A |
TFT7600 Rackmount Keyboard Monitor
SE/FI | AG060A |
TFT7600 Rackmount Keyboard Monitor
SWI | AG061A |
TFT7600 Rackmount Keyboard Monitor
PORT | AG062A |
TFT7600 Rackmount Keyboard Monitor
BEL | AG063A |
TFT7600 Rackmount Keyboard Monitor
JPN2 | AG064A |
TFT7600 Rackmount Keyboard Monitor
RUS | AG065A |
TFT7600 Rackmount Keyboard Monitor
INTL | AG066A | 1U
Rackmount Keyboard with USB, US | | 1U
Rackmount Keyboard with USB, UK | AG073A | 1U
Rackmount Keyboard with USB, GR | AG074A | 1U
Rackmount Keyboard with USB, FR | AG075A | 1U
Rackmount Keyboard with USB, ITL | AG076A | 1U
Rackmount Keyboard with USB, SP | AG077A | 1U
Rackmount Keyboard with USB, DEN | AG078A | 1U
Rackmount Keyboard with USB, NOR | AG079A | 1U
Rackmount Keyboard with USB, SE/FI | AG080A | 1U
Rackmount Keyboard with USB, SWI | AG081A | 1U
Rackmount Keyboard with USB, PORT | AG082A | 1U
Rackmount Keyboard with USB, BEL | AG083A | 1U
Rackmount Keyboard with USB, JPN2 | AG084A | 1U
Rackmount Keyboard with USB, RUS | AG085A | 1U
Rackmount Keyboard with USB, INTL | AG086A |
NOTE: For additional
information regarding Rack Options, please see the following URL: https://www.hp.com/go/rackandpower |
|
|
HP KVM Switch Options
|
2x1x16 IP Console Switch with
Virtual Media |
|
4x1x16 IP Console Switch with
Virtual Media |
|
2x16 Server Console Switch with
Virtual Media |
|
PS/2 Virtual Media Interface Adapter,
1 pack
NOTE: Requires PS/2 and one USB port
on server. |
|
Server Console Switch (KVM), 0
x 1 x 8 port |
|
Server Console Switch (KVM), 0
x 2 x 16 port |
|
PS/2 Interface Adapter, 1 pack
|
|
PS/2 Interface Adapter, 8 pack
|
|
USB Interface Adapter, 1 pack
|
|
Serial Interface adapter - 1 Pack
with power supply |
|
NOTE: Cat5e cables
are required to connect Interface Adapters to Console Switches. Cat5e cables
can be found at the following URL: https://www.hp.com/go/kvm.
|
|
HP 1x 4 USB/PS2 KVM Switch, TT
(NA/JPN) |
371301-D71
|
HP 1x 4 USB/PS2 KVM Switch, TT
(AU/NZ) |
371301-011
|
HP 1x 4 USB/PS2 KVM Switch, TT
(UK) |
371301-031
|
HP 1x 4 USB/PS2 KVM Switch, TT
(EU) |
371301-A21
|
HP 1x 4 USB/PS2 KVM Switch, RM
(ALL) |
371302-B21
|
HP PS2 KVM Cable with audio, 6',
2-pack |
371730-B21
|
HP USB KVM Cable with audio, 6',
2-pack |
371729-B21
|
NOTE: For additional
information regarding KVM switches, Serial Console servers, rack mount monitors,
keyboards and all related options please see the following URL: https://www.hp.com/go/kvm.
|
|
|
HP Serial Console Server Options
|
HP 16 Port
Serial Console Server (worldwide)
|
|
HP 48 Port
Serial Console Server (worldwide)
|
|
Serial
Adapter, RJ45-DB9 DCE Female, 1 Pack
|
|
Serial
Adapter, RJ45-DB9 DCE Female, 8 Pack
|
AF110A
|
NOTE: Cat5e cables
are required to connect Serial Adapters to Serial Console Servers. Additional
Serial Adapters and Cat5e cables can be found at the following URL: https://www.hp.com/go/kvm. |
|
NOTE: For additional
information regarding KVM switches, Serial Console servers, rack mount monitors,
keyboards and all related options please see the following URL: https://www.hp.com/go/kvm. |
|
|
Service
and Support Offerings (HP Care Pack Services) |
Hardware Services
4-Hour On-site Service |
|
4-Hour On-site Service,
5-Day x 13-Hour Coverage, 3 Years, Electronic |
U4496E
|
4-Hour On-site Service,
7-Day x 24-Hour Coverage, 3 Years, Electronic |
U4497E
|
Hardware Services
6-Hour Call to Repair On-site Service |
|
6-Hour Call to Repair, On-site
Service, 7-Day x 24-Hour Coverage, 3 Years, Electronic |
U4498E
|
Hardware Services
Next Business Day On-Site Service |
|
Hardware Installation, Electronic |
U4506E
|
Installation & Start-Up
of a ProLiant server and Microsoft or Linux O/S per the Customer Description
and/or Data Sheet. To be delivered on a scheduled basis 8am-5pm, M-F,
excl. HP holidays, Electronic |
U4507E
|
Support Plus |
|
Onsite HW support, 8am-9pm,
M-F, 4hr response and Microsoft O/S SW Tech support offsite, onsite
at HP's discretion, 8am-9pm, M-F 2hr response time excl. HP holidays,
Electronic |
U4508E
|
Support Plus 24 |
|
Onsite HW support 24x7,
4hr response and Microsoft O/S SW Tech support offsite, onsite at
HP's discretion, 24x7 2hr response time incl. HP holidays, Electronic |
U4509E
|
Onsite HW support 24x7,
4hr response and SuSE Linux SW Tech support offsite, onsite at HP's
discretion, 24x7 2hr response time incl. HP holidays, Electronic |
U6310E
|
Onsite HW support 24x7,
4hr response and Red Hat ES Linux SW Tech support offsite, onsite
at HP's discretion, 24x7 2hr response time incl. HP holidays, Electronic |
U8332E
|
NOTE:
For more information, customer/resellers can contact https://www.hp.com/services/carepack. |
|
|
Memory
NOTE:
Memory configurations listed do not apply to "Factory Integrated Models". |
HP ProLiant DL360 G4p Standard Models
|
Standard Memory
1 GB PC2-3200 DDR2 400 Registered SDRAM DIMM installed (2 x 512 MB SDRAM
DIMM)
Upgrading Memory
and Memory Interleaving
When upgrading memory, DIMMs 1A and 2A must match. DIMMs 3B and 4B, and
DIMMs 5C and 6C must match and must be installed as a pair. When DIMMs
1A and 2A are populated the system is automatically configured for 2:1
interleaving. When four or six DIMMs are populated with identical DIMMs
the system is automatically configured for bank interleaving.
Standard Memory Plus
Optional Memory
Up to 9 GB memory is available with the standard memory of 1 GB and the
optional installation of PC2-3200 DDR2 400 Registered SDRAM DIMM memory
kits.
Standard Memory Replaced with Optional Memory
Up to 12 GB of memory is available with the removal of the standard 512
MB of memory and the optional installation of PC2-3200 DDR2 400 Registered
SDRAM DIMM memory kits.
NOTE: Chart
does not represent all possible configurations.
|
Memory
|
Slot |
|
1 |
2 |
3 |
4 |
5 |
6 |
Standard |
1 GB |
512 MB
|
512 MB
|
Empty
|
Empty
|
Empty
|
Empty
|
Optional |
9 GB |
512 MB
|
512 MB
|
2 GB
|
2 GB
|
2 GB
|
2 GB
|
Maximum |
12 GB |
2 GB
|
2 GB
|
2 GB
|
2 GB
|
2 GB
|
2 GB
|
NOTE: In the online spare configuration,
the ROM automatically configures the last populated bank as the spare memory.
If only banks A and B are populated, bank B is the spare bank. If banks
A, B, and C are populated, bank C is the spare bank, Online spare memory
is configured through RBSU.
|
HP ProLiant DL360 G4p RPS Models
|
Standard Memory
2 GB PC3200 DDR 400 Registered SDRAM DIMM installed (2 x 1 GB SDRAM DIMM)
Upgrading Memory and Memory Interleaving
When upgrading memory, DIMMs 1A and 2A must match. DIMMs 3B and 4B, and
DIMMs 5C and 6C must match and must be installed as a pair. When DIMMs
1A and 2A are populated the system is automatically configured for 2:1
interleaving. When four or six DIMMs are populated with identical DIMMs
the system is automatically configured for bank interleaving.
Standard Memory Plus Optional Memory
Up to 10 GB memory is available with the standard memory of 2 GB and the
optional installation of PC2-3200 DDR2 400 Registered SDRAM DIMM memory
kits.
Standard Memory Replaced with Optional Memory
Up to 12 GB of memory is available with the removal of the standard 1
GB of memory and the optional installation of PC2-3200 DDR2 400 Registered
SDRAM DIMM memory kits.
NOTE: Chart does
not represent all possible configurations.
|
DL360 G4p Memory
|
Slot
|
|
1
|
2
|
3
|
4 |
5 |
6
|
Standard
|
2 GB |
1 GB
|
1 GB
|
Empty
|
Empty
|
Empty
|
Empty
|
Optional
|
10 GB |
1 GB
|
1 GB
|
2 GB
|
2 GB
|
2 GB
|
2 GB
|
Maximum
|
12 GB |
2 GB
|
2 GB
|
2 GB
|
2 GB
|
2 GB
|
2 GB
|
NOTE: In the online spare configuration,
the ROM automatically configures the last populated bank as the spare memory.
If only banks A and B are populated, bank B is the spare bank. If banks
A, B, and C are populated, bank C is the spare bank, Online spare memory
is configured through RBSU.
|
| |
Following are memory options
available from HP: |
| - 1 GB Advanced
ECC PC2-3200 DDR2 SDRAM DIMM Memory Kit (2 x 512 MB)
| 343055-B21 |
- 2 GB Advanced ECC PC2-3200
DDR2 SDRAM DIMM Memory Kit (2 x 1 GB)
| 343056-B21 |
- 4 GB Advanced ECC PC2-3200
DDR2 SDRAM DIMM Single Rank Memory Kit (2 x 2 GB)
| 343057-B21 |
- 4 GB Advanced ECC PC2-3200
DDR2 SDRAM DIMM Dual Rank Memory Kit (2 x 2 GB)
| 375004-B21 |
|
NOTE:
Online Spare Memory is not supported when using 2-rank DIMMs. A total of 8 ranks
are supported on the HP ProLiant DL360 G4p, A maximum of 4, 2-rank DIMMs can be
populated. If you plan to mix DIMM types, 2-rank DIMMs must be installed in the
first bank, 1 rank DIMMs can then be installed in subsequent banks. The following
is the memory population rules for the HP ProLiant ProLiant DL360 G4p. Key:
S denotes single rank kit, D denotes Dual rank kit, and X denotes no install. |
Bank A |
Bank B |
Bank C |
NOTES: |
S | X |
X | |
S |
S | X |
|
S | S |
S | |
D |
X | X |
Online spare not supported |
D | S |
X | Online
spare not supported |
D | S |
S | Online
spare not supported |
D | D |
X | Online
spare not supported |
Storage
 |
1,0 | Two Ultra320 Hot Pluggable
Hard Drive Bays; SATA model also available |
A | 1.44-MB Diskette Drive (removeable) |
B |
Low-Profile 24x IDE CD-ROM (ejectable) |
| |
 |
1,2,3,4 |
Four SFF Serial Attached SCSI
Hot Pluggable Hard Drive Bays |
A | Multibay: Slimline 24x CD-ROM
(ejectable) | | |
|
|
|
Drive Support - SAS Models
|
|
|
Quantity
Supported
|
Position
Supported
|
Controller
|
Removable Media
|
|
|
|
Slimline 1.44-MB Diskette Drive
|
Up to 1
|
A
|
Integrated |
Slimline 24x IDE CD-ROM Drive
|
Up to 1
|
A
|
Integrated IDE |
Slimline DVD-Rom Drive (8x/24x)
Option Kit (Servers) |
Up to 1
|
A
|
Integrated IDE |
|
|
Drive Support - SCSI
Models |
|
|
Quantity
Supported
|
Position
Supported
|
Controller
|
Removable Media
|
|
|
|
1.44-MB Diskette Drive
|
Up to 1
|
A
|
Integrated |
Slimline 24x IDE CD-ROM Drive
|
Up to 1
|
B
|
Integrated IDE |
Slimline DVD-Rom Drive (8x/24x)
Option Kit (Servers) |
Up to 1
|
B
|
Integrated IDE |
|
DL360 G4p Hard Drives |
Ultra320 Hot Pluggable Drives
NOTE: The HP ProLiant DL360
G4p only supports U320 Universal drives. |
|
Quantity
Supported
|
Position
Supported
|
Controller |
300GB U320 10K
146GB U320 10K
72GB U320 10K
300GB U320 15K
146GB U320 15K
72GB U320 15K
36GB U320 15K
|
Up to 2
|
0-1
|
Smart Array 6i Controller (integrated
on system board)
NOTE: The HP ProLiant DL360 G4p does
not offer an external SCSI port.
Smart Array 6402/128 Controller
Smart Array 6404/256 Controller
Smart Array 642 Controller
64-Bit/133-MHz Single Channel Ultra320 SCSI HBA G2 |
|
SFF SAS Hard Drive |
|
Quantity
Supported
|
Position
Supported
|
Controller |
146GB 3G SAS 10K SP
72GB 3G SAS 10K SP
36GB 3G SAS 10K SP
|
4
|
1-4
|
HP Smart Array P600/256 BBWC
Controller |
|
Serial-ATA (SATA) Hard Drive
NOTE: The HP embedded 2 Port
SATA controller does not support RAID, hot plug drive functionality or drive
activity LEDs. |
|
Quantity
Supported
|
Position
Supported
|
Controller
|
700GB 1.5G SATA 7.2K 500GB 1.5G
SATA 7.2K 250GB 1.5G SATA 7.2K 160GB 1.5G SATA 7.2K
80GB 1.5G SATA 7.2K
|
Up to 2
|
0-1
|
HP embedded 2 Port SATA Controller with RAID 0/1 support
|
Serial-ATA (SATA) SFF Hard
Drive
NOTE: The HP embedded 2 Port SATA
controller does not support RAID, hot plug drive functionality or drive
activity LEDs. |
60GB 1.5G SATA 5.4K |
Up to 2
|
0-1
|
HP embedded 2 Port SATA Controller
with RAID 0/1 support |
|
External Storage |
| Quantity
Supported | Position
Supported |
Host Controller or Adapter
|
| Modular
Smart Array 20 Family |
Please see the Modular Smart Array 20 QuickSpecs to determine
configuration requirements |
External |
Smart Array 6402/128 Controller Smart Array 6404/256 Controller Smart
Array 642 Controller
64-Bit/133-MHz Single Channel Ultra320 SCSI HBA G2
| | Modular
Smart Array 30 Family |
Please see the Modular Smart Array 30 QuickSpecs to determine
configuration requirements. |
External | Smart
Array 6402/128 Controller Smart Array 6404/256 Controller Smart Array
642 Controller
64-Bit/133-MHz Single Channel Ultra320 SCSI HBA G2 |
|
Modular Smart Array 50 Enclosure |
2 |
External |
HP Smart Array P600/256 BBWC Controller |
| Modular
Smart Array 500 G2 System |
1 |
External | Smart
Array 642 Controller (used as Host Bus Adapter) Please see the Modular Smart
Array 500 G2 QuickSpecs for the latest list of supported HBAs: https://www.hp.com/go/msa500
| | Modular
Smart Array 1500 cs |
Please see the Modular Smart Array 1500 cs QuickSpecs below
to determine configuration requirements |
External | Please
see the Modular Smart Array 1500 cs QuickSpecs (URL below) for the latest list
of supported HBAs | | Modular
Smart Array 1000 |
Please see the Modular Smart Array 1000 QuickSpecs below to
determine configuration requirements |
External | Please
see the Modular Smart Array 1000 QuickSpecs (URL below) for the latest list of
supported HBAs | |
Modular Smart Array 1000: https://h18000.www1.hp.com/products/quickspecs/11033_div/11033_div.html
(Worldwide)
Modular Smart Array 1500 cs: https://www.hp.com/go/MSA1500cs
| |
Tape Drives, Tape
Autoloaders, & Tape Libraries |
NOTE: For an up-to-date listing of the
latest O/S Support details for each of the Tape Drives listed below, please
see the following:
https://h18000.www1.hp.com/products/quickspecs/division/10233.html
(Worldwide)
NOTE: For an up-to-date listing of the latest O/S Support details
for each of the Tape Autoloaders and Tape Libraries listed below, please
see the following:
https://h18000.www1.hp.com/products/quickspecs/division/10809.html
(Worldwide)
NOTE: For complete listing of tape drive offerings see https://www.hp.com/products1/storage/compatibility/tapebackup/ISS/index.html
For recommended tape drive offerings for this ProLiant server see the
following:
|
|
Position
Supported
|
Controller
|
Controller Part Numbers
|
|
|
|
|
|
HP StorageWorks Tape Drives,
External
DAT 24 USB
DAT 40 USB
DAT 72 USB |
External
|
|
N/A
|
|
|
|
|
HP StorageWorks Tape Drives,
External
Ultrium 232
Ultrium 448
Ultrium 460
Ultrium 920
Ultrium 960
DAT 40
DAT 72
DLT VS160
SDLT 600 |
External
|
64-Bit/133-MHz Single Channel Ultra320 SCSI HBA G2
|
|
|
|
|
|
HP StorageWorks Autoloaders,
External
DAT 72x10 Autoloader
1/8 G2 Tape Autoloader |
External
|
64-Bit/133-MHz Single Channel Ultra320 SCSI HBA G2
|
374654-B21
|
|
|
|
|
HP StorageWorks SCSI Rack-Mount
Tape Drive Enclosures
1U Rack-Mount Kit
3U Rack-Mount Kit |
External
|
64-Bit/133-MHz Single Channel Ultra320 SCSI HBA G2
|
374654-B21
|
|
|
|
|
HP StorageWorks USB Rack-Mount
Tape Drive Enclosures
1U Rack-Mount Kit |
External
|
|
|
|
|
|
|
HP StorageWorks Tape Libraries,
External
MSL2024 (Ultrium 448, Ultrium 920 and 960-based)
MSL4048 (Ultrium 448, Ultrium 920 and 960-based)
MSL6000 (Ultrium 960 and 460-based)
MSL6000 (SDLT 600-based)
|
External
|
|
N/A
|
Power Specifications
To review typical system
power ratings use the Active Answers Power Calculator which is available
via the online tool located at URL: https://h30099.www3.hp.com/configurator/calc/Power%20Calculator%20Catalog.xls
To drill down to calculators:
- Click on: "ProLiant Servers"
- Click on the Server of interest. Example: DL360 G4p
- Click on: "Power Calculator" link. (You may need to scroll
down to see it)
|
Quickspecs
System Unit |
Dimensions (H x W x D) |
1.70 x 16.78 x 27.75
in (4.32 x 42.62 x 70.49 cm) |
Weight |
Maximum (two hard drives installed,
two power supply, two processor) |
37 lb (16.78 kg) |
|
No hard drives installed, one
power supply, one processor |
27.5 lb (12.47 kg) |
Input Requirements
|
Rated Input Voltage |
100 to 240 VAC |
|
Rated Input Current |
5.85 Amps (100 V) to 2.85 Amps
(200 V) |
|
Rated Input Frequency |
50 to 60 Hz |
|
Rated Input Power |
585 W (100VAC) to 565 W (200VAC)
NOTE: 585 W of Rated Input Power is for the
Maximum Peak Output Power of 535
W.
|
BTU Rating
|
2000 BTU/HR
NOTE: The BTU rating listed is for
the Rated Input Power of 585 W.
|
|
Power Specifications |
To review typical system power
ratings use the Power Calculator which is available via the online tool
located at URL: https://h30099.www3.hp.com/configurator/calc
/Power%20Calculator%20Catalog.xls
To drill down to calculators:
- Click on: "ProLiant Servers"
- Click on the Server of interest. Example: DL360 G4p
- Click on: "Power Calculator" link. (You may need to scroll
down to see it)
|
Power Supply Output Power
(per power supply) |
Rated Steady-State Power |
535
W |
Temperature Range
|
Operating |
10° to 35°C at sea level
with an altitude derating of 1.0°C per every 300m (1000ft) above sea
level to a maximum of 3000m (10,000ft), no direct sustained sunlight. Maximum
rate of change is 10°C/Hr. |
Storage |
-30° to 60°C - Maximum
rate of change is 20°C/Hr. |
Relative Humidity
(non-condensing) |
Operating |
10 to 90% relative humidity (Rh),
28°C maximum wet bulb temperature |
Storage |
5 to 95% relative humidity (Rh),
38.7°C maximum wet bulb temperature |
Maximum Wet Bulb Temperature
|
38.7° C |
|
SCSI Connectors |
No external VHDCI connector |
|
Acoustic Noise |
Idle
(Fixed Disk Drives Spinning) |
|
|
L WAd (BELS)
|
6.6 |
|
L pAm (dBA)
|
50 |
|
Operating
(Random Seeks to Fixed Disks) |
|
|
L WAd (BELS)
|
6.9 BELS |
|
L pAm (dBA)
|
53 dBA |
|
Smart Array 6i Controller
(integrated on system board)
(SCSI models) |
Data Compatible with all Smart Array
Controllers |
Yes |
Instant Upgrades to other Smart
Array Controllers |
Yes |
Consistent Software Manageability
Tools |
Yes |
PCI-X Bus |
64-bit up to 133 (integrated on
system board) |
PCI-X Peak Data Transfer Rate |
1066 MB/s |
SCSI Protocols Supported |
Ultra320, Ultra3, Ultra2 |
SCSI Peak Data Transfer Rate |
320 MB/s |
Channels |
1 |
SCSI Ports
(external/internal)
|
0/1
|
Drives Supported
(maximum)
|
2 drives
|
Cache |
64 MB Read Cache |
Battery-Backed Write Cache |
Yes, with installation of Battery-Backed
Write Cache Enabler, up to 128MB |
RAID Support |
0, 1, 1+0, 5 |
Logical Drives
(maximum)
|
32 logical drives |
Online Configuration |
Yes |
Online Capacity Expansion |
Yes |
Logical Drive Capacity Extension |
Yes |
Online Stripe Size Migration |
Yes |
Online RAID Level Migration |
Yes |
Online Spare Support |
Yes |
Automatic Data Recovery |
Yes |
Drive Roaming |
Yes |
|
Integrated Serial
ATA Controller
(SATA models) |
Simultaneous drive transfer channels |
Support for up to 2 hard drives
|
Transfer rate synchronous (maximum
theoretical) |
150 MB/s per channel; 300MB/s in
RAID 0 pair |
Protocol |
Serial ATA |
Drive support |
HP Universal Serial ATA |
Data transfer modes |
ATA data-transfer modes supported
SATA 1.0, SATA II
PIO modes 0-4
Multiword DMA modes 0-2
Ultra DMA modes 0-6 |
Feature |
Supports Pre-Failure Warranty of
SATA Hard Drives
Support for Systems Insight Manager
Supports multiple logical volumes
Setup through ROM based Array Configuration Utility
Installation scripting support |
OS Support |
Microsoft Windows 2000 Server
Microsoft Windows Server 2003
Novell NetWare
Linux (Red Hat, SuSE, UnitedLinux) |
NOTE:
This controller does not support LED functions. This controller does not
support Hot Plug functions. |
|
Smart Array P600
Controller
(SAS models only) |
Disk Drive and Enclosure Protocol
Support |
3 Gbps SAS (Serial Attached SCSI)
1.5 Gbps SATA (Serial Advanced Technology Attachment) |
Architecture
|
1.5 Gb SATA |
SAS Connectors
|
1 internal SFF8484 & 1 external
SFF8470 / internal SFF8484 shared x4 Wide SAS Ports
12 Gbps per x4 Wide SAS Port (4 x 3 Gbps) |
Data Transfer Method
|
64-bit wide, PCIX 133 MHz (1 GB/s
maximum bandwidth) |
PCI Bus Speed |
PCIX-133 and 3.3 volt PCI compatibility
only |
Memory Bus Speed |
DDR-266 and 72 bit wide bus |
PCI
|
64-bit, 133-MHz PCI-X (1 GB/s maximum
bandwidth) |
Simultaneous Drive Transfer Ports |
PCI-X and 3.3 volt PCI compatibility
only |
Port Transfer Rate |
2 x4 Wide SAS Ports |
Software upgradeable Firmware
|
12 Gb/s per x4 Wide SAS Port (4
x 3 Gb/s) |
Cache Memory
|
Yes |
Logical Drives Supported
|
256 MB Read/Write (512-MB module
upgrade available);
ECC protection, battery-backed, and removable |
Maximum Capacity
|
Up to 32 logical drives
Up to 2.2 TB per logical drive |
Memory Addressing
|
2.7 TB (38 x 72 GB)
64-bit, supporting servers memory greater than 4 GB |
RAID Support |
RAID 6 (Advanced Data Guarding)
RAID 5 (Distributed Data Guarding)
RAID 1+0 (Striping & Mirroring)
RAID 0 (Striping) |
Upgradeable Firmware
Disk Drive and
|
4-MB flashable ROM |
Enclosure Protocol Support |
3 Gb SAS and 1.5 Gb SATA |
|
Embedded NC7782
PCI-X Gigabit Server Adapter |
Network Interface |
10/100/1000-T |
Compatibility |
EEE 802.3 10Base-T
IEEE 802.3ab 1000Base-T
IEEE 802.3u 100Base-TX |
Data Transfer Method |
64-bit/66MHz PCI-X
|
Network Transfer Rate |
10Base-T (Half-Duplex) |
10 Mb/s |
|
10Base-T (Full-Duplex) |
20 Mb/s |
|
100Base-TX (Half-Duplex) |
100 Mb/s |
|
100Base-TX (Full-Duplex) |
200 Mb/s |
|
1000Base-TX (Half and Full-Duplex) |
2000 Mb/s |
Connector |
RJ-45 |
|
Cable Support |
10Base-T |
Categories 3, 4 or 5 UTP up to
328 ft (100 m) |
|
10/100/1000 Base-TX |
Category 5 UTP up to 328 ft (100
m) |
|
|