DL QuickSpecs
|
DL20
|
|
DL60
|
|
DL80
|
|
DL120
|
|
DL140
|
|
DL145
|
|
DL160
|
|
DL160se
|
|
DL165
|
|
DL180
|
|
DL185
|
|
DL320
|
|
DL325
|
|
DL345
|
|
DL360
|
|
DL365
|
|
DL380
|
|
DL385
|
|
DL388
|
|
DL560
|
|
DL580
|
|
DL585
|
|
DL740
|
|
DL760
|
|
DL785
|
|
DL1000
|
|
|
ML QuickSpecs
|
ML30
|
|
ML110
|
|
ML115
|
|
ML150
|
|
ML310
|
|
ML330
|
|
ML350
|
|
ML370
|
|
ML530
|
|
ML570
|
|
ML750
|
|
|
BL QuickSpecs
|
BL10e
|
|
BL20p
|
|
BL25p
|
|
BL260c
|
|
BL280c
|
|
BL2x220c
|
|
BL30p
|
|
BL35p
|
|
BL40p
|
|
BL420c
|
|
BL45p
|
|
BL460c
|
|
BL465c
|
|
BL480c
|
|
BL495c
|
|
BL60p
|
|
BL620c
|
|
BL660c
|
|
BL680c
|
|
BL685c
|
|
BL860c
|
|
|
SL QuickSpecs
|
SL160z
|
|
SL165z
|
|
SL170s
|
|
SL170z
|
|
SL230s
|
|
SL250s
|
|
SL270s
|
|
SL2x170z
|
|
SL335s
|
|
SL390s
|
|
SL4540
|
|
SL4545
|
|
|
XL QuickSpecs
|
XL170r
|
|
XL190r
|
|
XL220a
|
|
XL230a
|
|
XL730f
|
|
XL740f
|
|
XL750f
|
|
|
CL QuickSpecs
|
CL1850
|
CL1850 G1
| |
CL380
|
CL380 G1
| |
|
|
|
|
|
|
|
Proliant BL460c G8 QuickSpecs |
US QuickSpecs |
|
|
|
|
|
|
|
|
|
Proliant BL460c G8 Overview
HP ProLiant BL460c Generation 8 (Gen8) Server Blade
|

|
HP
ProLiant BL460c Generation 8 (Gen8) Server Blade
|
1.
|
Two
(2) PCIe 3.0 mezzanine I/O expansion slots
|
7.
|
Up
to two (2) Intel® Xeon® E5-2600 family processors
|
2.
|
FlexibleLOM adapter
|
8.
|
Internal
USB 2.0 and Trusted Platform Module (TPM) connectors
|
3.
|
MicroSDHC card connector
|
9.
|
Two
(2) small form factor (SFF) hot-plug drive bays
|
4.
|
FlexibleLOM connectors (supporting
one (1) FlexibleLOM)
|
10.
|
HP
c-Class Blade SUV (Serial, USB, VGA) connector
|
5.
|
Sixteen (16) DDR3 DIMM memory
slots (8 per processor)
|
11.
|
HP
Smart Array P220i Controller with 512MB FBWC
|
6.
|
HP Smart Array P220i Controller
connector
|
12.
|
Access panel
|
|
What's
New
|
- Support
for the Intel® Xeon® processor E5-2600 v2 product family
|
Standard Features
NOTE:
This document covers the HP ProLiant BL460c Gen8 server blade only. For information
on HP BladeSystems c-Class Enclosures and HP BladeSystem c-Class Interconnect
and Mezzanine Components, please see the following:
HP BladeSystem c-Class
Enclosures QuickSpecs:
NOTE:
For proper BladeSystem operation, the minimum required versions of HP Onboard
Administrator and HP Virtual Connect are required and available via the HP Service
Pack for ProLiant, please see https://www.hp.com/go/spp/download.
|
|
NOTE: For the
Standard Features shipped in the "Factory Integrated Models", please
see the "Configuration Information - Factory Integrated Models" section.
|
Processor
One of the following depending on Model
|
E5-2600
v2 series Processors
|
Intel®
Xeon® E5-2697 v2 (2.7GHz/12-core/30MB/8.0GT-s QPI/130W, DDR3-1866, HT, Turbo2-
3/3/3/3/3/3/3/4/5/6/7/8)
|
Intel®
Xeon® E5-2695 v2 (2.4GHz/12-core/30MB/8.0GT-s QPI/115W, DDR3-1866, HT, Turbo2-
4/4/4/4/4/4/4/4/5/6/7/8)
|
Intel®
Xeon® E5-2690 v2 (3.0GHz/10-core/25MB/8.0GT-s QPI/130W, DDR3-1866, HT, Turbo2-
3/3/3/3/3/3/3/4/5/6)
|
Intel®
Xeon® E5-2680 v2 (2.8GHz/10-core/25MB/8.0GT-s QPI/115W, DDR3-1866, HT, Turbo2-
3/3/3/3/3/4/5/6/7/8)
|
Intel®
Xeon® E5-2670 v2 (2.5GHz/10-core/25MB/8.0GT-s QPI/115W, DDR3-1866, HT, Turbo2-
4/4/4/4/4/4/5/6/7/8)
|
Intel®
Xeon® E5-2660 v2 (2.2GHz/10-core/25MB/8.0GT-s QPI/95W, DDR3-1866, HT, Turbo2-
4/4/4/4/4/4/5/6/7/8)
|
Intel®
Xeon® E5-2650 v2 (2.6GHz/8-core/20MB/8.0GT-s QPI/95W, DDR3-1866, HT, Turbo2-
4/4/4/4/5/6/7/8)
|
Intel®
Xeon® E5-2650L v2 (1.7GHz/10-core/25MB/8.0GT-s QPI/70W, DDR3-1600, HT, Turbo2-
2/2/2/2/2/2/2/2/3/4)
|
Intel®
Xeon® E5-2667 v2 (3.3GHz/8-core/25MB/8.0GT-s QPI/130W, DDR3-1866, HT, Turbo2-
3/3/3/3/4/5/6/7)
|
Intel®
Xeon® E5-2643 v2 (3.5GHz/6-core/25MB/8.0GT-s QPI/130W, DDR3-1866, HT, Turbo2-
1/1/1/1/2/3)
|
Intel®
Xeon® E5-2637 v2 (3.5GHz/4-core/15MB/8.0GT-s QPI/130W, DDR3-1866, HT, Turbo2-
1/1/2/3)
|
Intel®
Xeon® E5-2640 v2 (2.0GHz/8-core/20MB/7.2GT-s QPI/95W, DDR3-1600, HT, Turbo2-
3/3/3/3/3/3/4/5)
|
Intel®
Xeon® E5-2630 v2 (2.6GHz/6-core/15MB/7.2GT-s QPI/80W, DDR3-1600, HT, Turbo2-
3/3/3/3/4/5)
|
Intel®
Xeon® E5-2630L v2 (2.4GHz/6-core/15MB/7.2GT-s QPI/60W, DDR3-1600, HT, Turbo2-
2/2/2/2/3/4)
|
Intel®
Xeon® E5-2620 v2 (2.1GHz/6-core/15MB/7.2GT-s QPI/80W, DDR3-1600, HT, Turbo2-
3/3/3/3/4/5)
|
Intel®
Xeon® E5-2609 v2 (2.5GHz/4-core/10MB/6.4GT-s QPI/80W)
|
Intel® Xeon® E5-2603 v2 (1.8GHz/4-core/10MB/6.4GT-s
QPI/80W)
|
E5-2600
series Processors
|
Intel®
Xeon® E5-2690 (2.9GHz/8-core/20MB/8.0GT-s QPI/135W, DDR3-1600, HT, Turbo2-
4/4/4/5/5/7/7/9)
|
Intel®
Xeon® E5-2680 (2.7GHz/8-core/20MB/8.0GT-s QPI/130W, DDR3-1600, HT, Turbo2-
4/4/5/5/5/7/8/8)
|
Intel®
Xeon® E5-2670 (2.6GHz/8-core/20MB/8.0GT-s QPI/115W, DDR3-1600, HT, Turbo2-
4/4/5/5/6/6/7/7
|
Intel®
Xeon® E5-2665 (2.4GHz/8-core/20MB/8.0GT-s QPI/115W, DDR3-1600, HT, Turbo2-
4/4/5/5/6/6/7/7)
|
Intel®
Xeon® E5-2667 (2.9GHz/6-core/15MB/8.0GT-s QPI/130W, DDR3-1600, HT, Turbo2-
3/3/3/4/5/6)
|
Intel®
Xeon® E5-2660 (2.2GHz/8-core/20MB/8.0GT-s QPI/95W, DDR3-1600, HT, Turbo2-
5/5/6/6/7/7/8/8)
|
Intel®
Xeon® E5-2650 (2.0GHz/8-core/20MB/8.0GT-s QPI/95W, DDR3-1600, HT, Turbo2-
4/4/5/5/5/7/8/8)
|
Intel®
Xeon® E5-2650L (1.8GHz/8-core/20MB/8.0GT-s QPI/70W, DDR3-1600, HT, Turbo2-
2/2/3/3/4/4/5/5)
|
Intel®
Xeon® E5-2643 Kit (3.30 GHz/4-core/10MB/130W) Processor
|
Intel®
Xeon® E5-2640 (2.5GHz/6-core/15MB/7.2GT-s QPI/95W, DDR3-1333, HT, Turbo2-
3/3/4/4/5/5)
|
Intel®
Xeon® E5-2637 (3.0GHz/2-core/5MB/8.0GT-s QPI/80W, DDR3-1600, HT, Turbo2- 5/5)
|
Intel® Xeon® E5-2630
(2.3GHz/6-core/15MB/7.2GT-s QPI/95W, DDR3-1333, HT, Turbo2- 3/3/4/4/5/5)
|
Intel®
Xeon® E5-2630L (2.0GHz/6-core/15MB/8.0GT-s QPI/60W, DDR3-1333, HT, Turbo2-
3/3/4/4/5/5)
|
Intel®
Xeon® E5-2620 (2.0GHz/6-core/15MB/7.2GT-s QPI/95W, DDR3-1333, HT, Turbo2-
3/3/4/4/5/5)
|
Intel®
Xeon® E5-2609 (2.4GHz/4-core/10MB/6.4GT-s QPI/80W)
|
Intel®
Xeon® E5-2603 (1.8GHz/4-core/10MB/6.4GT-s QPI/80W)
|
NOTE:
The Intel Xeon E5-2600 Processor Family cannot be configured with the new 1866MHz
HP Smart Memory or the new 1600MHz Low Voltage (1.35v) HP Smart Memory.
NOTE:
DIMM slots 4 and 5 are not accessible when either the E5-2690, the E5-2643,
the E5-2643 v2, or the E5-2637 v2, or the E5-2667 v2 is used. In a 2 processor
configuration, there are twelve (12) total available DIMM slots.
NOTE:
For the maximum supported memory speeds for each processor listed above, please
reference the 'Memory Speed by Processor Model' table in the Memory section of
the QuickSpecs.
NOTE: HT indicates that the processor model supports
Intel® Hyper-Threading Technology.
NOTE: Turbo indicates the maximum
potential frequency increment when using Intel® Turbo Boost Technology, with
8, 7, 6, 5, 4, 3, 2 or 1 core(s) active.
NOTE: DDR3 speed is the maximum
memory speed of the processor. Actual memory speed may depend on the quantity
and type of DIMMs installed.
NOTE: Up to 2 processors supported. Mixing
different processor models is not supported.
NOTE: For the Intel®
C600 Chipset E5-2600 Series, the letter preceding the model number indicates the
Product Line (E3, E5, E7); 2600x, 2 = number of CPUs in a Node, 6 is socket/segment
designation, 00 = Processor SKU, and x = L for low power SKUs.
NOTE: The
BL460c Gen8 supports one or two processors.
NOTE: The BL460c Gen8 includes
two I/O mezzanine expansion slots. A processor must be installed in processor
slot 1 for access to the first mezzanine expansion slot (expansion slot 1). A
processor must be installed in processor slot 2 for access to the second mezzanine
expansion slot (expansion slot 2).
NOTE: All processors within the
server must be identical.
NOTE: All processors support Intel® Hyper-Threading
and Intel® Turbo Boost Technologies except the E5-2603 and E5-2609.
NOTE:
The letter "L" following the model number indicates denotes lower
wattage.
NOTE: The processor model as well as the memory configuration
determines the maximum speed memory can operate. Please see the see the "Memory"
section later in this document.
NOTE: The Intel Xeon E5-2620 processor
does not support DIMMs at 1.35V. Using the HP RBSU, 1.35V DIMMs can be changed
to operate at 1.5V.
NOTE: When HP 24GB (1x24GB) Three Rank x4 PC3L-10600R
(DDR3-1333) Registered CAS-9 Low Voltage FIO Memory Kits are used with any processors
except the E5-2690, the E5-2643, the E5-2637 v2, the E5-2643 v2, or the E5-2667
v2 all 16 DIMM slots on the BL460c Gen8 must be fully populated with these 24GB
DIMMs. When HP 24GB (1x24GB) Three Rank x4 PC3L-10600R (DDR3-1333) Registered
CAS-9 Low Voltage FIO Memory Kits are used with either the E5-2690, the E5-2643,
the E5-2637 v2, the E5-2643 v2, or the E5-2667 v2, all 12 available DIMM slots
on the BL460c Gen8 must be fully populated with these 24GB DIMMs.
|
|
Cache
Memory
One of the following depending on Model
|
30MB
(1x30MB) L3 cache
NOTE: For Twelve-core
processors.
|
25MB
(1x25MB) L3 cache
NOTE: For Six, Eight
or Ten-core processors.
|
20MB
(1x20MB) L3 cache
NOTE: For Eight-core
processors.
|
15MB (1x15MB) L3 cache
NOTE: For Quad
or Six-core processors.
|
10MB
(1x10MB) L3 cache
NOTE: For Quad-core
processors.
|
5MB
(1x5MB) Level 3 cache
NOTE: For Dual-core
processors.
|
|
Memory Protection
|
Advanced
ECC
|
Memory Online
Spare Mode (Rank Spare Mode)
|
Lockstep
Mode
|
|
Memory
One of the following depending on Model
|
Type
|
HP
SmartMemory
|
DDR3
Load Reduced (LRDIMM), Registered (RDIMM), or Unbuffered ECC (UDIMM)
|
Standard (Pre-configured Models)
|
64GB (8 x 8GB) DDR3 1600MHz
RDIMMs at 1.5V
64GB (4 x 16GB) DDR3 1866MHz RDIMMs at 1.5V
32GB (4 x 8GB)
DDR3 1600MHz RDIMMs at 1.5V
32GB (2 x 16GB) DDR3 1866MHz RDIMMs at 1.5V
32GB
(4 x 8GB) DDR3 1333MHz RDIMMs at 1.35V
32GB (2 x 16GB) DDR3 1600MHz RDIMMs
at 1.35V
16GB (2 x 8GB) DDR3 1866MHz RDIMMs at 1.5V
16GB (4 x 4GB) DDR3
1333MHz RDIMMs at 1.35V
16GB (2 x 8GB) DDR3 1600MHz RDIMMs at 1.35V
|
Maximum (LRDIMM)
|
512GB
(16 x 32GB) up to 1333MHz at 1.35V
|
Maximum
(RDIMM)
|
256GB (16 x 16GB) up
to 1600MHz at 1.5V
384GB (16 x 24GB) up to 1333MHz at 1.35V
|
Maximum (UDIMM)
|
128GB
(16 x 8GB) up to 1600MHz at 1.5v
|
NOTE:
HP memory from previous generation servers are not qualified or warranted
with this server. HP SmartMemory is required to realize the memory performance
improvements and enhanced functionality listed in this document for Gen8. For
additional information, please see the HP SmartMemory QuickSpecs at: https://h18000.www1.hp.com/products/quickspecs/14225_na/14225_na.html
NOTE: LRDIMM, RDIMM and UDIMMs are all distinct memory technologies and
cannot be mixed within a server. The majority of ProLiant Gen8 servers support
RDIMM, UDIMM and LRDIMM.
NOTE: The internal USB 2.0 Port is not available
when the HP 24GB (1x24GB) Three Rank x4 PC3L-10600R (DDR3-1333) Registered CAS-9
Low Voltage FIO Memory Kits (700404-B21) are used.
NOTE: When HP 24GB
(1x24GB) Three Rank x4 PC3L-10600R (DDR3-1333) Registered CAS-9 Low Voltage FIO
Memory Kits are used with any processors except the E5-2690, the E5-2643, the
E5-2637 v2, the E5-2643 v2, or the E5-2667 v2 all 16 DIMM slots on the BL460c
Gen8 must be fully populated with these 24GB DIMMs. When HP 24GB (1x24GB) Three
Rank x4 PC3L-10600R (DDR3-1333) Registered CAS-9 Low Voltage FIO Memory Kits are
used with either the E5-2690, the E5-2643, the E5-2637 v2, the E5-2643 v2, or
the E5-2667 v2, all 12 available DIMM slots on the BL460c Gen8 must be fully populated
with these 24GB DIMMs.
NOTE: The Intel Xeon E5-2600 Processor Family
cannot be configured with the new 1866MHz HP Smart Memory or the new 1600MHz Low
Voltage (1.35v) HP Smart Memory.
NOTE: Depending on the memory configuration
and processor model, the memory speed may run at 1866MHz, 1600MHz, 1333MHz, or
1066MHz. Please see Memory Population Table or the Online Memory Configuration
Tool at: www.hp.com/go/ddr3memory-configurator.
|
|
Network
Controller
One of the following depending
on Model
|
One (1) HP FlexFabric
10Gb 2-port 534FLB FlexibleLOM or HP FlexFabric 10Gb 2-port 554FLB FlexibleLOM
NOTE: Supports FCoE, Flex-10, TCP/IP offload
engine, hardware-based accelerated iSCSI, iSCSI boot, and autosensing 10Gb/1Gb
Ethernet.
NOTE: Each port is autosensing 1Gb/10Gb, and can interoperate
with 1Gb HP BladeSystem c-Class interconnect components. Both ports will operate
at the same speed.
NOTE: FlexFabric capabilities require the use of
an HP Virtual Connect FlexFabric module. Fibre Channel over Ethernet (FCoE) is
supported with the HP 10GbE Pass-Thru Module, HP 6120XG Blade Switch with the
CEE license installed, HP Cisco B22HP Fabric Extender and HP Cisco B22HP Fabric
Extender with 16 FET for BladeSystem c-Class. Learn more at: https://www.hp.com/go/bladesystem/interconnects
One (1) HP Flex-10 10Gb 2-port 530FLB FlexibleLOM
One (1) HP Ethernet
10Gb 2-port 560FLB FlexibleLOM
NOTE: FlexibleLOMs
are not compatible with prior generation c-Class server blades
Standard
iLO Network Controller:
One (1) 10/100 Mbps port for the HP iLO 4 to Onboard
Administrator link. The Onboard Administrator (with 10/100/1000 Mbps) to BladeSystem
link is 1Gbps
|
|
Expansion Slots
|
Two (2) I/O expansion mezzanine slots:
- x16 PCIe 3.0 Type A (supports Type A mezzanine cards) (expansion slot
1).
NOTE: This expansion slot supports
dual-port mezzanine cards: one port is routed to interconnect module
bay 3 and the other to bay 4.
- x16 PCIe 3.0 Type B (supports Type A and Type B mezzanine cards (expansion
slot 2).
NOTE: This expansion slot supports
dual-port and quad-port mezzanine cards. For dual-port cards, one port
is routed to interconnect module bay 5 and the other to bay 6. For quad-port
cards, one port is routed to interconnect module bay 5, one to bay 6,
one to bay 7, and one to bay 8.
NOTE: A second processor must be installed (in processor slot
2) to have access to the second expansion slot (expansion slot 2).
Mezzanine card options include:
- Dual-port 10Gb FlexFabric, 10Gb Flex-10, 10GbE options, and quad-port
1Gb Ethernet server adapter mezzanine options for additional network
ports.
- Dual-port 8Gb Fibre Channel HBA for SAN connectivity.
- QDR and FDR InfiniBand for low latency and high bandwidth server interconnectivity.
- I/O accelerator mezzanine options for high transaction rate local
storage
|
|
HP Server ROM
|
HP ROM (read only memory) is
now digitally signed using HP's Corporate Signing Service. This signature
is verified before the flash process starts, reducing accidental programming
and preventing malicious efforts to corrupt system ROM.
HP ROM provides for essential initialization and validation of hardware
components before control is passed to the customer-installed operating
system. The ROM also provides the capability of booting from various fixed
media (HDD, CD-ROM) and removable media (USB), to continue operation to
the operating system.
HP ROM performs very early configuration of the video controller, to
allow monitoring of initialization progress via an attached monitor. If
configuration or hardware errors are discovered during this early phase
of hardware initialization, suitable messages are now displayed on the
connected monitor. Additionally, these configuration or hardware errors
are logged to the Integrated Management Log (IML) to assist in diagnosis.
HP's ProLiant ROM is used to configure the following:
- Processor and chipset status registers
- System memory, memory map, and memory initialization
- System hardware configuration (integrated PCI devices and optional
PCIe cards).
- Customer-specific BIOS configuration using the HP ROM-Based Setup
Utility (RBSU).
NOTE: For further information, please
refer to HP's RBSU (ROM based setup utility) user guide: www.hp.com/support/rbsu
|
|
Storage
Controller
|
All BTO Models
|
One
(1) HP Smart Array P220i Controller with 512MB Flash-Backed Write Cache (FBWC)
supporting RAID 0 and RAID 1.
NOTE:
Upgradeable firmware with recovery ROM.
NOTE: The HP Smart Array P220i
supports two (2) small form factor (SFF) hot plug drive bays.
NOTE:
The server supports up to a combined total of two (2) FBWC supercap options.
NOTE:
The HP Smart Array P220i Controller FIO Kit (690164-B21) comes included with
the HP ProLiant BL460c Gen8 10Gb FlexibleLOM Configure-to-order Blade Server (641016-B21).
However when choosing the HP ProLiant BL460c Gen8 E5-v2 10Gb FlexibleLOM Configure-to-order
Blade Server (735151-B21), the HP Smart Array P220i Controller FIO Kit (690164-B21)
must be added separately as part of the Server Blade Configuration Process.
|
|
Maximum
Internal Storage
One of the following depending
on Model
|
Hot Plug
SFF SAS
|
2.4TB
|
2 x 1.2TB
|
Hot Plug
SFF SATA
|
2.0TB
|
2
x 1.0TB
|
Hot Plug
SFF SAS SSD
|
1.6TB
|
2
x 800GB
|
Hot Plug
SFF SATA SSD
|
1.6TB
|
2x800GB
|
NOTE:
The ProLiant BL460c Gen8 server includes the new HP hot plug small form factor
(SFF) SmartDrive carrier for enhanced management and reduced maintenance errors.
HP drives from previous generation servers are not compatible with the ProLiant
BL460c Gen8 drive bays.
|
|
Interfaces
|
Micro
SDHC Slot
|
One (1) internal
Micro Secure Digital High Capacity (Micro SDHC) card slot
|
USB
2.0 Port
|
One (1) internal
USB 2.0 connector for USB flash media drive keys
|
NOTE:
The above options are for integrated hypervisor virtualization environments needing
a low cost boot solution with the highest performance and reliability.
NOTE:
The internal USB 2.0 Port is not available when the HP 24GB (1x24GB) Three Rank
x4 PC3L-10600R (DDR3-1333) Registered CAS-9 Low Voltage FIO Memory Kits (700404-B21)
are used.
|
|
Industry Standard Compliance
|
ACPI 2.0
Microsoft® Logo certifications
USB 2.0 Support
IPMI 2.0
Secure Digital 2.0
TPM 1.2 Support
IEEE (specific IEEE standards depending on Ethernet adapter card(s) installed)
Advanced Encryption Standard (AES)
Triple Data Encryption Standard (3DES)
SNMP
SSL 2.0
DMTF Systems Management Architecture for Server Hardware Command Line
Protocol (SMASH CLP)
Active Directory v1.0
PCIe 3.0
|
|
Enclosures
|
HP offers two different c-Class server blade enclosures to meet your
individual needs:
- The HP BladeSystem c7000 rack enclosure is 10U high and holds up to
sixteen (16) ProLiant BL460c Gen8 servers plugged vertically.
- The HP BladeSystem c3000 rack enclosure is 6U high and holds up to
eight (8) HP ProLiant BL460c Gen8 servers plugged horizontally.
- Server blades, storage blades, interconnect modules, power supplies,
fans, and redundant Onboard Administrator modules are all designed to
fit into the c3000 and c7000 enclosures.
NOTE: For additional enclosure
information, please see: https://h18004.www1.hp.com/products/blades/components/enclosures/c-class/index.html
|
|
Graphics
|
Integrated Matrox G200 video standard
- 1280 x 1024 (32 bpp)
- 1920 x 1200 (16 bpp)
|
|
HP
iLO 4 On System Management Memory
- 16 MB Flash Video Memory
- 256
MB DDR 3 with ECC (112 MB after ECC and video)
|
|
Form Factor
|
HP ProLiant BL460c Gen8 is a half-height server blade that plugs into the HP
BladeSystem c3000 and c7000 enclosures.
|
|
On System Management
|
HP iLO Management Engine
|
HP iLO Management Engine is a comprehensive set of embedded management
features supporting the complete lifecycle of the server, from initial
deployment, through ongoing management, to service alerting and remote
support. HP iLO Management Engine comes standard on all HP ProLiant Gen8
servers. The HP iLO Management Engine portfolio includes:
- HP iLO: The HP iLO management processor is the core foundation
for other capabilities within HP iLO Management Engine
- HP Agentless Management: Provides built in server health monitoring
and alerting capability without OS agents, that starts working the moment
a power cord and an Ethernet cable are connected.
- HP Active Health System: Always on, continuous monitoring for
increased stability and shorter downtimes; 100% configuration history;
Health and service alerts and easy export and upload to Service and
Support.
- HP Intelligent Provisioning: Lets customers provision and configure
a single server without any separate media. No more SmartStart CDs or
Smart Update Firmware DVD are needed.
- To start Intelligent Provisioning:
- Press the F10 key during the ProLiant Gen8 server boot process
(also known as power on self test or POST).
- Please go to the Intelligent Provisioning website at www.hp.com/go/intelligentprovisioning
for additional information and to view usage videos.
- Use the Service Pack for ProLiant (SPP) at www.hp.com/go/spp
to get firmware and software updates.
- HP iLO Mobile App: Enables the ability to access, deploy, and
manage your server anytime from anywhere from select smartphones and
mobile devices. For additional information please visit: www.hp.com/go/ilo/mobileapp
NOTE: For more information, visit: https://www.hp.com/go/ilo
or HP iLO Management Engine technologies whitepaper
|
|
HP
Insight management software
|
HP Service Pack
for ProLiant (SPP)
|
HP Service Pack for
ProLiant (SPP) and HP Smart Update Manager (HP SUM) provide a comprehensive approach
to firmware and system software maintenance. Together they provide better operating
stability and ensure maximum uptime. The SPP will be updated at a predictable
cadence, typically coinciding with new HP server hardware launches. By enabling
firmware to be updated online and integrating firmware and system software updates
in one operation, HP SUM and the SPP offer faster updates of individual servers
and dramatically faster updates of entire BladeSystem enclosures. Further improving
system uptime and stability is the fact that HP provides 12 months of support
for each Service Pack for ProLiant release.
The user experience around HP SUM
and the SPP has been improved in several ways, starting with the web download.
A single web page provides access to a single download containing both the latest
version of HP SUM and the latest SPP. Optional smaller subsets with only specific
types of servers or specific operating systems are offered to save on download
time. The HP SUM application provides a straightforward, intuitive user interface
that guides the user through the steps of discovery, analyses and update, providing
comprehensive information on available updates, criticality and interdependencies.
This information is also available in reports. By providing the option of multiple
local or shared repositories which can be easily updated from hp.com, HP SUM provides
the tools to optimize stability and consistency throughout the company. While
HP SUM and the SPP recommend the combinations of firmware and system software
that HP has found to be the best practice, the application gives customers the
flexibility to set their own specific baseline.
The Service Pack for ProLiant
has been rigorously tested with specific attention for interaction between firmware,
drivers and agents both within the server as well as in interaction with the BladeSystem
enclosure components (Onboard Administrator and Virtual Connect). This testing
ensures the highest quality as well as providing the input for HP SUM to deploy
updates taking into account all interdepencies, when determining the correct updates
and order of update deployment.
NOTE:
The Service Pack for ProLiant (which includes HP SUM) can be downloaded from www.hp.com/go/spp/download.
More information can be found: https://www.hp.com/go/SmartUpdate,
www.hp.com/go/spp and https://www.hp.com/go/hpsum
|
|
Security
|
- Power-on password
- Administrator's password
- Keyboard password (QuickLock)
- HP iLO 4 On System Management Chipset with:
- SSL encryption
- Secure Shell version 2
- Advanced Encryption Standard (AES) and Triple Data Encryption
Standard (3DES) on browser, CLP and XML scripting interface
- AES and RC4 encryption of video
- External USB port enable/disable
- Network server mode
- Serial interface control
- TPM (Trusted Platform Module) 1.2 option
- Advanced Encryption Standard (AES)
- Intel® Advanced Encryption Standard-New Instructions (AES-NI)
|
|
Availability
|
Memory
- Advanced ECC uses single device data correction (SDDC) to detect and
correct single and all multi-bit error that occurs within a single DRAM
chip. Both x4 and x8 SDDC are supported (x8 requires lockstep mode).
- Memory online spare mode (also known as rank spare mode) detects a
rank that is degrading and switches operation to the spare rank.
- Memory Lockstep mode is used to correct a single x8 DRAM device failure
on a DIMM. The DIMMs in each paired memory channel must have identical
HP part numbers.
- Memory demand and patrol scrubbing to prevent accumulation of correctable
errors and reducing the likelihood of unplanned downtime.
- Failed DIMM isolation improves the service time thus improving the
overall system availability.
- Address parity protection available on RDIMMs and LRDIMMs detects
address bit errors to improve service time and overall system availability.
Mezzanine options and I/O
- Support for one (1) FlexibleLOM, providing two (2) (i.e. redundant)
Ethernet ports
- Multiple mezzanine I/O expansion slots that support a wide variety
of mezzanine cards each supporting multiple data paths routed to redundant
interconnect modules.
- Network Adapter Teaming (bonding) provides network fault tolerance,
transmit load balancing, and switch-assisted load balancing.
Storage
- Two (2) Small Form Factor hot-plug SAS/SATA/SSD drive bays.
- Integrated HP Smart Array P220i Controller with 512MB FBWC, RAID 0
and 1 support, and upgradeable firmware with recovery ROM capability.
- Optional HP D2200sb Storage Blade for direct attachment of up to 12
drives to an adjacent blade within the c-Class enclosure.
- Optional dual-port Fibre Channel mezzanine card(s) for redundant SAN
connections.
Processor/Chipset
- Processor internal sensors & thermal control protection against
over-temperature conditions.
- Cache parity/ECC protects cache data from accidental data corruption.
- Machine Check Architecture (MCA) detects and captures hardware errors
such as system bus, memory ECC, parity, and cache, and improves service
time.
- Intel® QPI Protocol Protection allows detection of data errors
using a checksum of 8-bits.
- Core Disable for FRB (fault resilient boot) allows a system to power-on
despite a failing core-pair. It uses BIST (built-in self test) results
to detect a failure and disables the target core-pair upon subsequent
boot.
Server Blade Enclosure Infrastructure
- Pooled power for true N+N power redundancy through up to six (6) hot-plug,
high-efficiency, common slot enclosure-based power supplies (configuration
dependent).
- Up to ten (10) redundant enclosure-based hot-plug HP Active Cool fans
that scale to meet future demands and optimize airflow, reduce power
draw, and improve acoustic performance.
- Dual grid power providing redundant rack enclosure power feeds to
the server blade enclosure.
- HP Dynamic Power Saver Mode the total enclosure power consumption
is monitored in real time and automatically adjusted with changes in
demand for improved efficiency and reliability.
- HP Dynamic Power Capping safely limits power usage without impacting
performance by capping peak usage instead of average power usage, removes
risk to electrical infrastructure with a fast-acting, hardware-based
capping algorithm, and reclaims more power by dynamically controlling
power limits based on workload demand.
- Up to eight interconnect modules per server blade enclosure providing
four simultaneous redundant fabrics for FlexFabric, Virtual Connect
Ethernet, Fibre Channel, InfiniBand, Pass Thru Ethernet, etc.
- Enclosure crosslinks between adjacent enclosures to provide interconnect
module-to-module connections or as Virtual Connect module stacking links.
- Optional enclosure redundant Onboard Administrator system management
module.
|
|
Warranty
|
This product is covered by a global limited warranty and supported by
HP Services and a worldwide network of HP Authorized Channel Partners.
Hardware diagnostic support and repair is available for three years from
date of purchase. Support for software and initial setup is available
for 90 days from date of purchase. Enhancements to warranty services are
available through HP Care Pack services or customized service agreements.
Certain restrictions and exclusions apply. Hard drives have either a one
year or three year warranty; refer to specific hard drive QuickSpecs for
details.
NOTE: Server warranty includes
3-year Parts, 3-year Labor, 3-year on-site support. Warranty repairs may
be accomplished through the use of Customer Self Repair (CSR) parts. These
parts fall into two categories: 1) Mandatory CSR parts are designed for
easy replacement. A travel and labor charge will result when customers
decline to replace a Mandatory CSR part; 2) Optional CSR parts are also
designed for easy replacement but may involve added complexity. Customers
may choose to have HP replace Optional CSR parts at no charge. Additional
information regarding worldwide limited warranty and technical support
is available at
https://h18004.www1.hp.com/products/servers/platforms/warranty/index.html.
|
Optional Features
Fibre Channel Support
|
Up to two (2) optional Fibre Channel mezzanine HBAs are supported on
the HP ProLiant BL460c Gen8.
|
|
HP Virtual Connect
|
HP Virtual Connect is an interconnect option for BladeSystem c-Class
that simplifies server connectivity to data and storage networks, and
reduces costs. Unique HP Flex-10 technology makes maximum use of network
bandwidths, provide dynamic tuning and enable extreme flexibility to meet
individual server and infrastructure requirements by allocating up to
4 network connections per server port. Virtual Connect FlexFabric modules
extend those capabilities to allocate one function per port to storage
connections. HP Virtual Connect Enterprise Manager (VCEM) provides server
management software with a central console to administer network connections
and workloads for thousands of servers. For more information on Virtual
Connect Enterprise Manager, see https://www.hp.com/go/vcem.
For more information on Virtual Connect Ethernet, Fibre Channel, Converged
Network and management options, see https://www.hp.com/go/virtualconnect.
|
|
HP
Insight management software
|
HP Insight Control
|
HP Insight Control, a product option, delivers essential infrastructure management
that can help save time and money by making it easy to deploy, migrate, monitor,
remote control, and optimize your IT infrastructure through a single, simple management
console. For more information, see https://www.hp.com/go/insightcontrol.
HP Insight Control includes one year of 24 x 7 HP Software Technical Support
and Update Service ensuring rapid access to HP support staff and proactive delivery
of software updates. For more information about this service, see https://www.hp.com/services/insight.
|
HP Matrix Operating
Environment
|
The HP Matrix Operating Environment
(Matrix OE) for ProLiant and Integrity servers is an integrated command center
that helps you instantly adjust to dynamic business demands. This advanced infrastructure
management software lets you reduce the cost of common data center tasks by up
to 40 percent while keeping pace with your changing business.
The HP
Matrix OE includes the automated provisioning, optimization, and recovery management
capabilities for HP CloudSystem Matrix, the ideal platform for private cloud and
Infrastructure as a Service (IaaS). For more information, see https://www.hp.com/go/matrixoe.
|
HP
iLO Scale-Out
|
The HP iLO Scale-Out license
ideal for web/hosting/cloud service providers and High Performance Computing environments.
This license is a specific subset of iLO Advanced functionality, provides fast
remote access through Text Console via SSH, lower operational cost with Dynamic
power capping, and faster time to resolution through Email-based Alerting and
proactive notifications. With this newly designed HP iLO Scale-Out HPC customers
now have a server management package solely design and priced for their massive
data environments. HP iLO Scale-Out is available on all HP ProLiant Gen8 SL platforms.
For more information, see: https://www.hp.com/go/iLO/scale-out
|
HP
iLO Advanced License for ProLiant Servers
|
HP
iLO management processors for HP ProLiant Gen8 servers virtualizes system controls
to help simplify server setup, engage health monitoring and power and thermal
control, and promote remote administration. HP iLO functions out-of-the-box without
additional software installation and functions regardless of the servers' state
of operation. The HP iLO can be accessed from any location via a web browser and
works hand-in-hand with HP Systems Insight Manager, Insight Control, and Matrix
Operating Environment, helping customers unleash the value of the ProLiant platform
and deliver the highest possible quality of IT service to the business.
Advanced
functionality, such as graphical remote console, multi-user collaboration, and
video record/playback can be activated with the optional HP iLO Advanced or HP
iLO Advanced for BladeSystem licenses. The Advanced licensed features offer sophisticated
remote administration of servers in dynamic data center and remote locations and
can help significantly reduce cost associated with IT-related travel and unplanned
downtime.
NOTE: For more information,
visit https://www.hp.com/go/ilo.
|
|
High
Performance Clusters
|
HP Cluster Platforms
|
HP Cluster Platforms are specifically engineered, factory-integrated large-scale
ProLiant clusters optimized for High Performance Computing, with a choice of servers,
networks and software. Operating system options include specially priced offerings
for Red Hat Enterprise Linux and SUSE Linux Enterprise Server, as well as Microsoft
Windows HPC Server. A Cluster Platform Configurator simplifies ordering. https://www.hp.com/go/clusters
|
HP HPC Interconnects
|
High Performance Computing (HPC) interconnect technologies are available for
this server as part of the HP Cluster Platform portfolio. These high-speed InfiniBand
and Gigabit interconnects are fully supported by HP when integrated within an
HP cluster. Flexible, validated solutions can be defined with the help of configuration
tools. https://www.hp.com/techservers/clusters/ucp/index.html
|
HP Insight Cluster
Management Utility
|
HP Insight Cluster Management
Utility (CMU) is an HP-licensed and HP-supported suite of tools that are used
for lifecycle management of hyperscale clusters of Linux ProLiant systems. CMU
includes software for the centralized provisioning, management and monitoring
of nodes. CMU makes the administration of clusters user friendly, efficient, and
effective. https://www.hp.com/go/cmu
|
|
Storage
Software
|
Whether you need
to solve a specific data protection, archiving, or storage command and control
challenge, or deliver on strategic consolidation, compliance, or continuity initiatives,
look no further than HP storage software. Our storage software helps you reduce
costs, simplify storage infrastructure, protect vital assets and respond faster
to business opportunities.
Storage software that gets the job done:
- Data
Protection and Recovery Software
Whether you're a large enterprise or a
smaller business, HP data protection and recovery software will cost-effectively
protect you against disaster and ensure business continuity.
- Data Archive
and Migration Software
HP's storage software enables you to comply with
data retention and retrieval requirements, improve application performance, and
reduce costs by efficiently migrating infrequently accessed or less valuable data
to lower cost storage.
- Storage Resource Management Software (SRM)
HP's
storage resource management software reduces operational costs and provides the
command and control foundation you need to efficiently manage and visualize your
physical and virtual environments.
- Data Replication Software
HP
offers array-based and host-based replication software for use in disaster recovery,
testing, application development and reporting.
- Storage Device Management
Software
Maximize your investment in HP storage and networking with software
that enables hardware-specific configuration, performance tuning and connectivity
management.
- HP StoreVirtual VSA
With HP StoreVirtual VSA you
can use the power of virtualization to turn a set of heterogeneous and disconnected
physical disk drives in your servers and storage devices into a single pool of
logical storage capacity.
NOTE: For
more information available Storage Software including QuickSpecs, please see:
www.hp.com/go/storage/software.
|
|
HP Insight Online
|
HP
Insight Online is a new addition to the HP Support Center for one stop, secure
access to product and HP support information personalized to your IT environment.
Insight Online can automatically display devices remotely monitored by HP Insight
Remote Support. With Insight Online's easy navigation you can efficiently track
your IT support contracts and device status from anywhere and at anytime. https://www.hp.com/go/insightonline
|
|
HP Proactive Insight experience
|
Prevent
problems with innovative, automated monitoring tools and proactive services. The
HP Proactive Insight experience consist of using Insight Online, Insight Remote
Support, and Proactive Care Support Service as one integrated solution. The Proactive
Insight experience provides you with expert advice and personalized, cloud-based
automated IT support, helping to prevent unplanned down time and solve problems
quickly. For more information, visit: www.hp.com/go/proactiveinsightexperience
|
|
Expansion Blade Support
|
Supports
one (1) optional storage, tape, or PCI expansion blade.
|
Factory
Express Portfolio for Servers and Storage
|
HP
Factory Express offers configuration, customization, integration and deployment
services for HP servers and storage products. Customers can choose how their factory
solutions are built, tested, integrated, shipped and deployed.
Factory
Express offers service packages for simple configuration, racking, installation,
complex configuration and design services as well as individual factory services,
such as image loading, asset tagging, and custom packaging. HP products supported
through Factory Express include a wide array of servers and storage: HP Integrity,
HP ProLiant, HP ProLiant Server Blades, HP BladeSystem, HP 9000 servers as well
as the MSAxxxx, VA7xxx, EVA, XP, rackable tape libraries and configurable network
switches.
For more information on Factory Express services on your specific
server model please contact your sales representative or go to: https://www.hp.com/go/factory-express.html
|
|
HP Simple Configurator
|
SCE is a guided self service
tool to help sales and non technical people provide customers with initial
configurations in 3 to 5 minutes. You may then send the configuration on
for configuration help, or use in your existing ordering processes. If you
require "custom" rack configuration or configuration for products
not available in SCE, please contact HP's Customer Business Center or an
Authorized Partner for assistance. https://www.hp.com/products/configurator
|
Service and Support
Service and Support
|
HP Technology Services for Industry Standard Servers and BladeSystem
Capitalizing on HP ProLiant server and HP BladeSystem capabilities requires
a service partner who understands your increasingly complex business technology
environment. That's why it makes sense to team up with the people who
know HP infrastructure hardware and software best - the experienced professionals
at HP Services.
Protect your business beyond warranty with HP Care Pack Services
HP Care Pack services offer complete care and support expertise with committed
response choices designed to meet your IT and business needs.
HP Foundation Care services offer scalable reactive support-packages
for HP industry-standard servers and software. You can choose the type
and level of service that is most suitable for your IT and business needs.
HP Proactive Care delivers high levels of system availability through
proactive service management and advanced technical response.
|
|
Recommended
HP Care Pack Services for your HP product
|
Optimized
Care
|
3-Year HP 6 hour
Call to Repair Response, Proactive Care
Combined reactive and proactive
support for hardware and software helping optimize your systems and delivering
high levels of availability through proactive service management and advanced
technical response. Hardware problem resolution to return the hardware in operating
condition within 6 hours of the initial service request. A Technical Account Manager,
as your single point of contact, will own your call or issue end to end until
resolved.
https://h20195.www2.hp.com/v2/GetPDF.aspx/4AA3-8855EEE.pdf
HP
Install c-Class Server Blade Service
This easy-to-buy, easy-to-use HP
Care Pack service helps ensure that your new HP hardware is installed smoothly,
efficiently, and with minimal disruption of your IT and business operations.
|
Standard Care
|
3-Year HP 24x7 4 hour response, Proactive Care Service
This service
gives you combined reactive and proactive support including rapid access to our
Advanced Solution Center to manage and prevent problems and a Technical Support
Specialist with a broad level of technical knowledge that will engage with additional
technical expertise as needed from HP's vast global resources.
https://h20195.www2.hp.com/v2/GetPDF.aspx/4AA3-8855EEE.pdf
HP
Install c-Class Server Blade Service
This easy-to-buy, easy-to-use HP Care
Pack service helps ensure that your new HP hardware is installed smoothly, efficiently,
and with minimal disruption of your IT and business operations
|
|
Related
Services
|
HP Proactive
Care Personalized Support - Environmental Option
The Personalized Support
option provides an assigned Account Support Manager who can bring best practices
from across the industry plus extra technical skills to your IT team. This option
is only available as an add-on to HP Proactive Care Support.
HP Proactive
Select Service
Provides a flexible way to purchase HP best-in-class consultancy
and technical services. You can buy Proactive Select Service Credits when you
purchase your hardware and then use the credits over the next 12 months. https://h20195.www2.hp.com/V2/GetPDF.aspx/4AA2-3842ENN.pdf
NOTE: Additional HP Care Pack services
can be found at: https://www.hp.com/go/cpc.
|
|
Insight
Online/Insight Remote Support
|
HP Insight Remote Support provides 24 X 7 remote monitoring, proactive notifications,
and problem resolution. This comes at no additional cost with your HP solution.
Learn more about Insight Remote Support https://www.hp.com/go/insightremotesupport
and Insight Online https://www.hp.com/go/insightonline
NOTE:
Insight Remote Support is a prerequisite for Proactive Care. All blades within
a single HP BladeSystem enclosure must be at the same service level.
|
|
HP Support Center
|
Personalized online support portal with access to information, tools and experts
to support HP business products. Submit support cases online, chat with HP experts,
access support resources or collaborate with peers. Learn more https://www.hp.com/go/hpsc
HP's Support Center Mobile App** allows you to resolve issues yourself
or quickly connect to an agent for live support. Now, you can get access to personalized
IT support anywhere, anytime.
HP Insight Remote Support and HP Support Center
are available at no additional cost with a HP warranty, HP Care Pack or HP contractual
support agreement.
NOTE: HP Support Center
Mobile App is subject to local availability.
|
|
Parts
and Materials
|
HP will provide
HP-supported replacement parts and materials necessary to maintain the
covered
hardware product in operating condition, including parts and materials for available
and
recommended engineering improvements.
Parts and components that have reached
their maximum supported lifetime and/or the
maximum usage limitations as set
forth in the manufacturer's operating manual, product
quick-specs, or the technical
product data sheet will not be provided, repaired, or replaced as
part of these
services.
The defective media retention service feature option applies
only to Disk or eligible SSD/Flash Drives replaced by HP due to malfunction.
|
|
For more information
|
To learn more on HP ProLiant servers and HP BladeSystem servers, please
contact your HP sales representative or HP Authorized Channel Partner.
Or visit: www.hp.com/services/bladesystem
|
Pre-configured Models
NOTE: For the Standard Features shipped in the "Factory Integrated
Models", please see the "Configuration Information - Factory Integrated
Models" section.
NOTE: Pre-configured models ship with the configurations
below. Options can be selected from the Core or Additional options section of
this QuickSpecs.
NOTE: HP does not allow factory integration of options
into pre-configured models. Any additional options purchased will be shipped separately.
NOTE: If you desire a custom configuration please see "Configuration
Information - Factory Integrated Models" section of this QuickSpecs.
NOTE:
All Pre-configured Models come populated with some hard drive blanks installed.
NOTE: Not all models are available in all regions. Check with your
local country HP offices for availability.
|
E5-2600
v2 series Processors
|
HP ProLiant BL460c Gen8 E5-2670v2 2P 64GB-R P220i/512 FBWC Server
724082-B21
|
Processor(s)
|
(2) Intel® Xeon® E5-2670 v2 (2.5GHz/10-core/25MB/8.0GT-s QPI/115W,
DDR3-1866, HT, Turbo2- 4/4/4/4/4/4/5/6/7/8)
|
Cache
Memory
|
25MB (1x25MB) Level 3
cache
|
Memory
|
64GB
(4x 16GB) PC3-14900R (DDR3-1866) Registered DIMMS at 1.5V)
NOTE:
Total of 16 DIMM slots.
|
Network
Controller
|
HP FlexFabric 10Gb
2-port 534FLB FlexibleLOM
|
Storage
Controller
|
HP Smart Array P220i
Controller with 512MB FBWC RAID 0,1
|
Hard
Drive
|
None ship standard
Supports
up to two (2) HP hot-plug SFF SAS/SATA/SDD drives
|
Internal
Storage
|
SAS: 2.4TB; SATA: 2.0TB;
SAS SSD: 1.6TB; SATA SSD: 1.6TB
|
Optical
Drive Bay
|
None
|
Expansion Slots
|
2
standard - Slot 1 supports Type A mezzanine Cards. Slot 2 supports Type A and
Type B mezzanine cards.
|
Management
|
HP
iLO Management Engine (standard)
|
Optional:
HP iLO Scale-Out or HP Insight Control
|
Form
Factor
|
Up to eight (8) half-height
blades supported in the HP BladeSystem c3000 Enclosure
|
Up
to sixteen (16) half-height blades supported in HP BladeSystem c7000 Enclosure
|
Warranty
|
Server
warranty includes 3-year Parts, 3-year Labor, 3-year on-site support.
|
|
HP ProLiant BL460c Gen8 E5-2660v2 2P 64GB-R P220i/512 FBWC Server
724083-B21
|
Processor(s)
|
(2) Intel® Xeon® E5-2660 v2 (2.20GHz/10-core/25MB/8.0GT-s QPI/95W,
DDR3-1866, HT, Turbo2- 4/4/4/4/4/4/5/6/7/8)
|
Cache
Memory
|
20MB (1x25MB) Level 3
cache
|
Memory
|
64GB
(4x 16GB) PC3-14900R (DDR3-1866) Registered DIMMS at 1.5V)
NOTE:
Total of 16 DIMM slots.
|
Network
Controller
|
HP FlexFabric 10Gb
2-port 534FLB FlexibleLOM
|
Storage
Controller
|
HP Smart Array P220i
Controller with 512MB FBWC RAID 0,1
|
Hard
Drive
|
None ship standard
Supports
up to two (2) HP hot-plug SFF SAS/SATA/SDD drives
|
Internal
Storage
|
SAS: 2.4TB; SATA: 2.0TB;
SAS SSD: 1.6TB ; SATA SSD: 1.6TB
|
Optical
Drive Bay
|
None
|
Expansion Slots
|
2
standard - Slot 1 supports Type A mezzanine Cards. Slot 2 supports Type A and
Type B mezzanine cards.
|
Management
|
HP
iLO Management Engine (standard)
|
Optional:
HP iLO Scale-out or HP Insight Control
|
Form
Factor
|
Up to eight (8) half-height
blades supported in the HP BladeSystem c3000 Enclosure
|
Up
to sixteen (16) half-height blades supported in HP BladeSystem c7000 Enclosure
|
Warranty
|
Server
warranty includes 3-year Parts, 3-year Labor, 3-year on-site support.
|
|
HP ProLiant BL460c Gen8 E5-2650v2 1P 32GB-R P220i/512 FBWC Server
724084-B21
|
Processor(s)
|
(1) Intel® Xeon® E5-2650 v2 (2.6GHz/8-core/20MB/8.0GT-s QPI/95W, DDR3-1866,
HT, Turbo2- 4/4/4/4/5/6/7/8)
|
Cache
Memory
|
20MB (1x20MB) Level 3
cache
|
Memory
|
32GB
(2x 16GB) PC3-14900R (DDR3-1866 Registered DIMMs at 1.5V)
NOTE:
Total of 16 DIMM slots. Only eight (8) usable with single processor.
|
Network Controller
|
HP
FlexFabric 10Gb 2-port 534FLB FlexibleLOM
|
Storage
Controller
|
HP Smart Array P220i
Controller with 512MB FBWC RAID 0,1
|
Hard
Drive
|
None ship standard
Supports
up to two (2) HP hot-plug SFF SAS/SATA/SDD drives
|
Internal
Storage
|
SAS: 2.4TB; SATA: 2.0TB;
SAS SSD: 1.6TB; SATA SSD: 1.6TB
|
Optical
Drive Bay
|
None
|
Expansion Slots
|
2
standard - Slot 1 supports Type A mezzanine Cards. Slot 2 supports Type A and
Type B mezzanine cards.
|
Management
|
HP
iLO Management Engine (standard)
|
Optional:
HP iLO Scale-out or HP Insight Control
|
Form
Factor
|
Up to eight (8) half-height
blades supported in the HP BladeSystem c3000 Enclosure
|
Up
to sixteen (16) half-height blades supported in HP BladeSystem c7000 Enclosure
|
Warranty
|
Server
warranty includes 3-year Parts, 3-year Labor, 3-year on-site support.
|
|
HP ProLiant BL460c Gen8 E5-2650Lv2 1P 32GB-L P220i/512 FBWC Server
724088-B21
|
Processor(s)
|
(1) Intel® Xeon® E5-2650L v2 (1.7GHz/10-core/25MB/8.0GT-s QPI/70W,
DDR3-1600, HT, Turbo2- 2/2/2/2/2/2/2/2/3/4)
|
Cache
Memory
|
25MB (1x25MB) Level 3
cache
|
Memory
|
32GB
(2x 16GB) PC3L-12800R (DDR3-1600 Registered DIMMs at 1.35V)
NOTE:
Total of 16 DIMM slots. Only eight (8) usable with single processor.
|
Network Controller
|
HP
FlexFabric 10Gb 2-port 534FLB FlexibleLOM
|
Storage
Controller
|
HP Smart Array P220i
Controller with 512MB FBWC RAID 0,1
|
Hard
Drive
|
None ship standard
Supports
up to two (2) HP hot-plug SFF SAS/SATA/SDD drives
|
Internal
Storage
|
SAS: 2.0TB; SATA: 2.0TB;
SAS SSD: 1.6TB
|
Optical
Drive Bay
|
None
|
Expansion Slots
|
2
standard - Slot 1 supports Type A mezzanine Cards. Slot 2 supports Type A and
Type B mezzanine cards.
|
Management
|
HP
iLO Management Engine (standard)
|
Optional:
HP iLO Scale-out or HP Insight Control
|
Form
Factor
|
Up to eight (8) half-height
blades supported in the HP BladeSystem c3000 Enclosure
|
Up
to sixteen (16) half-height blades supported in HP BladeSystem c7000 Enclosure
|
Warranty
|
Server
warranty includes 3-year Parts, 3-year3-year Labor, 3-year on-site support.
|
|
HP ProLiant BL460c Gen8 E5-2640v2 1P 32GB-R P220i/512 FBWC Server
724085-B21
|
Processor(s)
|
(1) Intel® Xeon® E5-2640 v2 (2.0GHz/8-core/20MB/7.2GT-s QPI/95W, DDR3-1600,
HT, Turbo2- 3/3/3/3/3/3/4/5)
|
Cache
Memory
|
15MB (1x15MB) Level 3
cache
|
Memory
|
32GB
(2x 16GB) PC3L-12800R (DDR3-1600 Registered DIMMs at 1.35V)
NOTE:
Total of 16 DIMM slots. Only eight (8) usable with single processor.
|
Network Controller
|
HP
FlexFabric 10Gb 2-port 534FLB FlexibleLOM
|
Storage
Controller
|
HP Smart Array P220i
Controller with 512MB FBWC RAID 0,1
|
Hard
Drive
|
None ship standard
Supports
up to two (2) HP hot-plug SFF SAS/SATA/SDD drives
|
Internal
Storage
|
SAS: 2.0TB; SATA: 2.0TB;
SAS SSD: 1.6TB
|
Optical
Drive Bay
|
None
|
Expansion Slots
|
2
standard - Slot 1 supports Type A mezzanine Cards. Slot 2 supports Type A and
Type B mezzanine cards.
|
Management
|
HP
iLO Management Engine (standard)
|
Optional:
HP iLO Scale-out or HP Insight Control
|
Form
Factor
|
Up to eight (8) half-height
blades supported in the HP BladeSystem c3000 Enclosure
|
Up
to sixteen (16) half-height blades supported in HP BladeSystem c7000 Enclosure
|
Warranty
|
Server
warranty includes 3-year Parts, 3-year3-year Labor, 3-year on-site support.
|
|
HP ProLiant
BL460c Gen8 E5-2620v2 1P 16GB-R P220i/512 FBWC Server
724086-B21
|
Processor(s)
|
(1) Intel® Xeon® E5-2620 v2 (2.1GHz/6-core/15MB/7.2GT-s QPI/80W, DDR3-1600,
HT, Turbo2- 3/3/3/3/4/5)
|
Cache
Memory
|
15MB (1x15MB) Level 3
cache
|
Memory
|
16GB
(2x 8GB) PC3L-12800R (DDR3-1600) Registered DIMMs at 1. 35V)
NOTE:
Total of 16 DIMM slots. Only eight (8) usable with single processor.
|
Network Controller
|
HP
FlexFabric 10Gb 2-port 534FLB FlexibleLOM
|
Storage
Controller
|
Smart Array P220i
Controller with 512MB FBWC RAID 0,1
|
Hard
Drive
|
None ship standard
Supports
up to two (2) HP hot-plug SFF SAS/SATA/SDD drives
|
Internal
Storage
|
SAS: 2.4TB; SATA: 2.0TB;
SAS SSD: 1.6TB; SATA SSD: 1.6TB
|
Optical
Drive Bay
|
None
|
Expansion Slots
|
2
standard - Slot 1 supports Type A mezzanine Cards. Slot 2 supports Type A and
Type B mezzanine cards.
|
Management
|
HP
iLO Management Engine (standard)
|
Optional:
HP iLO Scale-out or HP Insight Control
|
Form
Factor
|
Up to eight (8) half-height
blades supported in the HP BladeSystem c3000 Enclosure
|
Up
to sixteen (16) half-height blades supported in HP BladeSystem c7000 Enclosure
|
Warranty
|
Server
warranty includes 3-year3-year Parts, 3-year Labor, 3-year on-site support.
|
|
HP ProLiant
BL460c Gen8 E5-2609v2 1P 16GB-L P220i/512 FBWC Server
724087-B21
|
Processor(s)
|
(1)Intel® Xeon® E5-2609 v2 (2.5GHz/4-core/10MB/6.4GT-s QPI/80W)
|
Cache Memory
|
10MB
(1x10MB) Level 3 cache
|
Memory
|
16GB
(2x 8GB) PC3L-12800R (DDR3-1600) Registered DIMMs at 1.35V)
NOTE:
Total of 16 DIMM slots. Only eight (8) usable with single processor.
|
Network Controller
|
HP
FlexFabric 10Gb 2-port 534FLB FlexibleLOM
|
Storage
Controller
|
HP Smart Array P220i
Controller with 512MB FBWC RAID 0,1
|
Hard
Drive
|
None ship standard
Supports
up to two (2) HP hot-plug SFF SAS/SATA/SDD drives
|
Internal
Storage
|
SAS: 2.4TB; SATA: 2.0TB;
SAS SSD: 1.6TB; SATA SSD: 1.6TB
|
Optical
Drive Bay
|
None
|
Expansion Slots
|
2
standard - Slot 1 supports Type A mezzanine Cards. Slot 2 supports Type A and
Type B mezzanine cards.
|
Management
|
HP
iLO Management Engine (standard)
|
Optional:
HP iLO Scale-out or HP Insight Control
|
Form
Factor
|
Up to eight (8) half-height
blades supported in the HP BladeSystem c3000 Enclosure
|
Up
to sixteen (16) half-height blades supported in HP BladeSystem c7000 Enclosure
|
Warranty
|
Server
warranty includes 3-year Parts, 3-year Labor, 3-year on-site support.
|
|
E5-2600
series Processors
|
HP ProLiant BL460c Gen8 E5-2670 2P 64GB-R P220i Server
666157-B21
|
Processor(s)
|
(2) Intel® Xeon® E5-2670 (2.6GHz/8-core/20MB/8.0GT-s QPI/115W, DDR3-1600,
HT, Turbo2- 4/4/5/5/6/6/7/7
|
Cache
Memory
|
20MB (1x20MB) Level 3
cache
|
Memory
|
64GB
(8x 8GB) PC3-12800R (DDR3-1600) Registered DIMMS at 1.5V)
NOTE:
Total of 16 DIMM slots.
|
Network
Controller
|
HP FlexFabric 10Gb
2-port 554FLB FlexibleLOM
|
Storage
Controller
|
HP Smart Array P220i
Controller with 512MB FBWC RAID 0,1
|
Hard
Drive
|
None ship standard
Supports up to two (2) HP hot-plug SFF SAS/SATA/SDD drives
|
Internal
Storage
|
SAS: 2.4TB; SATA: 2.0TB;
SAS SSD: 1.6TB; SATA SSD: 1.6TB
|
Optical
Drive Bay
|
None
|
Expansion Slots
|
2
standard - Slot 1 supports Type A mezzanine Cards. Slot 2 supports Type A and
Type B mezzanine cards.
|
Management
|
HP
iLO Management Engine (standard)
|
Optional:
HP iLO Scale-Out or HP Insight Control
|
Form
Factor
|
Up to eight (8) half-height
blades supported in the HP BladeSystem c3000 Enclosure
|
Up
to sixteen (16) half-height blades supported in HP BladeSystem c7000 Enclosure
|
Warranty
|
Server
warranty includes 3-year Parts, 3-year Labor, 3-year on-site support.
|
|
HP ProLiant
BL460c Gen8 E5-2660 2P 64GB-R P220i SFF Server
666158-B21
|
Processor(s)
|
(2) Intel® Xeon® E5-2660 (2.2GHz/8-core/20MB/8.0GT-s QPI/95W, DDR3-1600,
HT, Turbo2- 5/5/6/6/7/7/8/8)
|
Cache
Memory
|
20MB (1x20MB) Level 3
cache
|
Memory
|
64GB
(8x 8GB) PC3-12800R (DDR3-1600) Registered DIMMS at 1.5V)
NOTE:
Total of 16 DIMM slots.
|
Network
Controller
|
HP FlexFabric 10Gb
2-port 554FLB FlexibleLOM
|
Storage
Controller
|
HP Smart Array P220i
Controller with 512MB FBWC RAID 0,1
|
Hard
Drive
|
None ship standard
Supports up to two (2) HP hot-plug SFF SAS/SATA/SDD drives
|
Internal
Storage
|
SAS: 2.4TB; SATA: 2.0TB;
SAS SSD: 1.6TB ; SATA SSD: 1.6TB
|
Optical
Drive Bay
|
None
|
Expansion Slots
|
2
standard - Slot 1 supports Type A mezzanine Cards. Slot 2 supports Type A and
Type B mezzanine cards.
|
Management
|
HP
iLO Management Engine (standard)
|
Optional:
HP iLO Scale-out or HP Insight Control
|
Form
Factor
|
Up to eight (8) half-height
blades supported in the HP BladeSystem c3000 Enclosure
|
Up
to sixteen (16) half-height blades supported in HP BladeSystem c7000 Enclosure
|
Warranty
|
Server
warranty includes 3-year Parts, 3-year Labor, 3-year on-site support.
|
|
HP ProLiant
BL460c Gen8 E5-2650 1P 32GB-R P220i SFF Server
666159-B21
|
Processor(s)
|
(1) Intel® Xeon® E5-2650 (2.0GHz/8-core/20MB/8.0GT-s QPI/95W, DDR3-1600,
HT, Turbo2- 4/4/5/5/5/7/8/8)
|
Cache
Memory
|
20MB (1x20MB) Level 3
cache
|
Memory
|
32GB
(4x 8GB) PC3-12800R (DDR3-1600 Registered DIMMs at 1.5V)
NOTE:
Total of 16 DIMM slots. Only eight (8) usable with single processor.
|
Network Controller
|
HP
FlexFabric 10Gb 2-port 554FLB FlexibleLOM
|
Storage
Controller
|
HP Smart Array P220i
Controller with 512MB FBWC RAID 0,1
|
Hard
Drive
|
None ship standard
Supports up to two (2) HP hot-plug SFF SAS/SATA/SDD drives
|
Internal
Storage
|
SAS: 2.4TB; SATA: 2.0TB;
SAS SSD: 1.6TB; SATA SSD: 1.6TB
|
Optical
Drive Bay
|
None
|
Expansion Slots
|
2
standard - Slot 1 supports Type A mezzanine Cards. Slot 2 supports Type A and
Type B mezzanine cards.
|
Management
|
HP
iLO Management Engine (standard)
|
Optional:
HP iLO Scale-out or HP Insight Control
|
Form
Factor
|
Up to eight (8) half-height
blades supported in the HP BladeSystem c3000 Enclosure
|
Up
to sixteen (16) half-height blades supported in HP BladeSystem c7000 Enclosure
|
Warranty
|
Server
warranty includes 3-year Parts, 3-year Labor, 3-year on-site support.
|
|
HP ProLiant
BL460c Gen8 E5-2650L 1P 32GB-R P220i SFF Server
666163-B21
|
Processor(s)
|
(1) Intel® Xeon® E5-2650L (1.8GHz/8-core/20MB/8.0GT-s QPI/70W, DDR3-1600,
HT, Turbo2- 2/2/3/3/4/4/5/5)
|
Cache
Memory
|
20MB Level 3 cache
|
Memory
|
32GB
(4x 8GB) PC3L-10600R (DDR3-1333 Registered DIMMs at 1.35V)
NOTE:
Total of 16 DIMM slots. Only eight (8) usable with single processor.
|
Network Controller
|
HP
FlexFabric 10Gb 2-port 554FLB FlexibleLOM
|
Storage
Controller
|
HP Smart Array P220i
Controller with 512MB FBWC RAID 0,1
|
Hard
Drive
|
None ship standard
Supports up to two (2) HP hot-plug SFF SAS/SATA/SDD drives
|
Internal
Storage
|
SAS: 2.4TB; SATA: 2.0TB;
SAS SSD: 1.6TB; SATA SSD 1.6TB
|
Optical
Drive Bay
|
None
|
Expansion Slots
|
2
standard - Slot 1 supports Type A mezzanine Cards. Slot 2 supports Type A and
Type B mezzanine cards.
|
Management
|
HP
iLO Management Engine (standard)
|
Optional:
HP iLO Scale-out or HP Insight Control
|
Form
Factor
|
Up to eight (8) half-height
blades supported in the HP BladeSystem c3000 Enclosure
|
Up
to sixteen (16) half-height blades supported in HP BladeSystem c7000 Enclosure
|
Warranty
|
Server
warranty includes 3-year Parts, 3-year Labor, 3-year on-site support.
|
|
HP ProLiant BL460c Gen8 E5-2640 1P 32GB-R P220i SFF Server
666160-B21
|
Processor(s)
|
(1) Intel® Xeon® E5-2640 (2.5GHz/6-core/15MB/7.2GT-s QPI/95W, DDR3-1333,
HT, Turbo2- 3/3/4/4/5/5)
|
Cache
Memory
|
15MB (1x15MB) Level 3
cache
|
Memory
|
32GB
(4x 8GB) PC3L-10600R (DDR3-1333 Registered DIMMs at 1.35V)
NOTE:
Total of 16 DIMM slots. Only eight (8) usable with single processor.
|
Network Controller
|
HP
FlexFabric 10Gb 2-port 554FLB FlexibleLOM
|
Storage
Controller
|
HP Smart Array P220i
Controller with 512MB FBWC RAID 0,1
|
Hard
Drive
|
None ship standard
Supports up to two (2) HP hot-plug SFF SAS/SATA/SDD drives
|
Internal
Storage
|
SAS: 2.0TB; SATA: 2.0TB;
SAS SSD: 1.6TB
|
Optical
Drive Bay
|
None
|
Expansion Slots
|
2
standard - Slot 1 supports Type A mezzanine Cards. Slot 2 supports Type A and
Type B mezzanine cards.
|
Management
|
HP
iLO Management Engine (standard)
|
Optional:
HP iLO Scale-out or HP Insight Control
|
Form
Factor
|
Up to eight (8) half-height
blades supported in the HP BladeSystem c3000 Enclosure
|
Up
to sixteen (16) half-height blades supported in HP BladeSystem c7000 Enclosure
|
Warranty
|
Server
warranty includes 3-year Parts, 3-year3-year Labor, 3-year on-site support.
|
|
HP ProLiant
BL460c Gen8 E5-2620 1P 16GB-R P220i SFF Server
666161-B21
|
Processor(s)
|
(1) Intel® Xeon® E5-2620 (2.0GHz/6-core/15MB/7.2GT-s QPI/95W, DDR3-1333,
HT, Turbo2- 3/3/4/4/5/5)
|
Cache
Memory
|
15MB (1x15MB) Level 3
cache
|
Memory
|
16GB
(4x 4GB) PC3L-10600R (DDR3-1333) Registered DIMMs at 1.35V)
NOTE:
Total of 16 DIMM slots. Only eight (8) usable with single processor.
|
Network Controller
|
HP
FlexFabric 10Gb 2-port 554FLB FlexibleLOM
|
Storage
Controller
|
Smart Array P220i
Controller with 512MB FBWC RAID 0,1
|
Hard
Drive
|
None ship standard
Supports up to two (2) HP hot-plug SFF SAS/SATA/SDD drives
|
Internal
Storage
|
SAS: 2.4TB; SATA: 2.0TB;
SAS SSD: 1.6TB; SATA SSD: 1.6TB
|
Optical
Drive Bay
|
None
|
Expansion Slots
|
2
standard - Slot 1 supports Type A mezzanine Cards. Slot 2 supports Type A and
Type B mezzanine cards.
|
Management
|
HP
iLO Management Engine (standard)
|
Optional:
HP iLO Scale-out or HP Insight Control
|
Form
Factor
|
Up to eight (8) half-height
blades supported in the HP BladeSystem c3000 Enclosure
|
Up
to sixteen (16) half-height blades supported in HP BladeSystem c7000 Enclosure
|
Warranty
|
Server
warranty includes 3-year3-year Parts, 3-year Labor, 3-year on-site support.
|
|
HP ProLiant
BL460c Gen8 E5-2609 1P 16GB-R P220i SFF Server
666162-B21
|
Processor(s)
|
(1) Intel® Xeon® E5-2609 (2.4GHz/4-core/10MB/6.4GT-s QPI/80W)
|
Cache Memory
|
10MB
(1x10MB) Level 3 cache
|
Memory
|
16GB
(4x 4GB) PC3L-10600R (DDR3-1333) Registered DIMMs at 1.35V)
NOTE:
Total of 16 DIMM slots. Only eight (8) usable with single processor.
|
Network Controller
|
HP
FlexFabric 10Gb 2-port 554FLB FlexibleLOM
|
Storage
Controller
|
HP Smart Array P220i
Controller with 512MB FBWC RAID 0,1
|
Hard
Drive
|
None ship standard
Supports up to two (2) HP hot-plug SFF SAS/SATA/SDD drives
|
Internal
Storage
|
SAS: 2.4TB; SATA: 2.0TB;
SAS SSD: 1.6TB; SATA SSD: 1.6TB
|
Optical
Drive Bay
|
None
|
Expansion Slots
|
2
standard - Slot 1 supports Type A mezzanine Cards. Slot 2 supports Type A and
Type B mezzanine cards.
|
Management
|
HP
iLO Management Engine (standard)
|
Optional:
HP iLO Scale-out or HP Insight Control
|
Form
Factor
|
Up to eight (8) half-height
blades supported in the HP BladeSystem c3000 Enclosure
|
Up
to sixteen (16) half-height blades supported in HP BladeSystem c7000 Enclosure
|
Warranty
|
Server
warranty includes 3-year Parts, 3-year Labor, 3-year on-site support.
|
Smart Buys
HP ProLiant BL460c Gen8 E5-2670 2P Svr/S-Buy
742688-S01
|
Processor(s)
|
(2) Intel® Xeon® E5-2670 (2.60GHz/8-core/20MB/115W) Processor
|
Cache Memory
|
20MB (1x20MB) Level 3 cache
|
Memory
|
128GB (8 x 16GB) PC3-12800R (DDR3-1600) Registered DIMMs at 1.5V)
NOTE:
Total of 16 DIMM slots.
|
Network
Controller
|
HP FlexFabric
10Gb 2-port 554FLB FlexLOM
|
Storage
Controller
|
HP Smart Array
P220i Controller with 512MB FBWC RAID 0,1
|
Hard
Drive
|
None ship standard
Supports
up to two (2) HP hot-plug SFF SAS/SATA/SDD drives
|
Internal
Storage
|
SAS: 2.0TB; SATA:
2.0TB; SAS SSD: 1.6TB
|
Optical
Drive Bay
|
None
|
Expansion Slots
|
2
standard - Slot1supports Type A mezzanine Cards. Slot 2 supports Type A and Type
B mezzanine cards.
|
Management
|
iLO
Management Engine Standard
|
Form
Factor
|
Up to eight (8) half-height
blades supported in the HP BladeSystem c3000 Enclosure
|
Up
to sixteen (16) half-height blades supported in HP BladeSystem c7000 Enclosure
|
Warranty
|
Server
warranty includes 3 year Parts, 3 year Labor, 3-year on-site support.
|
|
HP ProLiant
BL460c Gen8 E5-2650 2P Svr/S-Buy
670656-S01
|
Processor(s)
|
(2) Intel® Xeon® E5-2650 (2.0GHz/8-core/20MB/95W), 64GB
|
Cache Memory
|
20MB (1x20MB) Level 3 cache
|
Memory
|
64GB (8x 8GB) PC3-12800R (DDR3-1600) Registered DIMMs at 1.5V)
NOTE:
Total of 16 DIMM slots.
|
Network
Controller
|
HP FlexFabric
10Gb 2-port 554FLB FlexLOM
|
Storage
Controller
|
HP Smart Array
P220i Controller with 512MB FBWC RAID 0,1
|
Hard
Drive
|
None ship standard
Supports up to two (2) HP hot-plug SFF SAS/SATA/SDD drives
|
Internal
Storage
|
SAS: 2.0TB; SATA:
2.0TB; SAS SSD: 1.6TB
|
Optical
Drive Bay
|
None
|
Expansion Slots
|
2
standard - Slot1supports Type A mezzanine Cards. Slot 2 supports Type A and Type
B mezzanine cards.
|
Management
|
iLO
Management Engine Standard
|
Form
Factor
|
Up to eight (8) half-height
blades supported in the HP BladeSystem c3000 Enclosure
|
Up
to sixteen (16) half-height blades supported in HP BladeSystem c7000 Enclosure
|
Warranty
|
Server
warranty includes 3 year Parts, 3 year Labor, 3-year on-site support.
|
|
HP ProLiant
BL460c Gen8 E5-2640 2P Svr/S-Buy
670657-S01
|
Processor(s)
|
(2) Intel® Xeon® E5-2640 (2.50GHz/6-core/15MB/95W)
|
Cache Memory
|
15MB (1x15MB) Level 3 cache
|
Memory
|
48GB (6x 8GB) PC3L-10600R (DDR3-1333) Registered DIMMs at 1.35V)
NOTE:
Total of 16 DIMM slots.
|
Network
Controller
|
HP FlexFabric
10Gb 2-port 554FLB FlexLOM
|
Storage
Controller
|
HP Smart Array
P220i Controller with 512MB FBWC RAID 0,1
|
Hard
Drive
|
None ship standard
Supports up to two (2) HP hot-plug SFF SAS/SATA/SDD drives
|
Internal
Storage
|
SAS: 2.0TB; SATA:
2.0TB; SAS SSD: 1.6TB
|
Optical
Drive Bay
|
None
|
Expansion Slots
|
2 standard - Slot1supports Type A mezzanine Cards. Slot 2 supports Type A and
Type B mezzanine cards.
|
Management
|
iLO Management Engine Standard
|
Form
Factor
|
Up to eight (8) half-height
blades supported in the HP BladeSystem c3000 Enclosure
|
Up
to sixteen (16) half-height blades supported in HP BladeSystem c7000 Enclosure
|
Warranty
|
Server
warranty includes 3 year Parts, 3 year Labor, 3-year on-site support.
|
|
HP ProLiant
BL460c Gen8 E5-2620 2P Svr/S-Buy
670658-S01
|
Processor(s)
|
(2) Intel® Xeon® E5-2620 (2.0GHz/6-core/15MB/95W)
|
Cache
Memory
|
15MB (1x15MB) Level
3 cache
|
Memory
|
32GB (4x 8GB) PC3L-10600R (DDR3-1333) Registered DIMMs at 1.35V)
NOTE:
Total of 16 DIMM slots.
|
Network
Controller
|
HP FlexFabric
10Gb 2-port 554FLB FlexLOM
|
Storage
Controller
|
HP Smart Array
P220i Controller with 512MB FBWC RAID 0,1
|
Hard
Drive
|
None ship standard
Supports up to two (2) HP hot-plug SFF SAS/SATA/SDD drives
|
Internal
Storage
|
SAS: 2.0TB; SATA:
2.0TB; SAS SSD: 1.6TB
|
Optical
Drive Bay
|
None
|
Expansion Slots
|
2 standard - Slot1supports Type A mezzanine Cards. Slot 2 supports Type A and
Type B mezzanine cards.
|
Management
|
iLO Management Engine Standard
|
Form
Factor
|
Up to eight (8) half-height
blades supported in the HP BladeSystem c3000 Enclosure
|
Up
to sixteen (16) half-height blades supported in HP BladeSystem c7000 Enclosure
|
Warranty
|
Server
warranty includes 3 year Parts, 3 year Labor, 3-year on-site support.
|
|
HP ProLiant BL460c Gen8 E5-2650v2 2P Svr/S-Buy
741446-S01
|
Processor(s)
|
(2) Intel® Xeon® E5-2650 v2 (2.6GHz/8-core/20MB/8.0GT-s QPI/95W, DDR3-1866,
HT, Turbo2- 4/4/4/4/5/6/7/8)
|
Cache
Memory
|
20MB (1x20MB) Level
3 cache
|
Memory
|
64GB (8x 8GB) Single Rank x4 PC3-14900R (DDR3-1866) Registered CAS-13 Memory
|
Network Controller
|
HP FlexFabric 10Gb 2-port 534FLB FlexibleLOM
|
Storage
Controller
|
HP Smart Array
P220i Controller with 512MB FBWC RAID 0,1
|
Hard
Drive
|
None ship standard
Supports
up to two (2) HP hot-plug SFF SAS/SATA/SDD drives
|
Internal
Storage
|
SAS: 2.0TB; SATA:
2.0TB; SAS SSD: 1.6TB
|
Optical
Drive Bay
|
None
|
Expansion Slots
|
2
standard - Slot1supports Type A mezzanine Cards. Slot 2 supports Type A and Type
B mezzanine cards.
|
Management
|
iLO
Management Engine Standard
|
Form
Factor
|
Up to eight (8) half-height
blades supported in the HP BladeSystem c3000 Enclosure
|
Up
to sixteen (16) half-height blades supported in HP BladeSystem c7000 Enclosure
|
Warranty
|
Server
warranty includes 3 year Parts, 3 year Labor, 3-year on-site support.
|
|
HP ProLiant
BL460c Gen8 E5-2640v2 2P Svr/S-Buy
741447-S01
|
Processor(s)
|
(2) Intel® Xeon® E5-2640 v2 (2.0GHz/8-core/20MB/7.2GT-s QPI/95W, DDR3-1600,
HT, Turbo2- 3/3/3/3/3/3/4/5)
|
Cache
Memory
|
20MB (1x20MB) Level
3 cache
|
Memory
|
48GB (6x 8GB) Single Rank x4 PC3L-12800R (DDR3-1600) Registered CAS-11 Low
Voltage Memory
|
Network
Controller
|
HP FlexFabric
10Gb 2-port 534FLB FlexibleLOM
|
Storage
Controller
|
HP Smart Array
P220i Controller with 512MB FBWC RAID 0,1
|
Hard
Drive
|
None ship standard
Supports
up to two (2) HP hot-plug SFF SAS/SATA/SDD drives
|
Internal
Storage
|
SAS: 2.0TB; SATA:
2.0TB; SAS SSD: 1.6TB
|
Optical
Drive Bay
|
None
|
Expansion Slots
|
2
standard - Slot1supports Type A mezzanine Cards. Slot 2 supports Type A and Type
B mezzanine cards.
|
Management
|
iLO
Management Engine Standard
|
Form
Factor
|
Up to eight (8) half-height
blades supported in the HP BladeSystem c3000 Enclosure
|
Up
to sixteen (16) half-height blades supported in HP BladeSystem c7000 Enclosure
|
Warranty
|
Server
warranty includes 3 year Parts, 3 year Labor, 3-year on-site support.
|
|
HP ProLiant
BL460c Gen8 E5-2620v2 2P Svr/S-Buy
741448-S01
|
Processor(s)
|
(2) Intel® Xeon® E5-2620 v2 (2.1GHz/6-core/15MB/7.2GT-s QPI/80W, DDR3-1600,
HT, Turbo2- 3/3/3/3/4/5)
|
Cache
Memory
|
15MB (1x15MB) Level
3 cache
|
Memory
|
32GB (4x 8GB) Single Rank x4 PC3L-12800R (DDR3-1600) Registered CAS-11 Low
Voltage Memory
|
Network
Controller
|
HP FlexFabric
10Gb 2-port 534FLB FlexibleLOM
|
Storage
Controller
|
HP Smart Array
P220i Controller with 512MB FBWC RAID 0,1
|
Hard
Drive
|
None ship standard
Supports
up to two (2) HP hot-plug SFF SAS/SATA/SDD drives
|
Internal
Storage
|
SAS: 2.0TB; SATA:
2.0TB; SAS SSD: 1.6TB
|
Optical
Drive Bay
|
None
|
Expansion Slots
|
2 standard - Slot1supports Type A mezzanine Cards. Slot 2 supports Type A and
Type B mezzanine cards.
|
Management
|
iLO Management Engine Standard
|
Form
Factor
|
Up to eight (8) half-height
blades supported in the HP BladeSystem c3000 Enclosure
|
Up
to sixteen (16) half-height blades supported in HP BladeSystem c7000 Enclosure
|
Warranty
|
Server
warranty includes 3 year Parts, 3 year Labor, 3-year on-site support.
|
Configuration Information - Factory Integrated Models
NOTE:
This section lists some of the steps required to configure a Factory Integrated
Model (configure-to-order or CTO server). To ensure only valid configurations
are ordered, HP recommends the use of an HP approved configurator. Contact your
local sales representative for information on CTO product offerings and requirements.
NOTE:
Configure-to-order server blades must start with a CTO Blade Server.
NOTE:
FIO indicates that this option is only available as a factory installable option.
NOTE:
All Factory Integrated Models will be populated with sufficient hard drive blanks
based on the number of initial hard drives ordered with the server.
|
Step
1: Base Server Blade Configuration (Select a configurable Blade)
|
Models
|
HP
ProLiant BL460c Gen8 E5-v2 10Gb FlexibleLOM Configure-to-order Blade Server
|
735151-B21
|
Configurable
Models ship with:
|
|
One
(1) FlexibleLOM connector providing a choice for one (1) of the supported 10Gb
FlexibleLOMs (see Step 2)
Two (2) HP small form factor hot-plug SAS/SATA/SSD
hard drive bays
Two (2) x16 PCIe I/O expansion slots (one Type A, one Type
A/B)
One (1) integrated USB connector and one (1) MicroSDHC connector
One
(1) TPM connector
HP iLO Management Engine (standard)
|
|
HP
ProLiant BL460c Gen8 10Gb FlexibleLOM Configure-to-order Blade Server
|
641016-B21
|
Configurable
Models ship with:
|
|
One
(1) FlexibleLOM connector providing a choice for one (1) of the supported 10Gb
FlexibleLOMs (see Step 2)
One (1) HP Smart Array P220i Controller with 512MB
FBWC and RAID 0 and 1 support
Two (2) HP small form factor hot-plug SAS/SATA/SSD
hard drive bays
Two (2) x16 PCIe I/O expansion slots (one Type A, one Type
A/B)
One (1) integrated USB connector and one (1) MicroSDHC connector
One
(1) TPM connector
HP iLO Management Engine (standard)
NOTE:
The HP ProLiant BL460c Gen8 10Gb FlexibleLOM Configure-to-order Blade Server (641016-B21)
cannot be configured the new 1866MHz HP Smart Memory or the new 1600MHz Low Voltage
(1.35v) HP Smart Memory.
NOTE: The HP Smart Array P220i Controller
FIO Kit (690164-B21) comes included with the HP ProLiant BL460c Gen8 10Gb FlexibleLOM
Configure-to-order Blade Server (641016-B21). However, when choosing the HP ProLiant
BL460c Gen8 E5-v2 10Gb FlexibleLOM Configure-to-order Blade Server (735151-B21),
the HP Smart Array P220i Controller FIO Kit (690164-B21) must be added separately
as part of the Server Blade Configuration Process.
|
|
|
Step
2: Choose Required Options (one of the following from each list unless otherwise
noted)
|
HP
Processors
|
NOTE:
All configure-to-order processor kits (i.e. xxxxxx-L21) contain one (1) processor.
NOTE:
If two processors are desired, select one xxxxxx-L21 here in Step 2 and one xxxxxx-B21
in Step 4.
|
|
E5-2600 v2 series
Processors
|
|
HP BL460c Gen8 Intel®
Xeon® E5-2697v2 (2.7GHz/12-core/30MB/130W) FIO Processor Kit
|
718045-L21
|
HP BL460c Gen8 Intel®
Xeon® E5-2695v2 (2.4GHz/12-core/30MB/115W) FIO Processor Kit
|
718054-L21
|
HP BL460c Gen8 Intel®
Xeon® E5-2690v2 (3.0GHz/10-core/25MB/130W) FIO Processor Kit
|
718055-L21
|
HP BL460c Gen8 Intel®
Xeon® E5-2680v2 (2.8GHz/10-core/25MB/115W) FIO Processor Kit
|
718056-L21
|
HP BL460c Gen8 Intel®
Xeon® E5-2670v2 (2.5GHz/10-core/25MB/115W) FIO Processor Kit
|
718057-L21
|
HP BL460c Gen8 Intel®
Xeon® E5-2667v2 (3.3GHz/8-core/25MB/130W) FIO Processor Kit
|
718366-L21
|
HP BL460c
Gen8 Intel® Xeon® E5-2660v2 (2.2GHz/10-core/25MB/95W) FIO Processor Kit
|
718058-L21
|
HP BL460c Gen8 Intel®
Xeon® E5-2650v2 (2.6GHz/8-core/20MB/95W) FIO Processor Kit
|
718358-L21
|
HP BL460c
Gen8 Intel® Xeon® E5-2650Lv2 (1.7GHz/10-core/25MB/70W) FIO Processor Kit
|
718364-L21
|
HP
BL460c Gen8 Intel® Xeon® E5-2643v2 (3.5GHz/6-core/25MB/130W) FIO Processor
Kit
|
718367-L21
|
HP BL460c Gen8 Intel®
Xeon® E5-2640v2 (2.0GHz/8-core/20MB/95W) FIO Processor Kit
|
718359-L21
|
HP BL460c Gen8 Intel®
Xeon® E5-2637v2 (3.5GHz/4-core/15MB/130W) FIO Processor Kit
|
718368-L21
|
HP
BL460c Gen8 Intel® Xeon® E5-2630v2 (2.6GHz/6-core/15MB/80W) FIO Processor
Kit
|
718360-L21
|
HP BL460c Gen8 Intel®
Xeon® E5-2630Lv2 (2.4GHz/6-core/15MB/60W) FIO Processor Kit
|
718365-L21
|
HP BL460c Gen8
Intel® Xeon® E5-2620v2 (2.1GHz/6-core/15MB/80W) FIO Processor Kit
|
718361-L21
|
HP BL460c Gen8 Intel®
Xeon® E5-2609v2 (2.5GHz/4-core/10MB/80W) FIO Processor Kit
|
718362-L21
|
HP
BL460c Gen8 Intel® Xeon® E5-2603v2 (1.8GHz/4-core/10MB/80W) FIO Processor
Kit
|
718363-L21
|
E5-2600
series Processors
|
|
HP BL460c Gen8 Intel®
Xeon® E5-2690 (2.9GHz/8-core/20MB/135W) FIO Processor Kit
|
662076-L21
|
HP
BL460c Gen8 Intel® Xeon® E5-2680 (2.7GHz/8-core/20MB/130W) FIO Processor
Kit
|
662063-L21
|
HP
BL460c Gen8 Intel® Xeon® E5-2670 (2.6GHz/8-core/20MB/115W) FIO Processor
Kit
|
662064-L21
|
HP
BL460c Gen8 Intel® Xeon® E5-2667 (2.9GHz/6-core/15MB/130W) FIO Processor
Kit
|
667804-L21
|
HP
BL460c Gen8 Intel® Xeon® E5-2665 (2.4GHz/8-core/20MB/115W) FIO Processor
Kit
|
667803-L21
|
HP
BL460c Gen8 Intel® Xeon® E5-2660 (2.2GHz/8-core/20MB/95W) FIO Processor
Kit
|
662065-L21
|
HP
BL460c Gen8 Intel® Xeon® E5-2650 (2.0GHz/8-core/20MB/95W) FIO Processor
Kit
|
662066-L21
|
HP
BL460c Gen8 Intel® Xeon® E5-2650L (1.8GHz/8-core/20MB/70W) FIO Processor
Kit
|
662078-L21
|
HP
BL460c Gen8 Intel® Xeon® E5-2643 (3.3GHz/4-core/10MB/130W) FIO Processor
Kit
|
662072-L21
|
HP
BL460c Gen8 Intel® Xeon® E5-2640 (2.5GHz/6-core/15MB/95W) FIO Processor
Kit
|
662067-L21
|
HP
BL460c Gen8 Intel® Xeon® E5-2637 (3.0GHz/2-core/5MB/80W) FIO Processor
Kit
|
662077-L21
|
HP
BL460c Gen8 Intel® Xeon® E5-2630 (2.3GHz/6-core/15MB/95W) FIO Processor
Kit
|
662068-L21
|
HP
BL460c Gen8 Intel® Xeon® E5-2630L (2.0GHz/6-core/15MB/60W) FIO Processor
Kit
|
662079-L21
|
HP
BL460c Gen8 Intel® Xeon® E5-2620 (2.0GHz/6-core/15MB/95W) FIO Processor
Kit
|
662069-L21
|
HP
BL460c Gen8 Intel® Xeon® E5-2609 (2.4GHz/4-core/10MB/80W) FIO Processor
Kit
|
662070-L21
|
HP
BL460c Gen8 Intel® Xeon® E5-2603 (1.8GHz/4-core/10MB/80W) FIO Processor
Kit
|
667805-L21
|
NOTE:
The Intel Xeon E5-2600 Processor Family cannot be configured with the new 1866MHz
HP Smart Memory or the new 1600MHz Low Voltage (1.35v) HP Smart Memory.
NOTE:
DIMM slots 4 and 5 are not accessible when either the E5-2690, the E5-2643, the
E5-2643 v2, the E5-2637 v2, or the E5-2667 v2 is used. In a 2 processor configuration,
there are twelve (12) total available DIMM slots.
NOTE: For the maximum
supported memory speeds for each processor listed above, please reference the
'Memory Speed by Processor Model' table in the Memory section of the QuickSpecs.
NOTE:
HT indicates that the processor model supports Intel® Hyper-Threading Technology.
NOTE:
Turbo indicates the maximum potential frequency increment when using Intel®
Turbo Boost Technology, with 8, 7, 6, 5, 4, 3, 2 or 1 core(s) active.
NOTE:
DDR3 speed is the maximum memory speed of the processor. Actual memory speed may
depend on the quantity and type of DIMMs installed.
NOTE: Up to 2 processors
supported. Mixing different processor models is not supported.
NOTE:
For the Intel® C600 Chipset E5-2600 Series, the letter preceding the model
number indicates the Product Line (E3, E5, E7); 2600x, 2 = number of CPUs in a
Node, 6 is socket/segment designation, 00 = Processor SKU, and x = L for low power
SKUs.
NOTE: The BL460c Gen8 supports one or two processors.
NOTE:
The BL460c Gen8 includes two I/O mezzanine expansion slots. A processor must be
installed in processor slot 1 for access to the first mezzanine expansion slot
(expansion slot 1). A processor must be installed in processor slot 2 for access
to the second mezzanine expansion slot (expansion slot 2).
NOTE: All
processors within the server must be identical.
NOTE: All processors
support Intel® Hyper-Threading and Intel® Turbo Boost Technologies except
the E5-2603 and E5-2609.
NOTE: The letter "L" following the
model number indicates denotes lower wattage.
NOTE: The processor model
as well as the memory configuration determines the maximum speed memory can operate.
Please see the see the "Memory" section later in this document.
NOTE:
The Intel Xeon E5-2620 processor does not support DIMMs at 1.35V. Using the HP
RBSU, 1.35V DIMMs can be changed to operate at 1.5V.
NOTE: When HP 24GB
(1x24GB) Three Rank x4 PC3L-10600R (DDR3-1333) Registered CAS-9 Low Voltage FIO
Memory Kits are used with any processors except the E5-2690, the E5-2643, the
E5-2637 v2, the E5-2643 v2, or the E5-2667 v2 all 16 DIMM slots on the BL460c
Gen8 must be fully populated with these 24GB DIMMs. When HP 24GB (1x24GB) Three
Rank x4 PC3L-10600R (DDR3-1333) Registered CAS-9 Low Voltage FIO Memory Kits are
used with either the E5-2690, the E5-2643, the E5-2637 v2, the E5-2643 v2, or
the E5-2667 v2, all 12 available DIMM slots on the BL460c Gen8 must be fully populated
with these 24GB DIMMs.
|
|
HP
Memory
|
NOTE:
The HP ProLiant BL460c Gen8 10Gb FlexibleLOM Configure-to-order Blade Server (641016-B21)
cannot be configured the new 1866MHz HP Smart Memory or the new 1600MHz Low Voltage
(1.35v) HP Smart Memory.
NOTE: HP memory from previous generation servers
are not qualified or warranted with this HP ProLiant BL460c Server. HP SmartMemory
is required to realize the memory performance improvements and enhanced functionality
listed in this document for Gen8. For additional information, please see the HP
SmartMemory QuickSpecs at: https://h18000.www1.hp.com/products/quickspecs/14225_na/14225_na.html
NOTE:
LRDIMM, RDIMM and UDIMMs are all distinct memory technologies and cannot be mixed
within a server. The majority of ProLiant Gen8 servers support RDIMM, UDIMM and
LRDIMM.
NOTE: A minimum of one DIMM is required per server.
NOTE:
For additional memory rules and guidelines, see the "Memory" section
later in this document.
NOTE: When HP 24GB (1x24GB) Three Rank x4 PC3L-10600R
(DDR3-1333) Registered CAS-9 Low Voltage FIO Memory Kits are used with any processors
except the E5-2690, the E5-2643, the E5-2637 v2, the E5-2643 v2, or the E5-2667
v2 all 16 DIMM slots on the BL460c Gen8 must be fully populated with these 24GB
DIMMs. When HP 24GB (1x24GB) Three Rank x4 PC3L-10600R (DDR3-1333) Registered
CAS-9 Low Voltage FIO Memory Kits are used with either the E5-2690, the E5-2643,
the E5-2637 v2 the E5-2643 v2, or the E5-2667 v2, all 12 available DIMM slots
on the BL460c Gen8 must be fully populated with these 24GB DIMMs.
NOTE:
The internal USB 2.0 Port is not available when the HP 24GB (1x24GB) Three Rank
x4 PC3L-10600R (DDR3-1333) Registered CAS-9 Low Voltage FIO Memory Kits (700404-B21)
are used.
|
|
HP SmartMemory
|
|
Registered DIMMs
(RDIMMs) - E5-2600 v2 series Processors
|
|
HP 4GB (1x4GB) Single
Rank x4 PC3L-12800R (DDR3-1600) Registered CAS-11 Low Voltage Memory Kit
|
713981-B21
|
HP 4GB (1x4GB) Single
Rank x4 PC3-14900R (DDR3-1866) Registered CAS-13 Memory Kit
|
708637-B21
|
HP 8GB (1x8GB) Single
Rank x4 PC3L-12800R (DDR3-1600) Registered CAS-11 Low Voltage Memory Kit
|
731765-B21
|
HP 8GB (1x8GB) Single
Rank x4 PC3-14900R (DDR3-1866) Registered CAS-13 Memory Kit
|
731761-B21
|
HP 16GB (1x16GB)
Dual Rank x4 PC3L-12800R (DDR3-1600) Registered CAS-11 Low Voltage Memory Kit
|
713985-B21
|
HP 16GB (1x16GB)
Dual Rank x4 PC3-14900R (DDR3-1866) Registered CAS-13 Memory Kit
|
708641-B21
|
HP 24 GB (1x24GB) Three Rank x4 PC3L-10600R (DDR3-1333) Registered CAS-9 Low Voltage
FIO Memory Kit
|
716324-B21
|
Registered DIMMs
(RDIMMs) - E5-2600 series Processors
|
|
HP 4GB (1x4GB) Single
Rank x4 PC3L-10600R (DDR3-1333) Registered CAS-9 Low Voltage Memory Kit
|
647893-B21
|
HP 4GB (1x4GB) Single
Rank x4 PC3-12800R (DDR3-1600) Registered CAS-11 Memory Kit
|
647895-B21
|
HP 8GB (1x8GB) Dual
Rank x4 PC3L-10600R (DDR3-1333) Registered CAS-9 Low Voltage Memory Kit
|
647897-B21
|
HP 8GB (1x8GB) Single
Rank x4 PC3-12800R (DDR3-1600) Registered CAS-11 Memory Kit
|
647899-B21
|
HP 8GB (1x8GB) Dual
Rank x4 PC3-12800R (DDR3-1600) Registered CAS-11 Memory Kit
|
690802-B21
|
HP 16GB (1x16GB)
Dual Rank x4 PC3L-10600R (DDR3-1333) Registered CAS-9 Low Voltage Memory Kit
|
647901-B21
|
HP
16GB (1x16GB) Dual Rank x4 PC3-12800R (DDR3-1600) Registered CAS-11 Memory Kit
|
672631-B21
|
HP
24 GB (1x24GB) Three Rank x4 PC3L-10600R (DDR3-1333) Registered CAS-9 Low Voltage
FIO Memory Kit
|
716324-B21
|
Unbuffered
with ECC DIMMs (UDIMMs) - E5-2600 v2 series Processors
|
|
HP
4GB (1x4GB) Dual Rank x8 PC3L-12800E (DDR3-1600) Unbuffered CAS-11 Low Voltage
Memory Kit
|
713977-B21
|
HP
4GB (1x4GB) Dual Rank x8 PC3-14900E (DDR3-1866) Unbuffered CAS-13 Memory Kit
|
708633-B21
|
HP
8GB (1x8GB) Dual Rank x8 PC3L-12800E (DDR3-1600) Unbuffered CAS-11 Low Voltage
Memory Kit
|
713979-B21
|
HP
8GB (1x8GB) Dual Rank x8 PC3-14900E (DDR3-1866) Unbuffered CAS-13 Memory Kit
|
708635-B21
|
Unbuffered
with ECC DIMMs (UDIMMs) - E5-2600 series Processors
|
|
HP
2GB (1x2GB) Single Rank x8 PC3-12800E (DDR3-1600) Unbuffered CAS-11 Memory Kit
|
669320-B21
|
HP
2GB (1x2GB) Single Rank x8 PC3L-10600E (DDR3-1333) Unbuffered CAS-9 Low Voltage
Memory Kit
|
647905-B21
|
HP
4GB (1x4GB) Dual Rank x8 PC3-12800E (DDR3-1600) Unbuffered CAS-11 Memory Kit
|
669322-B21
|
HP
4GB (1x4GB) Dual Rank x8 PC3L-10600E (DDR3-1333) Unbuffered CAS-9 Low Voltage
Memory Kit
|
647907-B21
|
HP
8GB (1x8GB) Dual Rank x8 PC3-12800E (DDR3-1600) Unbuffered CAS-11 Memory Kit
|
669324-B21
|
HP
8GB (1x8GB) Dual Rank x8 PC3L-10600E (DDR3-1333) Unbuffered CAS-9 Low Voltage
Memory Kit
|
647909-B21
|
Load
Reduced DIMMs (LRDIMMs) - E5-2600 v2 series Processors
|
|
HP
32GB (1x32GB) Quad Rank x4 PC3-14900L (DDR3-1866) Load Reduced CAS-13 Memory Kit
|
708643-B21
|
Load Reduced DIMMs
(LRDIMMs) - E5-2600 series Processors
|
|
HP 32GB (1x32GB)
Quad Rank x4 PC3L-10600L (DDR3-1333) Load Reduced CAS-9 Low Voltage Memory Kit
|
647903-B21
|
NOTE:
All DDR3 memory option kits consist of one DIMM per kit. For detailed memory configuration
rules and guidelines, please use the Online DDR3 Memory Configuration Tool: www.hp.com/go/ddr3memory-configurator.
NOTE:
Depending on the memory configuration and processor model, 1600MHz and 1333MHz
memory may operate at a lower speed. Please see the see the "Memory"
section later in this document and the Online Memory Configuration Tool for details
at: www.hp.com/go/ddr3memory-configurator.
NOTE:
For additional memory rules and guidelines, see the "Memory" section
later in this document.
NOTE: For more information on ProLiant Energy
Efficient Features, see: www.hp.com/go/proliant-energy-efficient
NOTE:
PC3L is a low voltage memory.
|
|
HP
Networking
|
FlexibleLOM
Adapters
NOTE: The server requires
one (1) FlexibleLOM that is installed in the FlexibleLOM connectors. All FlexibleLOMs
are dual port: One port is routed to interconnect module bay 1 and the other to
bay 2.
|
|
10Gb FlexibleLOM
Adapters
|
|
HP Ethernet 10Gb
2-port 560FLB FIO Adapter
|
684214-B21
|
HP
FlexFabric 10Gb 2-port 554FLB FIO Adapter
|
684212-B21
|
HP
FlexFabric 10Gb 2-port 534FLB FIO Adapter
|
700742-B21
|
HP Flex-10 10Gb
2-port 530FLB FIO Adapter
|
684211-B21
|
NOTE:
Please see the QuickSpecs for Technical Specifications and additional information:
www.hp.com/go/ProLiantNICs
|
|
|
Step
3: Choose Additional Factory Integration Options
|
HP Insight Software
|
HP
Insight Control including 1yr 24x7 Support ProLiant ML/DL/BL-bundle Single Server
FIO License
|
C6N36A
|
NOTE:
The HP Smart Array P220i Controller FIO Kit (690164-B21) comes included with the
HP ProLiant BL460c Gen8 10Gb FlexibleLOM Configure-to-order Blade Server (641016-B21).
However when choosing the HP ProLiant BL460c Gen8 E5-v2 10Gb FlexibleLOM Configure-to-order
Blade Server (735151-B21), the HP Smart Array P220i Controller FIO Kit (690164-B21)
must be added separately as part of the Server Blade Configuration Process.
|
|
HP
Storage Controllers
|
HP
Smart Array P220i Controller FIO Kit
|
690164-B21
|
HP
Storage Blades
|
HP
D2220sb Configure-to-order Storage Blade
|
QW918A
|
|
Step 4: Choose
Additional Options for Factory Integration
|
NOTE: For additional options, please refer to the "Core Options" and
"Additional Options" section below. For additional options, including server blade
enclosures interconnect, mezzanine options and power subsystem options; please
see the Core Options and Additional sections below; or the following:
|
Core Options
HP
Processors
|
E5-2600 v2 series Processors
|
|
HP BL460c Gen8 Intel® Xeon®
E5-2697v2 (2.7GHz/12-core/30MB/130W) Processor Kit
|
718045-B21
|
HP BL460c Gen8 Intel® Xeon®
E5-2695v2 (2.4GHz/12-core/30MB/115W) Processor Kit
|
718054-B21
|
HP BL460c Gen8 Intel® Xeon®
E5-2690v2 (3.0GHz/10-core/25MB/130W) Processor Kit
|
718055-B21
|
HP BL460c Gen8 Intel® Xeon®
E5-2680v2 (2.8GHz/10-core/25MB/115W) Processor Kit
|
718056-B21
|
HP BL460c Gen8 Intel® Xeon®
E5-2670v2 (2.5GHz/10-core/25MB/115W) Processor Kit
|
718057-B21
|
HP BL460c Gen8 Intel® Xeon®
E5-2667v2 (3.3GHz/8-core/25MB/130W) Processor Kit
|
718366-B21
|
HP BL460c Gen8 Intel® Xeon®
E5-2660v2 (2.2GHz/10-core/25MB/95W) Processor Kit
|
718058-B21
|
HP BL460c Gen8 Intel® Xeon®
E5-2650v2 (2.6GHz/8-core/20MB/95W) Processor Kit
|
718358-B21
|
HP
BL460c Gen8 Intel® Xeon® E5-2650Lv2 (1.7GHz/10-core/25MB/70W) Processor
Kit
|
718364-B21
|
HP BL460c Gen8 Intel® Xeon®
E5-2643v2 (3.5GHz/6-core/25MB/130W) Processor Kit
|
718367-B21
|
HP
BL460c Gen8 Intel® Xeon® E5-2640v2 (2.0GHz/8-core/20MB/95W) Processor
Kit
|
718359-B21
|
HP BL460c Gen8 Intel® Xeon®
E5-2637v2 (3.5GHz/4-core/15MB/130W) Processor Kit
|
718368-B21
|
HP
BL460c Gen8 Intel® Xeon® E5-2630v2 (2.6GHz/6-core/15MB/80W) Processor
Kit
|
718360-B21
|
HP BL460c Gen8 Intel®
Xeon® E5-2630Lv2 (2.4GHz/6-core/15MB/60W) Processor Kit
|
718365-B21
|
HP
BL460c Gen8 Intel® Xeon® E5-2620v2 (2.1GHz/6-core/15MB/80W) Processor
Kit
|
718361-B21
|
HP BL460c Gen8 Intel® Xeon®
E5-2609v2 (2.5GHz/4-core/10MB/80W) Processor Kit
|
718362-B21
|
HP
BL460c Gen8 Intel® Xeon® E5-2603v2 (1.8GHz/4-core/10MB/80W) Processor
Kit
|
718363-B21
|
E5-2600
series Processors
|
|
HP
BL460c Gen8 Intel® Xeon® E5-2690 (2.9GHz/8-core/20MB/135W) Processor Kit
|
662076-B21
|
HP
BL460c Gen8 Intel® Xeon® E5-2680 (2.7GHz/8-core/20MB/130W) Processor Kit
|
662063-B21
|
HP
BL460c Gen8 Intel® Xeon® E5-2670 (2.6GHz/8-core/20MB/115W) Processor Kit
|
662064-B21
|
HP
BL460c Gen8 Intel® Xeon® E5-2667 (2.9GHz/6-core/15MB/130W) Processor Kit
|
667804-B21
|
HP
BL460c Gen8 Intel® Xeon® E5-2665 (2.4GHz/8-core/20MB/115W) Processor Kit
|
667803-B21
|
HP
BL460c Gen8 Intel® Xeon® E5-2660 (2.2GHz/8-core/20MB/95W) Processor Kit
|
662065-B21
|
HP
BL460c Gen8 Intel® Xeon® E5-2650 (2.0GHz/8-core/20MB/95W) Processor Kit
|
662066-B21
|
HP
BL460c Gen8 Intel® Xeon® E5-2650L (1.8GHz/8-core/20MB/70W) Processor Kit
|
662078-B21
|
HP
BL460c Gen8 Intel® Xeon® E5-2643 (3.3GHz/4-core/10MB/130W) Processor Kit
|
662072-B21
|
HP
BL460c Gen8 Intel® Xeon® E5-2640 (2.5GHz/6-core/15MB/95W) Processor Kit
|
662067-B21
|
HP
BL460c Gen8 Intel® Xeon® E5-2637 (3.0GHz/2-core/5MB/80W) Processor Kit
|
662077-B21
|
HP
BL460c Gen8 Intel® Xeon® E5-2630 (2.3GHz/6-core/15MB/95W) Processor Kit
|
662068-B21
|
HP
BL460c Gen8 Intel® Xeon® E5-2630L (2.0GHz/6-core/15MB/60W) Processor Kit
|
662079-B21
|
HP
BL460c Gen8 Intel® Xeon® E5-2620 (2.0GHz/6-core/15MB/95W) Processor Kit
|
662069-B21
|
HP
BL460c Gen8 Intel® Xeon® E5-2609 (2.4GHz/4-core/10MB/80W) Processor Kit
|
662070-B21
|
HP
BL460c Gen8 Intel® Xeon® E5-2603 (1.8GHz/4-core/10MB/80W) Processor Kit
|
667805-B21
|
NOTE:
The Intel Xeon E5-2600 Processor Family cannot be configured with the new 1866MHz
HP Smart Memory or the new 1600MHz Low Voltage (1.35v) HP Smart Memory.
NOTE:
DIMM slots 4 and 5 are not accessible when either the E5-2690, the E5-2643, the
E5-2643 v2, the E5-2637 v2, or the E5-2667 v2 is used. In a 2 processor configuration,
there are twelve (12) total available DIMM slots
NOTE: For the maximum
supported memory speeds for each processor listed above, please reference the
'Memory Speed by Processor Model' table in the Memory section of the QuickSpecs.
NOTE:
HT indicates that the processor model supports Intel® Hyper-Threading Technology.
NOTE:
Turbo indicates the maximum potential frequency increment when using Intel®
Turbo Boost Technology, with 8, 7, 6, 5, 4, 3, 2 or 1 core(s) active.
NOTE:
DDR3 speed is the maximum memory speed of the processor. Actual memory speed may
depend on the quantity and type of DIMMs installed.
NOTE: Up to 2 processors
supported. Mixing different processor models is not supported.
NOTE:
For the Intel® C600 Chipset E5-2600 Series, the letter preceding the model
number indicates the Product Line (E3, E5, E7); 2600x, 2 = number of CPUs in a
Node, 6 is socket/segment designation, 00 = Processor SKU, and x = L for low power
SKUs.
NOTE: The BL460c Gen8 supports one or two processors.
NOTE:
The BL460c Gen8 includes two I/O mezzanine expansion slots. A processor must be
installed in processor slot 1 for access to the first mezzanine expansion slot
(expansion slot 1). A processor must be installed in processor slot 2 for access
to the second mezzanine expansion slot (expansion slot 2).
NOTE: All
processors within the server must be identical.
NOTE: All processors
support Intel® Hyper-Threading and Intel® Turbo Boost Technologies except
the E5-2603 and E5-2609.
NOTE: The letter "L" following the
model number indicates denotes lower wattage.
NOTE: The processor model
as well as the memory configuration determines the maximum speed memory can operate.
Please see the see the "Memory" section later in this document.
NOTE:
The Intel Xeon E5-2620 processor does not support DIMMs at 1.35V. Using the HP
RBSU, 1.35V DIMMs can be changed to operate at 1.5V.
NOTE: When HP 24GB
(1x24GB) Three Rank x4 PC3L-10600R (DDR3-1333) Registered CAS-9 Low Voltage FIO
Memory Kits are used with any processors except the E5-2690, the E5-2643, the
E5-2637 v2, the E5-2643 v2, or the E5-2667 v2 all 16 DIMM slots on the BL460c
Gen8 must be fully populated with these 24GB DIMMs. When HP 24GB (1x24GB) Three
Rank x4 PC3L-10600R (DDR3-1333) Registered CAS-9 Low Voltage FIO Memory Kits are
used with either the E5-2690, the E5-2643, the E5-2637 v2, the E5-2643 v2, or
the E5-2667 v2, all 12 available DIMM slots on the BL460c Gen8 must be fully populated
with these 24GB DIMMs.
|
|
|
HP
Memory
|
NOTE:
The HP ProLiant BL460c Gen8 10Gb FlexibleLOM Configure-to-order Blade Server (641016-B21)
cannot be configured the new 1866MHz HP Smart Memory or the new 1600MHz Low Voltage
(1.35v) HP Smart Memory.
NOTE: HP memory from previous generation servers
are not qualified or warranted with this HP ProLiant BL460c Gen8 Server. HP SmartMemory
is required to realize the memory performance improvements and enhanced functionality
listed in this document for Gen8. For additional information, please see the HP
SmartMemory QuickSpecs at: https://h18000.www1.hp.com/products/quickspecs/14225_na/14225_na.html
NOTE:
LRDIMM, RDIMM and UDIMMs are all distinct memory technologies and cannot be mixed
within a server. The majority of ProLiant Gen8 servers support RDIMM, UDIMM and
LRDIMM.
NOTE: A minimum of one DIMM is required per server.
NOTE:
For additional memory rules and guidelines, see the "Memory" section
later in this document.
NOTE: When HP 24GB (1x24GB) Three Rank x4 PC3L-10600R
(DDR3-1333) Registered CAS-9 Low Voltage FIO Memory Kits are used with any processors
except the E5-2690, the E5-2643, the E5-2637 v2, the E5-2643 v2, or the E5-2667
v2 all 16 DIMM slots on the BL460c Gen8 must be fully populated with these 24GB
DIMMs. When HP 24GB (1x24GB) Three Rank x4 PC3L-10600R (DDR3-1333) Registered
CAS-9 Low Voltage FIO Memory Kits are used with either the E5-2690, the E5-2643,
the E5-2637 v2, the E5-2643 v2, or the E5-2667 v2, all 12 available DIMM slots
on the BL460c Gen8 must be fully populated with these 24GB DIMMs.
|
|
HP
SmartMemory
|
|
Registered
DIMMs (RDIMMs)
|
|
Registered
DIMMs (RDIMMs) - E5-2600 v2 series Processors
|
|
HP
4GB (1x4GB) Single Rank x4 PC3L-12800R (DDR3-1600) Registered CAS-11 Low Voltage
Memory Kit
|
713981-B21
|
HP 4GB (1x4GB) Single Rank x4
PC3-14900R (DDR3-1866) Registered CAS-13 Memory Kit
|
708637-B21
|
HP 8GB (1x8GB) Single Rank x4
PC3L-12800R (DDR3-1600) Registered CAS-11 Low Voltage Memory Kit
|
731765-B21
|
HP 8GB (1x8GB) Single Rank x4
PC3-14900R (DDR3-1866) Registered CAS-13 Memory Kit
|
731761-B21
|
HP 16GB (1x16GB) Dual Rank x4
PC3L-12800R (DDR3-1600) Registered CAS-11 Low Voltage Memory Kit
|
713985-B21
|
HP 16GB (1x16GB) Dual Rank x4
PC3-14900R (DDR3-1866) Registered CAS-13 Memory Kit
|
708641-B21
|
Registered
DIMMs (RDIMMs) - E5-2600 series Processors
|
|
HP
4GB (1x4GB) Single Rank x4 PC3L-10600R (DDR3-1333) Registered CAS-9 Low Voltage
Memory Kit
|
647893-B21
|
HP 4GB (1x4GB) Single Rank x4
PC3-12800R (DDR3-1600) Registered CAS-11 Memory Kit
|
647895-B21
|
HP
8GB (1x8GB) Dual Rank x4 PC3L-10600R (DDR3-1333) Registered CAS-9 Low Voltage
Memory Kit
|
647897-B21
|
HP
8GB (1x8GB) Single Rank x4 PC3-12800R (DDR3-1600) Registered CAS-11 Memory Kit
|
647899-B21
|
HP
8GB (1x8GB) Dual Rank x4 PC3-12800R (DDR3-1600) Registered CAS-11 Memory Kit
|
690802-B21
|
HP
16GB (1x16GB) Dual Rank x4 PC3L-10600R (DDR3-1333) Registered CAS-9 Low Voltage
Memory Kit
|
647901-B21
|
HP
16GB (1x16GB) Dual Rank x4 PC3-12800R (DDR3-1600) Registered CAS-11 Memory Kit
|
672631-B21
|
Unbuffered with ECC DIMMs
(UDIMMs) - E5-2600 v2 series Processors
|
|
HP
4GB (1x4GB) Dual Rank x8 PC3L-12800E (DDR3-1600) Unbuffered CAS-11 Low Voltage
Memory Kit
|
713977-B21
|
HP
4GB (1x4GB) Dual Rank x8 PC3-14900E (DDR3-1866) Unbuffered CAS-13 Memory Kit
|
708633-B21
|
HP
8GB (1x8GB) Dual Rank x8 PC3L-12800E (DDR3-1600) Unbuffered CAS-11 Low Voltage
Memory Kit
|
713979-B21
|
HP
8GB (1x8GB) Dual Rank x8 PC3-14900E (DDR3-1866) Unbuffered CAS-13 Memory Kit
|
708635-B21
|
Unbuffered with ECC DIMMs (UDIMMs)
- E5-2600 series Processors
|
|
HP 2GB (1x2GB) Single Rank x8
PC3-12800E (DDR3-1600) Unbuffered CAS-11 Memory Kit
|
669320-B21
|
HP 2GB (1x2GB) Single Rank x8
PC3L-10600E (DDR3-1333) Unbuffered CAS-9 Low Voltage Memory Kit
|
647905-B21
|
HP 4GB (1x4GB) Dual Rank x8 PC3-12800E
(DDR3-1600) Unbuffered CAS-11 Memory Kit
|
669322-B21
|
HP 4GB (1x4GB) Dual Rank x8 PC3L-10600E
(DDR3-1333) Unbuffered CAS-9 Low Voltage Memory Kit
|
647907-B21
|
HP 8GB (1x8GB) Dual Rank x8 PC3-12800E
(DDR3-1600) Unbuffered CAS-11 Memory Kit
|
669324-B21
|
HP
8GB (1x8GB) Dual Rank x8 PC3L-10600E (DDR3-1333) Unbuffered CAS-9 Low Voltage
Memory Kit
|
647909-B21
|
Load
Reduced DIMMs (LRDIMMs) - E5-2600 v2 series Processors
|
|
HP
32GB (1x32GB) Quad Rank x4 PC3-14900L (DDR3-1866) Load Reduced CAS-13 Memory Kit
|
708643-B21
|
Load Reduced DIMMs (LRDIMMs)
- E5-2600 series Processors
|
|
HP 32GB (1x32GB) Quad Rank x4
PC3L-10600L (DDR3-1333) Load Reduced CAS-9 Low Voltage Memory Kit
|
647903-B21
|
NOTE: Depending
on the memory configuration and processor model, 1600MHz and 1333MHz memory may
operate at a lower speed. Please see the see the "Memory" section later
in this document and the Online Memory Configuration Tool for details at www.hp.com/go/ddr3memory-configurator.
|
|
|
HP
Hard Drives
|
NOTE:
The ProLiant BL460c Gen8 server includes the new HP hot-plug small form factor
(SFF) SmartDrive carrier for enhanced management and reduced maintenance errors.
HP drives from previous generation servers are not compatible with the BL460c
Gen8 drive bays.
NOTE: The mixing of standard SAS drives with SAS SSD
is supported within the server, but limits the RAID configuration to two separate
RAID 0 volumes. Mixing of other drives types is not supported.
NOTE:
HP hard drives have either a one year or three year warranty; refer to the specific
hard drive QuickSpecs for details.
NOTE: The hard drive options are
not required when configuring a drive-less model.
|
|
6G SATA Hot Plug with SmartDrive
SFF (2.5-inch) Midline (MDL) Drives
|
|
HP 1TB 6G SATA 7.2K rpm SFF (2.5-inch)
SC Midline 1yr Warranty Hard Drive
|
655710-B21
|
HP 500GB 6G SATA 7.2K rpm SFF
(2.5-inch) SC Midline 1yr Warranty Hard Drive
|
655708-B21
|
NOTE: Please
see the QuickSpecs for technical specifications and additional information at
https://h18000.www1.hp.com/products/quickspecs/13021_na/13021_na.html.
|
|
SAS Hot Plug with SmartDrive
SFF (2.5-inch) Enterprise Drives
|
|
HP
1.2TB 6G SAS 10K rpm SFF (2.5-inch) SC Enterprise 3yr Warranty Hard Drive
|
697574-B21
|
HP 900GB 6G SAS 10K rpm SFF (2.5-inch)
SC Enterprise 3yr Warranty Hard Drive
|
652589-B21
|
HP 600GB 6G SAS 10K rpm SFF (2.5-inch)
SC Enterprise 3yr Warranty Hard Drive
|
652583-B21
|
HP 450GB 6G SAS 10K rpm SFF (2.5-inch)
SC Enterprise 3yr Warranty Hard Drive
|
652572-B21
|
HP 300GB 6G SAS 10K rpm SFF (2.5-inch)
SC Enterprise 3yr Warranty Hard Drive
|
652564-B21
|
HP 300GB 6G SAS 15K rpm SFF (2.5-inch)
SC Enterprise 3yr Warranty Hard Drive
|
652611-B21
|
HP 146GB 6G SAS 15K rpm SFF (2.5-inch)
SC Enterprise 3yr Warranty Hard Drive
|
652605-B21
|
SAS Hot Plug SmartDrive SFF
(2.5-inch) Midline Drives
|
|
HP 1TB 6G SAS 7.2K rpm SFF (2.5-inch)
SC Midline 1yr Warranty Hard Drive
|
652749-B21
|
HP 500GB 6G SAS 7.2K rpm SFF
(2.5-inch) SC Midline 1yr Warranty Hard Drive
|
652745-B21
|
NOTE: Please
see QuickSpecs for technical specifications and additional information at https://h18000.www1.hp.com/products/quickspecs/12244_na/12244_na.html.
|
|
6G
SATA Value Endurance Hot Plug SFF (2.5-inch) Enterprise Boot Solid State Drives
|
|
NOTE:
These drives support Gen8 servers only.
|
|
HP
120GB 6G SATA Value Endurance SFF 2.5-in SC Enterprise Boot 3yr Wty Solid State
Drive
|
717965-B21
|
HP
80GB 6G SATA Value Endurance SFF 2.5-in SC Enterprise Boot 3yr Wty Solid State
Drive
|
734360-B21
|
6G
SATA Value Endurance Hot Plug SFF (2.5-inch) Enterprise Value Solid State Drives
|
|
NOTE:
These drives support Gen8 servers only.
|
|
HP
800GB 6G SATA Value Endurance SFF 2.5-in SC Enterprise Value 3yr Wty Solid State
Drive
|
717973-B21
|
HP
600GB 6G SATA Value Endurance SFF 2.5-in SC Enterprise Boot 3yr Wty Solid State
Drive
|
739898-B21
|
HP
480GB 6G SATA Value Endurance SFF 2.5-in SC Enterprise Value 3yr Wty Solid State
Drive
|
717971-B21
|
HP
300GB 6G SATA Value Endurance SFF 2.5-in SC Enterprise Boot 3yr Wty Solid State
Drive
|
739888-B21
|
HP
240GB 6G SATA Value Endurance SFF 2.5-in SC Enterprise Value 3yr Wty Solid State
Drive
|
717969-B21
|
6G SAS MLC Hot Plug SFF (2.5-inch)
Enterprise Mainstream Solid State Drives
|
|
HP 800GB 6G SAS Mainstream Endurance
SFF 2.5-in SC Enterprise Mainstream 3yr Wty Solid State Drive
|
690829-B21
|
HP 400GB 6G SAS Mainstream Endurance
SFF 2.5-in SC Enterprise Mainstream 3yr Wty Solid State Drive
|
690827-B21
|
HP 200GB 6G SAS Mainstream Endurance
SFF 2.5-in SC Enterprise Mainstream 3yr Wty Solid State Drive
|
690825-B21
|
6G SAS SLC Hot Plug SFF (2.5-inch)
Enterprise Performance Solid State Drives
|
|
HP 400GB 6G SAS SLC SFF (2.5-inch)
SC Enterprise Performance 3yr Warranty Solid State Drive
|
653082-B21
|
HP 200GB 6G SAS SLC SFF (2.5-inch)
SC Enterprise Performance 3yr Warranty Solid State Drive
|
653078-B21
|
3G SATA MLC Hot Plug SFF (2.5-inch)
Enterprise Mainstream Solid State Drives
|
|
HP 400GB 3G SATA MLC SFF (2.5-inch)
SC Enterprise Mainstream 3yr Warranty Solid State Drive
|
653120-B21
|
HP 200GB 3G SATA MLC
SFF (2.5-inch) SC Enterprise Mainstream 3yr Warranty Solid State Drive
|
653118-B21
|
HP 100GB 3G SATA MLC SFF (2.5-inch)
SC Enterprise Mainstream 3yr Warranty Solid State Drive
|
653112-B21
|
6G
SATA ME Hot Plug SFF (2.5-inch) Enterprise Mainstream Solid State Drives
|
|
HP
800GB 6G SATA Mainstream Endurance SFF 2.5-in SC Enterprise Mainstream 3yr Wty
Solid State Drive
|
691868-B21
|
HP
400GB 6G SATA Mainstream Endurance SFF 2.5-in SC Enterprise Mainstream 3yr Wty
Solid State Drive
|
691866-B21
|
HP
200GB 6G SATA Mainstream Endurance SFF 2.5-in SC Enterprise Mainstream 3yr Wty
Solid State Drive
|
691864-B21
|
HP
100GB 6G SATA Mainstream Endurance SFF 2.5-in SC Enterprise Mainstream 3yr Wty
Solid State Drive
|
691862-B21
|
NOTE: The mixing
of standard SAS drives with SAS SSD is supported within the server, but limits
the RAID configuration to two separate RAID 0 volumes. Mixing of other drives
types is not supported
|
|
NOTE:
Please see the QuickSpecs for technical specifications and information at
https://h18000.www1.hp.com/products/quickspecs/14038_na/14038_na.html.
|
|
Additional Options
HP
Insight software
|
HP Insight Control
|
|
HP
Insight Control including 1yr 24x7 Technical Support and Updates Single Server
License
|
C6N27A
|
HP
Insight Control including 1yr 24x7 Technical Support and Updates Electronic License
|
C6N28ABE
|
HP
Insight Control including 1yr 24x7 Support ProLiant ML/DL/BL-bundle FIO Electronic
License
|
C6N36ABE
|
HP
Insight Control Server Provisioning Media Kit
|
BD883A
|
HP
Insight Management Media Kit
|
C6N31A
|
NOTE:
HP Insight Management Media Kit contains DVDs without licenses. Contains HP Systems
Insight Manager, HP Insight Control, HP Matrix Operating Environment, and Virtual
Connect Enterprise Manager software. Uses an integrated installer to perform quick
and accurate software installation and updates.
|
|
NOTE: Electronic
and Flexible-Quantity licenses can be used to purchase multiple licenses with
a single activation key.
|
|
NOTE: Customer
will receive a license entitlement certificate, which must be redeemed online
or via fax in order to obtain the license activation key(s). Includes one year
of 24 x 7 HP Software Technical Support Service.
|
|
NOTE: Licenses
ship without media. The HP Insight Management Media Kit can be ordered separately,
or can be downloaded at https://www.hp.com/go/insightupdates
|
|
NOTE: For additional
license kits, please see the QuickSpecs at: https://h18004.www1.hp.com/products/quickspecs/12631_na/12631_na.html
|
|
HP Insight Control server
deployment
|
|
HP Insight Control Server Deployment
including 1yr 24x7 Support Electronic License
|
T9082AAE
|
HP Insight Control Server Deployment
including 1yr 24x7 Support Single Server License
|
452151-B21
|
NOTE: Licenses
ship without media. The HP Insight Management Media Kit can be ordered separately,
or can be downloaded at https://www.hp.com/go/insightupdates.
|
|
NOTE: Customer
will receive a license entitlement certificate, which must be redeemed online
or via fax in order to obtain the license activation key(s). Includes one year
of 24 x 7 HP Software Technical Support Service.
NOTE: For additional
license kits, please see the QuickSpecs at: https://h18004.www1.hp.com/products/quickspecs/12631_na/12631_na.html
|
|
|
HP
iLO Advanced License
|
HP Integrated
Lights-Out (iLO) Advanced for ProLiant BladeSystem Remote Management
|
|
HP
iLO Advanced Blade including 3yr 24x7 Tech Support and Updates Electronic License
|
E6U63ABE
|
HP
iLO Advanced Blade 1 Server License with 3yr 24x7 Tech Support and Updates
|
BD502A
|
HP
iLO Advanced for BladeSystem including 1yr 24x7 Tech Support and Updates Electronic
License
|
E6U60ABE
|
HP iLO Advanced for BladeSystem
including 1yr 24x7 Support Single Server License
|
512488-B21
|
HP
Integrated Lights-Out (iLO)
|
|
HP
iLO Scale Out
|
|
HP
Integrated Lights-Out Scale-Out 3yr 24x7 Tech Support and Updates Flex Quantity
License
|
BD776A
|
HP
Integrated Lights-Out Scale-Out 1yr 24x7 Tech Support and Updates Flex Quantity
License
|
BD778A
|
HP
Integrated Lights-Out Scale-Out including 3yr 24x7 Tech Support and Updates Flex
Qty E-LTU
|
BD776AAE
|
HP
Integrated Lights-Out Scale-Out including 1yr 24x7 Tech Support and Updates Flex
Qty E-LTU
|
BD778AAE
|
HP
Integrated Lights-Out Scale-Out including 3yr 24x7 Tech Support and Updates Tracking
License
|
BD777A
|
HP
Integrated Lights-Out Scale-Out including 1yr 24x7 Tech Support and Updates Tracking
License
|
BD779A
|
NOTE:
Customer will receive a license entitlement certificate, which must be redeemed
online or via fax in order to obtain the license activation key(s). Includes one
or three years of 24 x 7 HP Software Technical Support Service.
NOTE:
For additional license kits, including electronic delivery options, please see
the iLO QuickSpecs at https://www.hp.com/go/iLO
|
|
NOTE: Customer
will receive a license entitlement certificate, which must be redeemed online
or via fax in order to obtain the license activation key(s). Includes one or three
year of 24 x 7 HP Software Technical Support Service.
NOTE: For additional
license kits, please see the QuickSpecs at:
https://h18004.www1.hp.com/products/quickspecs/14276_na/14276_na.html
|
|
|
High
Performance Clusters
|
HP Cluster
Management Utility
|
|
HP Insight Cluster Management
Utility 1yr 24x7 Flexible License
|
QL803B
|
HP
Insight Cluster Management Utility 3yr 24x7 Flexible License
NOTE:
These part numbers can be used to purchase one certificate for multiple licenses
and support with a single activation key. Each license is for one node (server).
Customer will receive a printed end user license agreement and license entitlement
certificate via physical shipment. The license entitlement certificate must be
redeemed online in order to obtain a license key. Customer also will receive a
support agreement.
|
BD476A
|
HP
Insight Cluster Management Utility Media
NOTE:
For additional license kits please see the QuickSpecs at https://h18004.www1.hp.com/products/quickspecs/12612_na/12612_na.html.
|
BD477A
|
|
HP
I/O Accelerator Options
|
HP 1.2TB
Multi Level Cell IO Accelerator for BladeSystem c-Class
|
QK763A
|
HP
785GB Multi Level Cell IO Accelerator for BladeSystem c-Class
|
QK762A
|
HP
365GB Multi Level Cell IO Accelerator for BladeSystem c-Class
|
QK761A
|
|
HP Security
|
HP Trusted Platform Module Option
|
488069-B21
|
NOTE: The TPM
(Trusted Platform Module) is a microcontroller chip that can securely store
artifacts used to authenticate the server platform. These artifacts can
include passwords, certificates and encryption keys. Windows® BitLocker™
Drive Encryption (BitLocker) is a data protection feature available in Windows
Server® 2008. BitLocker leverages the enhanced security capabilities
of a Trusted Platform Module (TPM) version 1.2. The TPM works with BitLocker
to help protect user data and to ensure that a server running Windows Server
2008 has not been tampered with while the system was offline.
NOTE: For more information about TPM, including a white paper, go
to https://www.hp.com/go/TPM.
NOTE: ProLiant OS pre-installed units will come with the partition
required for TPM deployment.
NOTE: The TPM key is unique to every TPM deployed server and must
be retained. Misplacing or losing the key could result in data loss.
|
|
|
HP
InfiniBand Mezzanines
|
NOTE:
When an InfiniBand adapter is installed in mezzanine slot 1, only one port is
active (regardless of operating mode). When installed in any other mezzanine slot,
both ports are active.
|
|
NOTE: InfiniBand
QDR and FDR speeds are only supported on the HP BladeSystem c7000 Enclosure. For
additional information, please see the HP BladeSystem c7000 Enclosure and InfiniBand
QuickSpecs at: https://h18004.www1.hp.com/products/quickspecs/12586_na/12586_na.html
https://h18000.www1.hp.com/products/quickspecs/13078_na/13078_na.html
|
|
HP Infiniband QDR/Ethernet 10Gb
2-port 544M Adapter
|
644160-B21
|
NOTE:
The QDR InfiniBand adapter may be installed in any mezzanine slot of the server.
|
|
HP
Infiniband FDR/Ethernet 10Gb/40Gb 2-port 544M Adapter
|
644161-B22
|
NOTE: The FDR
InfiniBand adapter must be installed in mezzanine slot 1 for FDR mode and may
be installed in any mezzanine slot if operated in any other mode.
|
|
|
HP
Storage Blades
|
HP
D2220sb PCIe and StoreVirtual VSA Bundle with SAAP License
|
QW914A
|
HP
D2220sb PCIe w/(12) 900 GB 6G SAS HDD Bundle with SAAP License
|
QW915A
|
HP
D2220sb Build-to-order Storage Blade
|
QW917A
|
NOTE:
For additional information, please see the QuickSpecs for technical specifications
and additional information at: https://h18000.www1.hp.com/products/quickspecs/14507_na/14507_na.html
|
|
|
HP
Flash Media Kits for USB Drives
|
HP
Flash Media Kits for USB Drives
|
|
HP 2GB USB Flash Media Drive
Key Kit
NOTE: HP qualified blank USB
key for use with HP ProLiant servers that support the VMware virtualization environment.
HP recommends this industry standard USB flash device for use with VMware ESXi.
USB device must be installed in the internal slot of the ProLiant server for use
with VMware ESXi. Refer to HP VMware Getting Started Guide for installation instructions.
|
608447-B21
|
HP
Enterprise Performance Flash Media Kits for Memory Cards
|
|
HP 4GB microSD Enterprise Performance
Flash Media Kit
NOTE: The USB flash
media and Secure Digital cards are for integrated hypervisor virtualization environments
needing a low cost boot solution with the highest performance and reliability.
Learn more at https://h18004.www1.hp.com/products/servers/options/flash_drives.html.
|
647444-B21
|
HP
Enterprise Mainstream Flash Media Kits for Memory Cards
|
|
HP
8GB microSD Enterprise Mainstream Flash Media Kit
|
726116-B21
|
HP
32GB microSD Enterprise Mainstream Flash Media Kit
|
700139-B21
|
NOTE:
Please see the QuickSpecs for Technical Specifications and additional information:
https://h18000.www1.hp.com/products/quickspecs/13971_na/13971_na.html
|
|
|
HP
Care Pack Services
|
Proactive
Care - Collaborative Support plus Proactive services delivered by the on shore/near
shore Advanced Solution Center (ASC) and backed by the global delivery organization,
end-to-end case ownership from a Technical Solution Specialists and Technical
Account Manager who remotely delivers firmware/software revision management, proactive
scans and incident trend reports. Recommended for customers running a virtualized
infrastructure and/or customers who desire an enhanced call support experience.
|
|
HP 3 year 4 hour 24x7 ProLiant
BL4xxc Proactive Care Service
|
U3B14E
|
HP 3 year 4 hour 24x7 with Defective
Media Retention ProLiant BL4xxc Proactive Care Service
|
U3B17E
|
HP 3 year 6 hour Call To Repair
24x7 ProLiant BL4xxc Proactive Care Service
|
U3B20E
|
HP 3 year 6hr Call To Repair
24x7 with Defective Media Retention ProLiant BL4xxc Proactive Care SVC
|
U3B23E
|
Proactive Care Personalized Support
Environmental Option - to add an onsite Account Support Manager (ASM) to Proactive
Care. ASM is an assigned resource who delivers support planning and brings technical
expertise and best practices advice for the customer's environment.
|
|
HP 3 year ISS ProactiveCare
Personalized Support
|
U6W98E
|
Installation Services
- reduce the time required to get your system up and running and help minimize
disruptions to your business.
|
|
HP Install c-Class Server Blade
Service
|
UE493E
|
HP Hardware Installation during
Non Standard Hours c-Class Enclosure and Server Blade Service
|
UG869E
|
Additional HP Care Pack services
can be found at: https://www.hp.com/go/cpc
|
|
Memory
For
detailed memory configuration rules and guidelines, please use the Online DDR3
Memory Configuration Tool:
www.hp.com/go/ddr3memory-configurator
Memory
Subsystem Architecture
Each Intel® Xeon® E5-2600 family or Intel®
Xeon® E5-2600 family processor socket contains four memory channels that support
two DIMMs each for a total of eight (8) DIMM per installed processor or a grand
total of sixteen (16) DIMMs for the server. Up to 32GB capacity DIMMs are supported
for 512GB of memory (16 DIMM slots x 32GB per DIMM).
Memory Population
Rules and Guidelines:
- A minimum of one DIMM is required per processor.
- Install DIMMs only if the corresponding
processor is installed.
- If only one processor is installed in a two
processor system, only half of the DIMM slots are available.
- DIMM sizes can be mixed in channel. To maximize
performance, it is recommended to balance the total memory capacity
between all installed processors and to load the channels similarly
whenever possible.
- RDIMMs operating at either 1.35V or 1.5V may be
mixed in any order, but the system will power them at the higher
voltage.
- LRDIMM, RDIMM and UDIMMs are all distinct memory
technologies and cannot be mixed within a server. The majority of
ProLiant Gen8 servers support RDIMM, UDIMM and LRDIMM.
- The Intel Xeon E5-2620 processor does not
support DIMMs at 1.35V.
- DIMMs of different speeds may be mixed in any
order; the server will select a common optimal speed.
- The maximum memory speed is a function of the
memory type, memory configuration, and processor model.
- The maximum memory capacity is a function of the
memory type and number of installed processors.
- HP memory from previous generation servers is
not compatible with the BL460c Gen8 Server Blade.
- To realize the performance memory capabilities listed in
this document, HP SmartMemory is required. For additional information, please
see the HP SmartMemory QuickSpecs at: https://h18000.www1.hp.com/products/quickspecs/14225_na/14225_na.html.
- For
memory population rules and additional memory guidelines, please see the BL460c
Gen8 user guide at https://www.hp.com/support.
|
BL460c Gen8 Supported Memory Bandwidth
on Intel® Xeon® E5-2600 series Processors
|
DIMM Type
|
Registered
DIMMS (RDIMMs)
|
Load Reduced
(LRDIMMs)
|
Unbuffered
with ECC DIMMs (UDIMMs)
|
DIMM Rank
|
Single
Rank (1R)
|
Dual
Rank (2R)
|
Three Rank
(3R)
|
Quad
Rank
(4R)
|
Single
Rank
(1R)
|
Dual
Rank
(2R)
|
DIMM Capacity
|
4GB
|
4GB
|
8GB
|
8GB
|
8GB
|
16GB
|
16GB
|
24GB
|
32GB
|
2GB
|
2GB
|
4GB
|
4GB
|
8GB
|
8GB
|
DIMM Native Speed (MHz)
|
1333
|
1600
|
1600
|
1333
|
1600
|
1333
|
1600
|
1333
|
1333
|
1333
|
1600
|
1333
|
1600
|
1600
|
1333
|
Voltage
*
|
LV
|
Std
|
Std
|
LV
|
Std
|
LV
|
Std
|
LV
|
LV
|
LV
|
Std
|
LV
|
Std
|
Std
|
LV
|
NOTE:
*LV= low voltage at 1.35V; Std = standard voltage at 1.5V.
|
|
SLOTS THAT CAN BE POPULATED
|
16 slot servers
|
16
|
16
|
16
|
16
|
16
|
16
|
16
|
16
|
16
|
16
|
16
|
16
|
16
|
16
|
16
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
MAXIMUM CAPACITY
(GB)
*
|
16 slot servers
|
64
|
64
|
128
|
128
|
128
|
256
|
256
|
384
|
512
|
32
|
32
|
64
|
64
|
128
|
128
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
POPULATED DIMM
SPEED (MHz)
|
1
DIMM Per Channel (1DPC)
|
1333
|
1600
|
1600
|
1333
|
1600
|
1333
|
1600
|
n/a
|
1333
**
|
1333
|
1600
|
1333
|
1600
|
1600
|
1333
|
2 DIMM Per Channel (2DPC)
|
1333
|
1600
|
1600
|
1333
|
1600
|
1333
|
1600
|
1333
**
**
|
1333
**
|
1333
***
|
1600
|
1333
***
|
1600
|
1600
|
1333
***
|
*
Maximum capacity will vary based on individual server platform qualification schedule
**LRDIMM
enables 3 DIMMs per channel. HP SmartMemory will supports up to 3DPC@DDR3-1066
at 1.35V. Third party memory may only support 3DPC @DDR3-1066 at 1.5V.
***Using
HP SmartMemory, UDIMMs at 2DPC are supported up to 1333MHz. Third party UDIMMs
at 2DPC may only support up to 1066MHz.
**** Only supported on BL460c Gen8
|
NOTE:
Maximum memory speed is a function of the processor QPI bus speed; see the table
below "Memory Speed by Processor Model".
|
NOTE: When HP 24GB
(1x24GB) Three Rank x4 PC3L-10600R (DDR3-1333) Registered CAS-9 Low Voltage FIO
Memory Kits are used with any processors except the E5-2690, the E5-2643, the
E5-2637 v2, the E5-2643 v2, or the E5-2667 v2 all 16 DIMM slots on the BL460c
Gen8 must be fully populated with these 24GB DIMMs. When HP 24GB (1x24GB) Three
Rank x4 PC3L-10600R (DDR3-1333) Registered CAS-9 Low Voltage FIO Memory Kits are
used with either the E5-2690, the E5-2643, the E5-2637 v2, or the E5-2643 v2,
or the E5-2667 v2, all 12 available DIMM slots on the BL460c Gen8 must be fully
populated with these 24GB DIMMs.
|
NOTE:
The internal USB 2.0 Port is not available when the HP 24GB (1x24GB) Three Rank
x4 PC3L-10600R (DDR3-1333) Registered CAS-9 Low Voltage FIO Memory Kits (700404-B21)
are used.
|
|
|
Intel Gen8 Supported Memory Bandwidth
on E5-2600v2 series Processor
|
DIMM Type
|
Register
DIMM
|
Load Reduced (LRDIMMs)
|
Unbuffered
DIMM
|
DIMM Rank
|
Single
Rank (1R)
|
Dual Rank (2R)
|
Dual
Rank (2R)
|
Single Rank (1R)
|
Single Rank (1R)
|
Dual
Rank (2R)
|
Dual Rank (2R)
|
Three
Rank (3R)
|
Quad
Rank
(4R)
|
Dual
Rank (2R)
|
DIMM Capacity
->
|
4GB
|
4GB
|
8GB
|
8GB
|
8GB
|
8GB
|
16GB
|
16GB
|
24GB
|
32GB
|
4GB
|
4GB
|
8GB
|
8GB
|
DIMM Native Speed (MT/s) -
>
|
1600
|
1866
|
1600
|
1866
|
1600
|
1866
|
1600
|
1866
|
1333
|
1866
|
1600
|
1866
|
1600
|
1866
|
Voltage
|
LV
|
Std
|
LV
|
Std
|
LV
|
Std
|
LV
|
Std
|
LV
|
Std
|
LV
|
Std
|
LV
|
Std
|
|
SLOTS THAT CAN BE POPULATED
|
16 slot servers
|
16
|
16
|
16
|
16
|
16
|
16
|
16
|
16
|
16
|
16
|
16
|
16
|
16
|
16
|
64
slot servers#
|
64
|
64
|
64
|
64
|
64
|
64
|
64
|
64
|
64
|
64
|
n/a
|
n/a
|
n/a
|
n/a
|
MAXIMUM CAPACITY
(GB)
*
|
16 slot servers
|
64
|
64
|
128
|
128
|
128
|
128
|
256
|
256
|
384
|
512
|
64
|
64
|
128
|
128
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
POPULATED DIMM
SPEED (MT/s)
|
1 DIMM
Per Channel
|
1600
|
1866
|
1600
|
1866
|
1600
|
1866
|
1600
|
1866
|
n/a
|
1866
|
1600
|
1866
|
1600
|
1866
|
2 DIMM Per Channel
|
1600
|
1866
|
1600
|
1866
|
1600
|
1866
|
1600
|
1866
|
1333
****
|
1866
|
1600
|
1866
|
1600
|
1866
|
Memory
speed is a function of the processor QPI bus speed.
* Maximum capacity will
vary based on individual server platform qualification schedule
****For HP
SmartMemory, UDIMM is supported at 2DPC@DDR3-1333. Third party memory may only
support
up to 2DPC@DDR3-1066. Only supported on BL460c Gen8.
# All configurations
on 64 slot server run at DDR3-1066.
## RBSU setting required
### with IVB
processor
|
|
|
Memory Speed by E5-2600 Series Processor Model
|
Processor
Models
|
Supported
Memory Speeds
|
E5-2680,
E5-2670, E5-2667, E5-2665, E5-2660, E5-2650, E5-2650L, E5-2637
|
1600/1333/1066MHz
|
E5-2640,
E5-2630, E5-2630L, E5-2620
|
1333/1066MHz
|
E5-2609,
E5-2603
|
1066MHz
|
|
|
Memory
Speed by E5-2600 v2 Series Processor Model
|
Processor Models
|
Supported Memory Speeds
|
E5-2697
v2, E5-2695 v2, E5-2690 v2, E5-2680 v2, E5-2670 v2, E5-2667 v2, E5-2660 v2, E5-2650
v2, E5-2643 v2, E5-2637 v2
|
1866/1600MHz
|
E5-2640
v2, E5-2630 v2, E5-2620 v2, E5-2650L v2, E5-2630L v2
|
1600MHz
|
E5-2609
v2, E5-2603 v2
|
1333MHz
|
|
|
Standard
and Maximum Memory Capacity (Pre-configured Models) for E5-2600 Series
|
Pre Configured Models
|
Standard
Memory
|
Maximum Memory Plus
Optional Memory
|
Standard
Memory Replaced with Optional Memory
|
Intel
Xeon E5-2670, E5-2660
|
64GB
(8x 8GB)
|
192GB
(8x 8GB
+ 8x 16GB)
|
512GB
(16x 32GB)
|
Intel
Xeon E5-2650, E5-2650L
|
32GB
(4x 8GB)
|
224GB
(4x 8GB
+ 12x 16GB)
|
512GB
(16x 32GB)
|
Intel
Xeon E5-2620, E5-2609
|
16GB
(4x 4GB)
|
208GB
(4x
4GB + 12x 16GB)
|
512GB
(16x 32GB)
|
|
|
Standard and Maximum Memory Capacity
(Pre-configured Models) for E5-2600 v2 Series
|
Pre Configured Models
|
Standard
Memory
|
Maximum Memory Plus
Optional Memory
|
Standard
Memory Replaced with Optional Memory
|
Intel
Xeon E5-2670 v2, E5-2660 v2
|
64GB
(4x
16B)
|
256GB
(4x 16GB +
12x 16GB)
|
512GB
(16x
32GB)
|
Intel
Xeon E5-2650 v2, E5-2650L v2, E5-2640 v2
|
32GB
(2x
16GB)
|
256GB
(2x 16GB +
14x 16GB)
|
512GB
(16x
32GB)
|
Intel
Xeon E5-2620 v2, E5-2609 v2
|
16GB
(2x
8GB)
|
240GB
(2x 8GB + 14x
16GB)
|
512GB
(16x
32GB)
|
|
|
NOTE: Capacity
references are rounded to the common gigabyte (GB) values.
- 2GB
= 2,048MB
- 4GB = 4,096MB
- 8GB = 8,192MB
- 16GB
= 16,384MB
- 32GB = 32,768MB
|
Memory options part number decoder
|
|
|
Following
are memory options available from HP:
|
HP
Memory
|
NOTE: The
HP ProLiant BL460c Gen8 10Gb FlexibleLOM Configure-to-order Blade Server (641016-B21)
cannot be configured the new 1866MHz HP Smart Memory or the new 1600MHz Low Voltage
(1.35v) HP Smart Memory.
NOTE: HP memory from previous generation servers
are not qualified or warranted with this HP ProLiant BL460c Gen8 Server. HP SmartMemory
is required to realize the memory performance improvements and enhanced functionality
listed in this document for Gen8. For additional information, please see the HP
SmartMemory QuickSpecs at: https://h18000.www1.hp.com/products/quickspecs/14225_na/14225_na.html
NOTE:
LRDIMM, RDIMM and UDIMMs are all distinct memory technologies and cannot be mixed
within a server. The majority of ProLiant Gen8 servers support RDIMM, UDIMM and
LRDIMM.
|
|
HP SmartMemory
|
|
Registered DIMMs
(RDIMMs)
|
|
Registered DIMMs (RDIMMs) -
E5-2600 v2 series Processors
|
|
HP
4GB (1x4GB) Single Rank x4 PC3L-12800R (DDR3-1600) Registered CAS-11 Low Voltage
Memory Kit
|
713981-B21
|
HP
4GB (1x4GB) Single Rank x4 PC3-14900R (DDR3-1866) Registered CAS-13 Memory Kit
|
708637-B21
|
HP
8GB (1x8GB) Single Rank x4 PC3L-12800R (DDR3-1600) Registered CAS-11 Low Voltage
Memory Kit
|
731765-B21
|
HP
8GB (1x8GB) Single Rank x4 PC3-14900R (DDR3-1866) Registered CAS-13 Memory Kit
|
731761-B21
|
HP
16GB (1x16GB) Dual Rank x4 PC3L-12800R (DDR3-1600) Registered CAS-11 Low Voltage
Memory Kit
|
713985-B21
|
HP
16GB (1x16GB) Dual Rank x4 PC3-14900R (DDR3-1866) Registered CAS-13 Memory Kit
|
708641-B21
|
Registered
DIMMs (RDIMMs) - E5-2600 series Processors
|
|
HP
4GB (1x4GB) Single Rank x4 PC3L-10600R (DDR3-1333) Registered CAS-9 Low Voltage
Memory Kit
|
647893-B21
|
HP
4GB (1x4GB) Single Rank x4 PC3-12800R (DDR3-1600) Registered CAS-11 Memory Kit
|
647895-B21
|
HP
8GB (1x8GB) Dual Rank x4 PC3L-10600R (DDR3-1333) Registered CAS-9 Low Voltage
Memory Kit
|
647897-B21
|
HP
8GB (1x8GB) Single Rank x4 PC3-12800R (DDR3-1600) Registered CAS-11 Memory Kit
|
647899-B21
|
HP
8GB (1x8GB) Dual Rank x4 PC3-12800R (DDR3-1600) Registered CAS-11 Memory Kit
|
690802-B21
|
HP
16GB (1x16GB) Dual Rank x4 PC3L-10600R (DDR3-1333) Registered CAS-9 Low Voltage
Memory Kit
|
647901-B21
|
HP
16GB (1x16GB) Dual Rank x4 PC3-12800R (DDR3-1600) Registered CAS-11 Memory Kit
|
672631-B21
|
Unbuffered
with ECC DIMMs (UDIMMs) - E5-2600 v2 series Processors
|
|
HP 4GB (1x4GB) Dual Rank x8 PC3L-12800E
(DDR3-1600) Unbuffered CAS-11 Low Voltage Memory Kit
|
713977-B21
|
HP 4GB (1x4GB) Dual Rank x8 PC3-14900E
(DDR3-1866) Unbuffered CAS-13 Memory Kit
|
708633-B21
|
HP 8GB (1x8GB) Dual Rank x8 PC3L-12800E
(DDR3-1600) Unbuffered CAS-11 Low Voltage Memory Kit
|
713979-B21
|
HP 8GB (1x8GB) Dual Rank x8 PC3-14900E
(DDR3-1866) Unbuffered CAS-13 Memory Kit
|
708635-B21
|
Unbuffered with ECC DIMMs (UDIMMs)
- E5-2600 series Processors
|
|
HP 2GB (1x2GB) Single Rank x8
PC3-12800E (DDR3-1600) Unbuffered CAS-11 Memory Kit
|
669320-B21
|
HP
2GB (1x2GB) Single Rank x8 PC3L-10600E (DDR3-1333) Unbuffered CAS-9 Low Voltage
Memory Kit
|
647905-B21
|
HP
4GB (1x4GB) Dual Rank x8 PC3-12800E (DDR3-1600) Unbuffered CAS-11 Memory Kit
|
669322-B21
|
HP
4GB (1x4GB) Dual Rank x8 PC3L-10600E (DDR3-1333) Unbuffered CAS-9 Low Voltage
Memory Kit
|
647907-B21
|
HP
8GB (1x8GB) Dual Rank x8 PC3-12800E (DDR3-1600) Unbuffered CAS-11 Memory Kit
|
669324-B21
|
HP
8GB (1x8GB) Dual Rank x8 PC3L-10600E (DDR3-1333) Unbuffered CAS-9 Low Voltage
Memory Kit
|
647909-B21
|
Load
Reduced DIMMs (LRDIMMs) - E5-2600 v2 series Processors
|
|
HP 32GB (1x32GB) Quad Rank x4
PC3-14900L (DDR3-1866) Load Reduced CAS-13 Memory Kit
|
708643-B21
|
Load Reduced DIMMs (LRDIMMs)
- E5-2600 series Processors
|
|
HP 32GB (1x32GB) Quad Rank x4
PC3L-10600L (DDR3-1333) Load Reduced CAS-9 Low Voltage Memory Kit
|
647903-B21
|
NOTE: Depending
on the memory configuration and processor model, 1600MHz and 1333MHz memory may
operate at a lower speed. Please see the see the "Memory" section later
in this document and the Online Memory Configuration Tool for details at www.hp.com/go/ddr3memory-configurator.
|
|
Storage
|
1-2
|
2
x SFF hot-plug SAS, SATA, SAS SDD, and SATA SSD hard drives
|
System Unit
|
Dimensions (H x W x D)
(with bezel)
|
7.11 x 2.18 x 20.37
in (18.07 x 5.54 x 51.76 cm)
|
Weight
(approximate)
|
Maximum: all processors, 16 DIMMs,
hard drives, mezzanine cards, and two flash cache batteries installed)
|
14.00 lb (6.33 kg)
|
Minimum: one processor and 2 DIMMs
installed
|
10.50 lb (4.75 kg)
|
Power Specifications
|
For power specifications including input requirements, BTU rating, and
power supply output, please see the:
To review typical system power ratings use the HP Power Advisor which
is available via the online tool located at www.hp.com/go/hppoweradvisor.
|
System Inlet Temperature
|
Operating
|
10° to 35°C (50° to 95°F) at sea level with an altitude
derating of 1.0°C per every 305 m (1.8°F per every 1,000 ft) above
sea level to a maximum of 3,050 m (10,000 ft), no direct sustained sunlight.
Maximum rate of change is 10°C/hr (18°F/hr). The upper limit
may be limited by the type and number of options installed.
System performance may be reduced if operating with a fan fault or above
30°C (86°F).
|
Non-operating
|
-30° to 60°C (-22°
to 140°F). Maximum rate of change is 20°C/hr (36°F/hr).
|
Relative Humidity
(non-condensing)
|
Operating
|
10 to 90% relative humidity (Rh),
28°C (82.4°F) maximum wet bulb temperature, non-condensing.
|
Non-operating
|
5 to 95% relative humidity (Rh),
38.7°C (101.7°F) maximum wet bulb temperature, non-condensing.
|
Altitude
|
Operating
|
3,050 m (10,000 ft). This value
may be limited by the type and number of options installed. Maximum allowable
altitude change rate is 457 m/min (1,500 ft/min).
|
Non-operating
|
9,144 m (30,000 ft). Maximum allowable
altitude change rate is 457 m/min (1,500 ft/min).
|
Acoustic Noise
|
For acoustic noise specifications, please see the HP BladeSystem c-Class
Enclosures QuickSpecs located at:
HP BladeSystem c3000 Enclosure QuickSpecs:
https://h18000.www1.hp.com/products/quickspecs/12790_div/
12790_div.html
HP BladeSystem c7000 Enclosure QuickSpecs:
https://h18000.www1.hp.com/products/quickspecs/12810_div/
12810_div.html
|
|
HP Smart Array P220i
Controller
|
Disk Drive Interface
|
6Gb/s SAS (Serial Attached SCSI)
|
Server Interface
|
x4 PCI Express host interface
|
Cache Memory
|
512MB flash backed write cache
(FBWC) cache standard
|
Logical Drives Supported
|
64 (with included 512MB cache)
|
Host Memory Addressing
|
64-bit, supporting servers memory
space greater than 4GB
|
RAID Support
|
RAID 1 (mirroring) and RAID 0
(striping)
|
Other
|
Upgradeable firmware with recovery
ROM
Online drive flash (with SAS drives)
|
|
HP FlexFabric 10Gb
2-port 554FLB FlexibleLOM
|
Type
|
Integrated dual-port KR 10Gb FlexibleLOM
with FlexFabric (Flex-10, FCoE, hardware-based iSCSI, iSCSI boot, TCP/IP
offload engine, and autosencing 1Gb/10Gb Ethernet capability)
|
Network Processor
|
Emulex BE3
|
Data Transfer Method
|
x8 PCI Express 2.0
|
Network Transfer Rate
|
Two ports, each at 20Gbps full
duplex; 40Gbps aggregate full duplex theoretical bandwidth
NOTE: Each port is autosensing 1Gb/10Gb,
and can interoperate with 1Gb or 10Gb HP BladeSystem c-Class interconnect
components. Both ports will operate at the same speed.
NOTE: Each port on the 554FLB adapter transmits from the server at
20Gbps (theoretical) full duplex.
|
IEEE Compliance
|
802.1p, 802.1q, 802.1qau, 802.3ad,
802.3ae, 802.3ap (10GBase-KX4) and 802.3x
|
Standard Features
|
ProLiant Teaming including Network
Fault Tolerance, Transmit Load Balancing, and Switch-Assisted Load Balancing
9K Jumbo frames (4K Jumbo frames when in FCoE mode)
Microsoft Windows Receive Side Scaling (RSS)
Hardware-based accelerated iSCSI
iSCSI boot
Flex-10 capability
Fibre Channel over Ethernet (FCoE)
TCP/IP offload engine (stateless TCP/IP)
Autosencing 1Gb/10Gb Ethernet
|
|
Environment-friendly Products and
Approach
|
End-of-life Management and Recycling
|
Hewlett-Packard offers end-of-life HP product return, trade-in, and recycling
programs in many geographic areas. For trade-in information, please go
to: https://www.hp.com/go/green.
To recycle your product, please go to: https://www.hp.com/go/green
or contact your nearest HP sales office. Products returned to HP will
be recycled, recovered or disposed of in a responsible manner.
The EU WEEE directive (2002/95/EC) requires manufacturers to provide treatment
information for each product type for use by treatment facilities. This
information (product disassembly instructions) is posted on the Hewlett
Packard web site at: https://www.hp.com/go/green.
These instructions may be used by recyclers and other WEEE treatment facilities
as well as HP OEM customers who integrate and re-sell HP equipment.
|
|
|