DL QuickSpecs
|
DL20
|
|
DL60
|
|
DL80
|
|
DL120
|
|
DL140
|
|
DL145
|
|
DL160
|
|
DL160se
|
|
DL165
|
|
DL180
|
|
DL185
|
|
DL320
|
|
DL325
|
|
DL345
|
|
DL360
|
|
DL365
|
|
DL380
|
|
DL385
|
|
DL388
|
|
DL560
|
|
DL580
|
|
DL585
|
|
DL740
|
|
DL760
|
|
DL785
|
|
DL1000
|
|
|
ML QuickSpecs
|
ML30
|
|
ML110
|
|
ML115
|
|
ML150
|
|
ML310
|
|
ML330
|
|
ML350
|
|
ML370
|
|
ML530
|
|
ML570
|
|
ML750
|
|
|
BL QuickSpecs
|
BL10e
|
|
BL20p
|
|
BL25p
|
|
BL260c
|
|
BL280c
|
|
BL2x220c
|
|
BL30p
|
|
BL35p
|
|
BL40p
|
|
BL420c
|
|
BL45p
|
|
BL460c
|
|
BL465c
|
|
BL480c
|
|
BL495c
|
|
BL60p
|
|
BL620c
|
|
BL660c
|
|
BL680c
|
|
BL685c
|
|
BL860c
|
|
|
SL QuickSpecs
|
SL160z
|
|
SL165z
|
|
SL170s
|
|
SL170z
|
|
SL230s
|
|
SL250s
|
|
SL270s
|
|
SL2x170z
|
|
SL335s
|
|
SL390s
|
|
SL4540
|
|
SL4545
|
|
|
XL QuickSpecs
|
XL170r
|
|
XL190r
|
|
XL220a
|
|
XL230a
|
|
XL730f
|
|
XL740f
|
|
XL750f
|
|
|
CL QuickSpecs
|
CL1850
|
CL1850 G1
| |
CL380
|
CL380 G1
| |
|
|
|
|
|
|
|
Proliant ML310 G1 QuickSpecs |
US QuickSpecs |
|
|
|
|
|
|
|
|
|
Proliant ML310 G1 Overview
1.
48X CD-ROM | 4. Two 1" Non
Hot Plug Drive | 2. Removable
media bays |
5. Four 64-bit/33MHz PCI slots |
3. 1.44 MB Diskette Drive |
6. System Fan |
At A Glance
- Supports 1 Intel Pentium 4,
2.8 GHz or 2.53 GHz processor with 512-KB second level ECC cache standard
- ServerWorks GC-SL Chipset with 533MHz FSB (2.8GHz
& 2.53GHz models)
- 256-MB of PC2100 DDR SDRAM running at 266MHz, with
Advanced ECC capabilities standard, expandable to 4 GB
- Four total slots available: four 64-bit/33MHz PCI
- NC7760 PCI Gigabit Server Adapter (Integrated/Embedded)
- Integrated Dual Channel Ultra ATA/100 Adapter with
Integrated ATA RAID 0, 1, & 1+0 (ATA Models) or Integrated Single
Channel Wide Ultra3 SCSI Adapter (SCSI Models)
- Support for up to five 1" Ultra3 or Ultra320
Non Hot Plug SCSI hard drives or four 1" ATA NHP Drives (depending
on model)
- Internal SCSI storage capacity of up to 818.4 GB
(2 x 300 GB hot plug 1" Ultra320 SCSI hard drives in optional 2x1
hot plug cage + 3 x 72.8 GB non-hot plug Ultra320 SCSI HD)
- Usable Internal ATA storage capacity of up to 520
GB (4 x 160 GB 1" ATA/100 drives)
- NOTE: The ProLiant ML310 supports
a maximum of 130 GB capacity per ATA drive. When 160-GB ATA hard drives
(PN
366486-B21) are connected to the internal ATA RAID controller, the
ProLiant ML310 recognizes a capacity of 130-GB.
- Integrated ATI Rage XL with 8MB SDRAM video
- 300W Power Supply
- Two USB ports
- ROM Based Setup Utility (RBSU) and PXE support
- Insight Manager, SmartStart and Automatic Server
Recovery-2 (ASR-2)
- Protected by HP Services, including a one-year, limited
warranty, Next Business Day 1 year on-site limited Global warranty and
Pre-Failure Warranty, which covers processors, memory, and hard drives
- Certain restrictions and exclusions apply. Consult the Customer Support
Center at 1-800-345-1518 for details.
|
Standard Features
Processor
One of the following depending on Model: |
Intel Pentium 4
processor 2.80 GHz |
Intel Pentium 4
processor 2.53 GHz |
|
Cache
Memory
|
Integrated 512-KB
Level 2 ECC cache |
|
Memory
|
Standard |
256MB (PC2100 DDR SDRAM running
at 266MHz, with Advanced ECC) |
Maximum |
4 GB |
|
Network Controller |
NC7760 PCI Gigabit Server Adapter
(Integrated) |
|
Expansion
Slots | I/O (4 Total, 4 Available) | PCI
Voltage: | |
64-bit/33MHz PCI |
3.3 volts |
|
Storage Controllers |
Integrated Single
Channel Wide Ultra3 SCSI Adapter (SCSI Models)
OR |
|
Integrated Dual
Channel Ultra ATA-100 IDE Adapter with Integrated ATA RAID 0, 1, & 1+
0 (ATA Models) |
|
Storage |
Diskette Drive |
1.44 MB Diskette Drive |
Optical Drive |
48x IDE (ATAPI) CD-ROM Drive |
Hard Drives |
One of the following: |
(1) 36.4 GB Wide Ultra3 SCSI
10,000 rpm 1" Drive (2.8GHz & 2.53GHz
SCSI Models only) |
(1) 40 GB ATA/100 7750 rpm
1" Drive (Select ATA Models)
(1) 80 GB ATA/100 7750 rpm 1" Drive (Select ATA Models) |
Maximum Internal Storage
(SCSI Models) |
818.4 GB Internal Maximum SCSI
capacity (2 x 300 GB in optional 2x1 hot plug drive cage + 3 x 72.8 GB) |
Maximum Internal Storage
(ATA Models) |
520 GB (4 x 160.0 GB) (internal
drive bays and removable media bays)
NOTE: The ProLiant ML310 supports
a maximum of 130 GB capacity per ATA drive. When 160-GB ATA hard drives
(PN 366486-B21) are connected to the internal ATA RAID controller, the ProLiant
ML310 recognizes a capacity of 130-GB. |
|
Graphics |
Integrated ATI RAGE XL Video
Controller with 8MB SDRAM Video Memory |
|
Form Factor |
Tower (5U) (Tower to Rack Enabling
Option Kit (PN 238547-B22) available) |
|
ProLiant Essentials
Foundation Pack Software |
HP Systems Insight Manager
|
HP's new HP Systems Insight
Manager (HP SIM) helps maximize system uptime and performance and
reduce system maintenance costs by providing proactive notification
of problems before those problems result in unplanned downtime or
reduced productivity. HP SIM are both easy to set up work with the
Insight Management Agents, integrated Light-Out and Remote Insight
Light-Outs Edition, and Version Control Agents to deliver robust fault,
configuration, and asset management as well as remote administration.
With HP SIM customers will also be able to take advantage of role-based
security; the ability to manage ProLiant, Integrity, and HP 9000 systems;
and plug-ins for storage, client, printer, and power management as
well as server rapid deployment, performance management, and workload
management. For more details on HP SIM visit https://www.hp.com/go/hpsim. |
|
Management Agents |
The Management Agents
form the foundation for HP's Intelligent Manageability strategy. They
provide direct, browser-based access to in-depth instrumentation built
into HP servers, workstations, desktops, and portables, and send alerts
to Insight Manager 7 and other enterprise management applications
in case of subsystem or environmental failures. For additional information
about the Management Agents and other management products from HP,
please visit the management Web site at https://www.hp.com/servers/manage. |
|
SmartStart | SmartStart
is a tool that simplifies server setup, providing a rapid way to deploy reliable
and consistent server configurations. For more information, please visit the SmartStart
Web site at https://www.hp.com/servers/manage.
SmartStart version supported (minimum):
SmartStart 6.40. |
|
Subscriber's Choice |
Subscriber's Choice Driver
and Support Alerts/Notifications is a web-based email subscription
service that provides automatic delivery of software and driver change
notifications for ProLiant products. Sign up at https://www.hp.com/go/subscriberschoice
and customize your profile to receive various new alerts as they become
available, on a weekly or monthly basis. |
|
ROMPaq, support software, and
configuration utilities |
The latest software, drivers,
and firmware fully optimized and tested for your ProLiant server and
options available in SmartStart or downloadable from Software and
Drivers download pages, linked from the SmartStart website at https://www.hp.com/servers/smartstart. |
|
Survey
Utility and diagnostics utilities |
The most advanced configuration
analysis, reporting and troubleshooting utilities used by HP and at
your fingertips, available in SmartStart. |
|
Optional ProLiant Essentials
Value Packs |
Optional software offerings
that selectively extend the functionality of an Adaptive Infrastructure
to address specific business problems and needs:
- Rapid Deployment Pack an automated solution for multi-server
deployment and provisioning, enabling companies to quickly and
easily adapt to changing business demands.
- Workload Management Pack provides easier management of
complex environments, improving overall server utilization and
enabling Microsoft® Windows® 2000 customers for the first
time to confidently deploy multiple applications on a single multiprocessor
ProLiant Server.
- Performance Management Pack a performance management
solution that identifies and explains hardware performance bottlenecks
on ProLiant servers and attached options enabling users to better
utilize their valuable resources..
NOTE:
Flexible and volume quantity license kits are available for ProLiant Essentials
Value Packs. Refer to https://www.hp.com/servers/proliantessentials
or the various ProLiant Essentials Value Pack product QuickSpecs for more information. |
| NOTE:
For more information regarding ProLiant Essentials Software, please see the
following URL: https://www.hp.com/servers/proliantessentials. |
|
Industry Standard Compliance |
ACPI V1.0b Compliant
PCI 2.2 Compliant
PXE Support
WOL Support
Microsoft Logo certifications
Novell Logo certifications |
|
Manageability |
Insight Manager 7
HP Systems Insight Manager
Redundant ROM
Online ROM Flash Utility
Automatic Server Recovery-2 (ASR-2)
Drive Parameter Tracking (with Smart Array Controller)
Dynamic Sector Repairing (with Smart Array Controller)
Pre-Failure Warranty (covers processors, memory and hard drives
BIOS Serial Console |
|
Security |
Power-on password
Setup password
Diskette boot control
Power switch security
Intruder Alert Message |
|
Server Power Cords |
All models ship with one 12'
standard low-line country specific power cord. |
|
Power Supply |
300 Watts, PFC (Power Factor
Correcting) |
|
System Fans |
1 - Non-hot plug, Non-redundant
system fan shipped standard (NOTE:
Does not include fans in CPU heatsink or power supply) |
|
Rack
Airflow Requirements |
Rack 10000 series Cabinets
The increasing power of new high-performance processor technology requires
increased cooling efficiency for rack-mounted servers. The 10000 Series
Racks provide enhanced airflow for maximum cooling, allowing these racks
to be fully loaded with servers using the latest processors.
CAUTION: If a third-party rack
is used, observe the following additional requirements to ensure adequate
airflow and to prevent damage to the equipment:
- Front and rear doors: If your 42U
server rack includes closing front and rear doors, you must allow
830 square inches (5,350 sq cm) of hole evenly distributed from top
to bottom to permit adequate airflow (equivalent to the required 64
percent open area for ventilation).
- Side: The clearance between the
installed rack component and the side panels of the rack must be a
minimum of 2.75 inches (7 cm).
CAUTION: Always use blanking panels
to fill all remaining empty front panel U-spaces in the rack. This arrangement
ensures proper airflow. Using a rack without blanking panels results in
improper cooling that can lead to thermal damage.
|
|
NOTE: For additional information, refer to the Setup and Installation
Guide or the Documentation CD provided with the server, or to the server documentation
located in the Support section at the following URL: https://h18000.www1.hp.com/products/servers/ProLiantdl760/index.html. |
|
HP Factory Express Capabilities |
HP Factory Express gives you
the flexibility to choose from a full menu of factory capabilities all in
one manufacturing facility, in one process, with one touch giving you full
control and access to HP's World class manufacturing facility anytime. This
approach provides you the speed to deploy your IT needs, with total quality
assurance, reliability, and predictability to lower your total cost of ownership
by letting HP install, rack, and customize your software and hardware options
for you. |
|
Service
and Support |
One-year limited warranty, including
hardware diagnostic support, pre-failure warranty (coverage of hard drives,
memory and processors). The warranty is fully supported by HP Services and
a worldwide network of resellers and service providers. In addition 90-day's
getting started software telephone support may be covered under the warranty
or available for an additional fee. Enhancements to warranty services are
available through HP Care Pack services.
NOTE: Limited warranty includes 1
year parts, 1 year labor, 1-year on-site support
Care Pack services provide a range of life cycle support options that
let you choose the service levels that meet your business requirements,
from basic to mission-critical.
A full range of HP Care Pack hardware and software services are available
including:
- Installation and start up
- Education courses
- Extended onsite hardware coverage hours from same business day 13
hours, 5 day to 24 hours, 7 days call window with options including
4-hour response or 6-hour Call To Repair
- Comprehensive range of software technical support for Microsoft,
Linux, ProLiant Essentials and VMWare-based IT solutions helping to
deliver high level of application availability. Response times range
from 30 mins for critical problems to 2 hours.
- System Management, Performance Services and Mission Critical Support
Solution
HP Care Pack Services include HP branded hardware options qualified for
the server, purchased at the same time or afterwards, internal to the
enclosure, as well as 22" and smaller external monitors and tower
UPS options up to 3KVA. 22" and smaller external monitors will be
covered at the same service level and coverage period as the server. For
servers or storage systems installed within a rack, service also covers
all HP qualified rack options installed within the same rack.
|
|
NOTE: For more information on HP Care
Pack services, contact any of our worldwide sales offices or resellers
or visit our worldwide Web site on the internet at: https://www.hp.com/hps/carepack
NOTE: For more complete information
on HP Services offerings, customers and resellers, please visit us at:
https://www.hp.com/hps
NOTE: Additional information regarding
worldwide limited warranty and technical support is available at: https://h18004.www1.hp.com/products/servers/platforms/warranty/index.html
|
Models
ML310T01 P2800-512KB
256MB, 40GB, ATA
289918-xx2 |
Processor(s) |
(1) Intel Pentium 4 2.80 GHz
(standard) |
Cache Memory |
Integrated 512-KB Level 2 cache |
Memory |
256 MB (Standard) to 4 GB (Maximum)
of Advanced ECC PC2100 DDR SDRAM DIMM Memory |
Network Controller |
NC7760 PCI Gigabit Server Adapter
(Integrated/Embedded) |
Storage Controller |
Integrated Dual Channel Ultra
ATA-100 IDE Adapter with Integrated ATA RAID 0,1, & 1+0 |
Hard Drives |
40 GB Ultra ATA/100 |
Internal Storage |
520 GB maximum (with optional
hard drives) |
Optical Drive |
48x IDE (ATAPI) CD-ROM Drive |
Diskette Drive |
1.44 MB Diskette Drive |
Form Factor |
Tower (5U) (Tower to Rack Enabling
Option Kit available) |
|
ML310T01 P2533-512KB
256MB, 40GB, ATA
306669-xx2 |
Processor(s) |
(1) Intel Pentium 4 2.53 GHz
(standard) |
Cache Memory |
Integrated 512-KB Level 2 cache |
Memory |
256 MB (Standard) to 4 GB (Maximum)
of Advanced ECC PC2100 DDR SDRAM DIMM Memory |
Network Controller |
NC7760 PCI Gigabit Server Adapter
(Integrated/Embedded) |
Storage Controller |
Integrated Dual Channel Ultra
ATA-100 IDE Adapter with Integrated ATA RAID 0,1, & 1+0 |
Hard Drives |
40 GB Ultra ATA/100 |
Internal Storage |
520 GB maximum (with optional
hard drives) |
Optical Drive |
48x IDE (ATAPI) CD-ROM Drive |
Diskette Drive |
1.44 MB Diskette Drive |
Form Factor |
Tower (5U) (Tower to Rack Enabling
Option Kit available) |
|
ML310T01 P2800-512KB
256MB, 36GB, SCSI
289917-xx2 |
Processor(s) |
(1) Intel Pentium 4 2.80 GHz
(standard) |
Cache Memory |
Integrated 512-KB Level 2 cache |
Memory |
256 MB (Standard) to 4 GB (Maximum)
of Advanced ECC PC2100 DDR SDRAM DIMM Memory |
Network Controller |
NC7760 PCI Gigabit Server Adapter
(Integrated/Embedded) |
Storage Controller |
Integrated Single Channel Ultra3
SCSI Adapter |
Hard Drives |
(1) 36.4 GB Ultra320 SCSI 10,000
rpm |
Internal Storage |
818.4 GB maximum (with optional
2x1 hot plug hard drive cage and optional hard drives) |
Optical Drive |
48x IDE (ATAPI) CD-ROM Drive |
Diskette Drive |
1.44 MB Diskette Drive |
Form Factor |
Tower (5U) (Tower to Rack Enabling
Option Kit available) |
|
ML310T01 P2530-512KB
256MB, 36GB, SCSI
306667-xx2 |
Processor(s) |
(1) Intel Pentium 4 2.53 GHz
(standard) |
Cache Memory |
Integrated 512-KB Level 2 cache |
Memory |
256 MB (Standard) to 4 GB (Maximum)
of Advanced ECC PC2100 DDR SDRAM DIMM Memory |
Network Controller |
NC7760 PCI Gigabit Server Adapter
(Integrated/Embedded) |
Storage Controller |
Integrated Single Channel Ultra3
SCSI Adapter |
Hard Drives |
(1) 36.4 GB Ultra320 SCSI 10,000
rpm |
Internal Storage |
818.4 GB maximum (with optional
2x1 hot plug hard drive cage and optional hard drives) |
Optical Drive |
48x IDE (ATAPI) CD-ROM Drive |
Diskette Drive |
1.44 MB Diskette Drive |
Form Factor |
Tower (5U) (Tower to Rack Enabling
Option Kit available) |
|
Country Code Key |
XX=00 |
NA |
|
XX=01 |
Australia |
|
XX=03 |
UK |
|
XX=04 |
Germany |
|
XX=34 |
Austria |
|
XX=05 |
France |
|
XX=29 |
Japan |
|
XX=37 |
AP |
|
XX=42 |
Euro |
|
XX=AA |
PRC |
Options
ProLiant Essentials Value Pack Software | Rapid
Deployment Pack, 1 User, V1.x NOTE:
This license allows 1 server to be managed and deployed via the Deployment Server. |
267196-B21 | Rapid
Deployment Pack, 1 User, V1.x (Japan) NOTE:
This license allows 1 server to be managed and deployed via the Deployment
Server. | 267196-291 |
Rapid Deployment
Pack, 10 Users, V1.x NOTE:
This license allows 10 servers to be managed and deployed via the Deployment Server. |
269817-B21 | Rapid
Deployment Pack, 10 Users, V1.x (Japan) NOTE:
This license allows 10 servers to be managed and deployed via the Deployment Server. |
269817-291 | ProLiant
Essentials Workload Management Pack 2.0 (Featuring Compaq Resource Partitioning
Manager version 2.0) |
|
ProLiant Essentials
Performance Management Pack Single Server License
NOTE: This license allows 1 server
to be managed by Performance Management Pack. |
306696-B21 |
ProLiant Essentials
Performance Management Pack Flexible License
NOTE: A single pack is shipped with
a single license key for the total number of licenses ordered |
306697-B21 | ProLiant
Essentials Performance Management Pack Tracking license |
306698-B21 | NOTE:
Flexible and volume quantity license kits are available for ProLiant Essentials
Value Packs. Refer to https://www.hp.com/servers/proliantessentials
or the various ProLiant Essentials Value Pack product QuickSpecs for more information.
NOTE: For more information regarding ProLiant Essentials Software, please
see the following URL:
https://www.hp.com/servers/proliantessentials. |
|
|
NetServer to ProLiant
integrations services |
HP NetServer to ProLiant
integration and assessment service
|
304164-002
|
NOTE:
HP identifies current levels of NetServer support, services, and management.
This service helps maximize customer’s ability to add ProLiant platforms
into their current environment. |
|
HP TopTools to Insight
Manager 7 installation and startup service
|
304163-002
|
NOTE: Provides on-site
review, installation and configuration services for Insight Manager 7. HP
will also re-create, as closely as possible, the views and reports from
the customer’s current TopTools configuration. This service assures a smooth
transition to the ProLiant Essentials software. |
|
HP NetServer to ProLiant
Essentials Rapid Deployment Pack installation and startup service |
304162-002
|
NOTE: Install and configure
Rapid Deployment Pack in a test environment, then deploy a server image
to a maximum of 250 systems in the production environment. This service
helps to assure successful system deployment. |
|
|
Memory
(SDRAM DIMMs)
|
1024MB of Advanced ECC PC2100
DDR SDRAM DIMM Memory Kit (1 x 1024 MB) |
|
512MB of Advanced ECC PC2100 DDR
SDRAM DIMM Memory Kit (1 x 512 MB) |
|
256MB of Advanced ECC PC2100
DDR SDRAM DIMM Memory Kit (1 x 256 MB) |
|
128MB of Advanced ECC PC2100
DDR SDRAM DIMM Memory Kit (1 x 128 MB) |
|
|
Optical Drives |
16X DVD-ROM Drive Option Kit (Carbon)
|
217053-B21 |
|
CD-RW/DVD-ROM Combo Drive Option
Kit
NOTE: The DVD-ROM drive is supported
in the CD-ROM bay and in the removable media bay. If placed in the removable
media bay, it requires the 2-Device IDE cable (PN 305381-B21). |
|
|
Internal Storage
|
ML3xx Two Bay Hot Plug SCSI Drive
Cage
NOTE: This Drive Cage has one 1"drive
bay and one 1.6"drive bay. |
|
|
ML310 G1 Hard Drives |
Ultra320 Universal
Non-Hot Plug |
|
NOTE: All U320
Universal Hard Drives are backward compatible to U2 or U3 speeds. U320 drives
require an optional U320 Smart Array Controller or U320 SCSI HBA to support
U320 transfer rates. |
|
36.4 GB U320 10,000 rpm Non-Hot
Plug Hard Drive, (1") |
|
36.4 GB U320 15,000 rpm Non-Hot
Plug Hard Drive, (1")
|
|
72.8 GB U320 10,000 rpm Non-Hot
Plug Hard Drive, (1") |
|
Ultra320 Universal
Hot Plug |
|
300-GB 10,000 rpm U320 Universal
Hard Drive (1") |
|
146.8-GB 10,000 rpm U320 Universal
Hard Drive (1") |
|
72.8-GB 10,000 rpm U320 Universal
Hard Drive (1") |
|
72.8-GB 15,000 rpm U320 Universal
Hard Drive (1") |
|
36.4-GB 15,000 rpm U320 Universal
Hard Drive (1") |
|
ATA 100 Non-Hot Plug
(ATA Models only) |
|
160-GB ATA/100 7,200 rpm Drive
(1")
NOTE: The ProLiant ML310 supports
a maximum of 130 GB capacity per ATA drive. When 160-GB ATA hard drives
(PN 366486-B21) are connected to the internal ATA RAID controller, the ProLiant
ML310 recognizes a capacity of 130-GB.
|
|
80-GB ATA/100 7,200 rpm Drive
(1") |
|
40-GB ATA/100 7,200 rpm Drive
(1") |
|
NOTE: Please see
the Hard Drive QuickSpecs for Technical Specifications such as capacity,
height, width, interface, transfer rate, seek time, physical configuration,
and operating temperature:
U320 Hard Drive QS:
https://h18000.www1.hp.com/products/quickspecs/11531_div/11531_div.html
(Worldwide)
https://h18000.www1.hp.com/products/quickspecs/11531_na/11531_na.html
(North America)
ATA100 Hard Drive QS:
https://h18000.www1.hp.com/products/quickspecs/11361_div/11361_div.html
(Worldwide)
https://h18000.www1.hp.com/products/quickspecs/11361_na/11361_na.html
(North America) |
|
|
Storage Controllers
SCSI Drives |
NOTE:
The following Storage Controllers are qualified for SCSI drives only.
They do not support ATA Drives.
|
|
Smart Array 5304/256 Controller
|
|
Smart Array 5304/256 Controller (Japan)
|
283551-291
|
Smart Array 641 Controller
|
|
Smart Array 642 Controller
|
|
64 MB Battery Backed Write Cache
Enabler
NOTE: This 64 MB BBWC supports the
Smart Array 641 Controller and Smart Array 642 Controller.
|
|
128MB Battery-Backed Cache Enabler
NOTE: This 128MB BBWC supports the
Smart Array 641 Controller and Smart Array 642 Controller. |
|
64-Bit/133MHz Dual Channel Ultra320
SCSI Adapter |
|
64-Bit/66-MHz Dual Channel Wide Ultra3 SCSI Adapter,
Alternate OS
|
|
NOTE: Please see
the following Controller or SCSI Adapter QuickSpecs for Technical Specifications
such as PCI Bus, PCI Peak Data Transfer Rate, SCSI Protocols supported,
SCSI Peak Data Transfer Rate, Channels, SCSI Ports, Drives supported, Cache,
RAID support, and additional information:
https://h18000.www1.hp.com/products/quickspecs/10640_div/10640_div.html
(Smart Array 5300 Series)
https://h18000.www1.hp.com/products/quickspecs/12067_div/12067_div.html
(Smart Array 641)
https://h18000.www1.hp.com/products/quickspecs/12069_div/12069_div.html
(Smart Array 642)
https://h18000.www1.hp.com/products/quickspecs/10429_div/10429_div.html
(SCSI Adapter) |
|
|
Communications
|
HP NC1020 Cu Gigabit Server Adapter 32 PCI Single Port
|
|
NC6136 Gigabit Server Adapter,
64-bit/66MHz, PCI, 1000 SX |
|
HP NC6770 PCI-X Gigabit Server
Adapter, 1000-SX |
|
NC7170 Dual Port PCI-X 1000T Gigabit
Server Adapter |
|
NOTE:
Any NC61XX, NC71XX or NC77XX NIC can be used for redundancy with the
embedded NC7760 Network Controller. |
|
Country Code Key |
XX = 00 |
US |
XX = 15 |
Greece |
XX = 01 |
Austria |
XX = 16 |
S. America |
XX = 03 |
UK |
XX = 17 |
ARAB |
XX = 04 |
Germany |
XX = 18 |
Belgium |
XX = 05 |
France |
XX = 24 |
Poland |
XX = 06 |
Italy |
XX = 28 |
Thailand |
XX = 07 |
Spain |
XX = 29 |
Japan |
XX = 08 |
Denmark |
XX = 33 |
Netherlands |
XX = 09 |
Norway |
XX = 35 |
Finland |
XX = 10 |
Sweden/Finland |
XX = 37 |
APD |
XX = 11 |
Switzerland |
XX = AB |
Taiwan |
XX = 12 |
French Canadian |
XX = AD |
Korea |
XX = 13 |
Portugal |
XX = BB |
HE |
XX = 14 |
Turkey |
XX = C9 |
LA MERCO |
|
Management Options
|
Remote Insight Lights-Out Edition II (NA, LA)
|
227251-001
|
Remote Insight Lights-Out Edition II (EMEA)
|
227251-021
|
Remote Insight Lights-Out Edition II (ROW)
|
227251-371
|
|
Security |
HP/Atalla AXL600L SSL Accelerator Card for ProLiant Servers |
524545-B21
|
Compaq AXL300 Accelerator
PCI Card (HW SSL Encryption) for ProLiant Servers |
227933-B21
|
|
Tape Drives
|
NOTE: In
order to install certain tape drives internally, you may need to remove
the rails that come standard on the drives and then re-insert the
screws in the mounting holes. Mounting screws are shipped standard
with server. |
|
NOTE: To
run external SCSI-based devices, either an Internal-to-External SCSI
Cable Option kit (for SCSI models) or a SCSI controller with external
channel (for ATA models) must be purchased.
Review the server cabling matrix for additional information on cables
required to connect backup products to the server.
|
|
External, and Rack-Mount
Ultrium Tape Drives |
|
HP StorageWorks Ultrium
215 Tape Drive, External (Carbon) |
|
HP StorageWorks Ultrium
215 rack-mount (Carbon) - Single drive installed in a 3U rack-mount
kit |
|
HP StorageWorks Ultrium
215 Array Module (Carbon) - Offline hot-swap drive for Tape Array
5300 |
|
HP StorageWorks Ultrium
230 Tape Drive, External (Carbon) |
|
HP StorageWorks Ultrium
230, Rack-mount (Carbon) - Single drive installed in a 3U rack-mount
kit |
|
HP StorageWorks Ultrium
230 Array Module (Carbon) - Offline hot-swap drive for Tape Array
5300 |
|
HP StorageWorks Ultrium
460 Tape Drive, External (Carbon) |
|
HP StorageWorks Ultrium
460, Rack-mount (Carbon) - Single drive installed in a 3U rack-mount
kit |
|
HP StorageWorks Ultrium
460 Array Module (Carbon) - Offline hot-swap drive for Tape Array
5300 |
|
NOTE: Please
see the HP StorageWorks Ultrium 215, 230, and 460 Tape Drive QuickSpecs
for additional options such as controllers, media, and other related
items:
https://h18006.www1.hp.com/products/quickspecs/11739_div/11739_div.html
(Worldwide)
https://h18006.www1.hp.com/products/quickspecs/11739_na/11739_na.html
(North America) |
|
For
an up-to-date listing of the latest O/S and software support details
for HP Ultrium tape drives, please visit: https://www.hp.com/go/connect |
|
Internal, External,
Hot-Plug, and Rack-Mount DAT Drives
|
|
NOTE:
Use of a hot plug tape drives requires installation of the optional
two-bay SCSI drive cage.
|
|
HP StorageWorks DAT 72 Tape
Drive, External (Carbon) |
|
HP StorageWorks DAT 72 Tape
Drive, Internal (Carbon) |
|
HP StorageWorks DAT 72 Tape
Drive, Internal Hot-Plug (Carbon) |
|
HP StorageWorks DAT 72 Array
Module (Carbon) - Offline hot-swap drive for Tape Array 5300 |
|
HP StorageWorks DAT 40 Tape
Drive, External (Carbon) |
|
HP StorageWorks DAT 40 Tape
Drive, Internal (Carbon) |
|
HP StorageWorks DAT 40 Tape
Drive, Internal Hot-Plug (Carbon) |
|
HP StorageWorks DAT 40 Array
Module (Carbon) - Offline hot-swap drive for Tape Array 5300 |
|
HP StorageWorks DAT 24e
Tape Drive, External (Flint) |
|
HP StorageWorks DAT 24 Tape
Drive, Internal (Flint) |
|
HP StorageWorks DAT 24 Array
Module (Carbon) - Offline hot-swap drive for Tape Array 5300 |
|
NOTE:
Please see the DAT Tape Drive QuickSpecs for controllers, media,
and other options:
https://h18000.www1.hp.com/products/quickspecs/11883_div/11883_div.html
(Worldwide)
https://h18000.www1.hp.com/products/quickspecs/11883_na/11883_na.html
(North America)
For an up-to-date listing of the latest O/S and software support details
for HP DAT drives, please visit: https://www.hp.com/go/connect
|
|
Internal and External
DLT VS Tape Drives
|
|
HP StorageWorks DLT VS80
Tape Drive, Internal (Carbon) WW |
|
HP StorageWorks DLT VS80
Tape Drive, External (Carbon) NA |
|
HP StorageWorks DLT VS80
Tape Drive, External (Carbon) Int'l |
337699-B31
|
HP StorageWorks DLT VS80
Tape Drive, External (Carbon) Japan
|
337699-291
|
NOTE: Please
see the DLT VS80 Tape Drive QuickSpecs for additional options such
as host bus adapters, controllers, media, and other options:
https://h18006.www1.hp.com/products/quickspecs/11403_div/11403_div.html
(Worldwide)
https://h18006.www1.hp.com/products/quickspecs/11403_na/11403_na.html
(North America)
For an up-to-date listing of the latest O/S and software support details
for the DLT VS80, please visit: https://www.hp.com/go/connect
|
|
External SDLT Tape
Drives |
|
HP StorageWorks SDLT 320
Tape Drive, External (Carbon) NA |
|
HP StorageWorks SDLT 320
Tape Drive, External (Carbon) Int'l |
257319-B31
|
HP StorageWorks SDLT 320
Tape Drive, External (Carbon) Japan |
257319-291
|
NOTE: Please
see the SDLT 320 Tape Drive QuickSpecs for additional options such
as adapters, controllers, and media.
https://h18006.www1.hp.com/products/quickspecs/11840_div/11840_div.html
(Worldwide)
https://h18006.www1.hp.com/products/quickspecs/11840_na/11840_na.html
(North America)
For an up-to-date listing of the latest O/S and software support details
for HP SDLT tape drives, please visit: https://www.hp.com/go/connect |
|
Rack-Mount Tape Drive
Enclosures
|
|
HP StorageWorks 3U Rack-Mount
Kit |
|
NOTE: The
3U Rack-Mount Kit can support up to 2 full-height or 4 half-height
tape drives and compatible with multiple Single-Ended and LVD SCSI
tape drives including DAT, DLT VS80, SDLT 320, Ultrium 215, Ultrium
230, and Ultrium 460 Tape Drives. |
|
HP StorageWorks 5U Rack-Mount
Kit |
274339-B21
|
NOTE: The
5U Rack-Mount Kit can support up to 4 full-height tape drives and
is compatible with SDLT 320, Ultrium 230, and Ultrium 460 tape drives. |
|
NOTE: Please
see the Rack-Mount Tape Drive Kits QuickSpecs for additional information
regarding these kits:
https://h18000.www1.hp.com/products/quickspecs/10854_div/10854_div.html
(Worldwide)
https://h18000.www1.hp.com/products/quickspecs/10854_na/10854_na.html
(North America)
|
|
HP StorageWorks Tape Array
5300 |
|
NOTE:
The Tape Array 5300 is a 3U enclosure that supports up to 2 full-height
or 4 half-height hot-swap array modules, including DAT and Ultrium
tape drives. Cables and terminators are not included and must be ordered
separately.
NOTE: Please see the Tape Array 5300 QuickSpecs for additional
information regarding this product.
https://h18000.www1.hp.com/products/quickspecs/11878_div/11878_div.html
(Worldwide)
https://h18000.www1.hp.com/products/quickspecs/11878_na/11878_na.html
(North America)
|
|
Accessories for 3U
& 5U Rack-mount Tape Drive Kits
|
|
LVD Cable Kit, VHDCI/HD68
NOTE: For use with the 3U Rack-mount
Kit and 5U Rack-mount Kit only. |
|
LVD Cable Kit, HD68/HD68
NOTE: For use with the 3U Rack-mount
Kit and 5U Rack-mount Kit only.
|
|
Accessories for 3U
& 5U Rack-mount Tape Drive Kits
|
|
PSU/Fan
Upgrade Kit - Redundant hot-swap power supply unit and fan for Tape
Array 5300.
|
|
68-pin HD multi-mode terminator |
|
1.0m 68-pin VHDCI to 68-pin
HD cable |
|
2.5m 68-pin VHDCI to 68-pin
HD cable |
|
5.0m 68-pin VHDCI to 68-pin
HD cable |
|
10.0m 68-pin VHDCI to 68-pin
HD cable |
|
0.5m 68-pin HDI to 68-pin
HD cable LVD/SE |
|
1.5m 68-pin HDI to 68-pin
HD cable LVD/SE |
C2979B
|
0.9m 68-pin HDI to 68-pin
HD cable LVD/SE |
C2911C
|
2.5m 68-pin HDI to 68-pin
HD cable LVD/SE |
C2924C
|
NOTE: For
use with Tape Array 5300 only |
|
|
|
Tape Autoloaders
|
DAT Autoloader
|
|
|
HP StorageWorks DAT 40x6 Tape
Autoloader, External (Flint)
|
C5717C |
|
NOTE: Please see
the DAT 40x6 Tape Autoloader QuickSpecs at https://www.hp.com/go/tape
for additional options such as host bus adapters, controllers and media.
|
|
|
External Storage
Tower & Rack |
NOTE: To run
any external SCSI-based devices, the customer must purchase an Internal
to External Cable Option kit or an additional SCSI controller for SCSI models.
For ATA models, a SCSI controller must be purchased. |
|
HP StorageWorks Modular Smart Array 30 SB
NOTE: Rack-mountable 14 drive enclosure
with single bus, redundant power supplies.
|
302969-B21
|
HP StorageWorks Modular Smart
Array 30 DB
NOTE: Rack-mountable 14 drive enclosure
with dual bus, redundant power supplies. |
302970-B21
|
NOTE: The Modular
Smart Array Enclosure 30 Family supports the Wide Ultra3, Ultra320 1"
Hot Plug Hard Drives. |
|
Redundant Power Supply 499W |
338296-B21 |
|
StorageWorks Enclosure 4200 Redundant
Power Supply Option
|
338296-B21 |
|
StorageWorks Enclosure 4200 Ultra3
Single Bus I/O Module Option |
190212-B21 |
|
StorageWorks Enclosure 4200 Ultra3
Dual Bus I/O Module Option
|
190213-B21 |
|
StorageWorks Single Bus U320 I/O
Module |
287484-B21
|
|
StorageWorks Dual Bus U320 I/O
Module |
287483-B21
|
|
Uninterruptible Power Systems – Tower Supply
|
HP T500 UPS 120 V (US)
|
361475-001
|
HP Pro UPS 500 (300 Watt) 120V
(NA) |
136386-001
|
HP Pro UPS 500 (300 Watt) 120V
(Int'l) |
136386-B31
|
HP UPS Model T700 (700VA, 500
Watt), Low Voltage (NA) |
204015-001
|
HP UPS Model T700 (700VA, 500
Watt), High Voltage (Int'l) |
204015-B31
|
HP UPS Model T700 (700VA, 500
Watt), Low Voltage (Japan) |
204015-291
|
HP UPS Model T1000 XR (1000VA,
700 Watt), Low Voltage) (NA) |
204155-001
|
HP UPS Model T1000 XR (1000VA,
700 Watt), High Voltage) (Int'l) |
204155-B31
|
HP UPS T1000 XR (1000VA, 700Watts)
100 VAC (JPN) |
312803-291
|
HP UPS Model T1500 XR (1440VA,
1050 Watt), Low Voltage) (NA) |
|
HP UPS Model T1500 XR (1440VA,
1050 Watt), Low Voltage) (Int'l) |
204155-B32
|
HP UPS Model T1500 XR (1500VA,
1050 Watt), Low Voltage (JPN) |
204155-291
|
|
Uninterruptible Power Systems Rack
|
HP UPS R5500 XR, (5000VA, 4500
Watt), High Voltage (NA/Jpn) |
326529-D71 |
HP UPS R5500 XR, (6000VA, 5400
Watt), High Voltage (Int'l) |
326529-B31 |
HP UPS R1500 XR (100 to 127) (NA) |
|
HP UPS R1500 XR (208 to 480) (Int'l) |
204404-B31
|
HP UPS R1500 XR (100 to 127) (Japan) |
204404-291
|
HP UPS R3000 XR (120V) (NA) |
|
HP UPS R3000 XR (208V) (NA) |
|
HP UPS R3000 XR (100V) (Japan) |
192186-291
|
HP UPS R3000 XR (208V) (Japan)
Compaq UPS R3000 XR (200V) (Japan) |
192186-292
|
HP UPS R3000 XR (230V) (Int'l
- detachable cord) |
192186-B31
|
HP UPS R3000 XR (230V) (16A IEC309
Plug) |
192186-B32
|
HP UPS R3000 XR (230V) (16A CEE
7/7 SCHUKO Plug) |
192186-B33
|
HP UPS R3000 XR (230V) (16A BS-546
Plug) |
192186-AR1
|
Rack-Mountable UPS R6000 (208V)
(NA) |
|
Rack-Mountable UPS R6000 (230V)
(Int'l) |
347757-B31
|
Rack-Mountable UPS R6000 (200V)
(Japan) |
347757-291
|
UPS R12000 XR N+ x (200-240V)
(WW-hardwired) |
207552-B22
|
NOTE: UPS R6000
has a hardwired input; and the UPS R12000 XR has a hardwired input and output
connection. |
|
|
Modular PDUs 1U/0U
(Up to 32 outlets)
NOTE:
1U/0U mounting brackets shipped with
the unit (optimized for 10000 and 9000 series racks).
|
HP Modular Power Distribution Units (mPDU),
Low Volt Model, 24A (100-127 VAC) (NA, Japan
|
252663-D71 |
NOTE:
This mPDU ( 252663-D71) may also be used to connect the low volt model of
the UPS R3000 XR. |
|
HP Modular Power Distribution Units (mPDU),
High Volt Model, 24A (200-240 VAC) (NA, Japan)
|
252663-D72 |
HP Modular Power Distribution Units (mPDU),
High Volt Model, 32A (200-240 VAC) (Int’l)
|
252663-B31 |
HP Modular Power Distribution Units (mPDU),
High Volt Model, 40A (200-240 VAC) (WW)
|
252663-B21 |
NOTE:
This mPDU ( 252663-B21), 40A model has a hardwired input. |
|
HP Modular Power Distribution Units (mPDU),
High Volt Model, 16A (200-240 VAC) (WW)
|
252663-B24 |
NOTE:
This PDU has a detachable input power cord and allows for adaptability to
country specific power requirements. This model may also be used with the
high volt UPSs R3000 XR and R6000 For North America, need to order cable
PN 340653-001. |
|
NOTE:Please see
the following Modular Power Distribution Unit (Zero-U/1U Modular PDUs) QuickSpecs
for additional options including shorter jumper cables and country specific
power cords:
https://h18000.www1.hp.com/products/quickspecs/11041_na/11041_na.html
(North America)
https://h18000.www1.hp.com/products/quickspecs/11041_div/11041_div.html
(Worldwide) |
|
|
Rack Enabling Kit
|
ProLiant ML310/ML330 G2 Rack Enabling
Kit |
238547-B22
|
NOTE: Support
for racks with round or square mounting holes (including all Compaq
and HP Rack System /E and HP Systems), with an adjustment range of
24" 36". |
|
|
Other |
ProLiant ML310 SCSI Cable Kit |
273463-B21
|
NOTE: This SCSI
Cable Kit (PN 273463-B21) is required when installing an internal tape drive
and a SCSI Controller.
NOTE: This kit is supported on the ML310 and ML330 G2 servers. |
|
Internal to External SCSI Cable
Option Kit (HD68)
|
159547-B22
|
Internal to External SCSI Cable
Option Kit (VHDCI) |
333370-B21
|
Telco Rack Option Kit |
251243-B21
|
NOTE: Support
for all 2-post Telco racks requires the use of the standard four post rack
kit and an additional option kit from HP. |
|
|
USB Options |
USB Optical Scroll Mouse (Carbonite) |
DD441B |
USB 1.44-MB External Diskette
Drive (Carbonite) |
DC141B
|
|
HP Rack 10000 Series (Graphite
Metallic) | HP Rack S10614
(14U) Rack Cabinet - Shock Pallet |
| HP
Rack 10842 (42U) Rack Cabinet - Pallet |
| HP
Rack 10842 (42U) Rack Cabinet - Shock Pallet |
| HP
Rack 10647 (47U) Pallet |
| HP
Rack 10647 (47U) Crated |
245160-B23 | HP
Rack 10642 (42U) Pallet |
| HP
Rack 10642 (42U) Shock Pallet |
| HP
Rack 10642 (42U) Crated |
245161-B23 | HP
Rack 10636 (36U) Pallet |
| HP
Rack 10636 (36U) Shock Pallet |
| HP
Rack 10636 (36U) Crated |
245162-B23 | HP
Rack 10622 (22U) Pallet |
| HP
Rack 10622 (22U) Shock Pallet |
| HP
Rack 10622 (22U) Crated |
245163-B23 | NOTE:
-B21 (pallet) used to ship empty racks shipped on a truck -B22 (shock
pallet) used to ship racks with equipment installed (by custom systems, VARs and
Channels) -B23 (crated) used for air shipments of empty racks | |
NOTE: Please
see the Rack 10000 QuickSpecs for Technical Specifications such as height, width,
depth, weight, and color: https://h18000.www1.hp.com/products/quickspecs/10995_div/10995_div.html
(Worldwide) https://h18000.www1.hp.com/products/quickspecs/10995_na/10995_na.html
(North America) | |
NOTE: For additional
information regarding Rack Cabinets, please see the following URL: https://h18000.www1.hp.com/products/servers/proliantstorage/racks/index.html. | |
|
Rack Options for HP
Rack 10000 Series
|
HP Rack Light Kit (Neon) |
|
HP Rack Plinth Kit (Carbon) |
|
42U Side Panel – Graphite Metallic
|
246099-B21
|
36U Side Panel – Graphite Metallic
|
246102-B21
|
47U Side Panel – Graphite Metallic
|
255486-B21
|
NOTE:
For additional information regarding
Rack Options, please see the following URL: https://h18000.www1.hp.com/products/servers/proliantstorage/rack-options/index.html. |
|
KVM USB Interface Adapter |
|
Server Console Switch 1 x 4 port (100-230 VAC)
|
400336-001
|
Server Console Switch, 0 x 1 x
8 port |
|
Server Console Switch, 0 x 2 x
16 port
|
|
Server Console Switch 1 x 4 port (100-230 VAC) (Int’l)
|
400336-B31
|
Server Console Switch 1 x 4 port (100-230 VAC) (Japan)
|
400336-291
|
IP Console Switch Box, 1 x 1 x 16
|
262585-B21
|
IP Console Switch Box, 3 x 1 x 16
|
262586-B21
|
IP Console Interface Adapter, 8 pack
|
262587-B21
|
IP Console Interface Adapter, 1 pack
|
262588-B21
|
IP Console Expansion Module
|
262589-B21
|
CPU to Server Console Cable, 12’
|
110936-B21
|
CPU to Server Console Cable, 3’
|
110936-B24
|
CPU to Server Console Cable, 7’
|
110936-B25
|
IP CAT5 Cable 3’, 4 pack
|
263474-B21
|
IP CAT5 Cable 6’, 8 pack
|
263474-B22
|
IP CAT5 Cable 12’, 8 pack
|
263474-B23
|
IP CAT5 Cable 20’, 4 pack
|
263474-B24
|
IP CAT5 Cable 40’, 1 pack
|
263474-B25
|
Switch Box Connector Kit (high voltage) (Int'l)
|
144007-B33
|
TFT5600 Rack Keyboard Monitor
|
221546-xx1
|
Country Code Key (for
TFT5600 Rack Keyboard Monitor (PN 221546-xx1)) |
|
XX = 001 |
US |
XX = 091 |
Norway |
XX = 031 |
UK |
XX = 101 |
Sweden/Finland |
XX = 041 |
Germany |
XX = 111 |
Switzerland |
XX = 051 |
France |
XX = 131 |
Portugal |
XX = 061 |
Italy |
XX = 181 |
Belgium |
XX = 071 |
Spain |
XX = 291 |
Japan |
XX = 081 |
Denmark |
XX = B31 |
International |
|
|
1U Rack Keyboard & Drawer
(Carbon)
|
257054-xx1
|
Country Code Key (for
1U Rack Keyboard & Drawer (PN 257054-xx1)) |
|
XX = 001 |
US |
XX = 091 |
Norway |
XX = 031 |
UK |
XX = 101 |
Sweden/Finland |
XX = 041 |
Germany |
XX = 111 |
Switzerland |
XX = 051 |
France |
XX = 131 |
Portugal |
XX = 061 |
Italy |
XX = 181 |
Belgium |
XX = 071 |
Spain |
XX = 291 |
Japan |
XX = 081 |
Denmark |
XX = B31 |
International |
|
|
NOTE: For additional
information regarding Rack Options, please see the following URL: https://h18000.www1.hp.com/products/servers/proliantstorage/rack-options/index.html. |
|
|
HP Factory Express |
Factory Installation, Racking, and Customization Services |
|
Factory Express Server Configuration Level 1 |
293355-888 | NOTE:
Free Installation of HP Options - Installation of HP Options memory, NICs, hard
drives, controllers, processors, I/O cards, pre-install standard OEM OS image,
and tape drives. Installation fees will apply to all non-HP certified hardware
and asset tags. | |
Factory Express Server Configuration
Level 2 | 266326-888 |
NOTE:
Includes Level 1 Customer Intent of a ProLiant server and options configuration,
OS installation, custom image download, IP addressing, network setting, and custom
packaging. Customer unique requirements (quick restore creation, cd duplication,
test reports, real-time reporting of server MAC address, password, and RILOE).
Customer access, validation and control through VPN (price/server). | |
|
Service
and Support Offerings (HP Care Pack Services) |
Hardware Services 4-Hour On-site Service |
| 9-Hour
x 5-Day Coverage, 3 Years (6-3 Part Number for U.S.) |
162676-002 | 9-Hour
x 5-Day Coverage, 3 Years (2-5-2 Part Number for Canada) |
FP-EL4HR-36 | 9-Hour
x 5-Day Coverage, 3 Years (6-3 Part Number for EMEA) |
324416-002 | 24-Hour
x 7-Day Coverage, 3 Years (6-3 Part Number for U.S.) |
162675-002 | 24-Hour
x 7-Day Coverage, 3 Years (2-5-2 Part Number for Canada) |
FP-EL724-36 | 24-Hour
x 7-Day Coverage, 3 Years (6-3 Part Number for EMEA) |
376910-022 | |
Hardware
Services Next Business Day On-Site Service |
| 9-Hour
x 5-Day Coverage, 3 Years (6-3 Part Number for U.S.) |
102407-002 | 9-Hour
x 5-Day Coverage, 3 Years (2-5-2 Part Number for Canada) |
FP-ELXHW-36 | 9-Hour
x 5-Day Coverage, 3 Years (6-3 Part Number for EMEA) |
206947-022 | Hardware
Installation (6-3 Part Number for US) |
401791-002 | Hardware
Installation (2-5-2 Part Number for Canada) |
FP-ELINS-IN | Hardware
Installation (6-3 Part Number for EMEA) |
Quote | Pre-installation
planning; unpack equipment, install most current Compaq HW options internal to
server at same time of server installation; assemble & test; basic user information
provided; Install & configure basic functionality of Win NT Operating System
plus up to 1 days start-up activity, configure print & network access services,
and orientation. (6-3 Part Number for U.S.) |
240013-002 | Pre-installation
planning; unpack equipment, install most current Compaq HW options internal to
server at same time of server installation; assemble & test; basic user information
provided; Install & configure basic functionality of Win NT Operating System
plus up to 1 days start-up activity, configure print & network access services,
and orientation. (2-5-2 Part Number for Canada) |
FM-MSTEC-01 | Pre-installation
planning; unpack equipment, install most current Compaq HW options internal to
server at same time of server installation; assemble & test; basic user information
provided; Install & configure basic functionality of Novell NetWare Operating
System plus up to 1 days start-up activity, configure print & network access
services, and orientation (6-3 Part Number for U.S.) |
240008-002 | Pre-installation
planning; unpack equipment, install most current Compaq HW options internal to
server at same time of server installation; assemble & test; basic user information
provided; Install & configure basic functionality of Novell NetWare Operating
System plus up to 1 days start-up activity, configure print & network access
services, and orientation (2-5-2 Part Number for Canada) |
FM-NSTEC-01 | Server
Installation and Set-Up (Installation of the server, installation of the appropriate
service tools, check to ensure device SW and firmware is loaded and installationof
the operating system software (6-3 Part Number for EMEA) |
204563-022 | |
HP
Care Pack Priority Services for ProLiant Servers Priority Level |
| 9
x 5 HW, 4-hr response, Next Available HW engineer; 9 x 5 Bronze Software Support
2-hr response for Windows NT, Windows 2000, Professional, Server or Advanced Server
Operating System, Next Available Specialist (6-3 Part Number for U.S.) |
239928-002 | 9
x 5 HW, 4-hr response, Next Available HW engineer; 9 x 5 Bronze Software Support
2-hr response for Windows NT, Windows 2000, Professional, Server or Advanced Server
Operating System, Next Available Specialist (2-5-2 Part Number for Canada) |
FM-M01E1-36 | 9
x 5 HW, 4-hr response, Next Available HW engineer; 9 x 5 Bronze Software Support
2-hr response for Novell NetWare Operating System, Next Available Specialist
(6-3 Part Number for U.S.) | 239968-002 |
9 x 5 4-hour H/W, 5 x 9 2-hour
O/S (NT & NetWare), Three Years (6-3 Part Number for EMEA.) |
179834-021 | |
HP
Care Pack Priority Services for ProLiant Servers Priority 24 Level |
| 24
x 7 HW, 4-hr response, Named HW engineer; 24 x 7 Bronze Software Support, 2-hr
response for Windows NT, Windows 2000, Professional, Server or Advanced Server
Operating System, Next Available Specialist (6-3 Part Number for U.S.) |
239930-002 | 24
x 7 HW, 4-hr response, Named HW engineer; 24 x 7 Bronze Software Support, 2-hr
response for Novell NetWare Operating System, Next Available Specialist (6-3 Part
Number for U.S.) | 239970-002 |
7 x 24 4-hour H/W, 7 x 24 2-hour
O/S (NT & NetWare), Three years (6-3 Part Number for EMEA) |
179839-022 | |
HP Care Pack Priority
Services for ProLiant Servers Priority Silver |
| 24
x 7 HW, 4-hr response, Named HW engineer; 24 x 7 Silver Software Support, 1-hr
response, Monday Friday, 8AM 5PM local time, 2-hr response after
hours for Windows NT, Windows 2000, Professional, Server or Advanced Server Operating
System, Technical Account Manager, Technical Newsletter, SW activity review, proactive
patch notification, 1 System Healthcheck per year (6-3 Part Number for U.S.) |
239932-002 | 24
x 7 HW, 4-hr response, Named HW engineer; 24 x 7 Silver Software Support, 1-hr
response, Monday Friday, 8AM 5PM local time, 2-hr response after
hours for Windows NT, Windows 2000, Professional, Server or Advanced Server Operating
System, Technical Account Manager, Technical Newsletter, SW activity review, proactive
patch notification, 1 System Healthcheck per year (2-5-2 Part Number for Canada) |
FM-M04E1-36 | 24
x 7 HW, 4-hr response, Named HW engineer; 24 x 7 Silver Subsequent System Support
for Windows NT, Windows 2000, Professional, Server or Advanced Server Operating
System (6-3 Part Number for U.S.) |
239934-002 | 24
x 7 HW, 4-hr response, Named HW engineer; 24 x 7 Silver Subsequent System Support
for Windows NT, Windows 2000, Professional, Server or Advanced Server Operating
System (2-5-2 Part Number for U.S.) |
FM-M24E1-36 | 24
x 7 HW, 4-hr response, Named HW engineer; 24 x 7 Silver Software Support, 1-hr
response, Monday Friday, 8AM 5PM local time, 2-hr response after
hours for Novell NetWare Operating System, Technical Account Manager, Technical
Newsletter, SW activity review (6-3 Part Number for U.S.) |
239972-002 | 24
x 7 HW, 4-hr response, Named HW engineer; 24 x 7 Silver Software Support, 1-hr
response, Monday Friday, 8AM 5PM local time, 2-hr response after
hours for Novell NetWare Operating System, Technical Account Manager, Technical
Newsletter, SW activity review (6-3 Part Number for Canada) |
FM-N04E1-36 | 24
x 7 HW, 4-hr response, Named HW engineer; 24 x 7 Silver Subsequent System Support
for Novell NetWare Operating System Operating System, Technical Account Manager,
Technical Newsletter, SW activity review (6-3 Part Number for U.S.) |
239974-002 | 24
x 7 HW, 4-hr response, Named HW engineer; 24 x 7 Silver Subsequent System Support
for Novell NetWare Operating System Operating System, Technical Account Manager,
Technical Newsletter, SW activity review (2-5-2 Part Number for Canada) |
FM-N24E1-36 | NOTE:
For more information, customer/resellers can contact https://www.hp.com/services/carepack. | |
|
Memory
HP ProLiant ML310 Models
|
Standard Memory
256-MB of 2-way PC2100 DDR SDRAM running at 266MHz, with Advanced ECC
capabilities Memory installed (1 x 256-MB SDRAM DIMM) (on 2.8GHz &
2.53GHz models).
Standard Memory Plus Optional
Memory
Up to 3328-MB memory is available with the optional installation of PC2100
Registered ECC DDR SDRAM DIMM Memory kits (on 2.8GHz & 2.53GHz models).
Standard Memory Replaced with Optional Memory
Up to 4096-MB of memory is available with the removal of the standard
128-MB or 256-MB of memory and the optional installation of PC2100 Registered
ECC DDR SDRAM DIMM Memory kits.
NOTE: Charts do not represent all
possible memory configurations.
|
ML310 G1 Memory
|
Slot
|
|
1
|
2
|
3
|
4
|
Standard
|
256MB
|
256 MB
|
Empty
|
Empty
|
Empty
|
Optional
|
3328 MB
|
256 MB
|
1024 MB
|
1024 MB
|
1024 MB
|
Maximum
|
4096 MB
|
1024 MB
|
1024 MB
|
1024 MB
|
1024 MB
|
Storage
|
|
|
A |
48x IDE (ATAPI) CD-ROM |
E |
1.44 MB Diskette Drive |
B, C, D |
Removable Media Bays (1.6"
each) |
0, 1 |
1'' Non-Hot Plug Drive Bays |
|
|
| Drive
Support | |
|
Quantity Supported |
Position Supported |
Controller
|
Removable Media |
| |
| 1.44-MB Diskette
Drive | Up to 1 | E | Integrated |
IDE (ATAPI) CD-ROM Drive | Up
to 2 | A, B, C, or D | Integrated
IDE (ATAPI) | DVD-ROM
Drive Option Kit | Up
to 2 | A, B, C, or D | Integrated
IDE (ATAPI) |
|
Hard Drives (SCSI Models only) |
Ultra320
SCSI Non-Hot Plug
(NOTE: These drives will run at
Ultra3 speeds, unless an optional Ultra320-capable controller is installed in
a PCI slot) |
| Quantity Supported |
Position Supported |
Controller
|
1-inch
36.4-GB 10,000 rpm
36.4-GB 15,000 rpm
72.8-GB 10,000 rpm
| Up
to 5 | 0,1, B, C, D |
Integrated Single Channel Wide Ultra3 SCSI Adapter (SCSI Models)
Smart Array 5302/128 Controller
Smart Array 5304/256 Controller Smart Array 641 Controller Smart Array
642 Controller
64-Bit/133Mhz Dual Channel Ultra320 SCSI Adapter
| |
Ultra320 SCSI Hot Plug
(These Hot Plug Drives are for use
in conjunction with the ML3xx Two Bay SCSI Drive Cage (PN 244059-B21). |
|
Quantity Supported |
Position Supported |
Controller
|
1-inch
300-GB 10,000 rpm
146.8-GB 10,000 rpm
72.8-GB 10,000 rpm
72.8-GB 15,000 rpm
36.4-GB 15,000 rpm
| Up
to 2 | A+ B (need to
move CD-ROM drive to C) |
Integrated Single Channel Wide
Ultra3 SCSI Adapter (SCSI Models)
Smart Array 5302/128 Controller
Smart Array 5304/256 Controller
Smart Array 641 Controller
Smart Array 642 Controller
64-Bit/133Mhz Dual Channel Ultra320 SCSI Adapter |
NOTE: On ATA
models, must install an optional PCI-based SCSI controller to use these drives.
NOTE: All U320 Universal Hard Drives are backward compatible to U2 or U3
speeds. U320 drives require an optional U320 Smart Array Controller or U320 SCSI
HBA to support U320 transfer rates. | | | | |
Hard Drives (ATA Models
only) | ATA/100 IDE
Non-Hot Plug |
| Quantity Supported |
Position Supported |
Controller
|
1-inch
160.0-GB
80.0-GB
40.0-GB | Up
to 4 | 0,1, B, C, D | Integrated
Dual Channel Ultra ATA-100 Adapter (ATA Models) |
NOTE: The ProLiant
ML310 supports a maximum of 130 GB capacity per ATA drive. When 160-GB ATA
hard drives (PN 366486-B21) are connected to the internal ATA RAID controller,
the ProLiant ML310 recognizes a capacity of 130-GB. |
|
External Storage
|
|
Quantity
Supported
|
Position
Supported
|
Host Controller or Adapter
|
Modular Smart Array 30 Family |
|
External |
Smart Array 642 Controller |
|
Maximum Storage Capacity - ATA Models
(SCSI Attached (StorageWorks Enclosure)) |
Internal |
520 GB (4 x 160.0
GB) (internal drive bays and removable media bays)
NOTE: The ProLiant ML310 supports
a maximum of 130 GB capacity per ATA drive. When 160-GB ATA hard drives
(PN 366486-B21) are connected to the internal ATA RAID controller, the ProLiant
ML310 recognizes a capacity of 130-GB. |
External |
29.400 TB (14 x 300
GB) x 7 (Requires additional SCSI controllers in slots) |
Total |
30.040 TB |
|
Maximum Storage Capacity - SCSI Models
(SCSI Attached (StorageWorks Enclosure)) |
Internal |
818.4 GB (2 x 300
GB hot-plug hard drives in optional 2x1 hot plug hard drive cage + 3 x 72.8
GB non-hot-plug hard drives) |
External |
29.400 TB (14 x 300
GB) x 7 |
Total |
30.218 TB |
|
Tape Drives |
NOTE: For an up-to-date listing of
the latest O/S Support details for each of the Tape Drives listed below,
please see the following:
https://www5.compaq.com/products/quickspecs/north_america/10233.html
(North America)
https://www5.compaq.com/products/quickspecs/division/10233.html
(Worldwide)
NOTE: For an up-to-date listing of the
latest O/S Support details for each of the Tape Storage Systems listed
below, please see the following:
https://www5.compaq.com/products/quickspecs/north_america/10809.html
(North America)
https://www5.compaq.com/products/quickspecs/division/10809.html
(Worldwide)
|
|
Quantity
Supported |
Position
Supported |
Controller
|
HP StorageWorks DAT 40 Tape Drive, Internal Hot-Plug
HP StorageWorks DAT 72 Tape Drive, Internal Hot-Plug
|
Up to 2
(With optional ML3xx Two Bay Hot Plug SCSI Drive Cage)
|
A & B |
Smart Array 5304/256 Controller
Smart Array 6402/128 Controller
Smart Array 6404/256 Controller
Smart Array 642 Controller
Smart Array 641 Controller
64-Bit/133-MHz Dual Channel Ultra320 SCSI Adapter
64-Bit/66-MHz Dual Channel Wide Ultra3 SCSI Adapter, Alternate OS |
|
|
|
|
HP StorageWorks DAT 72 Tape Drive,
Internal
HP StorageWorks DAT 40 Tape Drive, Internal
HP StorageWorks DAT 24 Tape Drive, Internal |
Up to 2 |
B, C, D |
64-Bit/133Mhz Dual Channel Ultra320
SCSI Adapter
64-Bit/66-MHz Dual Channel Wide Ultra3 SCSI Adapter, Alternate OS |
|
|
|
|
HP StorageWorks DLT VS80 Tape
Drive, Internal |
Up to 2 |
B, C, D |
64-Bit/133Mhz Dual Channel Ultra320
SCSI Adapter
64-Bit/66-MHz Dual Channel Wide Ultra3 SCSI Adapter, Alternate OS |
|
|
|
|
Ultrium 215, External
Ultrium 230, External
Ultrium 460, External |
Up to 2 |
External |
64-Bit/133Mhz Dual Channel Ultra320
SCSI Adapter
64-Bit/66-MHz Dual Channel Wide Ultra3 SCSI Adapter, Alternate OS
|
|
|
|
|
HP StorageWorks DAT 72 Tape Drive,
External
HP StorageWorks DAT 40 Tape Drive, External
HP StorageWorks DAT 24e Tape Drive, External |
Up to 2 |
External |
64-Bit/133Mhz Dual Channel Ultra320
SCSI Adapter
64-Bit/66-MHz Dual Channel Wide Ultra3 SCSI Adapter, Alternate OS
|
|
|
|
|
HP StorageWorks DLT VS80 Tape
Drive, External |
Up to 2 |
External |
64-Bit/133Mhz Dual Channel Ultra320
SCSI Adapter
64-Bit/66-MHz Dual Channel Wide Ultra3 SCSI Adapter, Alternate OS |
|
|
|
|
HP StorageWorks SDLT 320 Tape
Drive, External |
Up to 2 |
External |
64-Bit/133Mhz Dual Channel Ultra320
SCSI Adapter
64-Bit/66-MHz Dual Channel Wide Ultra3 SCSI Adapter, Alternate OS |
|
|
|
|
HP StorageWorks DAT 40x6 Tape
Autoloader, External |
Up to 2 |
External |
64-Bit/133Mhz Dual Channel Ultra320
SCSI Adapter
64-Bit/66-MHz Dual Channel Wide Ultra3 SCSI Adapter, Alternate OS |
Power Specifications
Part Number | 302199-001 |
Spare Kit |
216108-001 | Operational
Input Voltage Range (V rms) |
100-127V and 200-240V | Frequency
Range (Nominal) (Hz) | 47 to 63
(50/60) | |
|
Nominal
Input Voltage (Vrms) | 100 |
115 | 208 |
220 | 230 |
240 | Max
Rated Output Wattage Rating | 300 |
300 | 300 |
300 | 300 |
300 | Nominal
Input Current (A rms) | 4.7 |
4.0 | 2.2 |
2.0 | 1.9 |
1.8 | Max
Rated Input Wattage Rating (Watts) | 462 |
455 | 448 |
441 | 435 |
429 | Max.
Rated VA (Volt-Amp) | 471 |
464 | 457 |
450 | 444 |
437 |
Efficiency (%) | 65 |
66 | 67 |
68 | 69 |
70 |
Power Factor | 0.98 |
Leakage Current (mA) |
0.31 | 0.36 |
0.65 | 0.69 |
0.72 | 0.75 |
Maximum Inrush Current
(A peak) | 63 |
72 | 130 |
138 | 144 |
150 |
Maximum Inrush Current duration | 20 |
| Processor |
Memory | HDD |
PCI | PS |
| ML310
Fully Configured | 1 |
4 | 5 |
4 | 1 |
| Fully
Loaded System Input Wattage (W) | 274 |
270 | 266 |
262 | 258 |
255 | Fully
Loaded System Input Current (A rms) | 2.8 |
2.4 | 1.3 |
1.2 | 1.1 |
1.1 | Fully
Loaded System Thermal (BTU- Hr) | 935 |
921 | 908 |
894 | 881 |
869 |
Fully Loaded System VA (Volt-Amp) |
280 | 276 |
272 | 268 |
264 | 260 |
System Leakage with all
power supplies loaded (mA) | 0.31 |
0.36 | 0.65 |
0.69 | 0.72 |
0.75 |
System Inrush Current with all power supplies loaded (A) |
63 | 72 |
130 | 138 |
144 | 150 |
Power cord requirements |
Nema 5-15P to IEC320-C13 | Option
no./Spare no: 227099-001/187335-001 | | IEC320-C13
to IEC320-C14 | Option no./Spare no: 142257-001/142258-B21 |
Example of real input watts consumed versus rated watts consumed is available
via the online tool located at url: https://inline.compaq.com/pg/ecg/issd/power/psupply.asp
select system calculator for one of the systems and reference the green fields
at the bottom of the calculator. NOTES: * To review typical system
power ratings use the Active Answers Power Calculator which is available via the
online tool located at URL: https://h30099.www3.hp.com/configurator/powercalcs.asp.
To
drill down to calculators: Click on: "ProLiant Servers"
Click on the Server of interest. Example: ML310 Click
on: "Power Calculator" link (You may need to scroll down to see it.) |
|
Power Cords (13 Cord Sets) |
|
Country |
Power Cord Part Number
|
APD |
139867-006
|
APD |
100613-003
|
APD |
100614-003
|
Australia
|
100661-007
|
Europe
|
100614-003
|
France
|
100614-003
|
Germany
|
100614-003
|
Japan
|
139867-006
|
PRC |
139867-006 |
PRC |
100613-003 |
PRC |
100661-007 |
UK |
100613-003 |
US |
163719-002 |
Quickspecs
System Unit | Dimensions
(HxWxD) | 16.5 x
7.5 x 20.25 in (41.91 x 19.05 x 51.44 cm) |
Weight(approximate) | 34
lb (15.42 kg) | |
Input Requirements
(per power supply) | Range Line
Voltage | 100-127V and 200-240V |
Normal Line Voltage | 115
to 230 VAC | Line
Frequency | 50 to 60 Hz | |
Rated Input Current | <
6A RMS at 90VAC with maximum load | BTU
Rating | 1,560 BTU |
| SCSI
Connectors (SCSI Models only) | One
internal HD68 connectors | NOTE:
Support for either one internal or one external SCSI channel is available.
This is achieved using an internal to external SCSI cable option kit (PN 159547-B22)
and SCSI knockout bracket. | Power
Supply Output Power | Rated
Steady-State Power | 300W |
Maximum Peak Power | 400W |
Temperature Range | Operating | 50°
to 93° F (10° to 35° C) | Shipping | -40°
to 150° F (-40° to 66° C) | Relative
Humidity (non-condensing) | Operating | 20%
to 80% | Non-operating | 5%
to 90% | Acoustic
Noise | Idle (Fixed Disk
Drives Spinning) | |
L WAd
(BELS) | 5.0 |
L pAm
(dBA) | 34 |
Operating (Random
Seeks to Fixed Disks) | |
L
WAd (BELS) | 5.1 |
L
pAm (dBA) | 35 |
|
Non-Hot Plug Wide
Ultra320 SCSI Hard Drives |
36.4
GB 10K | Capacity |
36,419.2 MB |
271832-B21 |
Height | 1
in (2.54 cm) | | Width | 4
in (10.16 cm) | | Interface | Wide
Ultra3 SCSI | |
Transfer Rate Synchronous
(Maximum) |
320 MB/s |
| Seek
Time (typical reads, including settling) | Single
Track | 0.7 ms | Average | 5.4
ms | Full-Stroke | 11
ms | Rotational | 10,000
rpm | | Physical
Configuration | Bytes/Sector
| 512 | Logical
Blocks | 71,132,000 |
| Operating
Temperature | 50°
to 95° F (10° to 35° C) | | | |
36.4 GB 10K |
Capacity |
36419.5 MB |
176497-B21 |
Height | 1
in (2.54 cm) | | Width | 4
in (10.16 cm) | | Interface | Wide
Ultra3 SCSI | |
Transfer Rate Synchronous
(Maximum) | 160
MB/s | | Seek
Time (typical reads, including settling) | Single
Track | 0.7 ms | Average | 5.4
ms | Full-Stroke | 11
ms | Rotational | 10,000
rpm | | Physical
Configuration | Logical Blocks |
71,132,000 |
| Operating
Temperature | 50°
to 95° F (10° to 35° C) |
|
Non-Hot Plug ATA/100 Hard Drives | 40
GB 7.2K | Capacity | 40020
MB (phys.) 40800 MB (log) | 230534-B21 | Height | 1
in (2.54 cm) | | Width | 4
in (10.16 cm) | | Interface | Ultra
ATA/100 | | Transfer
Rate Synchronous (Maximum) | 100
MB/s | | Seek
Time (typical reads, including settling) | Single
Track | 0.8 ms | Average | 8.5
ms | Full-Stroke | 17.8
ms | Rotational | 7,200
rpm | | Physical
Configuration | Bytes/Sector
| 512 | Logical
Blocks | 78,177,792 |
| Operating
Temperature | 41°
to 131° F (5° to 55° C) |
|
48X Max IDE (ATAPI) CD-ROM Drive |
Disk | Applicable
Disk | CD-ROM, CD-XA, CD-DA (Mode
1, Mode 2, Form 1 and 2) |
| Photo CD (Single and Multi-session) |
| Mixed
Mode (Audio and Data combined) |
| | CD-R |
|
Capacity | 540 MB (Mode 1,
12 cm) | |
| 650 MB (Mode 2, 12 cm) |
Block Size |
Mode 1 | 2,048 bytes |
|
Mode 2 | 2,340 bytes, 2,336
bytes | |
CD-DA | 2,352 bytes |
| CD-XA | 2,328
bytes | Interface |
IDE (ATAPI) | |
Access Times (typical) |
Random | <100 ms |
Full-Stroke | <150
ms | Data
Transfer Rate | Sustained | 3000
to 7750 KB/s (20X to 48X) | Burst | 150
KBps to 7,200 KBps | Bus
Rate | 16.7 MBps |
Cache Buffer |
128 KB | |
Start-up Time (typical) |
< 7seconds | |
Stop Time | <
4seconds | |
Laser Parameters | Type | Semiconductor
Laser GaA1As | Wave
Length | 780 ± 25 nm |
Operating Conditions |
Temperature | 41° to 113°
F (5° to 45° C) |
Humidity | 10% to 80% |
Dimensions |
(HxWxD, maximum) | 1.7
x 5.85 x 8.11 in (4.29 x 14.86 x 20.60 cm) |
| Weight | 2.09
lb (0.95 kg) |
|
Integrated Dual Channel Ultra ATA-100 Adapter
(ATA Models only)
|
Drives Supported |
Up to 4 IDE devices (2 devices/channel) |
Channels |
2 (primary and secondary) |
Storage Capacity |
320 GB |
Data Transfer Method |
32-bit/33-MHz PCI bus-master |
Maximum ATA Channel Transfer Rate |
100 MB/s per channel |
Maximum Transfer Rate per PCI Bus
(peak) |
133 MB/s per channel |
ATA Protocols |
UDMA Mode[0-5] |
PIO Mode[0-4] |
ATA 100 Cable |
80-Conductor Cable |
Internal ATA Connectors |
Two 40-Pin Connectors (primary and
secondary) |
|
|
|
|
Integrated Single Channel Wide Ultra3 SCSI Adapter
(SCSI Models only)
|
Drives Supported |
Up to 7 SCSI devices Wide |
Data Transfer Method |
64-bit/33-MHz PCI bus-master |
SCSI Channel Transfer Rate |
160 MB/s per channel |
Maximum Transfer Rate per PCI
Bus (peak) |
267 MB/s per channel |
SCSI Protocols |
Wide Ultra3 SCSI, Wide Ultra2 SCSI,Wide
Ultra SCSI-3, Fast-Wide SCSI-2, and Fast SCSI-2 |
Fast SCSI-2 |
Electrical Protocol |
Low Voltage Differential (LVD) |
SCSI Termination |
Active Termination |
External SCSI Connectors |
None. |
NOTE: Buy extra
controller or internal to external SCSI option kit (part number 159547-B22). |
Internal SCSI Connectors |
One 68-Pin Wide Ultra SCSI-3 connectors |
|
|
|
|
|