DL QuickSpecs
|
DL20
|
|
DL60
|
|
DL80
|
|
DL120
|
|
DL140
|
|
DL145
|
|
DL160
|
|
DL160se
|
|
DL165
|
|
DL180
|
|
DL185
|
|
DL320
|
|
DL325
|
|
DL345
|
|
DL360
|
|
DL365
|
|
DL380
|
|
DL385
|
|
DL388
|
|
DL560
|
|
DL580
|
|
DL585
|
|
DL740
|
|
DL760
|
|
DL785
|
|
DL1000
|
|
|
ML QuickSpecs
|
ML30
|
|
ML110
|
|
ML115
|
|
ML150
|
|
ML310
|
|
ML330
|
|
ML350
|
|
ML370
|
|
ML530
|
|
ML570
|
|
ML750
|
|
|
BL QuickSpecs
|
BL10e
|
|
BL20p
|
|
BL25p
|
|
BL260c
|
|
BL280c
|
|
BL2x220c
|
|
BL30p
|
|
BL35p
|
|
BL40p
|
|
BL420c
|
|
BL45p
|
|
BL460c
|
|
BL465c
|
|
BL480c
|
|
BL495c
|
|
BL60p
|
|
BL620c
|
|
BL660c
|
|
BL680c
|
|
BL685c
|
|
BL860c
|
|
|
SL QuickSpecs
|
SL160z
|
|
SL165z
|
|
SL170s
|
|
SL170z
|
|
SL230s
|
|
SL250s
|
|
SL270s
|
|
SL2x170z
|
|
SL335s
|
|
SL390s
|
|
SL4540
|
|
SL4545
|
|
|
XL QuickSpecs
|
XL170r
|
|
XL190r
|
|
XL220a
|
|
XL230a
|
|
XL730f
|
|
XL740f
|
|
XL750f
|
|
|
CL QuickSpecs
|
CL1850
|
CL1850 G1
| |
CL380
|
CL380 G1
| |
|
|
|
|
|
|
|
Proliant DL740 G1 QuickSpecs |
US QuickSpecs |
|
|
|
|
|
|
|
|
|
Proliant DL740 G1 Overview
HP ProLiant DL740
|
1.
|
LED Diagnostic Display (system health and DIMM
status) |
2.
|
Unit ID (UID) LED Switch (front and rear) |
3.
|
Universal Media Bay Ejector Button |
4.
|
Redundant Hot Plug Power Supply #2
|
5.
|
1.44MB Diskette Drive
|
6.
|
Ultra3 Hard Disk Drive Bays (up to four)
|
7.
|
CD/DVD-ROM Drive in Universal Media Bay
(hot pluggable)
|
|
8.
|
Redundant Hot Plug Power Supply #1
|
9.
|
System Power LED Switch
|
10.
|
Processor Board #2
|
11.
|
Processor Board #1
|
12.
|
Six 100MHz/64-bit PCI-X slots |
13.
|
Redundant Hot Plug Fan #2 |
14.
|
Redundant Hot Plug Fan #1 |
15.
|
Hot Plug RAID Memory Cartridges
(five total) |
|
|
What's
New
- Intel® Xeon® Processor MP 3.0 GHz/4MB, 2.7
GHz/2MB, or 2.2 GHz/2MB Processors (eight processor capability)
|
At A Glance
- Uncompromising 8-way performance
and availability in an ultra dense, 4U form factor
- Intel Xeon Processor MP 3.0 GHz/4MB, 2.7 GHz/2MB,
2.2 GHz/2MB Processors (eight processor capability)
- HP developed F8 chipset
- 133 MHz SDRAM Memory, expandable to 64 GB addressable
memory
- HP Hot Plug RAID Memory Technology
- Hot Add, Hot Replace, and Hot Upgrade
- Uses industry standard ECC-protected memory
- Six 64-bit/100MHz PCI-X slots, all hot pluggable
- Integrated Lights-Out Standard Management (iLO) on
system board
- Two NC7781 PCI-X Gigabit NICs (embedded)
- Integrated Smart Array 5i Controller (Ultra3 support)
(supports RAID 0, 1, 1+0, and 5 across internal hard disk drives)
- Internal Hot Plug Drive Storage of 1.20TB (4 x 300GB
Ultra320 hard drives running at Wide Ultra3) or one DAT hot plug tape
drive and two hot plug hard drives
- Tool less and modular chassis for enhanced serviceability
- Innovative diagnostic lighting for rapid response
to service events
- Unit ID (UID) lighting, front and rear
- Front bezel system health/RAID memory LEDs
- Two 1100W/800W hot plug redundant power supplies
standard
- Two hot plug redundant system fans standard
- Rapid deployment racking solution (rack rails and
cable management)
- Protected by HP Services and a worldwide network
of resellers and service providers. Three-year Next Business Day, on-site
limited global warranty. Certain restrictions and exclusions apply.
Pre-Failure Notification on processors, memory, and SCSI hard drives.
|
Standard Features
Processor
One of the following depending
on Model
|
(4) Intel Xeon Processor MP
3.0 GHz/4MB |
(4) Intel Xeon Processor MP
2.7 GHz/2MB |
(4) Intel Xeon Processor MP
2.2 GHz/2MB |
|
Cache
Memory One
of the following depending on Model | 4MB
Integrated Level 3 cache (per processor) NOTE:
Available with 3.0 GHz models. | 2MB
Integrated Level 3 cache (per processor) NOTE:
Available with 2.7 GHz or 2.2 GHz models. |
|
Upgradeability |
Upgradeable to eight
processors |
|
Chipset |
HP developed F8
chipset |
|
Memory
Protection | Advanced ECC |
Hot Plug RAID Memory |
|
DL740 G1 Memory One
of the following depending on Model
| Type | 133MHz
ECC SDRAM DIMMs | Standard
(for 2.7 GHz and 3.0 GHz models) | 4
GB (2 x 512 MB x 5 HP RAID Memory Cartridges) (The 5th cartridge is populated
for redundancy) NOTE: Available with
3.0 GHz or 2.7 GHz models. | Standard
(for 2.2 GHz models only) | 2
GB (2 x 256 MB x 5 HP RAID Memory Cartridges) (The 5th cartridge is populated
for redundancy) NOTE: Available with
2.2 GHz model. | Maximum | 64
GB addressable (80 GB total) | NOTE:
All models come standard with all five memory cartridges populated and Hot
Plug RAID Memory enabled. NOTE: In standard Hot Plug RAID Memory mode,
addressable memory refers to the portion of memory that is addressable by the
OS. Total memory consists of addressable memory plus the redundant memory (stored
in the dedicated parity memory cartridge.) |
|
Network Controller |
Two NC7781 PCI-X
Gigabit NICs (embedded) |
|
Expansion Slots |
Slot Number
|
Bus Speed
|
Bus Number
|
Hot Plug
|
PCI Voltage
|
Notes
|
1
|
64-bit 100MHz
PCI-X
|
7
|
Yes
|
3.3V
|
|
2
|
64-bit 100MHz
PCI-X
|
7
|
Yes
|
3.3V
|
|
3
|
64-bit 100MHz
PCI-X
|
11
|
Yes
|
3.3V
|
|
4
|
64-bit 100MHz
PCI-X
|
11
|
Yes
|
3.3V
|
|
5
|
64-bit 100MHz
PCI-X
|
3
|
Yes
|
3.3V
|
|
6
|
64-bit 100MHz
PCI-X
|
3
|
Yes
|
3.3V
|
|
|
NOTE:
All slots can accept universal keyed PCI cards. |
|
Storage Controllers |
Smart Array 5i Controller
(integrated on system board), one internal channel, Ultra3 (supports RAID
0, 1, 1+0, and 5 across internal hard disk drives) |
Optional support for Ultra3
or Ultra320 storage controllers in an I/O slot to internal drives via array
bypass cable kit and required cables ships with all HP ProLiant DL740 in
the accessories package. |
|
Storage |
Diskette Drive |
1.44 MB Diskette Drive |
Optical Drive (in the Universal
Media Bay) |
Integrated Slimline CD/DVD-ROM
(8X/24X) Combo Drive Option Kit |
Hard Drives |
None |
|
Maximum Internal Storage Type |
Hot Plug SCSI |
1.20TB |
4 x 300GB Ultra320, Drives (internal
hot plug cage only) |
|
Interfaces |
Serial |
1 |
Pointing Device (Mouse) |
1 |
Graphics |
1 |
Hot Plug Keyboard |
1 |
USB (rear only) |
1 |
iLO remote management port |
1 |
Network RJ-45 |
2 |
|
Graphics |
Integrated ATI RAGE XL Video
Controller with 8-MB SDRAM Video Memory |
|
Form Factor |
4U (7") Rack Form Factor;
Ships with sliding rack rails and cable management system; Standard 19"
rack-mountable |
|
ProLiant Essentials
Foundation Pack Software |
HP Systems Insight Manager |
HP's new HP Systems Insight
Manager (HP SIM) helps maximize system uptime and performance and
reduce system maintenance costs by providing proactive notification
of problems before those problems result in unplanned downtime or
reduced productivity. HP SIM are both easy to set up work with the
Insight Management Agents, integrated Lights-Out and Remote Insight
Lights-Out Edition, and Version Control Agents to deliver robust fault,
configuration, and asset management as well as remote administration.
With HP SIM customers will also be able to take advantage of role-based
security; the ability to manage ProLiant, Integrity, and HP 9000 systems;
and plug-ins for storage, client, printer, and power management as
well as server rapid deployment, performance management, and workload
management. For more details on HP SIM visit https://www.hp.com/go/hpsim. |
|
SmartStart | SmartStart
is a tool that simplifies server setup, providing a rapid way to deploy reliable
and consistent server configurations. For more information, please visit the SmartStart
Web site at https://www.hp.com/servers/smartstart.
SmartStart version supported (minimum): SmartStart
6.20. |
|
Management Agents |
The Management Agents
form the foundation for HP's Intelligent Manageability strategy. They
provide direct, browser-based access to in-depth instrumentation built
into HP servers, workstations, desktops, and portables, and send alerts
to Systems Insight Manager and other enterprise management applications
in case of subsystem or environmental failures. For additional information
about the Management Agents and other management products from HP,
please visit the management Web site at https://www.hp.com/servers/manage. |
|
Subscriber's Choice | Subscriber's
Choice Driver and Support Alerts/Notifications is a web-based email subscription
service that provides automatic delivery of software and driver change notifications
for ProLiant products. Sign up at https://www.hp.com/go/subscriberschoice and
customize your profile to receive various new alerts as they become available,
on a weekly or monthly basis. | |
ROMPaq,
support software, and configuration utilities |
The latest software, drivers,
and firmware fully optimized and tested for your ProLiant server and
options available in SmartStart or downloadable from Software and
Drivers download pages, linked from the SmartStart website at https://www.hp.com/servers/smartstart. |
|
Survey
Utility and diagnostics utilities |
The most advanced configuration
analysis, reporting and troubleshooting utilities used by HP and at
your fingertips, available in SmartStart. |
|
Optional
ProLiant Essentials Value Packs |
Optional software offerings that selectively extend the functionality
of an Adaptive Infrastructure to address specific business problems
and needs:
- Rapid Deployment Pack - an automated solution for multi-server
deployment and provisioning, enabling companies to quickly and
easily adapt to changing business demands.
- Workload Management Pack - provides easier management of complex
environments, improving overall server utilization and enabling
Windows® 2000 customers for the first time to confidently
deploy multiple applications on a single multiprocessor ProLiant
Server.
- Integrated Lights-Out Advanced Pack - upgrades the Integrated
Lights-Out processor to full virtual presence and control with
graphical console and virtual media.
- Performance Management Pack - a performance management solution
that identifies and explains hardware performance bottlenecks
on ProLiant servers and attached options enabling users to better
utilize their valuable resources.
- Intelligent Networking Pack - detects and analyzes network bottlenecks
or broken network linkages and steers traffic to the optimum route
based on network conditions, plus it provides an extra layer of
protection. The virus throttle feature of the solution slows the
propagation of fast spreading virus
- Vulnerability and Patch Management Pack - identifies and remediates
software security vulnerabilities due to missing patches as well
operating system configurations that can be exploited by viruses,
worms, and other blended threats.
- Virtual Machine Management Pack - provides central management
and control of virtual machines from Microsoft and VMware. Integrated
approach provides the ability to manage both physical and virtual
resources from a single management console.
- Server Migration Pack - The Server Migration Pack automates
the manual processes required for migrating servers between physical
or virtual platforms (P2V, V2P, and V2V).
|
| NOTE:
Flexible and volume quantity license kits are available for ProLiant Essentials
Value Packs. Refer to https://www.hp.com/servers/proliantessentials
or the various ProLiant Essentials Value Pack product QuickSpecs for more information.
NOTE: For more information regarding ProLiant Essentials Software,
please see the following URL: https://www.hp.com/servers/proliantessentials
| |
Industry Standard Compliance |
ACPI 1.0b Compliant
PCI-X and PCI 2.2 Compliant
PAE Support
PXE Support
Microsoft® Logo certifications |
|
Intelligent
Manageability |
Integrated Lights-Out (iLO) Standard Management
|
- Virtual Text Remote Console
- Virtual Power Button Control
- Dedicated LAN Connectivity
- Automatic IP Configuration via DHCP/DNS/WINS
- Industry Standard 128-bit Secure Sockets Layer
(SSL) Security
- IML and iLO Event Logging
- Support for 12 user accounts with customizable access privilege
|
Integrated Lights-Out (iLO)
Advanced Pack (supports Advanced features such as Graphical Remote Console
and Virtual Floppy - available as a separate option)
HP Systems Insight Manager
Remote Insight Lights-Out Edition ll (optional)
ROM-Based Setup Utility (RBSU)
Integrated Management Log (IML)
Server Health logging
Automatic Server Recovery-2 (ASR-2)
System Interconnect Status Indicators
Remote-Flash Redundant ROM
Hot Spare Boot
(NOTE: Upon the event of a failed
processor or VRM in a multi-processing environment, the system will automatically
reboot and use the remaining good processor(s).)
Power Down Utility
Pre-Failure Warranty (covers processors, as well as
SCSI
hard drives and memory)
Dynamic sector repairing and drive parameter tracking (with Smart Array
controllers) |
|
Availability |
Hot Plug RAID Memory - delivering unsurpassed memory protection and server
availability:
- Uses industry standard ECC SDRAM DIMMs
- Fully redundant architecture, with no more performance overhead than
is currently experienced with ECC protection.
- Same level of redundancy as achieved with memory mirroring, at only
25% of the additional memory expense when compared to mirroring.
- Customer can choose to run in non-RAID memory mode by populating only
the first 4 memory cartridges.
- Hot Add
- Add a new bank of DIMMs while the server is running
- OS/Application enabled
- Hot Upgrade
- Upgrade from a lower capacity DIMM to a higher capacity DIMM while
the server is running
- OS/Application enabled
- Hot Replace
- Replace a failed DIMM while the server is running
- OS/Application transparent
|
Six 64-bit/100MHz PCI-X Hot
Plug slots with push button functionality
Dual Redundant Hot Plug Fans
Dynamic sector repairing and drive parameter tracking (with Smart Array
controllers)
Fault Tolerant Processor Power Modules
Redundant/adaptive load balancing NIC Support
Dual Redundant Hot Plug Power Supplies |
|
Serviceability |
- Innovative Diagnostic Lighting throughout server
- LED display on front bezel indicates system health and DIMM status
- LED display on memory cartridges indicates cartridge power and
attention status
- Tool-less, virtually cable-less interior design
- Tool-less access to interior of server
- Hot pluggable universal media bay (CD/DVD-ROM drive ships standard)
ejects without the use of tools
- Front access power supplies
- PCI Card Guides locks full length PCI cards in place during transit
- SCSI Drive Cage connects directly to system board no cables.
- Modular mechanical design allows tool-less access to major subsystems
for easy upgrades and servicing
- Host Module: Processor, Memory, and I/O Subsystems
- Power and Media Module: SCSI Backplane, Power Supplies, Universal
Media Bay
- Quick Deploy Racking System
- Tool-less design "snap in" rails
|
|
Security |
Power-on password
Diskette drive control
Diskette boot control
Network server mode
Security provision
Parallel and serial interface control
Administrator's password
Disk configuration lock
Hot plug access security |
|
Server Power Cords |
Two IEC to IEC Highline power
cords (PDU adapters) ship standard |
|
Power
Supply | Two Redundant Hot Plug
1100/800-Watt power supplies per system. Power supplies are load sharing and provide
1100 Watts of Redundant power for 220-volt input or 800 Watts of power for 115-volt
input.
NOTE: To ensure redundancy of server
power, HP requires that 200-240 VAC power be used for all deployments. This
will ensure that both power supplies can support up to their maximum configurations,
and remain in a redundant power supply state.
NOTE: A maximum of two power supplies are supported and ship standard
with each server. Use of 110V power is not recommended.
NOTE: Due to the increased power consumption of the new Intel Xeon
MP processors, power redundancy may not be supported on all server configurations
when using 115-120 VAC power. Please refer to the Power Supply Calculator
https://activeanswers.compaq.com/
to determine if your configuration is redundant.
NOTE: A maximum of two power supplies
are supported (shipped standard with each server). |
|
System Fans |
Two Hot-Plug redundant
fans ship standard. Two maximum supported. |
|
Rack
Airflow Requirements |
Rack 10000 series Cabinets
The increasing power of new high-performance processor technology requires
increased cooling efficiency for rack-mounted servers. The 10000 Series
Racks provide enhanced airflow for maximum cooling, allowing these racks
to be fully loaded with servers using the latest processors.
CAUTION: If a third-party rack is used,
observe the following additional requirements to ensure adequate airflow
and to prevent damage to the equipment:
- Front and rear doors: If your 42U server
rack includes closing front and rear doors, you must allow 830 square
inches (5,350 sq cm) of hole evenly distributed from top to bottom
to permit adequate airflow (equivalent to the required 64 percent
open area for ventilation).
- Side: The clearance between the installed
rack component and the side panels of the rack must be a minimum of
2.75 inches (7 cm).
CAUTION: Always use blanking panels
to fill all remaining empty front panel U-spaces in the rack. This arrangement
ensures proper airflow. Using a rack without blanking panels results in
improper cooling that can lead to thermal damage.
NOTE: For additional information,
refer to the Setup and Installation Guide or the Documentation CD provided
with the server, or to the server documentation located in the Support
section at the following URL: https://www5.compaq.com/products/servers/ProLiantdl740/index.html.
NOTE: Allow a minimum of 48 inches
(121.92 cm) clearance beyond the front of your rack to permit server installation
and removal. This applies to both individual rack installations as well
as when aligning rack rows so that the front doors are facing each other.
|
|
Factory Express Portfolio for
Servers and Storage |
HP Factory Express offers configuration, customization, integration and
deployment services for HP servers and storage products. Customers can
choose how their factory solutions are built, tested, integrated, shipped
and deployed.
Factory Express offers service packages for simple configuration, racking,
installation, complex configuration and design services as well as individual
factory services, such as image loading, asset tagging, and custom packaging.
HP products supported through Factory Express include a wide array of
servers and storage: HP Integrity, HP ProLiant, HP ProLiant Server Blades,
HP BladeSystem, HP 9000 servers as well as the MSA1000, VA7xxx, EVA, XP,
rackable tape libraries and configurable network switches.
For more information on Factory Express services for your specific server
model please contact your sales representative or go to https://www.hp.com/go/factory-express.
|
|
Service
and Support | This product is
covered by a global limited warranty and supported by HP Services and a worldwide
network of resellers and service providers. Hardware diagnostic support and repair
is available for three years from date of purchase. Support for software and initial
setup is available for 90 days from date of purchase. Additional support may be
covered under the warranty or available for an additional fee. Enhancements to
warranty services are available through HP Care Pack services or customized service
agreements. NOTE: Limited warranty includes
3 year parts, 3 year labor, 3-year on-site support Care Pack services provide
a range of life cycle support options that let you choose the service levels that
meet your business requirements, from basic to mission-critical. A full
range of HP Care Pack hardware and software services are available including:
- Installation and start up
- Education courses
- Extended onsite
hardware coverage hours from same business day 13 hours, 5 day to 24 hours, 7
days call window with options including 4-hour response or 6-hour Call To Repair
- Comprehensive range of software technical support for Microsoft, Linux, ProLiant
Essentials and VMWare-based IT solutions helping to deliver high level of application
availability. Response times range from 30 mins for critical problems to 2 hours.
- System Management, Performance Services and Mission Critical Support Solution
HP
Care Pack services include coverage for the HP branded hardware options qualified
for the server, purchased at the same time or afterward, internal to the enclosure,
as well as 22" and smaller external monitors and tower UPS options up to 3kVA;
these items will be covered at the same service level and for the same coverage
period as the server. Coverage of UPS Battery is not included, standard warranty
terms & conditions apply. For servers or storage systems installed within
a rack, service also covers all HP qualified rack options installed within the
same rack. | |
NOTE: For more information on HP Care Pack
services, contact any of our worldwide sales offices or resellers or visit our
worldwide Web site on the internet at: https://www.hp.com/hps/carepack NOTE:
For more complete information on HP Services offerings, customers and resellers,
please visit us at: https://www.hp.com/hps NOTE:
Additional information regarding worldwide limited warranty and technical support
is available at: https://h18004.www1.hp.com/products/servers/platforms/warranty/index.html
|
Models
DL740R01 X3.0-4MB,
4096MB (4P)
348445-B21 |
Processor(s) |
(4) Intel Xeon Processors MP
at 3.0 GHz standard (up to 8 supported) |
Cache Memory |
4-MB integrated Level 3 cache
(per processor) |
Memory |
4096 MB (Standard) to 64 GB
(Maximum) addressable protected 133MHz ECC SDRAM DIMM (5120 MB total) |
Network Controller |
Two NC7781 PCI-X Gigabit NICs
(embedded) |
Storage Controller |
Integrated Smart Array 5i Controller
(Ultra 3 support) (supports RAID 0, 1, 1+0, and 5 across internal hard disk
drives) |
Hard Drives |
None |
Internal Storage |
1.20 TB maximum (with optional
hard drives) |
Cache Accelerator |
2-MB Cache coherency accelerator
embedded on host board |
Optical Drive |
Slimline CD/DVD-ROM Drive (8X/24X) |
Diskette Drive |
1.44 MB Diskette Drive |
I/O Slots |
PCI-X |
Form Factor |
4U Rack Form Factor |
|
DL740R01 X2.7-2MB, 4096MB (4P)
348446-B21
|
Processor(s) |
(4) Intel Xeon Processors MP
at 2.7 GHz standard (up to 8 supported) |
Cache Memory |
2-MB Integrated Level 3 cache
(per processor) |
Memory |
4096 MB (Standard) to 64 GB
(Maximum) addressable protected 133MHz ECC SDRAM DIMM (5120 MB total) |
Network Controller |
Two NC7781 PCI-X Gigabit NICs
(embedded) |
Storage Controller |
Integrated Smart Array 5i Controller
(Ultra 3 support) (supports RAID 0, 1, 1+0, and 5 across internal hard disk
drives) |
Hard Drives |
None |
Internal Storage |
1.20 TB maximum (with optional
hard drives) |
Cache Accelerator |
2-MB Cache coherency accelerator
embedded on host board |
Optical Drive |
Slimline CD/DVD-ROM Drive (8X/24X) |
Diskette Drive |
1.44 MB Diskette Drive |
I/O Slots |
PCI-X |
Form Factor |
4U Rack Form Factor |
|
DL740R01 X2.2-2MB,
2048MB (4P)
348447-B21 |
Processor(s) |
(4) Intel Xeon Processors MP
at 2.2 GHz standard (up to 8 supported) |
Cache Memory |
2-MB Integrated Level 3 cache
(per processor) |
Memory |
2048MB (Standard) to 64 GB (Maximum)
addressable protected 133MHz ECC SDRAM DIMM (5120 MB total) |
Network Controller |
Two NC7781 PCI-X Gigabit NICs
(embedded) |
Storage Controller |
Integrated Smart Array 5i Controller
(Ultra 3 support) (supports RAID 0, 1, 1+0, and 5 across internal hard disk
drives) |
Hard Drives |
None |
Internal Storage |
1.20 TB maximum (with optional
hard drives) |
Cache Accelerator |
2-MB Cache coherency accelerator
embedded on host board |
Optical Drive |
Slimline CD/DVD-ROM Drive (8X/24X) |
Diskette Drive |
1.44 MB Diskette Drive |
I/O Slots |
PCI-X |
Form Factor |
4U Rack Form Factor |
|
Options
HP
ProLiant DL740 Unique Options |
Low
Line (115V) Cable Kit, C-13 to 5-15P |
317424-001 | DL740
Folding Metal Cable Management Arm | 321716-B21 |
NOTE:
The Low Line Cable Kit consists of a single, 9 foot, IEC C-13 to 5-15P,
10 Amp cord. HP highly recommends running your HP ProLiant DL740 at high
line (220V) voltage to ensure power redundancy for all of your robust, business-critical
configurations. Because of the increasing power requirements of the memory
and microprocessor subsystems, the HP ProLiant DL740 does not support power
redundancy for all configurations when running at low line voltage. Please
refer to the Power Supply Calculator
https://h71019.www7.hp.com/ActiveAnswers/cache/71108-0-0-0-121.aspx
to determine if your low line configuration is redundant. |
| |
ProLiant
Essentials
Value Pack Software |
ProLiant Essentials
Integrated Lights-Out Advanced Pack |
|
ProLiant Essentials
Integrated Lights-Out Advanced Pack, 1 server
Featuring:
sophisticated virtual administration features for ultimate control of servers
in the data centers and remote sites. |
|
NOTE:
For additional ProLiant Integrated Light-Out Advanced Pack License Kits
please see the QuickSpecs at: https://h18000.www1.hp.com/products/quickspecs/11052_na/11052_na.html
|
|
ProLiant Essentials
Intelligent Networking Pack |
|
ProLiant Essentials
Intelligent Networking Pack - Windows Edition, Single Server License
NOTE: For use with a single server. Contains one license with a unique
license activation key and documentation. |
372906-B21
|
NOTE:
For additional ProLiant Intelligent Networking Pack - Windows License
Kits please see the QuickSpecs at: https://h18000.www1.hp.com/products/quickspecs/12062_na/12062_na.html
|
|
ProLiant Essentials
Intelligent Networking Pack - Linux Edition, Single Server License |
397004-B21
|
NOTE:
For additional ProLiant Intelligent Networking Pack - Linux License
Kits please see the QuickSpecs at:
https://h18000.www1.hp.com/products/quickspecs/12327_na/12327_na.html
|
|
ProLiant Essentials
Performance Management Pack |
|
ProLiant Essentials
Performance Management Pack, Single-Server License
NOTE: For use with a single server.
Contains one license with a unique license activation key, HP Management
CD and documentation.
NOTE: The most recent version of the software can always be downloaded
at https://www.hp.com/products/pmp. |
|
NOTE:
For additional ProLiant Performance Management Pack License Kits please
see the QuickSpecs at: https://h18000.www1.hp.com/products/quickspecs/11925_na/11925_na.html
|
|
ProLiant Essentials
Rapid Deployment Pack Windows Edition and Linux Edition Release |
|
Rapid Deployment
Pack, Single-Server License
NOTE: This license allows 1 server
to be deployed and managed via RDP. |
|
Rapid Deployment
Pack, Single-Server License (Japan)
NOTE: This license allows 1 server to be deployed and managed via
RDP. |
|
NOTE:
For additional ProLiant Essentials Rapid Deployment Pack License Kits please
see the QuickSpecs at: https://h18000.www1.hp.com/products/quickspecs/11053_na/11053_na.html
https://h18000.www1.hp.com/products/quickspecs/11713_na/11713_na.html |
|
ProLiant Essentials
Workload Management Pack |
|
ProLiant Essentials
Workload Management Pack, Single Server License |
|
NOTE:
For additional ProLiant Workload Management Pack License Kits please see
the QuickSpecs at: https://h18000.www1.hp.com/products/quickspecs/11452_na/11452_na.html
|
|
ProLiant Essentials
Virtualization Management Software |
|
ProLiant Essentials
Virtual Machine Management Pack, Single-Server License
NOTE: For use with a single server.
Contains one license with a unique license activation key and documentation. |
372214-B21
|
ProLiant Essentials
Server Migration Pack, Single-Migration License
NOTE: Contains one license, enabling 1 server migration, with a unique
license activation key and documentation.
NOTE: This license allows 1 server to be migrated from a physical
server to a virtual machine. Or this license can be used to migrate a virtual
machine from one virtualization layer i.e. VMware GSX to a different virtualization
layer such as VMware ESX or Microsoft Virtual Server 2005. |
375345-B21
|
NOTE:
For additional ProLiant Essentials Virtualization Management Software
License Kits please see the QuickSpecs at: https://h18000.www1.hp.com/products/quickspecs/12328_na/12328_na.html |
|
ProLiant Essentials
Vulnerability and Patch Management Pack |
|
ProLiant Essentials
Vulnerability and Patch Management Pack, Single-Server License
NOTE: For use with a single server.
Contains one license with a unique license activation key and documentation.
|
371645-B21
|
NOTE:
For additional ProLiant Vulnerability and Patch Management Pack License
Kits, please see the QuickSpecs at: https://h18000.www1.hp.com/products/quickspecs/12111_na/12111_na.html
|
|
NOTE:
Flexible and volume quantity license kits are available for ProLiant Essentials
Value Packs. Refer to https://www.hp.com/servers/proliantessentials
or the various ProLiant Essentials Value Pack product QuickSpecs for more
information.
NOTE: For more information regarding ProLiant Essentials Software,
please see the following URL: https://www.hp.com/servers/proliantessentials. |
|
|
HP NetServer integration
Services |
HP NetServer to ProLiant integration
and assessment service
NOTE: HP identifies current levels
of NetServer support, services, and management. This service helps maximize
customer's ability to add ProLiant platforms into their current environment. |
304164-002
|
HP TopTools to Insight Manager
7 installation and startup service
NOTE: Provides on-site review, installation
and configuration services for Insight Manager 7. HP will also re-create,
as closely as possible, the views and reports from the customer's current
TopTools configuration. This service assures a smooth transition to the
ProLiant Essentials software. |
304163-002
|
|
Memory
(SDRAM DIMMs)
|
2048 MB 133MHz ECC SDRAM Memory
Option Kit (1 x 2048 MB) |
|
1024 MB 133MHz ECC SDRAM Memory
Option Kit (1 x 1024 MB) |
|
512 MB 133MHz ECC SDRAM Memory
Option Kit (1 x 512 MB) |
|
256 MB 133MHz ECC SDRAM Memory
Option Kit (1 x 256 MB) |
|
NOTE: Memory must
be populated in banks of 10. (2 per memory cartridge x 5 cartridges) All
DIMMs in a bank must be the same sku number. |
|
|
Optical Drives |
HP DVD+R/RW 8X Slim |
|
Slimline DVD-ROM Drive (8X/24X)
Option Kit (Servers) |
|
|
Hard
Drives | Ultra320 SCSI –
Universal Hot Plug | |
HP 300GB U320 10K Universal HDD
| |
HP 146GB U320 10K Universal HDD
| |
HP 72GB U320 10K Universal HDD
| |
HP 146GB U320 15K Universal HDD
| |
HP 72GB U320 15K Universal HDD
| |
HP 36GB U320 15K Universal HDD |
|
NOTE: All U320 Universal Hard Drives are backward compatible to U2 or U3
speeds. U320 drives require an optional U320 Smart Array Controller or U320 SCSI
HBA to support U320 transfer rates. |
| NOTE:
Please see the Hard Drive QuickSpecs for Technical Specifications such as
capacity, height, width, interface, transfer rate, seek time, physical configuration,
and operating temperature: https://h18000.www1.hp.com/products/quickspecs/11531_na/11531_na.html |
|
|
Storage
Controllers | Smart Array 6402/128
Controller | 273915-B21 |
Smart Array 6404/256 Controller |
| 512MB
DDR BBWC Upgrade | |
Smart Array 641 Controller |
| Smart
Array 642 Controller | |
128MB Battery-Backed Cache Enabler
NOTE: This 128MB BBWC supports the Smart
Array 641 Controller and Smart Array 642 Controller. |
| 256-MB
Battery-Backed Cache Module NOTE: This
256-MB Battery-Backed Cache Module supports the Smart Array 5300 series controllers,
HP StorageWorks Modular Smart Array 1000 and the HP StorageWorks Modular Smart
Array 500. | |
64-Bit/133Mhz Dual Channel Ultra320
SCSI Adapter NOTE: The 64-bit/133-MHz
Dual Channel Wide Ultra320 SCSI Adapter ( 268351-B21) will default to Wide Ultra2
when not used with the Wide Ultra3 hard drives. |
| Ultra320
Expansion Module for SA-6402 | 273911-B21 |
NOTE: Please
see the following Controller or SCSI Adapter QuickSpecs for Technical Specifications
such as PCI Bus, PCI Peak Data Transfer Rate, SCSI Protocols supported, SCSI Peak
Data Transfer Rate, Channels, SCSI Ports, Drives supported, Cache, RAID support,
and additional information: https://h18000.www1.hp.com/products/quickspecs/11587_na/11587_na.html
(Smart Array 6400 Series) https://h18000.www1.hp.com/products/quickspecs/12067_na/12067_na.html
(Smart Array 641) https://h18000.www1.hp.com/products/quickspecs/12069_na/12069_na.html
(Smart Array 642) https://h18000.www1.hp.com/products/quickspecs/10429_na/10429_na.html
(SCSI Adapter) https://h18000.www1.hp.com/products/quickspecs/11555_na/11555_na.html
(U320 Adapter) | |
|
Communications |
HP NC150T PCI 4-port Gigabit 1000T
Combo Switch Adapter |
|
HP NC310F PCI-X 1000SX Gigabit
Server Adapter |
|
HP NC7170 PCI-X Dual Port 1000T
Gigabit Server Adapter |
|
HP NC7771 PCI-X 1000T Gigabit
Server Adapter |
|
NOTE: Any NIC
on the option list can be used for redundancy with the embedded NC7781 Network
Controller. |
|
HP NC570C PCI-X Dual-port 4x Fabric
Adapter |
376158-B21
|
HP 24-Port 4x Fabric Copper Switch
|
376227-B21
|
HP 1m 4x Fabric Copper Cable |
376232-B21
|
HP 3m 4x Fabric Copper Cable |
376232-B22
|
HP 5m 4x Fabric Copper Cable |
376232-B23
|
|
Management Options
|
Remote Insight Lights-Out Edition II
|
227251-001
|
|
Tape Drives
|
NOTE:
For the complete listing of Tape Drive offerings for this server,
please visit:
https://www.hp.com/products1/storage/compatibility/tapebackup/ISS/index.html
For recommended tape drive offerings
for this ProLiant server see the following:
|
|
Hot Plug Tape Drives |
|
HP StorageWorks DAT 72 SCSI
Hot-plug Tape Drive (Carbon) |
|
USB Tape Drives |
|
HP StorageWorks DAT 72 USB
External Tape Drive (Carbonite) |
|
External and Rack-Mount
Ultrium Tape Drives |
|
HP StorageWorks Ultrium
232 Internal Tape Drive (Carbonite)
NOTE: No internal tape drives
fit inside this HP ProLiant server (except hot plug tape). The internal
drive shown here is for the 1U and 3U Rack-mount Kit. |
|
HP StorageWorks Ultrium
232 External Tape Drive (Carbonite) |
|
HP StorageWorks Ultrium
448 External Tape Drive (Carbonite) |
DW017B
|
HP StorageWorks Ultrium
960 External Tape Drive (Carbonite) |
|
HP StorageWorks 3U Rack-mount
kit with one Ultrium 960 (Carbonite) |
|
NOTE:
Please see the HP StorageWorks Ultrium Tape Drive QuickSpecs for additional
options such as controllers, media, and other related items:
https://h18006.www1.hp.com/products/quickspecs/11739_na/11739_na.html
For an up-to-date listing of the latest O/S and software support details
for HP Ultrium tape drives, please visit: https://www.hp.com/go/connect.
|
|
Rack-Mount Tape Drive
Enclosures |
|
HP
StorageWorks 1U Rack-Mount Kit
NOTE: The 1U Rack-mount Kit can support up to (2) half-height
tape drives and compatible with multiple Single-Ended and LVD SCSI
tape drives including the DAT 24, DAT 40, DAT 72, DLT VS80, DLT VS160,
Ultrium 215, Ultrium 232 and Ultrium 448 tape drives. |
|
HP StorageWorks 1U USB Rack-Mount
Kit |
|
1U USB Cable Option Kit
NOTE: Converts a 1U SCSI rack-mount
kit to a USB interface to support the USB tape drives. |
|
HP StorageWorks 3U Rack-Mount
Kit
NOTE: The 3U Rack-mount Kit
can support up to (2) full-height or (4) half-height tape drives and
compatible with multiple Single-Ended and LVD SCSI tape drives including
DAT 24, DAT 40, DAT 72, DLT VS80, DLT VS160, SDLT 320, SDLT 600, Ultrium
215, Ultrium 230, Ultrium 232, Ultrium 460, Ultrium 448 and Ultrium
960 tape drives. |
274338-B22
|
NOTE: Please
see the Rack-Mount Tape Drive Kits QuickSpecs for additional information
regarding these kits:
https://h18000.www1.hp.com/products/quickspecs/10854_na/10854_na.html |
|
|
|
Tape Autoloaders |
DAT Autoloader |
|
HP StorageWorks DAT 72x6 Autoloader
(External) |
Q1567A |
NOTE: Please
see the DAT Tape Autoloader QuickSpecs for additional options such as host
bus adapters, controllers and media:
https://h18000.www1.hp.com/products/quickspecs/11985_na/11985_na.html
|
|
HP StorageWorks 1/8 Tape Autoloader |
|
HP StorageWorks 1/8 Ultrium 960
Tape Autoloader |
AF204A |
HP StorageWorks 1/8 Ultrium 448
Tape Autoloader |
AF203A |
HP StorageWorks 1/8 Ultrium 232
Tape Autoloader |
AF202A |
1/8 Tape Autoloader Rackmount
Kit
NOTE: Required to install the unit in a standard 19-inch rack; includes
rails and rackmount instructions |
C9268R |
NOTE: Please reference
the 1/8 Tape Autoloader QuickSpecs at https://www.hp.com/go/automation
for additional information needed to create a complete solution; reference
current compatibility information at https://www.hp.com/go/ebs. |
|
|
Ultra
Density Optical Jukeboxes | 1900ux,
4 drive, 64 slot jukebox | AA966A |
3800ux, 4 drive, 128 slot jukebox | AA969A |
7100ux, 6 drive, 238 slot jukebox
| AA971A |
NOTE: Please
see the HP StorageWorks Ultra Density Optical Jukeboxes QuickSpecs for a complete
listing of available jukeboxes at: https://h18006.www1.hp.com/products/quickspecs/11944_na/11944_na.html
NOTE: Please reference the Ultra Density Optical Jukebox QuickSpecs at:
https://www.hp.com/go/optical for additional
information needed to create a complete solution. | |
|
HP
Data Protector Express Software | HP
DP Express Backup Server Upgrade for ProLiant Software | BB117AP |
HP DP Express Package for Microsoft
Small Business Server | BB118AA |
NOTE: Please
see the HP Data Protector Express QuickSpecs for additional information regarding
the purchase of HP Data Protector Express software: https://h18000.www1.hp.com/products/quickspecs/12337_na/12337_na.html
| |
|
HP StorageWorks Modular
Smart Array 20 |
HP StorageWorks Modular Smart
Array 20
NOTE: Rack-mountable 12 (SATA) drive
enclosure with U320 Host connectivity, redundant power supplies.
|
335921-B21 |
HP StorageWorks Modular Smart
Array 20 Starter Kit
NOTE: Rack-mountable 12 (SATA) drive
enclosure with U320 Host connectivity, redundant power supplies. Includes
Smart Array 6402/128 Controller.
|
366172-B21 |
NOTE: The Modular Smart Array Enclosure 20 Family
supports the SATA 1.5Gb/s 3.5”
Hot Plug
Hard Drives. |
|
|
HP
StorageWorks Modular Smart Array 30 | HP
StorageWorks Modular Smart Array 30 SB NOTE:
Rack-mountable 14 drive enclosure with single bus, redundant power supplies. | 302969-B21 |
HP StorageWorks Modular Smart
Array 30 DB NOTE: Rack-mountable 14
drive enclosure with dual bus, redundant power supplies. | 302970-B21 |
NOTE: The Modular
Smart Array Enclosure 30 Family supports the Wide Ultra3, Ultra320 Hot Plug Hard
Drives. | |
|
HP StorageWorks Modular Smart Array 500
|
HP StorageWorks Modular Smart
Array 500 Generation 2
|
335880-B21
|
NOTE:
Please see the Modular Smart Array 500 Generation 2 QuickSpecs for additional
information including configuration steps and additional options needed
for a complete solution at:
https://h18000.www1.hp.com/products/quickspecs/11956_na/11956_na.html
|
|
|
HP StorageWorks Modular Smart Array 1500 cs
|
Modular Smart Array 1500 Controller Shelf
|
AA986A
|
NOTE: Please see
the StorageWorks Modular SAN Array 1500 cs QuickSpecs for additional options
and configuration information at:
https://www.hp.com/go/MSA1500cs
|
|
|
Uninterruptible Power
Systems – Rack Mountable |
HP UPS R1500 XR (1440VA, 1340 Watt), Low Voltage
|
204404-001
|
HP UPS R3000 XR (2880VA, 2700 Watt), Low Voltage
|
192186-001
|
HP UPS R3000 XR (3000VA, 2700 Watt), High Voltage
|
192186-002
|
HP UPS R5500 XR, (5000VA, 4500
Watt), High Voltage |
326529-D71 |
HP UPS R12000 XR N+x (200-240V)
(hardwired)
NOTE: The
UPS R12000 XR has a hardwired input and output; requires a 100A circuit. |
207552-B22
|
|
HP Monitored Power
Distribution Unit (PDU) |
HP Monitored Power Distribution
Unit: Full Rack Version |
|
HP 17.3 kVA S2324 Monitored PDU-
dual input, 3-phase, 24A |
|
HP 8.3 kVA S1324 Monitored PDU-
single input, 3-phase, 24A |
|
HP 16.6 kVA S2140 Monitored PDU-
dual input, 1-phase, 40A |
|
HP 8.6 S1140 Monitored PDU- single
input, 1-phase, 40A |
|
HP Monitored Power Distribution
Unit: Half Rack Version |
|
HP 17.3 kVA S348 Monitored PDU-
single input, 3-phase, 60A |
|
|
Modular Power Distribution Units - 1U0U
(Up to 32 outlets)
NOTE: 1U/0U mounting brackets
shipped with
the unit (optimized for 10000 and 9000 series racks).
|
HP Modular Power Distribution Units (mPDU), Low Volt Model, 24A (100-127
VAC)
NOTE: This mPDU ( 252663-D71) may
also be used to connect the low volt model of the UPS R3000 XR.
|
252663-D71
|
HP Modular Power Distribution Units (mPDU), High Volt Model, 24A (200-240
VAC)
|
252663-D72
|
HP Modular Power Distrib, (NA/JPN) |
252663-D73
|
NOTE: Please see
the following Modular Power Distribution Unit (Zero-U/1U Modular PDUs) QuickSpecs
for additional options including shorter jumper cables and country specific
power cords:
https://h18000.www1.hp.com/products/quickspecs/11041_na/11041_na.html |
|
|
Third Party Rack Kit
|
Third Party Rack Kit
NOTE: The Third party rack kit supports
the HP ProLiant ML530 G2, HP ProLiant ML570 G2, HP ProLiant DL740, and HP
ProLiant DL760 G2. Provides support for any rack, square hole or round hole
(including HP Rack System /E and HP Systems) with an adjustment range from
23 ½" - 34" deep.
NOTE: The Third Party Rack Kit is required for round hole racks or
for square hole racks that do not conform to the adjustment range of the
standard rail that ships with the server.
Telco Rack Support:
NOTE: Support for all 2-post Telco racks requires the Third Party
Rack Kit (PN 274739-B21) kit plus an additional option kit from Rack Solutions.
The Rack Solutions brackets can be purchased at: https://www.racksolutions.com/hp. |
274739-B21
|
|
Rack Adapter Kit
NOTE: This kit allows HP rack servers
to fit in racks that are 24" wide.
|
332815-B21 |
|
HP
Rack 5000 Series (Graphite Metallic) | HP
5642 Rack-Unassembled NOTE: Please see
the HP Rack 5642 QuickSpecs for additional part numbers and Technical Specifications
such as height, width, depth, weight, and color: https://h18000.www1.hp.com/products/quickspecs/12074_na/12074_na.html
NOTE: For additional information regarding Rack Cabinets, please see
the following URL: www.hp.com/go/rackandpower.
|
|
| HP
Rack 10000 G2 Series (Carbon/Graphite Metallic) | 10642
G2 (42U) Rack Cabinet - Pallet |
| 10642
G2 (42U) Rack Cabinet - Shock Pallet |
| 10642
G2 (42U) Rack Cabinet - Crated |
AF003A | 10642
G2 (42U) Rack Cabinet, with Extension - Shock Pallet |
| 10642
G2 (42U) Rack Cabinet, without door - Shock Pallet |
AF005A | 10642
G2 (42U) Rack Cabinet - with Extension, without door - Shock Pallet |
AF006A | 10636
G2 (36U) Rack Cabinet - Pallet |
| 10636
G2 (36U) Rack Cabinet - Shock Pallet |
| 10636
G2 (36U) Rack Cabinet - Crated |
| 10636
G2 (36U) Rack Cabinet , with Extension - Shock Pallet |
| 10636
G2 (36U) Rack Cabinet, without door - Shock Pallet |
AF015A | 10636
G2 (36U) Rack Cabinet, with Extension, without door - Shock Pallet |
AF016A | NOTE:
It is mandatory to use a shock pallet when shipping racks with equipment installed.
| |
NOTE: Please
see the Rack 10000 G2 QuickSpecs for Technical Specifications such as height,
width, depth, weight, and color: https://h18000.www1.hp.com/products/quickspecs/12402_na/12402_na.html
| |
NOTE: For additional
information regarding Rack Cabinets, please see the following URL: https://www.hp.com/go/rackandpower. |
|
|
HP Rack 10000 Series (Graphite
Metallic) | 10642 (42U)
Infrastructure Rack (Low Voltage) |
379006-001 | 10642
(42U) Infrastructure Rack (High Voltage) |
| HP
Rack S10614 (14U) Rack Cabinet Shock Pallet |
|
HP Rack 10842 (42U, 800mm wide) – Pallet |
257415-B21
|
HP Rack 10842 (42U, 800mm wide) – Shock Pallet |
257415-B22
|
HP Rack 10647 (47U) – Pallet |
245160-B21
|
HP Rack 10647 (47U) – Crated |
245160-B23 |
HP Rack 10642 (42U) – Pallet |
245161-B21
|
HP Rack 10642 (42U) – Shock Pallet |
245161-B22
|
HP Rack 10642 (42U) – Crated |
245161-B23 |
HP Rack 10636 (36U) – Pallet |
245162-B21
|
HP Rack 10636 (36U) – Shock Pallet |
245162-B22
|
HP Rack 10636 (36U) – Crated |
245162-B23 |
HP Rack 10622 (22U) – Pallet |
245163-B21
|
HP Rack 10622 (22U) – Shock Pallet |
245163-B22
|
HP Rack 10622 (22U) – Crated |
245163-B23 | NOTE:
xxxxxx-B21 (pallet) used to ship empty racks shipped on a truck. -B22 (shock pallet)
used to ship racks with equipment installed (by custom systems, VARs and Channels).
xxxxxx-B23 (crated) used for air shipments of empty racks. NOTE: It
is mandatory to use a shock pallet in order to ship racks with equipment installed.
Not all HP equipment is qualified to be shipped in the Rack 10000 series. NOTE:
For additional information regarding Rack Options, please see the following URL:
https://www.hp.com/go/rackandpower |
|
|
Keyboards and Monitors | TFT7210R
Rack Mounted 17" Monitor NOTE:
For a complete list of Monitors please view the following URL: https://www.hp.com/go/kvm. | |
TFT7600RKM US | |
TFT7600RKM UK | AG053A | TFT7600RKM
GR | AG054A | TFT7600RKM
FR | AG055A | TFT7600RKM
IT | AG056A | TFT7600RKM
SP | AG057A | TFT7600RKM
DEN | AG058A | TFT7600RKM
NOR | AG059A | TFT7600RKM
SE/FI | AG060A | TFT7600RKM
SWI | AG061A | TFT7600RKM
PORT | AG062A | TFT7600RKM
BEL | AG063A | TFT7600RKM
JPN2 | AG064A | TFT7600RKM
RUS | AG065A |
TFT7600RKM INTL | AG066A |
1U Rack Keyboard & Drawer
(Carbon) | 257054-001
|
NOTE: For additional
information regarding Rack Options, please see the following URL: https://www.hp.com/go/rackandpower. |
|
| HP KVM
Switch Options | IP Console Switch
Box (KVM/IP), 3 x 1 x 16 | |
IP Console Switch Box (KVM/IP),
1 x 1 x 16 | |
Server Console Switch (KVM),
0 x 1 x 8 port | |
Server Console Switch (KVM),
0 x 2 x 16 port | |
PS/2 Interface Adapter, 1 pack |
| PS/2
Interface Adapter, 8 pack | |
USB Interface Adapter, 1 pack |
| Serial
Interface adapter - 1 Pack with power supply |
| NOTE:
Cat5e cables are required to connect Interface Adapters to Console Switches. Cat5e
cables can be found at the following URL: https://www.hp.com/go/kvm.
| |
HP 1x 4 USB/PS2 KVM Switch, TT
| 371301-D71 |
HP 1x 4 USB/PS2 KVM Switch, RM
| 371302-B21 |
HP PS2 KVM Cable with audio,
6', 2-pack | 371730-B21 |
HP USB KVM Cable with audio,
6', 2-pack | 371729-B21 |
NOTE: For additional
information regarding KVM switches, Serial Console servers, rack mount monitors,
keyboards and all related options please see the following URL: https://www.hp.com/go/kvm.
| |
|
HP Serial Console Server Options
|
HP 16 Port Serial Console
Server |
|
HP 48 Port Serial Console
Server |
|
Serial Adapter, RJ45-DB9 DCE Female,
1 Pack |
|
Serial Adapter, RJ45-DB9 DCE Female,
8 Pack |
AF110A
|
NOTE: Cat5e cables
are required to connect Serial Adapters to Serial Console Servers. Additional
Serial Adapters and Cat5e cables can be found at the following URL: https://www.hp.com/go/kvm.
|
|
NOTE: For additional
information regarding KVM switches, Serial Console servers, rack mount monitors,
keyboards and all related options please see the following URL: https://www.hp.com/go/kvm. |
|
|
Service
and Support Offerings (HP Care Pack Services) |
NOTE: The
Service and Support Offerings specifying Microsoft O/S in the description
cover Windows NT, Windows 2000 Server/Advanced Server or Novell NetWare
Operating System. |
|
Hardware Services On-site
Service |
|
4-Hour On-site Service,
5-Day x 13-Hour Coverage, 3 Years, Electronic |
U4713E
|
4-Hour On-site Service,
7-Day x 24-Hour Coverage, 3 Years, Electronic |
U4714E
|
|
Installation & Start-up
Services |
|
Hardware Installation, Electronic |
U4723E
|
Installation & Start-Up
of a ProLiant server and Microsoft or Linux O/S per the Customer Description
and/or Data Sheet. To be delivered on a scheduled basis 8am-5pm, M-F,
excl. HP holidays, Electronic |
U4724E
|
|
Support Plus |
|
Onsite HW support, 8am-9pm,
M-F, 4hr response and Microsoft O/S SW Tech support offsite, onsite
at HP's discretion, 8am-9pm, M-F 2hr response time excl. HP holidays,
Electronic |
U4725E
|
Onsite HW support, 8am-9pm,
M-F, 4hr response and Linux O/S SW Tech support offsite, onsite at
HP's discretion, 8am-9pm, M-F 2hr response time excl. HP holidays,
Electronic |
U4727E
|
|
Support Plus 24 |
|
Onsite HW support 24x7,
4hr response and Microsoft O/S SW Tech support offsite, onsite at
HP's discretion, 24x7 2hr response time incl. HP holidays, Electronic |
U4726E
|
Onsite HW support 24x7,
4hr response and SuSE Linux SW Tech support offsite, onsite at HP's
discretion, 24x7 2hr response time incl. HP holidays, Electronic |
|
6-Hour Call to Repair,
On-site Service 7-Day x 24-Hour Coverage, 3 Years |
|
6-Hour Call to Repair, On-site
Service, 7-Day x 24-Hour Coverage, 3 Years, Electronic |
U4715E
|
|
|
Memory
HP ProLiant DL740 2.2 GHz/2MB |
Standard Memory
2048 MB addressable protected ECC SDRAM DIMM
memory (2 x 256 MB DIMMs x 5 Hot-Plug RAID Memory Cartridges. The 5th cartridge
is populated for redundancy.)
Standard Memory Plus Optional Memory
Up to 51,200 MB of addressable ECC SDRAM DIMM
memory is available with the installation of optional ECC SDRAM DIMM memory
expansion kits.
Standard Memory Replaced with Optional Memory
Up to 65,536 MB of addressable ECC SDRAM DIMM
memory is available with the removal of standard memory and the installation
of optional ECC SDRAM DIMM memory expansion kits.
NOTE:
8 slots per Hot-Plug RAID Memory Cartridge. Memory must be added in banks
of two DIMMs per cartridge across all five (four if running in a non-redundant
mode) Hot-Plug RAID Memory Cartridges. Tables do not represent all possible configurations. |
|
Bank 1
(Standard Memory) |
Bank 2 |
Bank 3 |
Bank 4 |
DL740 G1 Memory
|
Slots
|
|
1
|
2
|
3
|
4 |
5 |
6 |
7 |
8
|
Cartridge 1 (C1)
|
Standard |
256 MB
|
256 MB
|
|
|
|
|
|
|
Optional |
256
MB
|
256 MB
|
2048 MB
|
2048 MB
|
2048 MB
|
2048 MB
|
2048 MB
|
2048 MB
|
Maximum |
2048 MB
|
2048 MB
|
2048 MB
|
2048 MB
|
2048 MB
|
2048 MB
|
2048 MB
|
2048 MB
|
Cartridge 2 (C2)
|
Standard |
256 MB
|
256 MB
|
|
|
|
|
|
|
Optional |
256 MB
|
256 MB
|
2048 MB
|
2048 MB
|
2048 MB
|
2048 MB
|
2048 MB
|
2048 MB
|
Maximum |
2048 MB
|
2048 MB
|
2048 MB
|
2048 MB
|
2048 MB
|
2048 MB
|
2048 MB
|
2048 MB
|
Cartridge
3 (C3) |
Standard |
256
MB
|
256 MB
|
|
|
|
|
|
|
Optional |
256 MB
|
256 MB
|
2048 MB
|
2048 MB
|
2048 MB
|
2048 MB
|
2048 MB
|
2048 MB
|
Maximum |
2048 MB
|
2048 MB
|
2048 MB
|
2048 MB
|
2048 MB
|
2048 MB
|
2048 MB
|
2048 MB
|
Cartridge
4 (C4) |
Standard |
256 MB
|
256 MB
|
|
|
|
|
|
|
Optional |
256 MB
|
256 MB
|
2048 MB
|
2048 MB
|
2048 MB
|
2048 MB
|
2048 MB
|
2048 MB
|
Maximum |
2048 MB
|
2048 MB
|
2048 MB
|
2048 MB
|
2048 MB
|
2048 MB
|
2048 MB
|
2048 MB
|
Cartridge
5 (C5) |
Standard |
256 MB
|
256 MB
|
|
|
|
|
|
|
Optional |
256 MB
|
256 MB
|
2048 MB
|
2048 MB
|
2048 MB
|
2048 MB
|
2048 MB
|
2048 MB
|
Maximum |
2048 MB
|
2048 MB
|
2048 MB
|
2048 MB
|
2048 MB
|
2048 MB
|
2048 MB
|
2048 MB
|
|
Following are memory options available from HP:
|
|
- 2048 MB 133MHz ECC SDRAM Memory Option Kit (1 x 2048 MB)
|
317093-B21
|
- 1024 MB 133MHz ECC SDRAM Memory Option Kit (1 x 1024 MB)
|
236854-B21
|
- 512 MB 133MHz ECC SDRAM Memory Option Kit (1 x 512 MB)
|
236853-B21
|
- 256 MB 133MHz ECC SDRAM Memory Option Kit (1 x 256 MB)
|
236852-B21
|
HP ProLiant DL740 3.0 GHz/4MB, 2.7 GHz/2MB |
Standard Memory
4096 MB addressable protected ECC SDRAM DIMM
memory (2 x 512 MB DIMMs x 5 Hot-Plug Memory Cartridges. The 5th cartridge
is populated for redundancy.)
Standard Memory Plus Optional Memory
Up to 53,248 MB of SDRAM DIMM memory is available
with the installation of optional SDRAM DIMM memory expansion kits.
Standard Memory Replaced with Optional Memory
Up to 65,536 MB of SDRAM DIMM memory is available
with the removal of standard memory and the installation of optional SDRAM
DIMM memory expansion kits.
NOTE:
8 slots per Hot-Plug RAID Memory Cartridge. Memory must be added in banks
of two DIMMs per cartridge across all five (four if running in a non-redundant
mode) Hot-Plug RAID Memory Cartridges. Tables do not represent all possible configurations. |
|
Bank 1
(Standard Memory) |
Bank 2 |
Bank 3 |
Bank 4 |
DL740 G1 Memory
|
Slots
|
|
1
|
2
|
3
|
4 |
5 |
6 |
7 |
8
|
Cartridge 1 (C1)
|
Standard |
512 MB
|
512 MB
|
|
|
|
|
|
|
Optional |
512 MB
|
512 MB
|
2048 MB
|
2048 MB
|
2048 MB
|
2048 MB
|
2048 MB
|
2048 MB
|
Maximum |
2048 MB
|
2048 MB
|
2048 MB
|
2048 MB
|
2048 MB
|
2048 MB
|
2048 MB
|
2048 MB
|
Cartridge 2 (C2)
|
Standard |
512 MB
|
512 MB
|
|
|
|
|
|
|
Optional |
512 MB
|
512 MB
|
2048 MB
|
2048 MB
|
2048 MB
|
2048 MB
|
2048 MB
|
2048 MB
|
Maximum |
2048 MB
|
2048 MB
|
2048 MB
|
2048 MB
|
2048 MB
|
2048 MB
|
2048 MB
|
2048 MB
|
Cartridge
3 (C3) |
Standard |
512 MB
|
512 MB
|
|
|
|
|
|
|
Optional |
512 MB
|
512 MB
|
2048 MB
|
2048 MB
|
2048 MB
|
2048 MB
|
2048 MB
|
2048 MB
|
Maximum |
2048 MB
|
2048 MB
|
2048 MB
|
2048 MB
|
2048 MB
|
2048 MB
|
2048 MB
|
2048 MB
|
Cartridge
4 (C4) |
Standard |
512 MB
|
512 MB
|
|
|
|
|
|
|
Optional |
512 MB
|
512 MB
|
2048 MB
|
2048 MB
|
2048 MB
|
2048 MB
|
2048 MB
|
2048 MB
|
Maximum |
2048 MB
|
2048 MB
|
2048 MB
|
2048 MB
|
2048 MB
|
2048 MB
|
2048 MB
|
2048 MB
|
Cartridge
5 (C5) |
Standard |
512 MB
|
512 MB
|
|
|
|
|
|
|
Optional |
512 MB
|
512 MB
|
2048 MB
|
2048 MB
|
2048 MB
|
2048 MB
|
2048 MB
|
2048 MB
|
Maximum |
2048 MB
|
2048 MB
|
2048 MB
|
2048 MB
|
2048 MB
|
2048 MB
|
2048 MB
|
2048 MB
|
|
Following are memory options available from HP:
|
|
- 2048 MB 133MHz ECC SDRAM Memory Option Kit (1 x 2048 MB)
|
317093-B21
|
- 1024 MB 133MHz ECC SDRAM Memory Option Kit (1 x 1024 MB)
|
236854-B21
|
- 512 MB 133MHz ECC SDRAM Memory Option Kit (1 x 512 MB)
|
236853-B21
|
- 256 MB 133MHz ECC SDRAM Memory Option Kit (1 x 256 MB)
|
236852-B21
|
Storage

|
0-3 |
Ultra3 Hot Plug Drive Bays |
A |
1.44-MB Diskette Drive
| B |
Slimline CD/DVD-ROM Drive, Hot Pluggable, in Universal Media Bay
|
C | Universal
Media Bay Eject Button |
|
Drive Support
|
|
|
Quantity
Supported
|
Position
Supported
|
Controller
|
Integrated Media |
|
|
|
|
Integrated 1.44-MB
Diskette Drive
|
Up to 1
|
A
|
Integrated
|
|
Slimline CD/DVD-ROM
Drive (8X/24X)
|
Up to 1
|
B
|
Integrated IDE
|
|
DL740 G1 Hard Drives | | Ultra320
Hot Pluggable Drives |
| Quantity Supported |
Position Supported |
Controller
|
|
300GB U320 10K
146.8GB U320 10K
72.8GB U320 10K
146.8GB U320 15K
72.8GB U320 15K
36.4GB U320 15K
|
Up to 4 |
0-3 |
Integrated Smart
Array 5i Controller
Smart Array 641 Controller
Smart Array 642 Controller
64-Bit/133MHz Dual Channel Ultra320 SCSI Adapter |
| | NOTE:
All U320 Universal Hard Drives are backward compatible to U2 or U3 speeds.
U320 drives require an optional U320 Smart Array Controller or U320 SCSI HBA to
support U320 transfer rates. |
|
External Storage
|
|
Quantity
Supported
|
Position
Supported
|
Host Controller or Adapter
|
|
Modular Smart Array 20 |
1 per SCSI VHDCI
connector
|
External |
Smart Array 6402/128 Controller
Smart Array 6404/256 Controller |
|
Modular Smart Array 30 Family
|
Up to 13
|
External
|
Smart Array 6402/128 Controller
Smart Array 6404/256 Controller
Smart Array 642 Controller
64-Bit/133MHz Dual Channel Ultra320 SCSI Adapter
64-Bit/66MHz Dual Channel Wide Ultra3 SCSI Adapter, Alternate OS |
|
Modular Smart Array 500 G2 System
|
1 |
External |
Please see the Modular Smart Array
500 QuickSpecs for the latest list of supported HBAs: https://www.hp.com/go/msa500
|
|
Modular Smart Array 1000 |
Please see
the Modular Smart Array 1000 QuickSpecs below to determine configuration
requirements |
External |
Please see the Modular Smart Array
1000 QuickSpecs (URL below) for the latest list of supported HBAs |
|
Modular Smart Array 1500 cs |
Please see
the Modular Smart Array 1500 cs QuickSpecs below to determine configuration
requirements |
External |
Please see the Modular Smart Array
1500 cs QuickSpecs (URL below) for the latest list of supported HBAs |
|
Modular Smart Array 1000: https://h18000.www1.hp.com/products/quickspecs/11033_na/11033_na.html
Modular Smart Array 1500 cs: https://www.hp.com/go/MSA1500cs
|
|
Maximum Storage Capacity - (SCSI Attached)
|
|
Internal
|
1.20TB (4 x 300GB Ultra320 Drives)
|
|
External |
100.80TB hot plug
SCSI storage (24 x (14 x 300GB Ultra320 Drives)) |
|
Total |
102.00TB
|
|
Tape
Drives, Tape Autoloaders, & Tape Libraries |
NOTE: For an up-to-date listing of the latest
O/S Support details for each of the Tape Drives listed below, please see the following:
https://h18000.www1.hp.com/products/quickspecs/north_america/10233.html
NOTE: For an up-to-date listing of the latest
O/S Support details for each of the Tape Autoloaders & Tape Libraries listed
below, please see the following: https://h18000.www1.hp.com/products/quickspecs/north_america/10809.html
NOTE: For complete listing of tape drive
offerings see https://www.hp.com/products1/storage/compatibility/tapebackup/ISS/index.html
For details on connecting tape
drives to this server, see the following: |
| Quantity Supported |
Position Supported |
Controller | | HP
StorageWorks Tape Drives, Hot Plug DAT 40 Hot Plug DAT 72 Hot Plug |
1 | 0-3 | Smart
Array 5i Controller (integrated on system board) 64-Bit/133MHz Dual Channel
Ultra320 SCSI Adapter 64-Bit/133-MHz Single Channel Ultra320 SCSI HBA G2
64-Bit/66-MHz Dual Channel Wide Ultra3 SCSI Adapter, Alternate OS |
|
| | |
HP StorageWorks Tape Drives,
USB External DAT 24 USB DAT 40 USB DAT 72 USB |
1 per USB port |
External | USB
port | |
| | |
HP StorageWorks Tape Drives,
External Ultrium 232 Ultrium 448 Ultrium 460 DAT 40 DAT
72 DLT VS80 DLT VS160 SDLT 320 |
Up to 2 |
External | 64-Bit/133MHz
Dual Channel Ultra320 SCSI Adapter 64-Bit/133-MHz Single Channel Ultra320
SCSI HBA G2 64-Bit/66-MHz Dual Channel Wide Ultra3 SCSI Adapter, Alternate
OS | |
| | |
HP StorageWorks Tape Drives,
External Ultrium 960 SDLT 600 |
1 per SCSI Channel |
External | 64-Bit/133MHz
Dual Channel Ultra320 SCSI Adapter 64-Bit/133-MHz Single Channel Ultra320
SCSI HBA G2 64-Bit/66-MHz Dual Channel Wide Ultra3 SCSI Adapter, Alternate
OS | |
| | |
HP StorageWorks Autoloaders,
External DAT 72x6 Tape Autoloader 1/8 Tape Autoloader |
1 autoloader per SCSI channel |
External | 64-Bit/133MHz
Dual Channel Ultra320 SCSI Adapter 64-Bit/133-MHz Single Channel Ultra320
SCSI HBA G2 64-Bit/66-MHz Dual Channel Wide Ultra3 SCSI Adapter, Alternate
OS | |
| | |
HP StorageWorks Rack-mount
Tape Drive Enclosures 1U Rack-Mount Kit 3U Rack-Mount Kit 5U Rack-Mount
Kit | 1 per
SCSI channel | External | 64-Bit/133MHz
Dual Channel Ultra320 SCSI Adapter 64-Bit/133-MHz Single Channel Ultra320
SCSI HBA G2 64-Bit/66-MHz Dual Channel Wide Ultra3 SCSI Adapter, Alternate
OS | |
| | |
HP StorageWorks Tape Libraries,
External MSL2024 (Ultrium 448 and 960-based) MSL4048 (Ultrium 448 and
960-based) MSL6000 (Ultrium 960 and 460-based) MSL6000 (SDLT 600-based)
MSL5026S2 (SDLT 320-based) MSL5052S2 (SDLT 320-based)
|
Please reference the MSL Tape Library QuickSpecs to determine
configuration requirements |
External | Please
consult the EBS connectivity matrix at https://www.hp.com/go/ebs
for detailed connectivity information. |
Quickspecs
System Unit | Dimensions
(HxWxD) | 7.00
x 17.5 x 28.7 in (17.78 x 44.45 x 72.90 cm) |
Weight No hard drives installed, two power supplies |
105 lb (47.63 kg) |
Input Requirements (per power supply) | Rated
Input Voltage | 115 to 120 VAC/200
to 240 VAC (lowline/highline) | Rated
Input Frequency | 47 to 63 Hz (lowline/highline) |
Input Power | 1060W/1440W
(lowline/highline) | Rated
Input Current | 10A at 115 VAC/8A
at 200 VAC (lowline/highline) |
BTU Rating (Maximum output) (NOTE
that the maximum heat output by the server is equal to the electrical power input.)
| 1555 Watts [5309
BTU/hr]
(System is configured to draw maximum power)
Use of 110 volt power sources is not recommended. |
Please refer to
the Power Calculator at: https://h30099.www3.hp.com/configurator/ powercalcs.asp. |
Power Supply Output
Power (per power supply) | Rated
Steady-State Power | 800W/1100W
(lowline/highline) | Maximum
Peak Power | 800W/1100W (lowline/highline) |
Temperature Range
| Operating | 50°
to 95° F at sea level, altitude de-rating of 1.8° F per 1,000 ft to 10,000
ft (10° to 35° C at sea level, altitude de-rating of 1° C per 300
m to 3,000 m). Maximum rate of change is 18° F/Hr (10° C/Hr) |
Non-operating |
-22° to 140 ° F (-30°
to 60° C). Maximum rate of change is 36°F/Hr (20°C/Hr) |
Shipping | 5%
to 95% relative humidity, non-condensing |
Relative Humidity (non-condensing) | Operating | 10
to 90% relative humidity, 82.4° F (28° C) maximum wet bulb temperature,
non-condensing | Non-operating | 5
to 95% relative humidity, 101.7° F (38.7° C) maximum wet bulb temperature,
non-condensing | Maximum
Wet Bulb Temperature | 101.7°
F(38.7° C) | |
Acoustic Noise | Idle
(Fixed Disk Drives Spinning) | |
L WAd (BELS) | 7.6 |
L pAm (dBA) | 59 |
|
Power Supply | 1100/800W,
Hot Plug Redundant (2 standard) | One
Redundant Power Supply (optimized to provide full redundancy at 220 volts) |
Input Specifications | Normal
Line Voltage | 115 to 127 VAC/200
to 240 VAC | Range Input
Line | 115 to 132 VAC/180 to 265
VAC | Frequency Range | 47
to 63 Hz | Power Factor | 0.95 |
Input Current | 10
A at 115 VAC/8 A at 200 VAC | Inrush
Current | 100 A | Holdup
Time | 21 ms from zero crossing
at 120 VAC | General
Specifications | Full
Output Rating | To 104° F (40°
C) and 5,000 ft (1524 m) | To
89.6° F (32° C) and 10,000 ft (3,048 m) (derate linearly) |
Minimum Load | 1
A on + 5 V output; 2 A on + 12 V output; 1 A on + 3.3 V output |
Ambient Temperature
Range | Operating | 41°
to 109° F (5° to 43° C) (End use system maximum ambient of 35°C,
plus a maximum of 8° C due to rack effect) | Non-operating | -40°
to 185° F (-40° 85° C) | Dielectric
Voltage Withstand | Input to
Output | 3,000 VAC/min |
Input to Ground | 1,500
VAC/min | Input Transient
Susceptibility | Common and
Differential Mode (superimposed on AC line) | ±
1kV line on AC power port for 1 minute; ± 0.5kV on signal/control lines |
|
Slimline CD/DVD-ROM Combo Drive (8X/24X) (Multibay)
|
Shipping Dimensions |
13.88 x 11.38 x 9.25
in (35.26 x 28.91 x 23.50 cm) |
Shipping Weight
|
5 lb (2.27 kg) |
|
Disk |
Applicable Disk
|
DVD-ROM
|
|
|
DVD-R (Read Only)
|
|
|
2.6 GB/side DVD-RAM (Read Only)
|
|
|
5.2 GB/side DVD-RAM (Read Only)
|
|
|
CD-ROM Mode-1 data disc
|
|
|
CD-ROM Mode-2 data disc |
|
|
CD Audio disc |
|
|
CD-Extra |
|
|
CD-R |
|
|
CD Text |
|
|
PhotoCD |
|
|
CD-I (mode 2) |
|
|
CD-I Ready |
|
|
CD-Bridge |
|
Capacity
|
DVD-ROM
|
DVD-SL |
4.7 GB/side |
|
|
|
DVD-DL |
8.5 GB/side |
|
|
|
Double Sided |
9.40 GB/side |
|
|
DVD-R |
|
3.95 GB/side |
|
|
DVD-RAM |
|
2.6 GB/side and 5.2 GB/ |
|
|
CD-ROM |
Mode-1 |
650 MB (550 MB) |
|
|
|
Mode-2 |
742 MB (640 MB) |
|
Block Size |
DVD |
|
2,048 bytes |
|
|
CD |
|
2,352 (Mode-0) |
|
|
|
|
2352, 2340, 2336, 2048 bytes
(Mode-1) |
|
|
|
|
2352, 2340, 2336, 2048 bytes
(Mode-2) |
|
Diameter
|
120 mm, 80 mm (with adapter at vertical mounting mode)
|
Loading Mechanism |
Tray type
|
|
Interface |
EIDE (ATAPI)
|
|
Access Times (typical) |
Random
|
DVD-ROM < 120 ms, CD-ROM < 110 ms
|
|
Full-Stroke
|
DVD-ROM < 240 ms, CD-ROM < 160 ms
|
Audio Output Level (typical)
|
Line-out
|
CD 0.7 Vrms at 47 Kohms Load
|
Data Transfer Rate (sustained)
|
DVD-ROM
|
Single Layer
|
10.8 MB/sec. Max. |
DVD-RAM |
2.77 MB/sec. Max |
|
CD-ROM
|
7.2 MB/sec. Max.
|
Cache Buffer
|
2 MB
|
|
Spin-up Time (typical)
|
less than 10 seconds
|
|
MTBF |
120,000 Power On Hours (POH)
|
|
Ambient Temperature
|
Operating
|
-22° to 140° F (-30° to 60° C)
|
Relative Humidity |
Operating
|
10% to 80%
|
|
Storage/Transportation
|
5% to 95% |
Dimensions
|
(HxWxD, maximum)
|
0.5 x 5.04 x 5.1 in (12.7x128x129.4 mm)
|
Option Kit Contents |
DVD-ROM drive with installation
guide, warranty card, registration card |
|
Smart Array 5i Controller
(integrated on system board)
|
Protocol |
Wide Ultra3 SCSI |
Processor |
32-bit RISC |
XOR engine |
Hardware RAID |
Electrical interface |
Low Voltage Differential (LVD) |
Simultaneous Drive Transfer Channels |
2 |
Channel Transfer Rate |
320 MB/s total; 160 MB/s per channel |
SCSI Port Connectors |
One external and one internal
SCSI port |
Memory |
32 MB of DRAM used for code, transfer
buffers, and non-battery-backed read cache |
Peak transfer rate |
160 MB/s |
Logical Drives Supported |
32 |
Software Upgradeable Firmware |
Yes |
RAID Support |
RAID 5 (Distributed Data Guarding
RAID 1+0 (Striping and Mirroring)
RAID 1 (Mirroring)
RAID 0 (Stripping) |
Disk Drive and Enclosure Protocol
Support |
Ultra2 and Ultra3 |
|
|
|
|
Two NC7781 PCI-X Gigabit NICs
(embedded)
|
Network Interface
|
10/100/1000-T
|
Compatibility
|
IEEE 802.3 10Base-T
IEEE 802.3ab 1000Base-T
IEEE 802.3u 100Base-TX
|
Data Transfer Method
|
64-bit/66MHz PCI-X
|
Network
Transfer Rate |
10Base-T (Half-Duplex),
10Base-2
|
10 Mb/s
|
10Base-T (Full-Duplex)
|
20 Mb/s
|
100Base-TX (Half-Duplex)
|
100 Mb/s
|
100Base-TX (Full-Duplex)
|
200 Mb/s
|
1000Base-T (Half and Full- Duplex) |
2000 Mb/s |
Connector
|
RJ-45
|
Cable Support
|
10Base-T
|
Categories 3, 4 or 5 UTP
up to 328 ft (100 m)
|
100Base-TX
|
Category 5 UTP up to 328 ft (100 m)
|
|
|
|
|
|
|