3. Four
Hot-Plug (shown) or Four Non hot-plug (not shown) Drive Bays
7. 350W Power Supply
4. Four Expansion Slots (Two
PCI-X, One PCI, and One PCI Express)
At A Glance
Supports a single 3.0 GHz,
3.20 GHz, or 3.40 GHz Intel® Pentium® 4 processor with 1MB or 2MB cache
size or a single 2.8 GHz Intel Celeron processor with 256KB cache size.
Intel® Pentium® 4 processors include support for
Hyper-Threading
HP's new HP Systems Insight
Manager (HP SIM) helps maximize system uptime and performance and reduce system
maintenance costs by providing proactive notification of problems before those
problems result in unplanned downtime or reduced productivity. HP SIM are both
easy to set up work with the Insight Management Agents, integrated Lights-Out
and Remote Insight Lights-Out Edition, and Version Control Agents to deliver robust
fault, configuration, and asset management as well as remote administration. With
HP SIM customers will also be able to take advantage of role-based security; the
ability to manage ProLiant, Integrity, and HP 9000 systems; and plug-ins for storage,
client, printer, and power management as well as server rapid deployment, performance
management, and workload management. For more details on HP SIM visit http://www.hp.com/go/hpsim.
Management Agents
The
Management Agents form the foundation for HP's Intelligent Manageability strategy.
They provide direct, browser-based access to in-depth instrumentation built into
HP servers, workstations, desktops, and portables, and send alerts to HP Systems
Insight Manager and other enterprise management applications in case of subsystem
or environmental failures. For additional information about the Management Agents
and other management products from HP, please visit the management Web site at
http://www.hp.com/servers/manage.
SmartStart
SmartStart
is a tool that simplifies server setup, providing a rapid way to deploy reliable
and consistent server configurations. For more information, please visit the SmartStart
Web site at http://www.hp.com/servers/manage. SmartStart version supported (minimum): SmartStart
7.20.
Subscriber's
Choice
Subscriber's Choice Driver
and Support Alerts/Notifications is a web-based email subscription service that
provides automatic delivery of software and driver change notifications for ProLiant
products. Sign up at http://www.hp.com/go/subscriberschoice
and customize your profile to receive various new alerts as they become available,
on a weekly or monthly basis.
ROMPaq,
support software, and configuration utilities
The
latest software, drivers, and firmware fully optimized and tested for your ProLiant
server and options available in SmartStart or downloadable from Software and Drivers
download pages, linked from the SmartStart website at http://www.hp.com/servers/smartstart.
Survey Utility and diagnostics
utilities
The most advanced
configuration analysis, reporting and troubleshooting utilities used by HP and
at your fingertips, available in SmartStart.
Optional ProLiant Essentials Value
Packs
Optional software offerings
that selectively extend the functionality of an Adaptive Infrastructure to address
specific business problems and needs:
Rapid Deployment Pack - an automated
solution for multi-server deployment and provisioning, enabling companies to quickly
and easily adapt to changing business demands.
Workload Management Pack
- provides easier management of complex environments, improving overall server
utilization and enabling Microsoft® Windows® 2000 customers for the first
time to confidently deploy multiple applications on a single multiprocessor ProLiant
Server.
Performance Management Pack - a performance management solution
that identifies and explains hardware performance bottlenecks on ProLiant servers
and attached options enabling users to better utilize their valuable resources.
Intelligent
Networking Pack - detects and analyzes network bottlenecks or broken network linkages
and steers traffic to the optimum route based on network conditions, plus it provides
an extra layer of protection. The virus throttle feature of the solution slows
the propagation of fast spreading virus
Vulnerability and Patch Management
Pack - identifies and remediates software security vulnerabilities due to missing
patches as well operating system configurations that can be exploited by viruses,
worms, and other blended threats
Virtual Machine Management Pack - provides
central management and control of virtual machines from Microsoft and VMware.
Integrated approach provides the ability to manage both physical and virtual resources
from a single management console.
Server Migration Pack - The Server
Migration Pack automates the manual processes required for migrating servers between
physical or virtual platforms (P2V, V2P, and V2V).
NOTE:
Flexible and volume quantity license kits are available for ProLiant Essentials
Value Packs. Refer to http://www.hp.com/servers/proliantessentials
or the various ProLiant Essentials Value Pack product QuickSpecs for more information.
ACPI V1.0b Compliant
PCI 2.2 Compliant
PCI-X 1.0 Compliant
PCI-Express 1.0a Compliant
PXE Support
WOL Support
Microsoft Logo certifications
Novell Logo certifications
USB2.0
Manageability
HP Systems Insight Manager
Online ROM Flash Utility
Automatic Server Recovery-2 (ASR-2)
Drive Parameter Tracking (with Smart Array Controller)
Dynamic Sector Repairing (with Smart Array Controller)
Pre-Failure Warranty (covers processors, memory and SCSI hard drives)
BIOS Serial Console
Security
Power-on password
Setup password
Diskette boot control
Power switch security
Intruder Alert Message
Server Power Cords
All models ship with one 6'
standard low-line country specific power cord.
Microsoft Windows Server 2003
(Standard & Web Edition)
Microsoft Small Business Server 2003
Microsoft Windows 2000 Server
Novell NetWare
Linux (Red Hat, SuSE, and UnitedLinux)
VMware Virtualization Software
Rack 10000 series Cabinets
The increasing power of new high-performance processor technology requires
increased cooling efficiency for rack-mounted servers. The 10000 Series
Racks provide enhanced airflow for maximum cooling, allowing these racks
to be fully loaded with servers using the latest processors.
CAUTION: If a third-party rack
is used, observe the following additional requirements to ensure adequate
airflow and to prevent damage to the equipment:
Front and rear doors: If your 42U
server rack includes closing front and rear doors, you must allow
830 square inches (5,350 sq cm) of hole evenly distributed from top
to bottom to permit adequate airflow (equivalent to the required 64
percent open area for ventilation).
Side: The clearance between the
installed rack component and the side panels of the rack must be a
minimum of 2.75 inches (7 cm).
CAUTION: Always use blanking panels
to fill all remaining empty front panel U-spaces in the rack. This arrangement
ensures proper airflow. Using a rack without blanking panels results in
improper cooling that can lead to thermal damage.
NOTE:For additional information, refer to the Setup and Installation
Guide or the Documentation CD provided with the server, or to the server documentation
located in the Support section at the following URL: http://h18000.www1.hp.com/products/servers/ProLiantdl760/index.html.
Factory Express Portfolio for
Servers and Storage
HP Factory Express offers configuration,
customization, integration and deployment services for HP servers and storage
products. Customers can choose how their factory solutions are built, tested,
integrated, shipped and deployed.
Factory Express offers service packages for simple
configuration, racking, installation, complex configuration and design services as well
as individual factory services, such as image loading, asset tagging, and
custom packaging. HP products supported through Factory Express include a wide
array of servers and storage: HP Integrity, HP ProLiant, HP ProLiant
Server Blades, HP BladeSystem, HP 9000 servers as well as the MSA1000,
VA7xxx, EVA, XP, rackable tape libraries and configurable network switches.
For more information on Factory Express services for your specific server
model please contact your sales representative or go to http://www.hp.com/go/factory-express.
The
HP Smart Buy program offers mainstream business solutions at competitive
prices with excellent availability and superior HP quality. It offers a
wide range of industry-leading HP products at compelling prices, allowing
you to receive richer configurations with additional options.
This product is covered by a global limited warranty and supported by
HP Services and a worldwide network of resellers and service providers.
Hardware diagnostic support and repair is available for three years from
date of purchase. Support for software and initial setup is available
for 90 days from date of purchase. Additional support may be covered under
the warranty or available for an additional fee. Enhancements to warranty
services are available through HP Care Pack services or customized service
agreements.
NOTE:Limited
warranty includes 1 year parts, 1 year labor, 1 year on-site support.
Care Pack services provide a range of life cycle support options that
let you choose the service levels that meet your business requirements,
from basic to mission-critical.
A full range of HP Care Pack hardware and software services are
available including:
Installation and start up
Education courses
Extended onsite hardware coverage hours from
same business day 13 hours, 5 day to 24 hours, 7 days call window with
options including 4-hour response or 6-hour Call To Repair
Comprehensive range of software technical
support for Microsoft, Linux, ProLiant Essentials and VMWare-based IT
solutions helping to deliver high level of application availability.
Response times range from 30 mins for critical problems to 2 hours.
System Management, Performance Services and Mission Critical Support
Solution
HP Care Pack services include coverage for the HP branded hardware options
qualified for the server, purchased at the same time or afterward, internal
to the enclosure, as well as 22" and smaller external monitors and
tower UPS options up to 3kVA; these items will be covered at the same
service level and for the same coverage period as the server. Coverage
of UPS Battery is not included, standard warranty terms & conditions
apply. For servers or storage systems installed within a rack, service
also covers all HP qualified rack options installed within the same rack.
NOTE: For more
information on HP Care Pack services, contact any of our worldwide sales
offices or resellers or visit our worldwide Web site on the internet at:
http://www.hp.com/hps/carepack NOTE: For more complete information on HP Services offerings, customers
and resellers, please visit us at: http://www.hp.com/hps NOTE: Additional information regarding worldwide limited warranty
and technical support is available at: http://h18004.www1.hp.com/products/servers/platforms/warranty/index.html
None ship standard (up to 4
hot plug SATA or SAS drives supported) NOTE: See the "Storage" section of these
QuickSpecs for information on controllers and cables required to support
SATA and
SAS
drive configurations
Internal Storage
2.0 TB maximum hot plug SATA
(with optional hard drives)
Optical Drive
48x IDE (ATAPI) CD-ROM Drive
Diskette Drive
None ship standard (Optional
1.44 MB Diskette Drive)
Form Factor
Tower (5U) (Tower to Rack Enabling
Option Kit available)
ML310T02 3.4/800-1M
NHP-SCSI
378247-002
Processor(s)
(1) Intel Pentium 3.40 GHz (standard)
Cache Memory
1MB Level 2 cache
Memory
512 MB (Standard) to 4 GB (Maximum)
of Advanced ECC PC3200 DDR SDRAM DIMM Memory
320 GB maximum NHP SATA (with
optional drives) NOTE: See the "Storage"
section of these QuickSpecs for information on controllers and cables required
to support SATA drive configurations
Optical Drive
48x IDE (ATAPI) CD-ROM Drive
Diskette Drive
None ship standard (Optional
1.44 MB Diskette Drive)
Form Factor
Tower (5U) (Tower to Rack Enabling
Option Kit available)
ML310T02 3.2/800-2M
HP SCSI
381839-001
Processor(s)
(1) Intel Pentium 3.20 GHz (standard)
Cache Memory
2MB Level 2 cache
Memory
512 MB (Standard) to 4 GB (Maximum)
of Advanced ECC PC3200 DDR SDRAM DIMM Memory
None ship standard (up to 4
hot plug SATA or SAS drives supported) NOTE: See the "Storage" section of these
QuickSpecs for information on controllers and cables required to support
SATA and
SAS
drive configurations
Internal Storage
2.0 TB maximum hot plug SATA
(with optional hard drives)
Optical Drive
48x IDE (ATAPI) CD-ROM Drive
Diskette Drive
None ship standard (Optional
1.44 MB Diskette Drive)
Form Factor
Tower (5U) (Tower to Rack Enabling
Option Kit available)
ML310T02 3.2/800-1M
HP-SCSI
376871-001
Processor(s)
(1) Intel Pentium 3.20 GHz (standard)
Cache Memory
1MB Level 2 cache
Memory
512 MB (Standard) to 4 GB (Maximum)
of Advanced ECC PC3200 DDR SDRAM DIMM Memory
None ship standard (up to 4
hot plug SATA or SAS drives) NOTE: See the "Storage" section of these
QuickSpecs for information on controllers and cables required to support
SATA and
SAS
drive configurations
Internal Storage
2.0 TB maximum hot plug SATA
(with optional hard drives)
Optical Drive
48x IDE (ATAPI) CD-ROM Drive
Diskette Drive
None ship standard (Optional
1.44 MB Diskette Drive)
Form Factor
Tower (5U) (Tower to Rack Enabling
Option Kit available)
ML310T02 3.2/800-1M
NHP SCSI
378279-002
Processor(s)
(1) Intel Pentium 3.20 GHz (standard)
Cache Memory
1MB Level 2 cache
Memory
512 MB (Standard) to 4 GB (Maximum)
of Advanced ECC PC3200 DDR SDRAM DIMM Memory
320 GB maximum non hot plug
SATA (with optional hard drives) NOTE: See the "Storage"
section of these QuickSpecs for information on controllers and cables required
to support SATA drive configurations
Optical Drive
48x IDE (ATAPI) CD-ROM Drive
Diskette Drive
None ship standard (Optional
1.44 MB Diskette Drive)
Form Factor
Tower (5U) (Tower to Rack Enabling
Option Kit available)
Configuration Information - Factory Integrated Models
NOTE:
All configure-to-order servers must start with a CTO Chassis. Use the following
section to order a server customized to your requirements with options integrated
at the factory. The options you select in steps 2 and 3 will be integrated
with the base configuration you select in step 1. Additional options selected
in Step 4 will also be integrated when applicable. NOTE: Standard models of this product offering (see previous section
of this document) do not support HP Factory Express Server Configuration
Level 1.
ProLiant Essentials
Intelligent Networking Pack, Single Server License NOTE: For use with a single server.
Contains one license with a unique license activation key and documentation.
ProLiant Essentials
Performance Management Pack, Single-Server License NOTE: For use with a single server.
Contains one license with a unique license activation key, HP Management
CD and documentation. NOTE: The most recent version of the software can always be downloaded
at http://www.hp.com/products/pmp.
ProLiant Essentials
Virtual Machine Management Pack, Single-Server License NOTE: For use with a single server.
Contains one license with a unique license activation key and documentation.
372214-B21
ProLiant
Essentials Server Migration Pack, Single-Migration License NOTE: Contains one license, enabling 1 server migration, with a unique
license activation key and documentation. NOTE: This license allows 1 server to be migrated from a physical
server to a virtual machine. Or this license can be used to migrate a virtual
machine from one virtualization layer i.e. VMware GSX to a different virtualization
layer such as VMware ESX or Microsoft Virtual Server 2005.
ProLiant Essentials
Vulnerability and Patch Management Pack
ProLiant Essentials
Vulnerability and Patch Management Pack, Single-Server License NOTE: For use with a single server.
Contains one license with a unique license activation key and documentation.
NOTE:
Flexible and volume quantity license kits are available for ProLiant Essentials
Value Packs. Refer to http://www.hp.com/servers/proliantessentials
or the various ProLiant Essentials Value Pack product QuickSpecs for more
information. NOTE: For more information regarding ProLiant Essentials Software,
please see the following URL: http://www.hp.com/servers/proliantessentials.
CD-RW/DVD-ROM Combo Drive Option
Kit NOTE: The DVD-ROM drive is supported
in the CD-ROM bay and in the removable media bay. If placed in the removable
media bay, it requires the 2-Device IDE cable (PN 305381-B21).
NOTE: This cable
is required when the HP 6-port SATA RAID controller is installed on hot
plug SATA/SAS models of the ML310 G2. See the "Storage" section of these
QuickSpecs for information on controllers and cables required to support
SATA drive configurations.
HP 2-port SATA Cable
379093-B21
NOTE: This cable
is required when the HP 6-port SATA RAID controller is installed on non-hot
plug SATA/SAS models of the ML310 G2. See the "Storage" section of these
QuickSpecs for information on controllers and cables required to support
SATA drive configurations.
Storage Controllers
SCSI
Controllers
NOTE: The following
Storage Controllers are qualified for SCSI drives only. They do not support SATA
or SAS Drives.
NOTE: Please
see the following Controller QuickSpecs for Technical Specifications such as PCI
Bus, PCI Peak Data Transfer Rate, SCSI Protocols supported, SCSI Peak Data Transfer
Rate, Channels, SCSI Ports, Drives supported, Cache, RAID support, and additional
information: http://h18000.www1.hp.com/products/quickspecs/12247_na/12247_na.HTML (Smart Array P600 Controller)
HP 6-port SATA RAID Controller NOTE: See the "Storage" section of these
QuickSpecs for information on controllers and cables required to support SATA
drive configurations
NOTE:
NC61XX, NC71XX, NC77XX, or NC1020 network adapter (NIC) can be used for redundancy
with the embedded NC7761 NIC. When either the embedded NC7761 or the NC1020 is
teamed with other HP NICs, Jumbo Frames and LSO features are automatically disabled.
HP StorageWorks 1U Rack-Mount
Kit NOTE: The 1U Rack-mount Kit can
support up to (2) half-height tape drives and compatible with multiple Single-Ended
and LVD SCSI tape drives including the DAT 24, DAT 40, DAT 72, DLT VS80, DLT VS160,
Ultrium 215, Ultrium 232 and Ultrium 448 tape drives.
NOTE: Please
reference the 1/8 Tape Autoloader QuickSpecs at http://www.hp.com/go/automation
for additional information needed to create a complete solution; reference current
compatibility information at http://www.hp.com/go/ebs
Tape Libraries
HP
StorageWorks MSL2024 Tape Library
HP
StorageWorks MSL2024 1 Ultrium 960 Drive Library
NOTE: Please reference
the MSL2024 and MSL6000 Tape Library QuickSpecs at http://www.hp.com/go/automation
for additional information needed to create a complete solution; reference
current compatibility information at http://www.hp.com/go/ebs.
NOTE: The UPS
R12000 XR has a hardwired input and output connection.
Modular PDUs 1U/0U (Up to 32 outlets) NOTE: 1U/0U mounting brackets
shipped with
the unit (optimized for 10000 and 9000 series racks).
HP Modular Power Distribution
Units (mPDU), Low Volt Model, 24A (100-127 VAC) NOTE: This mPDU ( 252663-D71) may
also be used to connect the low volt model of the UPS R3000 XR.
HP Modular Power Distribution
Units (mPDU), High Volt Model, 16A (200-240 VAC) NOTE: This PDU has a detachable input
power cord and allows for adaptability to country specific power requirements.
This model may also be used with the high volt UPSs R3000 XR and R6000.
Need to order cable PN 340653-001.
NOTE: Support
for racks with round or square mounting holes (including all Compaq
and HP Rack System /E and HP Systems), with an adjustment range of
24" 36".
Other
Internal to External SCSI Cable
Option Kit (HD68)
159547-B22
Internal to External SCSI Cable
Option Kit (VHDCI)
333370-B21
Telco Rack Option Kit
251243-B21
NOTE: Support
for all 2-post Telco racks requires the use of the standard four post rack
kit and an additional option kit from HP.
NOTE:
-B21 (pallet) used to ship empty racks shipped on a truck -B22 (shock
pallet) used to ship racks with equipment installed (by custom systems, VARs and
Channels) -B23 (crated) used for air shipments of empty racks
NOTE: Cat5e cables
are required to connect Interface Adapters to Console Switches. Cat5e cables
can be found at the following URL: http://www.hp.com/go/kvm.
HP 1x 4 USB/PS2 KVM Switch, TT
371301-D71
HP PS2 KVM Cable with audio, 6',
2-pack
371730-B21
HP USB KVM Cable with audio, 6',
2-pack
371729-B21
NOTE: For additional
information regarding KVM switches, Serial Console servers, rack mount monitors,
keyboards and all related options please see the following URL: http://www.hp.com/go/kvm.
NOTE: Cat5e cables
are required to connect Serial Adapters to Serial Console Servers. Additional
Serial Adapters and Cat5e cables can be found at the following URL: http://www.hp.com/go/kvm.
NOTE: For additional
information regarding KVM switches, Serial Console servers, rack mount monitors,
keyboards and all related options please see the following URL: http://www.hp.com/go/kvm.
Service
and Support Offerings (HP Care Pack Services)
Hardware Services
On-site Service
Next Business Day On-site
Service, 5-Day x 9-Hour Coverage, 3 Years, Electronic
U4445E
4-Hour On-site Service,
5-Day x 13-Hour Coverage, 3 Years, Electronic
U4446E
4-Hour On-site Service,
7-Day x 24-Hour Coverage, 3 Years, Electronic
U4447E
6-Hour Call to Repair, On-site
Service, 7-Day x 24-Hour Coverage, 3 Years, Electronic
U4448E
Installation &
Start-up Services
Hardware Installation, Electronic
U4456E
Installation & Start-Up
of a ProLiant server and Microsoft or Linux O/S per the Customer Description
and/or Data Sheet. To be delivered on a scheduled basis 8am-5pm, M-F,
excl. HP holidays, Electronic
U4457E
Support Plus
Onsite HW support, 8am-9pm,
M-F, 4hr response and Microsoft O/S SW Tech support offsite, onsite
at HP's discretion, 8am-9pm, M-F 2hr response time excl. HP holidays,
Electronic
U4458E
Support Plus 24
Onsite HW support 24x7,
4hr response and Microsoft O/S SW Tech support offsite, onsite at
HP's discretion, 24x7 2hr response time incl. HP holidays, Electronic
U4459E
Onsite HW support 24x7,
4hr response and SuSE Linux SW Tech support offsite, onsite at HP's
discretion, 24x7 2hr response time incl. HP holidays, Electronic
U6306E
Onsite HW support 24x7,
4hr response and Red Hat ES Linux SW Tech support offsite, onsite
at HP's discretion, 24x7 2hr response time incl. HP holidays, Electronic
Standard Memory - Pentium 4 Models
512 MB
PC3200 Unbuffered ECC DDR SDRAM installed (1 x 512 MB SDRAM DIMM)
Standard Memory Replaced with Optional Memory
Up
to 4096 MB memory is available with the optional installation of PC3200
Unbuffered ECC DDR SDRAM DIMM Memory kits.
These systems support PC3200
DDR memory and come standard with a single PC3200
DIMM installed.
The system board provides four DIMM sockets:
Socket 1 (blue connector), channel A
Socket 2 (black connector), channel A
Socket 3 (blue connector), channel B
Socket 4 (black connector), channel B
DIMMs do not need to be installed in pairs although
installation of pairs (an equal DIMM for each channel) provides the best
performance. The BIOS will detect the DIMM population and set the system
accordingly as follows:
Single-channel mode - DIMMs installed for one channel
only
Dual-channel asymmetric mode - DIMMs installed for
both channels but of unequal channel capacities.
Dual-channel interleaved mode (recommended) - DIMMs
installed for both channels and offering equal channel capacities, proving
the highest performance.
These systems require DIMMs with the following parameters:
Unbuffered
256 MB, 512 MB, and 1 GB memory technology
PC3200
ECC DIMMs only
The first DIMM should be installed in Socket 1. A DIMM
should not be installed in Socket 2 without a DIMM in Socket. Likewise
a DIMM should not be installed in Socket 4 without a DIMM in Socket 3.
A DIMM need not be installed in Socket 2 in order to install a DIMM in
Socket 3.
The table below shows some of the suggested memory configurations
for these systems.
NOTE: Table below does not list all
possible configurations. Balanced-capacity, dual-channel loading yields
best performance.
NOTE:
Use of SAS hard drives in SATA/SAS models requires installation of the Smart Array
P600.
Hot Plug Serial
ATA - (Hot Plug SATA/SAS Models Only)
Quantity Supported
Position Supported
Controller
80GB
1.5G SATA 7.2K 160GB 1.5G SATA 7.2K 250GB 1.5G SATA 7.2K
Up
to 4*
0,
1
Integrated four port SATA
Controller with RAID 0/1
Up to 2*
0,
1, 2, 3
Integrated four port SATA
Controller with RAID 0/1
Up
to 4
0, 1, 2, 3
HP
6-port SATA RAID controller
*NOTE:
A maximum of two hard drives are supported when integrated RAID is enabled. Use
of hot plug SATA hard drives in positions 2 and/or 3 requires either a non-RAID
configuration or installation of the HP 6-port SATA RAID controller (P/N 372953-B21)
and the HP 4-port SATA/SAS target fan cable (P/N 389653-B21). NOTE:
Hot plug capability and drive LED status support requires installation of the
HP 6-port SATA RAID controller.
Non-Hot
Plug SATA - (Non-Hot Plug SATA models only)
Quantity Supported
Position Supported
Controller
80GB 1.5G SATA 7.2K 160GB 1.5G SATA 7.2K 250GB 1.5G SATA 7.2K
Up
to 2*
0,
1
Integrated four port SATA Controller
Up to 4*
0, 1, 2, 3
Integrated
four port SATA Controller with RAID 0/1
Up
to 4*
0,
1, 2, 3
HP 6-port SATA RAID controller
*NOTE: A maximum
of two hard drives are supported when integrated RAID is enabled. Use of non-hot
plug SATA hard drives in positions 2 and/or 3 requires either a non-RAID configuration
or installation of the HP 6-port SATA RAID controller (P/N 372953-B21) and two
of the HP 2-port SATA/SAS cables (P/N 379093-B21). NOTE: Drive LED
status support requires installation of the HP 6-port SATA RAID controller.
External Storage
Quantity
Supported
Position
Supported
Host Controller or Adapter
Modular Smart Array 30 Family
External
Smart Array 642 Controller
Maximum Storage Capacity - SATA Models
(SCSI Attached (Enclosure))
Internal
1.0TB
(4 x 250GB)
External
29.40TB
(14 x 300GB) x 7 (Requires additional SCSI controllers in slots)
Total
30.40TB
Maximum Storage Capacity - SCSI Models
(SCSI Attached (Enclosure))
NOTE:
Support for either one internal or one external SCSI channel is available.
This is achieved using an internal to external SCSI cable option kit (PN 159547-B22)
and SCSI knockout bracket.
Integrated 4 Channel SATA Controller (SATA NHP Models only)
Drives Supported
Up to 4 SATA hard drives (1 drive/channel)
Channels
4
Storage Capacity
1 TB
Maximum SATA Channel Transfer Rate
150 MB/s per channel
SATA Protocols
SATA-1a
Internal SATA Connectors
One 4-lane connector (all four channels)
Single Channel Ultra320 SCSI Adapter (SCSI Models only)
Drives Supported
Up to 15 SCSI devices Wide
Data Transfer Method
64-bit/100-MHz PCI bus-master
SCSI Channel Transfer Rate
320 MB/s per channel
Maximum Transfer Rate per PCI
Bus (peak)
1033 MB/s per channel
SCSI Protocols
Ultra320, Wide Ultra3, Wide Ultra2,
Wide Ultra SCSI-3, Fast-Wide SCSI-2, and Fast SCSI-2
Fast SCSI-2
Electrical Protocol
Low Voltage Differential (LVD)
SCSI Termination
Active Termination
External SCSI Connectors
None.
NOTE: To implement
an external SCSI connection, install an optional controller or internal
to external SCSI option kit (part number 159547-B22 for HD68 or 333370-B21
for VHDCI).