3. PCI-X I/O Expansion Assembly with (1) 133MHz
Full Height, Full-Length PCI-X slot which supports PCI Express
with optional riser board and (1) 133MHz Low-Profile, Half-Length
PCI-X Slot.
4. Memory Bank 1A & 1B, supporting up to 8 GB
PC3200 DDR1 SDRAM
5. Processor 1
6. Processor 2
7. Memory Bank 2A & 2B, supporting up
to 8 GB PC3200 DDR1 SDRAM
8. System Fans
9. Power ON/OFF Button
10. Front USB Ports
11. System LEDs
12. Optional CD or DVD-ROM Drive
13. Non-Hot Plug SATA OR SCSI Hard
Drive Bay
14. Non-Hot Plug SATA OR SCSI Hard
Drive Bay
What's New
Supports 1 or 2 AMD Opteron Rev. E processors with 1 GHz HyperTransport
Technology
At A Glance
Processors:
AMD 8132 Chipset for PCI-X support and NVIDIA nForce Professional
2200 MCP for PCI Express
DL145 G2 Memory:
1 or 2 GB of PC3200 DDR SDRAM running at 400 MHz with Advanced
ECC capabilities standard (depending on model), expandable to 16
GB
Storage Controller:
Integrated Dual Broadcom 10/100/1000 5721 NICs (Wake on LAN and
PXE capable)
Embedded SATA Controller
Internal Drive Support:
Support for up to two SATA and or SCSI Non Hot Plug hard drives
Internal storage capacity of up to 1TB (2 x 500GB non-hot plug
2.5" SATA HDDs), or 292GB (2 x 146GB NHP SCSI HDDs)
Network Controller:
Integrated Dual Broadcom 5721 10/100/1000 NICs (Wake on LAN and
PXE capable)
Expansion Slots:
Two PCI-X 64-bit/133MHz PCI slots operating at 3.3 volts (one
full-length/full-height, one low-profile); optional PCI Express
x16 in place of full-size slot
USB Ports:
Four USB ports (two rear, two front)
Optical Drives:
Optional DVD- or CD-ROM drive
Power Supply:
500W Power Supply (Non-Hot Plug, autoswitching)
Form Factor:
Rack Mount (1U)
Management:
HP ProLiant Lights Out 100i Remote Management standard
IPMI 2.0 support
ROM Setup Utility
Warranty:
Protected by HP Services, including a one-year, limited warranty,
Parts only 1 year limited Global warranty - Certain restrictions
and exclusions apply.
NOTE: For the Standard Features shipped
in the "Factory Integrated Models", please see the "Configuration
Information - Factory Integrated Models" section.
Integrated NVIDIA GeForce2 GPU
with 16MB DDR video memory
Form
Factor
Rack Mount (1U)
ProLiant Essentials
Foundation Pack Software
Optional ProLiant
Essentials Value Packs
Optional software offerings
that selectively extend the functionality of an Adaptive Infrastructure
to address specific business problems and needs:
Intelligent Networking Pack - detects and analyzes network bottlenecks
or broken network linkages and steers traffic to the optimum route based
on network conditions, plus it provides an extra layer of protection.
The virus throttle feature of the solution slows the propagation of
fast spreading virus.
Rapid Deployment Pack (RDP) is an automated deployment and provisioning
solution for all ProLiant servers. RDP includes the ProLiant Integration
Module featuring ProLiant server pre-configured events for OS installation,
and optimized software drivers, firmware and management agents. Every
RDP disc includes 10-node trial licenses for evaluation purposes. RDP
requires a license for each server deployed and is available for purchase
with HP servers. For more information, visit: http://www.hp.com/servers/rdp.
Vulnerability and Patch Management Pack - identifies and remediates
software security vulnerabilities due to missing patches as well as
operating system configurations that can be exploited by viruses, worms
and other blended threats.
NOTE: Flexible
and volume quantity license kits are available for ProLiant Essentials Value
Packs. Refer to http://www.hp.com/servers/proliantessentials
or the various ProLiant Essentials Value Pack product QuickSpecs for more
information. NOTE: For more information regarding ProLiant Essentials Software,
please see the following URL: http://www.hp.com/servers/proliantessentials.
Industry Standard
Compliance
ACPI V2.0 Compliant
PCI 2.2 Compliant
PXE Support
WOL Support
Microsoft® Logo certifications
IPMI 2.0 Compliant
Manageability
HP ProLiant Lights Out 100i
Remote Management integrated standard
Security
Power-on password
Setup password
Server Power Cords
One 10' Highline IEC Power cord
ships standard (for connection to a Power Distribution Unit). Units shipped
in Japan will have a 12' power cord.
NOTE: Rack models
ship standard with a 10' IEC cable. Localized cables included with geographic
specific models in other world regions
6 - Non-hot plug, Non-redundant
system fans shipped standard
OS
Support
Microsoft Windows® 2000
Server (32-bit) Microsoft Windows 2000 Advanced Server (32-bit) Microsoft
Windows 2003 Standard Edition (32-bit) Microsoft Windows 2003 Enterprise Edition
(32-bit) Microsoft Windows 2003 Web Edition (32-bit) Microsoft Windows
2003 for Extended Systems Standard Edition (64-bit) Microsoft Windows 2003
for Extended Systems Enterprise Edition (64-bit)
Red Hat Enterpise Linux
SUSE Linux 8 Enterprise Server
Solaris 10 32/64-bit
Rack 10000 series Cabinets
The increasing power of new high-performance processor technology requires
increased cooling efficiency for rack-mounted servers. The 10000 Series
Racks provide enhanced airflow for maximum cooling, allowing these racks
to be fully loaded with servers using the latest processors.
CAUTION: If a third-party rack is
used, observe the following additional requirements to ensure adequate airflow
and to prevent damage to the equipment:
Front and rear doors: If your 42U server rack includes closing front and
rear doors, you must allow 5,350 sq cm (830 square inches) of hole evenly
distributed from top to bottom to permit adequate airflow (equivalent to
the required 64 percent open area for ventilation).
Side: The clearance between the installed rack component and the side panels
of the rack must be a minimum of 7 cm (2.75 inches)
CAUTION: Always use blanking panels
to fill all remaining empty front panel U-spaces in the rack. This arrangement
ensures proper airflow. Using a rack without blanking panels results in
improper cooling that can lead to thermal damage.
NOTE: For additional information,
refer to the Setup and Installation Guide or the Documentation CD provided
with the server, or to the server documentation located in the Support section
at the following URL:http://h18000.www1.hp.com/products/servers/proliantdl140/index.html
Telco Rack Support
Telco Rack Kit:
Support for all 2-post Telco racks requires the use of the standard rack
kit and an additional option kit from Rack Solutions. http://www.racksolutions.com/hp
HP Factory Express Capability
HP Factory Express offers configuration,
customization, integration and deployment services for HP servers and storage
products. Customers can choose how their factory solutions are built, tested,
integrated, shipped and deployed.
Factory Express offers service packages for simple configuration, racking,
installation, complex configuration and design services as well as individual
factory services, such as image loading, asset tagging, and custom packaging.
HP products supported through Factory Express include a wide array of
servers and storage: HP Integrity, HP ProLiant, HP ProLiant Server Blades,
HP BladeSystem, HP 9000 servers as well as the MSA1000, VA7xxx, EVA, XP,
rackable tape libraries and configurable network switches.
For more information on Factory Express services for your specific server
model please contact your sales representative or go to http://www.hp.com/go/factory-express.
HP Enterprise Configurator
The HP eCo-Enterprise Configurator
now provides factory default racking for our HP hardware portfolio. This
approach is aligned with our strategic direction to meet the needs and expectations
of our valued customers. If you require "custom" rack configuration,
please contact HP's Customer Business Center or an Authorized Partner for
assistance.
Service and Support
This product is covered by a global limited warranty and supported by
HP Services and a worldwide network of resellers and service providers.
Hardware diagnostic support and repair is available for three years from
date of purchase. Support for software and initial setup is available
for 90 days from date of purchase. Additional support may be covered under
the warranty or available for an additional fee. Enhancements to warranty
services are available through HP Care Pack services or customized service
agreements.
HP Care Pack services include coverage for the HP branded hardware options
qualified for the server, purchased at the same time or afterward, internal
to the enclosure, as well as 22" and smaller external monitors and
tower UPS options up to 3kVA; these items will be covered at the same
service level and for the same coverage period as the server. Coverage
of UPS Battery is not included, standard warranty terms & conditions
apply. For servers or storage systems installed within a rack, service
also covers all HP qualified rack options installed within the same rack.
HP services provide continuous care and support expertise with committed
response designed to meet your IT and business needs.
To fully capitalizing on your HP ProLiant servers' capabilities requires
a service partner who thoroughly understands your server technology and
systems environment. HP Services, an industry leader in provision of multi
vender support solutions provides a range of support services designed
to meet the varying needs of business. Whether an SMB or large global
corporation HP has a ProLiant server support offer to help you speedily
deploy and maximize system uptime.
Enhanced Care Minimum recommended service support offer designed
to ensure customers have access to expert assistance, whenever they need
it.
Next Business Day on site coverage, 3 Years
Continuance Care Recommended service, delivering cost-effective
support options designed to extend HP Services committed response and
guaranteed fix times, designed to speed problem identification and resolution.
4-Hour On-site Service, 5-Day x 13-Hour Coverage, 3 Years
Total Care Highest HP Support service level recommend to help
increase IT performance and availability with comprehensive, integrated
hardware and software services
4-Hour On-site Service, 7-Day x 24-Hour Coverage, 3 Years
Deployment Services HP Installation and Start Up services designed
to take time, risk, and worry out of the deployment of ProLiant servers
and free customers IT support staff to focus on what they do best,
their business.
Installation of a ProLiant server as per Data Sheet. To be delivered
on a scheduled basis 8am-5pm, M-F, excl. HP holidays
NOTE:
High Performance Computing (HPC) interconnect technologies are available
for the DL145 under the Cluster Platform product portfolio. These high-speed
interconnects are fully supported by HP when they are part of these configure
to order clusters. Solutions can be defined with a lot of flexibility with
the help of configuration tools. Please visit the following URL to configure
HPC Clusters with InfiniBand, Gigabit Ethernet or Myrinet Interconnects:
http://www.hp.com/techservers/clusters/ucp/index.html
Configuration Information - Factory Integrated Models (North America only)
NOTE: For Configure to Order requirements within EMEA region,
please consult local Sales Contact. NOTE: HP does not allow factory integration of options into standard
models listed above.
Configure-to-order servers must start with a CTO Chassis. NOTE: This product offering does not support HP Factory Express
Server Configuration Level 1. NOTE: FIO indicates that this option is a Factory Installable Option.
Step 1: Base Configuration
SCSI Model
HP ProLiant DL145 G2 SCSI Rack
Chassis
378024-405
Factory Integrated Model ships
with:
Integrated Dual Broadcom 5721
10/100/1000 NICs (Wake on LAN and PXE capable)
HP U320 Internal SCSI Cable Kit
Two available 64-bit/133MHz PCI-X
slots, including one full-length/full height and one low-profile/half height
slot NOTE: The low-profile/half height
slot houses the SCSI HBA when installed.
500 Watt power supply
NOTE: Must select
HP Low Profile U320 SCSI HBA, (P/N 390402-B21) in Step 2 when selecting
the SCSI Rack Chassis, (P/N 378024-405) NOTE: The selection of SCSI Model (P/N 376343-405), requires the
selection of (1) SCSI Controller. Please see Step 3 of this section for
compatible SCSI Controllers.
SATA Model
HP ProLiant DL145 G2 SATA Rack
Chassis
389695-405
Factory Integrated Model ships
with:
Integrated Dual Broadcom 5721
10/100/1000 NICs (Wake on LAN and PXE capable)
Embedded SATA Controller
Two available 64-bit/133MHz PCI-X
slots, including one full-length/full height and one low-profile/half height
slot
500 Watt power supply
Rack Mount (1U)
Step 2: Choose Required Options
(only one of the following from each list unless otherwise noted)
Base Processors
AMD O285 2.6 GHz/1MB DL145 G2
FIO BASE NOTE: If 2 processors are desired,
select one 411097-B21and one 411097-B21.
411097-B21
AMD O280 2.4 GHz/1MB DL145 FIO
BASE NOTE: If 2 processors are desired,
select one 399444-B21and one 399444-B21.
399444-B21
AMD O275 2.2 GHz/ 1MB DL145 G2
FIO BASE NOTE: If 2 processors are desired,
select one 391782-B21and one 391782-B21.
391782-B21
AMD O254 2.8 GHz/1MB DL145 G2
FIO BASE NOTE: If 2 processors are desired,
select one 396861-B21and one 396861-B21.
396861-B21
AMD O252 2.6 GHz/1MB DL145 G2
FIO BASE NOTE: If 2 processors are desired,
select one 378690-B21and one 378690-B21.
ProLiant Essentials Intelligent
Networking Pack Windows Edition and Linux Edition
ProLiant Essentials Intelligent
Networking Pack Windows Edition, Single Server License NOTE: For use with a single server.
Contains one license with a unique license activation key and documentation.
372906-B21
ProLiant Essentials Intelligent
Networking Pack Linux Edition, Single Server License . NOTE: For use with a single server.
Contains one license with a unique license activation key and documentation.
NOTE: Flexible
and volume quantity license kits are available for ProLiant Essentials Value
Packs. Refer to http://www.hp.com/servers/proliantessentials
or the various ProLiant Essentials Value Pack product QuickSpecs for more
information. NOTE: For more information regarding ProLiant Essentials Software,
please see the following URL: http://www.hp.com/servers/proliantessentials.
NOTE: When purchasing
systems with the 500GB NHP SATA drives, please reference the Configuration
Information Section of this QuickSpecs to order via Configuration to Order.
Multibay II DVD/CD-RW Combo Drive
NOTE: When purchasing the Multibay
II DVD/CD-RW Combo Drive, (PN PA850A), the USB 2.0 Multibay II Cradle (PN
PA509A) is required.
PA850A
USB 2.0 Multibay II Cradle , External NOTE: When purchasing the Multibay
II DVD/CD-RW Combo Drive (P/N 850A), the USB 2.0 Multibay II Cradle (P/N
PA509A) is required.
PA509A
Storage Controllers
and options
HP U320 Internal SCSI Cable Kit
385749-B21
64-Bit/133-MHz Single Channel
Ultra320 SCSI HBA G2
HP StorageWorks 1U Rack-mount
kit NOTE: The 1U Rack-mount Kit (PN A7445A)
can support up to (2) half-height tape drives and compatible with multiple
Single-Ended and LVD SCSI tape drives including the DAT 24, DAT 40, DAT
72, DLT VS80, DLT VS160, Ultrium 215, Ultrium 232 and Ultrium 448 tape drives.
HP DP Express Backup Server Upgrade
for ProLiant Software
BB117AP
HP DP Express Package for Microsoft
Small Business Server
BB118AA
NOTE: Please see
the HP Data Protector Express QuickSpecs for additional information regarding
the purchase of HP Data Protector Express software: http://h18000.www1.hp.com/products/quickspecs/12337_div/12337_div.html
(Worldwide) NOTE: To obtain a free licensed copy of HP Data Protector Express
for ProLiant edition software, please visit the "Protect Your Data"
link accessible from your ProLiant server's System Management Homepage (SMH)
software (SmartStart 7.5 or later).
USB Options
HP USB 2-Button Optical Scroll
Mouse (Carbonite/Silver)
NOTE:
For additional information regarding KVM switches, Serial Console servers,
rack mount monitors, keyboards and all related options please see the following
URL:http://www.hp.com/go/kvm
NOTE: Cat5e cables
are required to connect Interface Adapters to Console Switches. Cat5e cables
can be found at the following URL: http://www.hp.com/go/kvm
NOTE: For additional
information regarding KVM switches, Serial Console servers, rack mount monitors,
keyboards and all related options please see the following URL: http://www.hp.com/go/kvm
NOTE:
Memory configurations listed do not apply to "Factory Integrated Models".
HP ProLiant DL145
G2 Single Processor Models
Standard Memory
1 GB (2 x 512 MB) or 2 GB (2 x 1 GB) of PC3200 DDR1 SDRAM running at 400
MHz, with Advanced ECC capabilities Memory installed (depending on model). Maximum Memory
Up to 16 GB of memory is available with the removal of the standard 512
MB or 1 GB of memory and the optional installation of 2 GB PC3200 Registered
ECC DDR1 SDRAM DIMM Memory kits.
Memory Options
The server provides double data
rate (DDR) synchronous dynamic RAM (SDRAM) that can improve memory clock
speed to at least 400-MHz. It activates output on both the rising and falling
edge of the system clock rather than on just the rising edge, potentially
doubling output. The server features the following advanced memory technologies:
Support for up to 16 GB of industry-standard PC3200 registered ECC
DDR1 SDRAM memory
Dual-Channel Memory Architecture
Memory Guidelines
Bank 1A must always be populated.
DIMMs must be installed in pairs and starting at the bank farthest
from the processor. Populate the SMALLEST DIMMs first.
If only installing 1 GB DIMMs, ensure that the Dual Rank DIMMs are
installed closest to the processor. Dual Rank can be determined by looking
for the "2R" or "2Rx8" wording on the label of the
DIMM.
All DIMMs in a bank must have the same part number.
DIMMs on different banks can be of different sizes.
Processor 2 must be installed before banks 2A and 2B are populated.
If processor 2 is installed, it is recommended that bank 2A be populated
before populating bank 1B.
For optimum performance it is recommended that a minimum of banks
1A and 1B be populated in a 2P configuration.
NOTE: Chart does
not represent all possible memory configurations.
NOTE: All temperature
ratings shown are for sea level. An altitude derating of 1.8° F per
1,000 ft (1° C per 304.8 m) to 10,000 ft (3048 m) is applicable. No
direct sunlight allowed. Upper operating limit is 10,000 ft (3048 m) or
70 Kpa/10.1 psia. Upper non-operating limit is 30,000 ft (9144 m) or 30.3KPa/4.4
psia. System performance may be reduced if operating with a fan fault or
above 30° C. NOTE: Storage maximum humidity of 90% is based on a maximum temperature
of 113° F (45° C).
Altitude maximum for storage corresponds to a pressure minimum of 70 KPa.