LO100i 10/100 Mbps LAN port for
IPMI management (RJ-45)
5.
System fans
7.
Video Port
6.
Optional CD-RW or DVD-ROM drive
8.
Serial Port
7.
Two USB ports
9.
Standard height/full-height PCI
Express x16 board
8.
Power on/off & system LEDs
9.
Optional 3rd and 4th 3.5"
Non-Hot plug SATA or hot plug SAS/SATA hard drive bays
10.
Standard 1st and 2nd 3.5"
Non-Hot plug SATA or hot plug SAS/SATA hard drive bays
11.
Expansion Slots:
One available x16 PCI-Express slot Gen2 slot
What's New
Support for SATA Hot Plug 3.5" Midline (MDL) Solid State Drives
Support for SAS Hot Plug 3.5" Enterprise (ENT) Hard Drives
At A Glance
The HP ProLiant DL160 G5p server is an affordable 1U, dual processor
capable server equipped with essential performance features that provide
customers with a platform to design a fully optimized solution. It is
ideal for general purpose and high performance computing.
Processors:
Supports up to two Intel® Quad-Core 5400 or Dual-Core 5200
sequence processors
Supports up to 128 GB PC2-5300 fully buffered DIMMs (DDR2-667) with
Advanced ECC
Supports up to 64 GB PC2-6400 fully buffered DIMMS (DDR2-800) with
Advanced ECC
Internal Drive Support:
Support for up to four 3.5" Non-Hot plug serial ATA (SATA)
hard drives or;
Support for up to four 3.5" Hot plug Serial Attached SCSI (SAS)
or SATA hard drives or
Support for up to four 3.5" Hot plug SATA 3G SSD's.
NOTE: Installation of the Hot Plug
Backplane 1U 2S Kit (445985-B21) is required if ordering third or
fourth Hard Drives for Hot Plug models only.
Internal storage capacity of up to 4.0TB (4 x 750GB Hot Plug 3.5"
SATA), 3.0TB (4 x 750 Non-Hot Plug SATA) or 4.0TB (4 x 1TB Hot Plug
3.5" SAS)
Network Controller:
Two embedded NC105i PCIe Gigabit Server Adapters
Storage Controllers:
Non-Hot Plug SATA Models: HP Embedded SATA RAID Controller
Hot Plug SAS/SATA Models: HP SC40Ge 4-Port Internal SAS HBA with
RAID 0, 1 NOTE: When using the SC40Ge
with SATA Hard Drives, 1.5G SATA Hard Drives are required.
Expansion Slots:
One full-length/full-height PCI-Express 2.0 x16
Infrastructure Management:
HP Lights Out 100i Advanced Remote Management with new licensed
key activated upgrades for Virtual KVM and virtual media support.
LO100i management support for the DL160 G5p includes:
IPMI 2.0 & SMASH CLP support
ROM Setup Utility
Improvements to virtual media with the addition of USB 2.0 drives
and protocol support for much faster transfer speeds and DVD-ROM support
plus simplified virtual media (floppy and CD with no FTTP server requirements)
Enhanced browser interface and embedded KVM over IP provides OS-independent
remote graphical console
USB Ports:
Five USB ports (two front, one internal, two rear)
Optical Drive:
Support for one (optional): DVD-ROM, DVD/CD RW
Power Supply:
650W Power Supply (Non-Hot Plug, Autoswitching)
Optional high-efficiency model
NOTE: Optional high-efficiency
model requires the purchase of HP Power Supply Backplane (453652-B21)
Form Factor:
Rack (1U)
Fixed mounting rails included with all models
Deployment/Serviceability:
Tool-less access to all system components for easy in rack serviceability
Customer Self Repair (CSR): HP products are designed with many CSR
parts to minimize repair time and allow for greater flexibility in
performing defective parts replacement
Warranty:
This product is covered by a global limited warranty and supported
by HP Services and a worldwide network of HP Authorized Channel Partners.
Hardware diagnostic support and repair is available for one year from
date of purchase. Support for software and initial setup is available
for 90 days from date of purchase. Enhancements to warranty services
are available through HP Care Pack services or customized service
agreements. Hard drives have either a one year or three year warranty;
refer to the specific hard drive QuickSpecs for details. NOTE: Server Warranty includes
1 year Parts, 1 year Labor, 1-year on-site support with next business
day response. Warranty repairs may be accomplished through the use
of Customer Self Repair (CSR) parts. These parts fall into two categories:
1) Mandatory CSR parts are designed for easy replacement. A travel
and labor charge will result when customers decline to replace a Mandatory
CSR part; 2) Optional CSR parts are also designed for easy replacement
but may involve added complexity. Customers may choose to have HP
replace Optional CSR parts at no charge. Additional information regarding
worldwide limited warranty and technical support is available at:
http://h18004.www1.hp.com/products/servers/platforms/warranty/index.html.
NOTE: For the Standard Features shipped
in the Factory Integrated Models, please see the "Configuration Information
- Factory Integrated Models" section.
Processor One of the following depending on Model
Quad-Core Intel® Xeon®
processor X5482 (3.20 GHz, 120W, 1600MHz FSB) NOTE: Available through Configure
To Order only. See Factory Integration Models section for more details.
Quad-Core Intel® Xeon®
processor X5472 (3.00 GHz, 120W, 1600MHz FSB) NOTE: Available through Configure
To Order only. See Factory Integration Models section for more details.
Quad-Core Intel® Xeon®
processor X5470 (3.33 GHz, 120W, 1333MHz FSB) NOTE: Available through Configure
To Order only. See Factory Integration Models section for more details.
Quad-Core Intel® Xeon®
processor X5460 (3.16 GHz, 120W, 1333MHz FSB) NOTE: Available through Configure
To Order only. See Factory Integration Models section for more details.
Quad-Core Intel® Xeon®
processor L5430 (2.60 GHz, 50W, 1333MHz FSB) NOTE: Available through Configure
To Order only. See Factory Integration Models section for more details.
Quad-Core Intel® Xeon®
processor L5420 (2.50 GHz, 50W, 1333MHz FSB) NOTE: Available through Configure
To Order only. See Factory Integration Models section for more details.
Quad-Core Intel® Xeon®
processor L5410 (2.33 GHz, 50W, 1333MHz FSB) NOTE: Available through Configure
To Order only. See Factory Integration Models section for more details.
Quad-Core Intel® Xeon®
processor E5472 (3.00 GHz, 80W, 1600MHz FSB) NOTE: Available through Configure
To Order only. See Factory Integration Models section for more details.
Quad-Core Intel® Xeon®
processor E5462 (2.80 GHz, 80W, 1600MHz FSB) NOTE: Available through Configure
To Order only. See Factory Integration Models section for more details.
Quad-Core Intel® Xeon®
processor E5430 (2.66 GHz, 80W, 1333MHz FSB) NOTE: Available through Configure
To Order only. See Factory Integration Models section for more details.
Quad-Core Intel® Xeon®
processor E5405 (2.00 GHz, 80W, 1333MHz FSB) NOTE: Available through Configure
To Order only. See Factory Integration Models section for more details.
Dual-Core Processors
Dual-Core Intel® Xeon®
processor X5272 (3.40 GHz, 80W, 1600MHz FSB) NOTE: Available through Configure
To Order only. See Factory Integration Models section for more details.
Upgradeability
Upgradeable to two processors
Chipset
Intel® 5400 Chipset
Cache Memory
12 MB (2 x 6 MB) Level 2 cache
(5400 sequence)
6 MB (1 x 6 MB) Level 2 cache
(5200 sequence)
Memory Protection
Advanced ECC capabilities
Memory
Types
PC2-5300 Fully Buffered
DIMMs (DDR2-667)
PC2-6400 Fully Buffered
DIMMS (DDR2-800)
Maximum
128 GB
(16 x 8 GB) (PC2-5300)
64 GB
(16 x 4 GB) (PC2-6400)
Network Controller
Two embedded NC105i PCIe Gigabit
Server Adapters
Expansion Slots #
Technology
Bus Width
Connector Width*
Bus Number*
Device No.**
Form Factor
Notes
1
PCI-Express 2.0
x16
x16
1
0
Full length, full height
3.3 volts
* Default bus assignment.
Inserting cards with PCI bridges may alter the actual bus assignment number.
** Slots are enumerated
differently based on OS. MS OS's enumerate from lowest to highest Device
ID by bus (starting with the lowest bus).
Storage Controller
Non-Hot Plug SATA Models
HP Embedded SATA RAID Controller
(integrated into the south-bridge) supporting SW RAID 0,1
Hot Plug SATA/SAS Models
HP SC40Ge HBA with RAID 0, 1 NOTE: When using the SC40Ge with
SATA Hard Drives, 1.5G SATA Hard Drives are required.
NOTE:
A diskette drive, USB floppy drive key or virtual FDD using LO100 Advanced
Pack is needed to install storage controller drivers during a Windows operating
system installation from a CD.
Storage
Optical Drives:
DVD-ROM
8x IDE (ATAPI) DVD-ROM drive,
slim (optional)
DVD/CD RW
24x IDE (ATAPI) CD-ROM drive
(optional)
Diskette Drives
Via USB only
Drive Bays:
Non-Hot Plug SATA
Up to 4 Non-hot plug SATA 3.5"
drives
Hot Plug SATA/SAS
Up to 4 Hot plug SAS/SATA 3.5"
drives
Maximum Internal
Storage
Non-Hot Plug SATA
3.0TB
4 x 750GB
Hot Plug SATA
4.0TB
4 x 1TB
Hot Plug SAS
4.0TB
4 x 1TB
Interfaces
Parallel
None
Network RJ-45(Ethernet)
2 10/100/1000 NIC ports (plus
1 dedicated for the HP ProLiant Lights Out 100i Remote Management)
HP Lights-Out 100i Remote Management delivers affordable, entry level
remote management capabilities for HP ProLiant 100 Series servers with
embedded LO100i. It allows customers or their service providers to remotely
manage ProLiant 100 Series servers remotely over a LAN or the Internet
and consists of the following:
LO100i Standard is embedded remote management and provides basic remote
control via telnet, browser, and IPMI 2.0 and SMASH
LO100i Advanced Pack License are upgrades for all the features of
LO100i Select plus Virtual KVM (graphical hardware-based, remote console)
NOTE: Flexible and volume quantity (AKA)
license kits are available for both the Lights-Out 100i Advanced Pack
licenses as well as Electronic License To Use (E-LTU). AKA Tracking licenses
require a 100 unit minimum forecast at initial contract signing. For these
additional part numbers, please refer to each software products. QuickSpecs
at this link for more information: www.hp.com/go/lo100
Industry Standard
Compliance
ACPI V2.0 Compliant
PCI 2.2 Compliant
PXE Support
WOL Support
Microsoft® Logo certifications
IPMI 2.0, SMASH CLP compliant
Manageability
HP Lights-Out 100i Standard provides the following OS-independent remote
control capabilities:
Virtual power
System event log access
System health
Remote serial console (serial redirection)
Browser, Telnet access
SMASH-CLP compliant
IPMI 2.0 compliant
HP Lights-Out 100i Advanced Pack provides license key activated upgrades
to the following:
Virtual KVM (KVM over IP functionality embedded on the system board)
plus all of the LO100i Select Pack features above.
Security
Power-on password
Setup password
Server Power Cords
One 6' Highline (IEC-IEC) power cord ships standard NOTE: HP ProLiant DL servers no
longer ship standard with NEMA power cords (163719-002) that allow connection
to 110V US wall outlets in a home or office. ProLiant DL servers are primarily
connected to PDU's in data center racks so they now ship standard with
only a PDU power cord (416151-B21). If a user wishes to power a ProLiant
DL server using a 110V receptacle (NEMA-15), the NEMA power cord (227099-001)
must be ordered separately.
If customers require a local power cord, they can check the power cord
matrix for the appropriate cord. Please see the following power cord matrix:
http://www.hp.com/go/powercordmatrix.
UPS and PDU Power
Cord Matrix
Please see the UPS and PDU cable
matrix's on the HP Power Protection and Management page. Under Power Cords,
click on the "HP Power Cord Matrix" link. That link will list
cable descriptions, requirements, and specifications for UPS and PDU units.
Please see the following link: www.hp.com/products/powercords.
NOTE: For more information on HP's
Certified and Supported ProLiant Servers for OS and Virtualization Software
and latest listing of software drivers available for your server, please
visit our Support Matrix at: http://www.hp.com/go/supportos
and our driver download page http://www.hp.com/support/DL160G5p
Rack Airflow Requirements
Rack 10000 G2 series Cabinets
The increasing power of new high-performance processor technology requires
increased cooling efficiency for rack-mounted servers. The 10000 G2 Series
Racks provide enhanced airflow for maximum cooling, allowing these racks
to be fully loaded with servers using the latest processors.
CAUTION: If a third-party rack is
used, observe the following additional requirements to ensure adequate airflow
and to prevent damage to the equipment:
Front and rear doors: If your 42U server rack includes closing front and
rear doors, you must allow 5,350 sq cm (830 square inches) of hole evenly
distributed from top to bottom to permit adequate airflow (equivalent to
the required 64 percent open area for ventilation).
Side: The clearance between the installed rack component and the side panels
of the rack must be a minimum of 7 cm (2.75 inches)
CAUTION: Always use blanking panels
to fill all remaining empty front panel U-spaces in the rack. This arrangement
ensures proper airflow. Using a rack without blanking panels results in
improper cooling that can lead to thermal damage.
NOTE: For additional
information, refer to the Setup and Installation Guide or the Documentation
CD provided with the server, or to the server documentation located in the
Support section at the following URL: www.hp.com/servers/dl160.
Rack Support
The DL Fixed Rail System supports
installation in racks with square or round mounting holes (including Compaq/HP
7000, 9000, 10000 and HP series), with an adjustment range of 24" -
36".
Telco Rack Support
Installation into Telco 2 post,
and 4 post, or threaded holes racks requires a 3rd party option kit. For
additional information, please visit: www.racksolutions.com.
Factory Express Portfolio for
Servers and Storage
HP Factory Express offers configuration,
customization, integration and deployment services for HP servers and storage
products. Customers can choose how their factory solutions are built, tested,
integrated, shipped and deployed.
Factory Express offers service packages for simple configuration, racking,
installation, complex configuration and design services as well as individual
factory services, such as image loading, asset tagging, and custom packaging.
HP products supported through Factory Express include a wide array of servers
and storage: HP Integrity, HP ProLiant, HP ProLiant Server Blades, HP BladeSystem,
HP 9000 servers as well as the MSAxxxx, VA7xxx, EVA, XP, rackable tape libraries
and configurable network switches.
For more information on Factory Express services for your specific server
model please contact your sales representative or go to: http://www.hp.com/go/factory-express.
HP Enterprise Configurator
The HP eConfigure Enterprise Configurator now provides factory default
racking for our HP hardware portfolio. This approach is aligned with our
strategic direction to meet the needs and expectations of our valued customers.
If you require "custom" rack configuration, please contact HP's
Customer Business Center or an Authorized Partner for assistance.
Service and Support
HP Care Pack Services provide total care and support expertise with committed
response designed to meet your IT and business needs.
HP Care Pack Services provide total care and support expertise with committed
response designed to meet your IT and business needs.
HP Care Pack services include coverage for the HP branded hardware options
qualified for the server that are purchased at the same time or afterward
and internal to the enclosure. It also includes the 22" and smaller
external monitors and tower UPS options up to 3kVA. These items will be
covered at the same service level and for the same coverage period as
the server. Coverage of UPS Battery is not included and standard warranty
terms & conditions apply. For servers or storage systems installed
within a rack, service also covers all HP qualified rack options installed
within the same rack.
To fully capitalize on your HP ProLiant servers' capabilities requires
a service partner who thoroughly understands your server technology and
systems environment. HP Services, an industry leader in provision of multi
vender support solutions provides a range of support services designed
to meet the varying needs of business. Whether an SMB or large global
corporation HP has a ProLiant server support offer to help you speedily
deploy and maximize system uptime.
Recommended Service - Simplify ProLiant
solution implementation, maintenance and management.
Support Service - 3 Year, 9x5 Next Business
Day coverage, excluding HP holidays only
Deployment Service - Hardware Installation
only
Enhanced Service - Optimize service level
to increase IT performance and availability
Support Service - 3 Year 13x5 Same Business
Day, 4-Hour response coverage
Deployment Service - Installation and
Start-up only
Installation & Start-Up of a ProLiant server and Microsoft or Linux
O/S per the Customer Description and/or Data Sheet. To be delivered on
a scheduled basis 8am-5pm, M-F, excl. HP holidays.
NOTE:
High Performance Computing (HPC) interconnect technologies are available
for the DL160 G5p under the Cluster Platform product portfolio. These high-speed
interconnects are fully supported by HP when they are part of these configure
to order clusters. Solutions can be defined with a lot of flexibility with
the help of configuration tools. Please visit the following URL to configure
HPC Clusters with InfiniBand, Gigabit Ethernet or Myrinet Interconnects:
http://www.hp.com/techservers/clusters/ucp/index.html
Configuration Information - Factory Integrated Models
NOTE: This section lists some of the steps required to configure a Factory
Integrated Model. To ensure only valid configurations are ordered, HP recommends
the use of an HP approved configurator. Contact your local sales representative
for additional information. NOTE: FIO indicates that this option is
a Factory Installable Option.
Step
1: Base Configuration (choose one of the following configurable models)
Non-Hot
Plug Model
HP ProLiant DL160G5p Non-Hot
Plug CTO Chassis
495834-B21
Factory
Integrated Model ships with:
Two
embedded NC105i PCIe Gigabit Server Adapters (WOL & PXE-capable)
One available PCI-Express 2 slot: Slot 1: full-length/full-height
650
Watt Power Supply
One
Highline IEC Power Cord
6 Non-Hot Plug Fans
Rack (1U), (1.75 in / 4.45 cm)
Fixed Rails
Hot Plug Model
HP
ProLiant DL160G5p Hot Plug CTO Chassis
495835-B21
Factory
Integrated Model ships with:
Two
embedded NC105i PCIe Gigabit Server Adapters (WOL & PXE-capable)
One available PCI-Express 2 slot: Slot 1: full-length/full-height
650
Watt Power Supply
One
Highline IEC Power Cord
6 Non-Hot Plug Fans
Rack (1U), (1.75 in / 4.45 cm)
Fixed Rails
Step 2: Choose Required
Options (only one of the following from each list unless otherwise noted)
Hard Drive (NOTE: Only required when purchasing
Non-Hot Plug CTO Chassis Model (P/N 495834-B21) in Step 1.
NOTE: The components
of a storage subsystem (e.g. the drive, the HBA/controller, firmware, and
the server backplane) should operate at the same data transfer rate or the
system bandwidth will be negotiated down to an acceptable level for all
components. NOTE: Hard drives have either a one year or three year warranty;
refer to the specific hard drive QuickSpecs for details.
SATA Non-Hot Plug 3.5" Midline
(MDL) Drives
NOTE: A minimum
of one hard drive is required when purchasing Non-Hot Plug CTO Chassis Model (P/N
495834-B21) in Step 1. NOTE: SATA Non-Hot Plug Hard Drives to be used
with Non-Hot Plug CTO Chassis Models Only).
HP SC40Ge SAS HBA, FIO NOTE: When using the SC40Ge with SATA Hard
Drives, 1.5G SATA Hard Drives are required. NOTE:
Recommended HBA when purchasing Hot Plug CTO Chassis Model (P/N 495835-B21).
449176-B21
Step
3: Choose Additional Options for Factory Integration
NOTE:
For additional options, please refer to the "Core Options and Additional
Options" sections below. Some options may not be available for factory integration.
Please contact an HP sales representative for additional information.
NOTE: The components
of a storage subsystem (e.g. the drive, the HBA/controller, firmware, and
the server backplane) should operate at the same data transfer rate or the
system bandwidth will be negotiated down to an acceptable level for all
components. NOTE: Hard drives have either a one year or three year warranty;
refer to the specific hard drive QuickSpecs for details.
HP NC382T PCI Express Dual Port
Multifunction Gigabit Server Adapter NOTE: Supported only by the HP ProLiant
DL160G5p Non-Hot Plug CTO Chassis (P/N 495834-B21).
HP NC522SFP Dual Port 10GbE Server
Adapter NOTE: A minimum of two Gigabytes
(2 GB) of server memory is required per each NC522SFP adapter. NOTE: Direct Attach Cable (DAC) for copper environments or fiber
transceivers and cables for fiber-optic environments must be purchased separately.
HP LO100i Advanced Pack, No Media
1-Server License including 1 year of 24x7 Technical Support and Updates
530521-B21
NOTE: Flexible
and volume quantity (AKA) license kits are available for Lights-Out 100
Advanced Pack licenses as well as Electronic License To Use (E-LTU). AKA
Tracking licenses require a 100 unit minimum forecast at initial contract
signing. For these additional license kits, please refer to each software
products' QuickSpecs at this link for more information: http://www.hp.com/go/lo100
HP Insight Software
HP Insight Rapid Deployment software
HP Insight Rapid Deployment software
No Media 1-Server License including 1 year of 24x7 Technical Support and
Updates NOTE: This license allows 1 server
to be deployed. Customer will receive a printed license entitlement certificate
via physical shipment. The license entitlement certificate must be redeemed
online or via fax in order to obtain the license activation key(s). Includes
one year of 24 x 7 HP Software Technical Support Service.
NOTE: Cat5e cables
are required to connect Interface Adapters to Console Switches. Cat5e cables
can be found at the following URL: http://www.hp.com/go/kvm
NOTE: For additional
information regarding KVM switches, Serial Console servers, rack mount monitors,
keyboards and all related options please see the following URL: http://www.hp.com/go/kvm
USB Options
HP 1GB USB 2.0 Floppy Drive Key
442085-B21
USB Floppy Drive
DC361B
HP USB-P/S2 Mouse
DC369A
HP USB Internal Cable Kit
451363-B21
Service
and Support Offerings
(HP Care Pack Services)
Hardware Services 4-Hour On-site
Service
13-Hour x 5-Day Coverage, 3 Years,
Electronic
U9509E
24-Hour x 7 Day Coverage, 3 Years,
Electronic
U9510E
Hardware Services Next Business
Day On-Site Service
9-Hour x 5-Day Coverage, 3 Years,
Electronic
U9508E
Hardware Services 6-Hour Call
to Repair On-Site Service
NOTE:
Memory configurations listed do not apply to "Factory Integrated Models".
Standard
Memory
1GB (2x512MB) or 2GB (2 x 1GB) depending on model, PC2-5300 Fully Buffered
DIMM memory, with Advanced ECC.
Maximum Memory
Up to 128GB memory is available with the optional installation of PC2-5300
or up to 64GB PC2-6400 Fully Buffered DIMM memory kits. NOTE: Memory should be installed
in pairs and matched for optimum performance.
NOTE:
Chart does not represent all possible memory configurations.
Four Non-hot plug SATA or four
3.5" Hot-plug SAS/SATA hard drive bays
A
Optional DVD-ROM, or DVD/CD RW
Drive Support
Removable Media
Quantity
Supported
Position
Supported
Controller
DVD-ROM
Up to 1
A
Integrated IDE (ATAPI) (optional)
DVD/CD RW
Up to 1
A
Integrated IDE (ATAPI) (optional)
Hard Drives
NOTE:
The components of a storage subsystem (e.g. the drive, the HBA/controller,
firmware, and the server backplane) should operate at the same data transfer
rate or the system bandwidth will be negotiated down to an acceptable level
for all components. NOTE: Hard drives have either a one year or three year warranty;
refer to the specific hard drive QuickSpecs for details.
SATA Non-Hot Plug
3.5" Midline (MDL) Drives
Quantity
Supported
Position
Supported
Controller
750GB 3G SATA 7.2K
500GB 3G SATA 7.2K
250GB 3G SATA 7.2K
Up to 4
1-4
HP Embedded SATA RAID Controller
SATA Non-Hot Plug
3.5" Entry (ETY) Drives
Quantity
Supported
Position
Supported
Controller
160GB 3G SATA 7.2K
Up to 4
1-4
HP Embedded SATA RAID Controller
SATA
Hot Plug 3.5" Midline (MDL) Drives NOTE: Installation of the Hot Plug
Backplane 1U 2S Kit (445985-B21) is required if ordering third or fourth
Hard Drives for Hot Plug models only.
Quantity
Supported
Position
Supported
Controller
1TB 3G SATA 7.2K
750GB 3G SATA 7.2K 500GB 3G SATA 7.2K 250GB 3G SATA 7.2K
160GB 3G SATA 7.2K
Up to 4
1-4
HP SC40Ge 4-Port Internal SAS
HBA with RAID 0, 1 NOTE: When using the SC40Ge with
SATA Hard Drives, 1.5G SATA Hard Drives are required.
SATA
Hot Plug 3.5" Entry (ETY) Drives NOTE: Installation of the Hot Plug
Backplane 1U 2S Kit (445985-B21) is required if ordering third or fourth
Hard Drives for Hot Plug models only.
Quantity
Supported
Position
Supported
Controller
160GB 3G SATA 7.2K
Up to 4
1-4
HP SC40Ge 4-Port Internal SAS
HBA with RAID 0, 1 NOTE: When using the SC40Ge with
SATA Hard Drives, 1.5G SATA Hard Drives are required.
SAS Hot Plug 3.5"
Midline (MDL) Drives NOTE: Installation of the Hot Plug
Backplane 1U 2S Kit (445985-B21) is required if ordering third or fourth
Hard Drives for Hot Plug models only.
Quantity
Supported
Position
Supported
Controller
1TB 3G 15K
750GB 3G 15K
Up to 4
1-4
Embedded SATA with integrated
SATA RAID 0,1
SAS Hot Plug 3.5"
Enterprise (ENT) Drives NOTE: Installation of the Hot Plug
Backplane 1U 2S Kit (445985-B21) is required if ordering third or fourth
Hard Drives for Hot Plug models only.
Quantity
Supported
Position
Supported
Controller
600GB 6G SAS 15K
450GB 6G SAS 15K
450GB 3G SAS 15K
300GB 3G SAS 15K
146GB 3G SAS 15K
72GB 3G SAS 15K
Up to 4
1-4
HP SC40Ge 4-Port Internal SAS
HBA with RAID 0, 1
SATA Hot Plug 3.5"
Midline (MDL) Solid State Drives
Quantity
Supported
Position
Supported
Controller
120GB 3G SATA
60GB 3G SATA
Up to 4
1-4
HP SC40Ge 4-Port Internal SAS
HBA with RAID 0, 1 NOTE: When using the SC40Ge with
SATA Hard Drives, 1.5G SATA Hard Drives are required. Transfer rate: 1.5
Gb/s SATA, 3 Gb/s SAS
HP Smart Array P400 Controller
HP Smart Array P800 Controller
System
Leakage with all power supplies loaded (mA)
1.58
3.03
System
Inrush Current with all power supplies loaded (A)
19
37
Power cord requirements
Nema 5-15P to IEC320-C13
IEC320-C13 to IEC320-C14
NOTE:
Power shown is for a fully configured system consisting of (2) CPU, (8)
double-sided DIMMs, (2) HDDs, (1) CD-ROM, and (2) PCI cards.
Power Cord
AF556A
Server Power Cords
One 6' Highline (IEC-IEC) power cord ships standard NOTE: HP ProLiant DL servers no
longer ship standard with NEMA power cords (163719-002) that allow connection
to 110V US wall outlets in a home or office. ProLiant DL servers are primarily
connected to PDU's in data center racks so they now ship standard with
only a PDU power cord (416151-B21). If a user wishes to power a ProLiant
DL server using a 110V receptacle (NEMA-15), the NEMA power cord (227099-001)
must be ordered separately.
If customers require a local power cord, they can check the power cord
matrix for the appropriate cord. Please see the following power cord matrix:
http://www.hp.com/go/powercordmatrix.
- Click on the system of interest. Example: DL160 G5p
- Follow the instructions of the next screens.
Power Supply
Output
(per power supply)
Rated Steady-State Power
653.10W (at 100 VAC),
653.08W (at 200 VAC)
System Inlet Temperature
Operating
50° to 95° F (10°
to 35° C) at sea level with an altitude derating of 1.8°F per every
1000 ft (1.0°C per every 305 m) above sea level to a maximum of 10,000
ft (3050 m), no direct sustained sunlight. Maximum rate of change is 18°F/hr
(10°C/hr). The upper limit may be limited by the type and number of
options installed.
System performance may be reduced if operating with a fan fault or above
86°F (30°C).
Non-operating
40° to 140° F (-40°
to 60° C)
Maximum rate of change is 36°F/hr (20°C/hr).
Relative
Humidity
(non-condensing)
Operating
10% to 85% relative humidity (Rh),
82.4°F (28°C) maximum wet bulb temperature, non-condensing.
Non-operating
10% to 95% relative humidity (Rh),
101.7°F (38.7°C) maximum wet bulb temperature, non-condensing.
Altitude
Operating
10,000 ft (3050 m). This value
may be limited by the type and number of options installed. Maximum allowable
altitude change rate is 1500 ft/min (457 m/min).
Non-operating
30,000 ft (9144 m). Maximum allowable
altitude change rate is 1500 ft/min (457 m/min).
Acoustic Noise
Listed are the declared
A-Weighted sound power levels (LWAd) and declared average bystander position
A-Weighted sound pressure levels (LpAm) when the product is operating in
a 23°C ambient environment. Noise emissions were measured in accordance
with ISO 7779 (ECMA 74) and declared in accordance with ISO 9296 (ECMA 109).
Idle
LWAd
6.86
LpAm
52.36dBA
Operating
LWAd
6.89
LpAm
52.60dBA
Emissions Classification
(EMC)
FCC Rating
A
Normative Standards
CISPR 22; EN55022; EN55024; FCC
CFR 47, Pt 15; ICES-003; CNS13438; GB9254; K22;K24; EN 61000-3-2; EN 61000-3-3;
EN 60950-1; IEC 60950-1
NOTE:
Product conformance to cited product specifications is based on sample (type)
testing, evaluation, or assessment. This product or family of products is
eligible to bear the appropriate compliance logos and statements.
Embedded NC105i PCIe
Gigabit Server Adapter
Network Interface
Integrated 10/100/1000BASE-T
Transceiver
Combines a triple-speed
IEEE 802.3TM - Compliant Media Access Controller (MAC) with a triple-speed
Ethernet transceiver.
Data Transfer Method
Compliant to x1 PCIe
Specification
Network Transfer Rate
10Base-T (Half-Duplex)
10 Mb/s
10Base-T (Full-Duplex)
20 Mb/s
100Base-TX (Half-Duplex)
100 Mb/s
100Base-TX (Full-Duplex)
200 Mb/s
1000Base-TX (Half and Full-Duplex)
2000Mb/s
Connector
RJ-45 connector
Cable Support
Performs all the physical
layer functions for 10BASE-T, 100BASE-T, and 1000BASE-T Ethemet on standard
Category 5 UTP
Environment-friendly Products and
Approach
End-of-life Management and Recycling
Hewlett-Packard offers end-of-life HP product return, trade-in, and recycling
programs in many geographic areas. For trade-in information, please go
to: http://www.hp.com/go/green.
To recycle your product, please go to: http://www.hp.com/go/green
or contact your nearest HP sales office. Products returned to HP will
be recycled, recovered or disposed of in a responsible manner.
The EU WEEE directive (2002/95/EC) requires manufacturers to provide treatment
information for each product type for use by treatment facilities. This
information (product disassembly instructions) is posted on the Hewlett
Packard web site at: http://www.hp.com/go/green.
These instructions may be used by recyclers and other WEEE treatment facilities
as well as HP OEM customers who integrate and re-sell HP equipment.